Endress+Hauser ISEmax CAS40D Digital Ammonium and Nitrate Sensor

$320.00

Endress+Hauser ISEmax CAS40D Digital Ammonium and Nitrate Sensor is a reliable ion-selective sensor for online ammonium and nitrate measurement in wastewater treatment applications.

Using potentiometric ISE measurement technology and Memosens digital communication, the CAS40D provides direct measurement of nutrient parameters directly in aeration basins without requiring expensive sample preparation systems.

With reagent-free operation, automatic cleaning, optional potassium and chloride compensation, and robust ion-selective membranes, it helps optimize aeration control, reduce operating costs and improve wastewater treatment process stability.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

Direct Nutrient Measurement for Wastewater Treatment

The Endress+Hauser ISEmax CAS40D is a digital ion-selective sensor developed for continuous monitoring of nutrient parameters in municipal wastewater treatment plants.

Traditional laboratory analysis or sample-based measurement methods may require complex sampling systems and delayed results. The CAS40D enables direct measurement in the basin, providing real-time information about ammonium and nitrate concentrations for improved process control.

Typical applications include:


  • Aeration basin monitoring

  • Ammonium removal control

  • Nitrate monitoring

  • Load-dependent aeration regulation

  • Wastewater treatment optimization

Ion-Selective Electrode Measurement Principle

The CAS40D uses a potentiometric ion-selective electrode (ISE) measurement principle.

The sensor uses selective membranes to measure specific ions in the wastewater, including:


  • Ammonium (NH₄-N)

  • Nitrate (NO₃-N)

  • Optional potassium

  • Optional chloride

Additional potassium and chloride measurement can compensate for cross-sensitivity effects and improve measurement reliability.

This technology allows continuous nutrient monitoring without chemical reagents.

Optimized Aeration Control and Energy Saving

Aeration is one of the largest energy consumers in wastewater treatment plants. Maintaining the right oxygen supply is essential for efficient nitrogen removal.

The CAS40D provides real-time ammonium and nitrate information, allowing operators to optimize aeration according to actual process conditions.

Benefits include:


  • Improved nitrogen removal efficiency

  • Reduced unnecessary aeration

  • Lower energy consumption

  • More stable wastewater treatment performance

Measurement Without Sample Conditioning

A major advantage of the CAS40D is that it can measure directly in the process.

Compared with traditional analyzer systems, it does not require:


  • External sampling equipment

  • Sample transport pumps

  • Complex conditioning systems

Direct installation in the basin simplifies system design and reduces maintenance requirements.

Memosens Digital Technology

The CAS40D integrates Memosens digital sensor technology, providing secure data transmission and simplified sensor management.

Key advantages include:


  • Digital signal transmission

  • Sensor-specific data storage

  • Easy calibration management

  • Improved measurement reliability

  • Predictive maintenance support

The stored sensor data helps simplify replacement and maintenance procedures.

Automatic Cleaning for Long-Term Stability

Wastewater applications often contain suspended solids and biological deposits that can affect sensor performance.

The CAS40D features a robust design with excellent self-cleaning capability and can be equipped with an automatic flushing unit to reduce maintenance requirements.

Advantages include:


  • Reduced sensor fouling

  • Longer maintenance intervals

  • Stable measurement performance

  • Improved availability

Robust Design for Wastewater Environments

The CAS40D is designed specifically for demanding wastewater applications.

The sensor incorporates:


  • Ion-selective electrodes

  • pH reference electrode

  • Temperature sensor

  • Optional compensation electrodes

Its robust construction allows continuous operation in aeration basins and other wastewater treatment environments.

Key Features


  • Digital ion-selective Memosens sensor

  • Designed for ammonium and nitrate measurement

  • Potentiometric / ISE measurement principle

  • Direct measurement in wastewater basins

  • No sample conditioning required

  • Reagent-free operation

  • Ammonium measuring range: 0.1 to 1000 mg/l NH₄-N

  • Nitrate measuring range: 0.1 to 1000 mg/l NO₃-N

  • Optional potassium and chloride compensation

  • Automatic cleaning option

  • Memosens digital communication

  • Suitable for municipal wastewater treatment plants

  • Compatible with Endress+Hauser Liquiline transmitters

Typical Applications

Municipal Wastewater Treatment Plants

The CAS40D is mainly designed for nutrient monitoring in wastewater treatment processes.

Applications:


  • Aeration basin control

  • Nitrogen removal optimization

  • Ammonium decomposition control

  • Nitrate monitoring

Aeration Process Optimization

The sensor supports load-dependent aeration control by providing continuous ammonium and nitrate measurement.

Applications:


  • Energy-saving aeration strategies

  • Biological treatment optimization

  • Process stability improvement

Industrial Wastewater Treatment

The CAS40D can also support industrial wastewater processes requiring nutrient monitoring.

Applications:


  • Nitrogen removal processes

  • Water quality monitoring

  • Treatment process optimization

Environmental Water Management

The sensor can be used where continuous nutrient monitoring is required for water quality management.

Applications:


  • Wastewater discharge monitoring

  • Nutrient load assessment

  • Process performance evaluation

FAQ

What is Endress+Hauser CAS40D?

The CAS40D is a digital ion-selective Memosens sensor designed for continuous measurement of ammonium and nitrate in wastewater treatment applications.

What does CAS40D measure?

CAS40D measures ammonium and nitrate concentrations. Optional measurement of potassium and chloride can be used for compensation of cross-interference.

What measurement principle does CAS40D use?

The sensor uses a potentiometric ion-selective electrode (ISE) measurement principle.

Does CAS40D require reagents?

No. The CAS40D works without reagents, reducing operating costs and maintenance requirements.

Where is CAS40D mainly used?

It is mainly used in municipal wastewater treatment plants, especially aeration basins where ammonium and nitrate monitoring is required.

What is the difference between CAS40D and CA80AM?

CAS40D is an in-situ ion-selective sensor for direct trend measurement in wastewater basins, while CA80AM is a liquid analysis analyzer using sample handling and reagent-based measurement technology. The suitable choice depends on application requirements.

Measuring principle Potentiometric / ISE
Characteristic Online measurement of nutrient parameters in municipal wastewater treatment plants
Ion-selective electrode system for the continuous measurement of ammonium and nitrate
Size Diameter: 112 mm (4.41 inch)
Immersion depth: 510mm (20.08 inch)
Design Ion-selective electrode(s) for ammonium and/or nitrate, potassium or chloride
pH - (Reference) electrode
Ion-selective electrode for compensating cross-interference
Temperature sensor
Process temperature 2 °C to 40°C (36 to 100 °F)
Ambient temperature -20 °C to 50 °C (-4 to 120 °F)
Process pressure 400 mbar (160 in H2O) max. permitted overpressure
Application Wastewater treatment plants
Measuring range Ammonium:
0.1 to 1000 mg/l (NH4-N)
Nitrate:
0.1 to 1000 mg/l (NO3-N)
Potassium:
1 to 1000 mg/l
Chloride:
1 to 1000 mg/l