Endress+Hauser CSF48 Stationary Automatic Water Sampler

$1,020.00

Endress+Hauser CSF48 Stationary Automatic Water Sampler is a reliable automatic water sampler designed for wastewater treatment plants, laboratories and industrial process monitoring.

Featuring flexible vacuum and peristaltic pump systems, active cooling and multiple communication options, the CSF48 ensures accurate and representative sampling of liquid media.

With its modular design and expandable functions, it provides a practical solution for water quality monitoring and environmental analysis applications.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

Flexible Automatic Sampling Solution for Water and Industrial Processes

The Endress+Hauser CSF48 is a stationary automatic water sampler designed for collecting representative liquid samples in municipal wastewater treatment plants, industrial facilities and water management applications.

It supports different sampling methods and configurations, allowing users to adapt the system according to specific process requirements.

The CSF48 combines reliable sampling technology with intelligent control functions, data logging and digital communication capabilities for modern water monitoring systems.

Reliable Sampling for Wastewater and Process Monitoring

Accurate sampling is essential for reliable water analysis. The CSF48 helps ensure representative sample collection from different liquid media.

Typical applications include:


  • Municipal wastewater treatment plants

  • Industrial wastewater monitoring

  • Water management facilities

  • Industrial process monitoring

  • Laboratory sample preparation

The sampler supports continuous monitoring strategies by providing consistent sample collection for further analysis.

Flexible Pump and Dosing Systems

The CSF48 offers different dosing system options to meet various installation requirements.

Available configurations include:


  • Vacuum pump system

  • Peristaltic pump system

Depending on the application, users can select the appropriate sampling method according to suction height, sample characteristics and process conditions.

Integrated Cooling System for Sample Preservation

To maintain sample quality, the CSF48 can be equipped with an active dynamic cooling unit.

Benefits include:


  • Improved sample preservation

  • Reduced sample degradation

  • Reliable storage conditions

  • Suitable for long-term monitoring applications

The system also supports heating functions with an evaporator and defrosting unit integrated into the housing.

Modular Design and Communication Options

The CSF48 provides flexible integration into modern automation systems.

Communication options include:


  • CDI interface

  • Ethernet

  • PROFIBUS DP

  • Modbus RS485

  • Modbus TCP

Optional connection to digital sensors with Memosens protocol allows integration with Endress+Hauser digital measurement systems.

Intelligent Data Management

The integrated data logger records important sampling information.

Functions include:


  • Event recording

  • Sampling data storage

  • Sampling statistics

This helps users analyze sampling performance and maintain reliable documentation.

Key Features


  • Stationary automatic water sampler

  • Suitable for municipal and industrial wastewater applications

  • Vacuum pump and peristaltic pump options

  • Active dynamic cooling system

  • Flexible cabinet material options

  • Expandable digital sensor connection

  • Memosens protocol support

  • Multiple fieldbus communication options

  • Integrated data logger

  • Reliable sample collection and preservation

Typical Applications

Municipal Wastewater Treatment

The CSF48 is designed for wastewater plants requiring reliable automatic sampling.

Applications include:


  • Inlet and outlet water monitoring

  • Compliance sampling

  • Water quality analysis

Industrial Wastewater Monitoring

Suitable for industrial facilities requiring regular sample collection.

Common industries:


  • Chemical plants

  • Manufacturing facilities

  • Process industries

Environmental Monitoring

The sampler supports water management organizations and laboratories with consistent sample collection.

Applications include:


  • Surface water monitoring

  • Pollution control

  • Laboratory analysis

Industrial Process Monitoring

The CSF48 can collect process liquid samples for quality control and process optimization.

FAQ

What is Endress+Hauser CSF48?

The CSF48 is a stationary automatic water sampler designed for collecting representative liquid samples in wastewater, industrial and environmental applications.

What liquids can CSF48 sample?

CSF48 can be used for various liquid media, including wastewater and industrial process liquids.

What is the difference between vacuum pump and peristaltic pump systems?

Vacuum pump systems are suitable for general sampling applications, while peristaltic pump systems provide flexible sampling performance for different media conditions.

Does CSF48 support digital sensors?

Yes. CSF48 supports optional connection to digital sensors using Memosens protocol.

Where is CSF48 commonly used?

It is commonly used in wastewater treatment plants, laboratories, water management offices and industrial process monitoring systems.

Measuring Principle
Measuring principleSampler
FunctionsStationary sampler
Application
ApplicationCommunal and industrial wastewater treatment plants
Laboratories and water management offices
Monitoring of liquid media in industrial processes
Sampling System
Dosing systemVacuum pump system
Peristaltic pump system
Armature
Suction height6 m (19.69 ft)
8 m (26.25 ft)
DistributionPossible
Housing & Climate Control
CabinetPlastic PS
Plastic ASA+PC
Stainless steel V2A
Stainless steel V4A
CoolingActive, dynamic cooling unit
HeatingEvaporator and defrosting unit mounted in compact housing
Dimension1258 x 753 x 625 mm (h x w x d)
49.5 x 29.7 x 24.6 inch (h x w x d)
Weight91 to 146 kg
Process Conditions
Process temperatureSample temperature: 2 to 50 °C (36 to 122 °F)
Process pressureMax. 0.8 bar (max. 11.6 psi)
Inputs, Outputs & Communication
InputAnalogue: 2, galvanically isolated
Binary: 2, galvanically isolated
Optional: 1 to 4 digital sensors
Output / communicationBinary: 2, galvanically isolated
Optional 2 to 6 relay, 2 to 6 current output
InterfaceCDI
Optional: Ethernet, PROFIBUS DP, Modbus RS485, Modbus TCP
Data loggerAll events and data
Sampling statistics
Power supplyDepending on version:
100 to 120 / 200 to 240 V AC ±10 %, 50/60 Hz
24 V DC +15/-9 %
Accessories & Options
AccessoriesSampling from pressurized systems
Dosing system
Housing equipment
Electrical equipment
OptionsConnection to digital sensors with Memosens protocol, fieldbus communication