Endress+Hauser Deltapilot FMB51 Hydrostatic Level Transmitter

$1,100.00

Lorem ipsum is simply dummy text of the printing and typesetting industry lorem ipsum has been the industry's standard dummy text ever since the 1500s

Quantity:

🚚 Item will be delivered on or before

Visa PayPal Mastercard American Express

The Deltapilot FMB51 is a rod version with a fixed process connection. This device with the Contite measuring cell and is typically used in the environmental industry. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

Hydrostatic Level measurement Deltapilot FMB51

Pressure sensor with the Contite measuring cell for hydrostatic level measurement

Specs at a glance

  • Accuracy

    Standard 0.2%
    Optional 0.1%

  • Process temperature

    -10°C...85°C
    (14°F…212°F)

  • Pressure measuring range

    100 mbar...10 bar
    (1.5 psi...150 psi)

  • Process pressure / max. overpressure limit

    40 bar (600 psi)

  • Main wetted parts

    Alloy C
    316L
    optional coating AuPt

  • Max. measurement distance

    100m (328ft) H2O

  • Material process membrane

    316L, AlloyC
    Gold-Rhodium

  • Measuring cell

    100 mbar...10 bar
    (1.5 psi...150 psi)

Field of application

The Deltapilot FMB51 is a rod version with a fixed process connection. This device with the Contite measuring cell and is typically used in the environmental industry. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

 

For level measurement.

  • Process connections: Threads and flanges

  • Temperature: -10 to +85°C (14°F…185° F)

  • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)

  • Accuracy: ±0.2%, ±0.1% (option)

  • International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval

Benefits

  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

  • Modular concept for easy replacement of display or electronics

  • Seamless and independent system integration (HART/PA/FF)

  • Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus

  • International usage thanks to a wide range of approvals