Endress+Hauser CAS51D Digital Nitrate SAC Sensor

$560.00

The Endress+Hauser CAS51D is a digital optical nitrate and SAC sensor designed for continuous water quality monitoring in drinking water, wastewater and utility applications.

Using a UV photometric measurement principle, the sensor provides online measurement of nitrate, SAC (spectral absorption coefficient) and related parameters without the need for chemical reagents. Its robust design and Memosens digital technology help simplify operation while maintaining reliable process monitoring.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

Optical Measurement for Water Quality Monitoring

The CAS51D provides continuous measurement of important water quality parameters including:


  • Nitrate

  • SAC

  • COD equivalent

  • TOC equivalent

  • BOD equivalent

  • DOC equivalent

This makes it suitable for applications where operators need real-time information about organic load or nutrient levels in water treatment processes.

Chemical-Free and Low-Maintenance Operation

Unlike traditional laboratory analysis methods, the CAS51D performs measurement directly in the process using optical technology.

The sensor requires no chemical reagents and is designed for continuous operation with reduced maintenance requirements, helping improve process efficiency and reduce operating costs.

Designed for Drinking Water and Wastewater Applications

The CAS51D is widely used in water treatment applications including:


  • Drinking water monitoring

  • Wastewater treatment plants

  • Biological treatment processes

  • Nitrate monitoring in aeration basins

  • Denitrification process control

  • Effluent monitoring

It helps operators optimize treatment processes through continuous measurement instead of relying only on periodic laboratory sampling.

Memosens Digital Technology

With Memosens digital technology, the CAS51D stores sensor information and calibration data directly in the sensor.

This simplifies commissioning, maintenance and sensor replacement while improving measurement data reliability.

Flexible Installation Options

The CAS51D can be installed directly in the process or used with flow assemblies for extractive measurement.

Available installation methods include:


  • Immersion installation

  • Flow cell installation

  • Sample-based measurement systems

This allows flexible integration into different water treatment systems.

Key Features


  • Digital optical nitrate and SAC sensor

  • Measures nitrate, SAC and related sum parameters

  • UV photometric measurement principle

  • Chemical-free measurement technology

  • Memosens digital communication

  • Measuring range:


    Nitrate: 0.01 to 20 mg/l NO₃-N / 0.1 to 50 mg/l NO₃-N


    SAC: 0 to 50 / 250 / 1000 1/m


    CODₑq: 0 to 75 / 375 / 1500 mg/l


    TOC/DOCₑq: 0 to 30 / 150 / 600 mg/l



  • Process temperature: 5 to 50°C

  • Sensor diameter: 40 mm

  • Sensor material: 316L stainless steel

  • Protection rating: IP68

  • Supports immersion and flow-cell installation

  • Suitable for drinking water, wastewater and utilities

Typical Applications

Drinking Water Treatment

Used for monitoring nitrate levels and water quality changes in drinking water production.

Wastewater Treatment

Suitable for monitoring:


  • Inlet and outlet organic load

  • Nitrate removal processes

  • Biological wastewater treatment

  • Denitrification stages

Industrial Water Management

Used in industrial utilities where continuous monitoring of water quality parameters is required.

Process Optimization

Helps operators optimize treatment processes through continuous measurement of nitrate and organic load indicators.

FAQ

What is the Endress+Hauser CAS51D?

The CAS51D is a digital optical sensor for measuring nitrate, SAC and related water quality parameters in drinking water, wastewater and utility applications.

What parameters can CAS51D measure?

Depending on the selected version, CAS51D can measure:


  • Nitrate

  • SAC

  • COD equivalent

  • TOC equivalent

  • BOD equivalent

  • DOC equivalent

Does CAS51D require chemical reagents?

No. The CAS51D uses optical UV measurement technology and does not require chemical reagents during operation.

What is the measuring principle?

The CAS51D uses UV photometric measurement to determine nitrate and SAC values.

What industries use CAS51D?

Typical applications include:


  • Drinking water plants

  • Wastewater treatment plants

  • Industrial utilities

  • Surface water monitoring

Does CAS51D support Memosens?

Yes. The CAS51D uses Memosens digital technology for secure data management and easier maintenance.

Measuring Principle
Measuring principleUV photometric
CharacteristicIn situ (immersion in process), extractive with sample and flow cell
Optical photometric sensor for nitrate and SAC
Application
ApplicationDrinking water, biological waste water process, WWTP effluent
Monitoring of surface water
Measuring Range
Nitrate (NO3-N)0.01 to 20 mg/l / 0.1 to 50 mg/l
Nitrate (NO3)0.04 to 80 mg/l / 0.4 to 200 mg/l
SAC0 to 50 1/m / 0 to 250 1/m / 0 to 1000 1/m
COD/BOD (254 nm)0 to 75 mg/l / 0 to 375 mg/l / 0 to 1500 mg/l
TOC/DOC (254 nm)0 to 30 mg/l / 0 to 150 mg/l / 0 to 600 mg/l
Design & Size
Design40 mm sensor, stainless steel 316L
Size388 / 394 mm x 40 mm, depends on version
Process Conditions
Process temperature5 to 50 °C (41 to 120 °F)
Ambient temperature-20 to 60 °C (-4 to 140 °F)
Specials
Process connectionG1, NPT 3/4"
Ingress protectionIP68 (1 m / 3.3 ft water column with 1N KCl during 60 days)