WIKA Model TI.1005 pocket test thermometer

$120.00

The WIKA TI.1005 is a compact pocket test thermometer designed for quick, direct temperature measurement. Its 1-inch dial, 5-inch pointed stainless steel stem, and protective pocket case make it convenient for routine inspections and field testing.

With an accuracy of ±1% of full scale and selectable Fahrenheit ranges, the TI.1005 is suitable for food processing, automotive testing, and HVAC/R maintenance. Its mechanical design requires no external power supply.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

The WIKA TI.1005 uses a bimetal measuring element to convert temperature changes into mechanical pointer movement. It provides a direct reading on its dial without batteries or external electrical connections.

Its pointed 5-inch stem is designed for insertion into suitable materials or measurement points, while the included pocket case protects the stem during storage and transport. The external hex-hub adjustment allows the indication to be reset as specified by the manufacturer.

Key Features

  • Measuring principle: Mechanical bimetal thermometer.
  • Dial size: 1 inch (25.4 mm).
  • Accuracy: ±1% of full scale, ASME B40.3 Grade A.
  • Stem length: 5 inches.
  • Stem diameter: 0.142 inch.
  • Stem tip: Pointed for convenient insertion into suitable measurement points.
  • Case material: Stainless steel.
  • Connection: Plain connection with 7/16-inch hex hub.
  • Adjustment: External adjustment through the hex hub.
  • Dial: White-coated aluminum with black markings.
  • Pointer: Aluminum with a matte red finish.
  • Window: Lexan.
  • Included accessory: Pocket case for carrying and stem protection.
  • Power supply: Not required.

Suitable Applications

  • Food processing: Routine temperature checks where the stem and instrument are appropriate for the application.
  • HVAC and refrigeration: Field temperature inspections during maintenance and troubleshooting.
  • Automotive testing: Temperature checks on suitable components and test setups.
  • Equipment testing: Portable temperature indication during inspection and commissioning.
  • Maintenance work: Quick spot checks where a compact mechanical thermometer is preferred.

WIKA identifies food processing, testing, automotive, and HVAC/R as application areas for the TI.1005. For food-related use, verify the required hygiene and material requirements before selecting the instrument.

Technical Highlights & Selection Considerations

Before ordering the WIKA TI.1005, confirm these details:

  • Measuring range: Choose the correct scale for the expected temperature.
  • Stem length and diameter: The standard stem is 5 inches long and 0.142 inch in diameter.
  • Dial readability: The 1-inch dial is compact and best suited to close-range reading.
  • Insertion conditions: Confirm that the pointed stem and measuring method are appropriate for the material being measured.
  • Scale units: The listed standard ranges are in Fahrenheit.
  • Adjustment requirements: Confirm whether external reference adjustment is required.
  • Hygiene requirements: For food applications, check whether the instrument meets the site's cleaning, sanitation, and regulatory requirements.

Available measuring ranges and model codes:

  • −40 to 160 °F — 1005219D
  • 0 to 220 °F — 1005223D
  • 50 to 550 °F — 1005216D

FAQ

Q1: What is the WIKA TI.1005 used for?

It is a portable thermometer for spot temperature checks in food processing, testing, automotive, and HVAC/R applications.

Q2: Does the TI.1005 need batteries?

No. Its bimetal mechanism provides a mechanical dial reading without external power.

Q3: What is the stem length?

The standard TI.1005 has a 5-inch stem with a diameter of 0.142 inch and a pointed tip.

Q4: What temperature ranges are available?

The listed Fahrenheit ranges are −40 to 160 °F, 0 to 220 °F, and 50 to 550 °F. Choose the model code that matches the required operating range.

Q5: Does the TI.1005 come with a protective case?

Yes. WIKA specifies a pocket case that can hold and protect the stem when the thermometer is not in use.

Measurement Performance & Design Features

Nominal Dial Size 1 in (25.4 mm) - Type TI.1005
Measurement Accuracy ±1.0% of full scale value
Standard Temperature Ranges -40 to 160 °F (-40 to 71 °C)
0 to 220 °F (-18 to 104 °C)
50 to 550 °F (10 to 288 °C)
Typical Applications Food processing & catering, laboratory spot testing, HVAC/R air and coil temperature inspection
Product Accessories Protective plastic pocket case with pocket clip and built-in calibration wrench slot

Materials & Mechanical Construction

Case Material Corrosion-resistant stainless steel
Stem Dimensions & Tip Length: 5 in (127 mm); Diameter: 0.142 in (3.6 mm); Sharpened pointed tip for easy semi-solid/liquid penetration
Connection & Calibration Center back mount (CBM); Plain 7/16 in hex hub with external field recalibration provision
Dial & Pointer White-coated aluminium dial with crisp black markings; Aluminium pointer with high-visibility matte red finish
Window Material Impact-resistant Lexan® (polycarbonate)