Fluke 572-2 High Temperature Infrared Thermometer

$650.00

The Fluke 572-2 High Temperature Infrared Thermometer provides non-contact temperature measurement from -30 °C to 900 °C, with a 60:1 distance-to-spot ratio and dual laser targeting for accurate measurement of high-temperature equipment and hard-to-reach surfaces.

It also combines infrared and K-type thermocouple measurement, adjustable emissivity, temperature alarms and 99-point data storage in a rugged handheld instrument for demanding industrial inspection and maintenance applications.

🕑 Lead time: In stock
Quantity:
Visa PayPal Mastercard American Express

Fluke 572-2 High Temperature Infrared Thermometer

The Fluke 572-2 High Temperature Infrared Thermometer is a professional handheld temperature measurement instrument designed for high-temperature industrial environments. It provides non-contact infrared measurement up to 900 °C, allowing technicians to inspect hot surfaces without direct contact.

Its combination of long-distance targeting, adjustable emissivity, data storage and K-type thermocouple capability makes it suitable for routine inspection as well as troubleshooting in demanding industrial applications.

High-Temperature Non-Contact Measurement

The Fluke 572-2 measures infrared temperatures from -30 °C to 900 °C (-22 °F to 1652 °F). At temperatures of 0 °C and above, infrared accuracy is specified as ±1 °C or ±1% of the reading, whichever is greater, under the specified calibration conditions.

The 60:1 distance-to-spot ratio allows users to measure smaller targets from greater distances, which is particularly useful when equipment is hot, moving or difficult to access.

Dual Laser Targeting for Accurate Measurement

The 572-2 uses an offset dual laser sighting system to help identify the measurement area. The minimum spot size is 19 mm, while the 8 μm to 14 μm spectral response supports infrared temperature measurement across its specified range.

This makes the instrument suitable for inspecting individual components, pipes, process equipment, electrical connections and other localized heat sources.

Infrared and K-Type Thermocouple Measurement

In addition to infrared measurement, the Fluke 572-2 accepts K-type thermocouple input, allowing users to compare contact and non-contact temperature measurements.

The K-type thermocouple input supports a measurement range of -270 °C to 1372 °C, while the included bead probe is specified for -40 °C to 260 °C.

Key Specifications


  • Infrared temperature range: -30 °C to 900 °C

  • IR accuracy: ±1 °C or ±1% of reading, whichever is greater, above 0 °C

  • Distance-to-spot ratio: 60:1

  • Minimum spot size: 19 mm

  • Laser sighting: Offset dual laser

  • Emissivity: Adjustable from 0.10 to 1.00

  • Spectral response: 8 μm to 14 μm

  • Response time: Less than 500 ms

  • Display resolution: 0.1 °C / 0.1 °F

  • K-type input range: -270 °C to 1372 °C

  • Data storage: Up to 99 measurement points

  • Communication: USB 2.0

  • Power: 2 AA batteries

  • Weight: Approximately 0.322 kg

Adjustable Emissivity and Temperature Analysis

The Fluke 572-2 provides digitally adjustable emissivity from 0.10 to 1.00 in 0.01 increments, as well as a built-in emissivity table for common materials. This helps users compensate for differences in surface emissivity when measuring different materials.

The display can show:


  • Current temperature

  • Maximum temperature

  • Minimum temperature

  • Average temperature

  • Differential temperature

Users can also set high and low temperature alarms for faster identification of abnormal conditions.

Data Storage and Field Documentation

The Fluke 572-2 can store up to 99 measurement data sets for later review and analysis. It also includes a USB 2.0 computer interface and supports connection with Fluke documentation software.

A backlit display with two brightness levels helps maintain visibility in different working environments, while the last-reading Hold function retains the previous measurement for approximately 20 seconds.

Industrial Applications

The Fluke 572-2 is suitable for high-temperature inspection and maintenance applications including:


  • Power generation and utility equipment

  • Metal refining and smelting

  • Glass manufacturing

  • Cement production

  • Petrochemical facilities

  • Industrial process equipment

  • High-temperature machinery

  • Pipes and process lines

  • Electrical and mechanical inspection

  • Preventive maintenance

  • Troubleshooting and condition monitoring

Fluke specifically identifies power utility, metal refining and smelting, glass, cement and petrochemical environments as suitable applications for the 572-2.

Included Accessories

The standard Fluke 572-2 package includes:


  • K-type thermocouple bead probe

  • USB 2.0 computer interface cable

  • Durable hard carrying case

  • FlukeView® Forms Documenting Software

  • Getting started guide

  • User's manual

FAQ

What is the maximum temperature the Fluke 572-2 can measure?

The Fluke 572-2 can measure infrared temperatures up to 900 °C (1652 °F).

What is the distance-to-spot ratio of the Fluke 572-2?

The Fluke 572-2 has a 60:1 distance-to-spot ratio, allowing accurate measurement of smaller targets from relatively long distances.

Does the Fluke 572-2 support thermocouple measurement?

Yes. It accepts K-type thermocouple input and can display infrared and thermocouple temperatures. The K-type input range is -270 °C to 1372 °C.

Can the emissivity be adjusted?

Yes. Emissivity can be digitally adjusted from 0.10 to 1.00 in 0.01 increments, or selected using the built-in emissivity table.

How many measurements can the Fluke 572-2 store?

The instrument can store up to 99 measurement data sets for review and analysis.

Does the Fluke 572-2 include a calibration certificate?

The standard product does not include a current calibration certificate. Fluke states that a calibration certificate can be ordered separately when required.

Infrared Measurements

Infrared temperature range-30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
≥ -10°C to < 0°C: ±2°C
< -10°C: ±3°C
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥ 14°F to < 32°F: ±4°F
< 14°F: ±6°F
IR repeatability±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution0.1°C / 0.1°F
Distance: Spot60:1 (calculated at 90% energy)
Minimum spot size19 mm
Laser sightingOffset dual laser, output < 1 mW
Spectral response8 μm to 14 μm
Response time (95%)< 500 ms
EmissivityDigitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials

Contact Measurements

K-type thermocouple input temperature range-270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)< -40°C: ±(1°C + 0.2° / 1°C)
≥ -40°C: ±1% or 1°C, whichever is greater
< -40°F: ±(2°F + 0.2° / 1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple0.1°C / 0.1°F
K-type thermocouple repeatability±0.5% of reading or ±0.5°C (±1°F), whichever is greater

Measurement Options

Hi/Low alarmsAudible and two-color visual
Min/Max/Avg/DifYes
Switchable celsius and fahrenheitYes
BacklightTwo levels, normal and extra bright for darker environments
Probe inputK-type thermocouple simultaneous display of probe and IR temperature
Trigger lockYes
Data storage99 points
DisplayDot matrix 98 x 96 pixels with function menus
CommunicationUSB 2.0

K-Type Thermocouple Specifications

Measurement range (bead probe)-40°C to 260°C (-40°F to 500°F)
Accuracy±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination

General Specifications

Safety and complianceIEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-20°C to 60°C (-4°F to 140°F)
Relative humidity10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude2000 meters above mean sea level
Weight0.322 kg (0.7099 lb)
Power2 AA batteries
Battery life8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)