Endress+Hauser Flowfit COA30 Oxygen Sensor Calibration Assembly

$370.00

Endress+Hauser Flowfit COA30 Oxygen Sensor Calibration Assembly is a practical calibration tool for oxygen sensors designed to simplify sensor verification and adjustment.

Using defined test gases such as nitrogen, the COA30 enables precise zero-point calibration without the need for traditional calibration methods using sodium sulfite or zero-point gel.

With a compact flow cell design, flexible sensor installation and compatibility with Liquiline transmitters, it helps users perform faster and cleaner oxygen sensor calibration while reducing maintenance time.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

Fast and Reliable Oxygen Sensor Calibration

The Endress+Hauser Flowfit COA30 is a flow cell designed specifically for the calibration of oxygen sensors.

Accurate oxygen measurement depends on regular sensor calibration. The COA30 provides a controlled environment where oxygen sensors can be calibrated using defined test gases, ensuring reliable measurement performance and stable process monitoring.

Compared with conventional calibration methods, the COA30 simplifies the procedure and reduces the time required for maintenance activities.

Calibration Using Defined Test Gases

The COA30 enables oxygen sensor calibration with test gases such as nitrogen for accurate zero-point adjustment.

Key advantages include:


  • Precise oxygen sensor calibration

  • Residue-free calibration process

  • No additional cleaning after calibration

  • Reduced maintenance effort

  • Improved measurement reliability

This makes it suitable for applications where oxygen measurement accuracy is critical.

Flexible Installation for Different Oxygen Sensors

The COA30 is designed for standard 12 mm oxygen sensors with Pg13.5 process connections.

It supports oxygen sensors with different lengths:


  • 120 mm

  • 225 mm

  • 360 mm

  • 420 mm

This flexibility allows the same calibration assembly to be used with various oxygen sensor versions.

Calibration Without Removing Installed Sensors

The PMMA version of Flowfit COA30 allows calibration directly at the measuring point.

Benefits include:


  • Reduced sensor handling

  • Faster maintenance procedures

  • No need to remove installed sensors

  • Convenient calibration during operation

This improves efficiency in plants where frequent sensor removal is difficult.

Compatible with Liquiline Measurement Systems

The COA30 can be combined with Endress+Hauser Liquiline transmitters or handheld devices such as Liquiline Mobile CML18 for convenient calibration.

Integration advantages:


  • Easy sensor connection

  • Simple calibration workflow

  • Reliable measurement data management

  • Flexible field operation

Compact Design for Field Applications

The compact construction makes the COA30 suitable for flexible use in different industries.

Typical benefits include:


  • Portable calibration solution

  • Easy installation

  • Quick setup

  • Reduced downtime during maintenance

The assembly is suitable wherever accurate oxygen sensor calibration is required.

Key Features


  • Oxygen sensor calibration assembly

  • Designed for defined test gas calibration

  • Suitable for 12 mm oxygen sensors with Pg13.5 connection

  • Supports sensor lengths from 120 mm to 420 mm

  • Enables fast zero-point calibration

  • Compatible with Liquiline transmitters

  • Suitable for portable and fixed measuring points

  • Compact flow cell design

  • Reduces calibration time and maintenance effort

Typical Applications

Water and Wastewater Treatment

The COA30 supports oxygen sensor calibration in water treatment applications.

Typical uses:


  • Dissolved oxygen measurement maintenance

  • Aeration process monitoring

  • Sensor performance verification

Food & Beverage Industry

Oxygen measurement is important in many hygienic processes.

Applications include:


  • Filling processes

  • Storage monitoring

  • Production process control

Life Science and Fermentation

The COA30 helps maintain accurate oxygen measurement in fermentation processes.

Applications include:


  • Bioprocess monitoring

  • Fermentation control

  • Oxygen sensor calibration

Power and Energy

Suitable for oxygen monitoring in water and steam cycle applications.

Typical uses:


  • Boiler water monitoring

  • Process water analysis

  • Oxygen measurement maintenance

FAQ

What is Endress+Hauser Flowfit COA30?

The Flowfit COA30 is a flow cell designed for calibration of oxygen sensors using defined test gases.

What does COA30 calibrate?

COA30 is used for calibration of dissolved oxygen sensors.

How does COA30 improve oxygen sensor calibration?

It provides a controlled calibration environment, allowing accurate zero-point calibration with test gases and reducing maintenance time.

Can COA30 be used without removing the sensor?

Yes. The PMMA version allows calibration directly at the measuring point without removing the installed sensor.

Which sensors are compatible with COA30?

It is designed for 12 mm oxygen sensors with standard Pg13.5 connection and supports sensor lengths from 120 mm to 420 mm.

Measuring principle Amperometric oxygen measurement
Application Calibration of oxygen sensors with defined test gases
Installation for 12 mm sensors with standard process connection Pg13.5
for lengths from 120 mm to 420 mm
Material POM (flow cell)
Stainless steel (hose connections)
TPE (edge protection)
TSE/BSE compliant
Dimension Diameter of flow cell: 56 mm
Height of flow cell (without stand base): 195 mm
Height of stand base: 54 mm
Diameter of stand base: 98 mm
Process temperature 0 to 50 °C (32 to 122 °F)
Process pressure 1 to 10 bar (abs) (14.5 to 145 psi)
Connection 4 mm OD hose connection