Endress+Hauser Memosens Wave CAS80E Digital Water and Wastewater Spectrometer

$360.00

Endress+Hauser Memosens Wave CAS80E Digital Water and Wastewater Spectrometer is an advanced UV-VIS spectrometer for multi-parameter water analysis.

Using absorbance measurement technology from 200 to 800 nm, the CAS80E provides direct in-process measurement of important water quality parameters such as COD, BOD, TOC, SAC254, turbidity, suspended solids and nitrate without complex sample preparation systems.

With real-time monitoring, Memosens digital communication, compact design and low-maintenance operation, it is ideal for drinking water treatment, wastewater treatment plants, industrial wastewater and utility water applications where fast and reliable process information is required.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

Digital UV-VIS Spectrometer for Comprehensive Water Analysis

The Endress+Hauser Memosens Wave CAS80E is a digital optical spectrometer designed for continuous monitoring of water and wastewater quality.

Traditional laboratory analysis often requires sampling, transportation and delayed results. The CAS80E performs measurements directly in the process, providing real-time information about water conditions and helping operators optimize treatment processes.

The compact spectrometer combines multiple measurement functions into one device, reducing the need for multiple individual sensors and simplifying measuring point design.

Typical applications include:


  • Drinking water monitoring

  • Municipal wastewater treatment

  • Industrial wastewater treatment

  • Surface water monitoring

  • Utility water management

UV-VIS Absorbance Measurement Principle

The CAS80E uses UV/VIS absorbance measurement technology from 200 to 800 nm.

The sensor analyzes how the liquid absorbs different wavelengths of light and uses application-specific models to calculate various water quality parameters.

This measurement principle enables:


  • Fast response to water quality changes

  • Continuous online monitoring

  • Multi-parameter analysis with one sensor

  • Reduced dependence on laboratory testing

The measured parameters depend on the selected application and calibration model.

Multiple Water Quality Parameters in One Sensor

One of the main advantages of CAS80E is its ability to measure several important water quality parameters using a single compact device.

Available measurement parameters include:


  • COD equivalent (CODeq)

  • BOD equivalent (BODeq)

  • TOC equivalent (TOCeq)

  • DOC equivalent (DOCeq)

  • SAC254

  • Turbidity

  • Total suspended solids (TSS)

  • Nitrate (NO₃-N)

  • APHA/Hazen color

This multi-parameter capability helps reduce installation complexity and provides a complete overview of water quality conditions.

Direct In-Situ Measurement Without Sample Conditioning

The CAS80E can be installed directly into the process medium, eliminating the need for complicated sampling systems.

Advantages include:


  • No external sample preparation required

  • Faster response compared with laboratory analysis

  • Reduced maintenance requirements

  • Continuous measurement availability

It can also be installed in extractive measurement systems using a flow cell when required by the application.

Memosens Digital Technology

The CAS80E integrates Memosens digital sensor technology, providing secure and reliable communication with Endress+Hauser transmitters.

Benefits include:


  • Digital signal transmission

  • Reliable interference-free communication

  • Sensor data storage

  • Easy calibration management

  • Improved maintenance planning

The sensor can be combined with Liquiline transmitters such as the CM44 series for complete liquid analysis systems.

Easy Installation and Low Maintenance

The compact design of CAS80E simplifies installation and operation.

Key advantages include:


  • Compact sensor construction

  • Easy installation in existing measuring points

  • Reduced maintenance workload

  • Compatibility with automatic cleaning accessories

For demanding applications with increased fouling, the sensor can be combined with cleaning solutions such as CYR51 mechanical cleaning systems.

Reliable Monitoring for Wastewater Treatment

Wastewater treatment requires continuous information about organic load and nutrient concentration.

The CAS80E supports process optimization by monitoring:


  • Incoming wastewater quality

  • Biological treatment performance

  • Final effluent quality

  • Process changes and load variations

Real-time measurement helps operators improve treatment efficiency and maintain stable discharge quality.

Key Features


  • Digital UV-VIS spectrometer for water and wastewater analysis

  • Measures multiple parameters with one sensor

  • UV/VIS absorbance measurement from 200 to 800 nm

  • Direct in-process measurement capability

  • Memosens digital communication technology

  • Suitable for drinking water, wastewater and industrial water applications

  • Measures COD, BOD, TOC, DOC, SAC254, turbidity, TSS and nitrate

  • Compact design with low maintenance requirements

  • Compatible with Liquiline transmitters

  • Optional cleaning accessories available

Typical Applications

Municipal Wastewater Treatment Plants

The CAS80E supports continuous monitoring throughout wastewater treatment processes.

Applications:


  • Wastewater inlet monitoring

  • Aeration process control

  • Biological treatment optimization

  • Final discharge monitoring

  • Organic load measurement

Drinking Water Treatment

The spectrometer helps maintain stable drinking water quality.

Applications:


  • Raw water monitoring

  • Filtration process control

  • Turbidity monitoring

  • Organic contamination detection

Industrial Wastewater Treatment

Industrial processes often require continuous monitoring of wastewater characteristics.

Applications:


  • Process wastewater analysis

  • COD monitoring

  • Discharge quality control

  • Treatment efficiency optimization

Surface Water Monitoring

The CAS80E can be used for environmental water monitoring.

Applications:


  • River water quality monitoring

  • Pollution event detection

  • Long-term water quality analysis

FAQ

What is Endress+Hauser CAS80E?

The CAS80E is a digital UV-VIS spectrometer designed for continuous water and wastewater analysis. It measures multiple analytical parameters including COD, BOD, TOC, turbidity and nitrate.

Is CAS80E a sensor or analyzer?

CAS80E is a digital spectrometer sensor, not a traditional cabinet analyzer. It performs optical measurement directly in the process or through a flow cell installation.

What parameters can CAS80E measure?

Depending on configuration and application model, CAS80E can measure:


  • COD equivalent

  • BOD equivalent

  • TOC equivalent

  • DOC equivalent

  • SAC254

  • Turbidity

  • Suspended solids

  • Nitrate

  • APHA/Hazen color

What is the measurement principle of CAS80E?

CAS80E uses UV-VIS absorbance measurement technology. The sensor analyzes light absorption characteristics of the medium to calculate water quality parameters.

Does CAS80E require reagents?

No. The CAS80E is an optical measurement system and does not require chemical reagents for normal measurement operation.

Where is CAS80E mainly used?

It is mainly used in drinking water plants, wastewater treatment plants, surface water monitoring and industrial water applications.

Measuring principle Absorption
Application Monitoring of WWTP in- and outlet
Drinking water and surface water
Installation Insitu (immersion in process), extractive with sample and flow cell
Characteristic Insitu (immersion in process), extractive with sample and flow cell
UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color
Measuring range Depending on the path length and the application the measuring range vary:
TOCeq: 0 to 8000 mg/l
CODeq: 0 to 20 000 mg/l
BODeq: 0 to 5000 mg/l
SAC254: 0 to 1000 /m
TU: 0 to 4000 FAU
TSS: 0 to 10 000 mg/l
NO3-N: 0 to 1000 mg/l
APHA/Hazen: 0 to 12500 Hazen
Measuring principle UV/VIS absorbance at 200 to 800 nm
Design 40 mm
Material Housing: stainless steel or titanium
Windows: sapphire or quartz
O-rings: EPDM
Dimension 571.4 x 40 mm
21.5 x 1.6 in
Process temperature 0 to 50°C
32 to 122 °F
Process pressure 0.5 to 10 bar abs.
7.3 to 145 psi
Temperature sensor -20 to 60°C
-4 to 140 °F
Connection G1 and NPT 3/4"
Ingress protection IP68