Endress+Hauser Memosens CCS58E Ozone Sensor

$750.00

The Endress+Hauser Memosens CCS58E Ozone Sensor is designed for reliable monitoring of dissolved ozone in water treatment and disinfection processes.

Using an amperometric measuring principle and Memosens 2.0 technology, it provides stable ozone measurement with easier maintenance and reliable digital data management for continuous process control.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

Reliable Ozone Monitoring for Advanced Disinfection Processes

The Memosens CCS58E provides continuous dissolved ozone measurement for applications where effective disinfection and water quality control are essential.

Ozone is widely used as a powerful disinfectant due to its strong oxidation capability. Accurate monitoring helps operators maintain the right ozone concentration while avoiding unnecessary chemical consumption.

Digital Memosens Technology for Easier Maintenance

The CCS58E uses Memosens 2.0 technology, storing sensor information and calibration data digitally inside the sensor.

This enables easier sensor replacement, simplified commissioning and improved measurement data traceability throughout the sensor lifecycle.

Stable Amperometric Ozone Measurement

The sensor uses a membrane-covered amperometric measuring cell to measure dissolved ozone concentration.

This proven measurement principle provides reliable monitoring performance for continuous ozone control applications.

Designed for Water Treatment and Hygienic Applications

The CCS58E is suitable for applications where ozone is used for oxidation and disinfection, including:


  • Drinking water treatment

  • Food and beverage production

  • Bottled water processing

  • Industrial process water

  • Ozone-based disinfection systems

It helps users maintain consistent ozone levels and improve process reliability.

Flexible Integration with Liquiline Systems

Combined with compatible Liquiline transmitters, the CCS58E can be integrated into complete liquid analysis systems.

Users can combine ozone monitoring with other parameters such as pH, conductivity and other disinfection measurements to create a more complete water quality monitoring solution.

Key Features


  • Digital ozone sensor for continuous O₃ monitoring

  • Measures dissolved ozone

  • Memosens 2.0 digital technology

  • Amperometric measurement principle

  • Measuring range:


    0–2 mg/l O₃



  • Process temperature:


    0–45°C



  • Maximum process pressure:


    1 bar



  • Membrane-covered measuring cell

  • Integrated temperature sensor

  • Fast response time

  • Compatible with Liquiline transmitters

  • Suitable for drinking water and industrial disinfection applications

Typical Applications

Drinking Water Treatment

Monitoring ozone concentration during water disinfection processes to maintain effective treatment performance.

Food and Beverage Production

Supporting hygienic production processes where ozone is used for water treatment or cleaning applications.

Bottled Water Processing

Helping maintain consistent ozone levels in purified water treatment systems.

Industrial Water Treatment

Monitoring ozone-based oxidation and disinfection processes in industrial facilities.

Frequently Asked Questions

What is the Endress+Hauser Memosens CCS58E used for?

The CCS58E is a digital sensor designed to measure dissolved ozone (O₃) in water and process applications.

Is CCS58E a chlorine sensor?

No. The CCS58E measures ozone, while CCS50E, CCS51E and CCS53E are designed for chlorine-related measurements.

What measurement principle does CCS58E use?

The sensor uses an amperometric measurement principle with a membrane-covered measuring cell.

What is the measuring range of CCS58E?

The CCS58E measures dissolved ozone in the range of:


  • 0–2 mg/l O₃

What industries use CCS58E?

Typical applications include drinking water treatment, food and beverage processing, bottled water production and industrial ozone disinfection systems.

Does CCS58E require a transmitter?

Yes. The CCS58E is designed to work with compatible Endress+Hauser Liquiline transmitters using Memosens communication.

Measuring Principle
Measuring principleOzone
CharacteristicAmperometric measurement of dissolved ozone
Measuring methodClosed 2-electrode system
Conversion of ozone into a signal current in nA
Signal current is proportional to the concentration of ozone
The measurement is not pH dependent
Application
ApplicationDrinking water – ensures adequate disinfection
Process water – for hygienic packaging and filling
Wastewater – to ensure safe discharge water
Measuring Range
Measuring range0 to 2 mg/l
Design & Materials
DesignExchangeable, electrolyte-filled membrane cap
Working and counter electrode
Adaptable shaft for flexible installation in assemblies
Sensor shaftPVC
MembraneSilicone
Membrane capPVC
Diameter25 mm (0.98 in)
Length161 mm (6.34 in)
Process Conditions
Process temperature0 to 45 °C (32 to 110 °F), non-freezing
Process pressure1 bar (14.5 psi), 2 bar (29 psi) absolute
Sensor & Connection
Temperature sensor10k NTC integrated (Memosens)
ConnectionInductive, digital connection head with Memosens