The VEGA VEGAPULS 61 radar level sensor is designed for continuous, non-contact level measurement of liquids under simple process conditions. With 26 GHz radar technology and a measuring range of up to 35 m, it provides reliable level monitoring for tanks and vessels across a range of industrial applications.

Its maintenance-free measuring principle, flexible mounting options, and encapsulated or plastic horn antenna designs make the VEGAPULS 61 a practical solution for water treatment, wastewater systems, and utility installations. Contact us to check the suitable configuration, process connection, and output options for your application.

🕑 Lead time: 4-6 weeks
Quantity:
Visa PayPal Mastercard American Express

Product Introduction

The VEGA VEGAPULS 61 is a radar sensor for continuous, non-contact measurement of liquid levels in tanks and vessels under simple process conditions. It measures the distance to the liquid surface using microwave signals, helping operators monitor levels without direct contact with the medium. Its versatile mounting options support cost-effective installation in industrial and environmental applications.

Key Features

  • Non-contact radar measurement reduces wear and routine maintenance.
  • Measuring range up to 35 m for suitable tank and vessel applications.
  • Measurement accuracy: ±2 mm, according to the published product data.
  • 26 GHz radar technology for continuous liquid-level monitoring.
  • Flexible installation options, including threaded and flange connections, depending on configuration.
  • Multiple output options, including 4–20 mA/HART and fieldbus variants, depending on model.

Applications

  • Water and wastewater treatment plants
  • Water purification and environmental engineering facilities
  • Liquid storage tanks and process vessels
  • Utility systems and power-generation facilities
  • General industrial liquid-level monitoring under simple process conditions

Technical Highlights and Selection Considerations

The VEGAPULS 61 has a published process temperature range of -40 to +80 °C and a process pressure range of -1 to +3 bar. Available antenna designs, wetted materials, process connections, housing options, and communication outputs depend on the selected configuration.

Product status: VEGA identifies the VEGAPULS 6X as the successor to the VEGAPULS 61. For a new installation, consider whether the newer model is more suitable; for replacement or existing systems, verify compatibility and configuration before ordering.

Frequently Asked Questions

1. What does the VEGA VEGAPULS 61 measure?
It measures the level of liquids continuously and without direct contact with the medium.

2. What is the maximum measuring range?
The published maximum measuring range is up to 35 m, depending on the application and configuration.

3. Which industries use the VEGAPULS 61?
Typical applications include water treatment, wastewater management, environmental engineering, power generation, and general industrial liquid storage.

4. What output options are available?
Published versions include two-wire 4–20 mA/HART, as well as selected fieldbus and other output variants. Confirm the required output when specifying the instrument.

5. Is the VEGAPULS 61 still the latest model?
No. VEGA lists the VEGAPULS 6X as its successor. The appropriate choice depends on whether you need a replacement for an existing installation or a sensor for a new project.

Radar Measurement Dynamics & Operating Limits

Measuring Range (Distance) Up to 35 m (114.8 ft)
Measurement Accuracy ± 2 mm
Radar Frequency & Beam Angle 26 GHz K-band technology; beam angle ≥ 10°
Process Pressure Range -1 ... +3 bar (-100 ... +300 kPa / -14.5 ... +43.5 psi)
Process Temperature Range -40 ... +80 °C (-40 ... +176 °F)
Ambient Temperature Range -40 ... +80 °C (-40 ... +176 °F)

Antenna Types, Connections & Materials of Construction

Antenna Configurations Plastic horn antenna ø 80 mm; fully encapsulated horn antenna
Wetted Parts Materials PVDF, 316L Stainless Steel, PP
Threaded & Flange Connections Threaded: G1½, 1½ NPT; Flanged: ≥ DN80, ≥ 3 in.
Hygienic Process Fittings Clamp ≥ 2 in. (DN50 - DIN 32676, ISO 2852); Slotted nut ≥ 2 in. (DN50 - DIN 11851)
Housing Materials Plastic, Aluminium, Stainless steel (precision casting), Stainless steel (electropolished)

Electronics, Communication & Ingress Protection

Output Signals & Protocols Two-wire: 4 ... 20 mA/HART; Four-wire: 4 ... 20 mA/HART; PROFIBUS PA; FOUNDATION Fieldbus; Modbus
Protection Rating (IP Code) IP66/IP67, IP66/IP68 (0.2 bar / 1 bar)
Display & Operation Modules PLICSCOM display/adjustment module, PLICSLED status module, VEGADIS 81 / 82 external display, PC/PACTware DTM, HART-Communicator, AMS™, PDM

Certifications, Approvals & Safety

Explosion Protection (Ex) Intrinsic safety "i", Flameproof enclosure "d" (ATEX, IECEx, FM, CSA, NEPSI, KOSHA, EAC, UKEX)
Functional Safety SIL2 qualified according to IEC 61508
Marine & Overfill Approvals Marine classification (ABS, BV, CCS, DNV, LR, NK, RINA, RMROS), WHG overfill protection