Siemens SITRANS TH320 7NG031 Temperature Transmitter

$220.00

Universal input. HART® communication. SIL2/3 ready. Reliable temperature measurement in any environment.

The SITRANS TH320 is a high-performance 2-wire head transmitter designed for demanding industrial applications. It supports RTD, thermocouple, resistance, and DC voltage inputs – configurable via PC or HART®. Compact design fits connection heads type B or larger.

4–20 mA output with HART® · Galvanic isolation · Diagnostic LED · Wire break and short-circuit monitoring · Self-monitoring · SIL2/3 version available · ATEX, FM, CSA hazardous area approvals · EEPROM configuration storage.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

The Siemens SITRANS TH320 (Model 7NG031) is a high-performance, industrial-grade temperature transmitter designed to provide reliable and high-precision process temperature measurement in various demanding industrial environments. It supports connection to multiple temperature sensors (e.g., RTD, thermocouples), features a robust housing, excellent noise immunity, and easy configuration. It is widely used in factory automation, process industries, and energy sectors.

Catalog sheet SITRANS TH320

SIEMENS SITRANS TH320 7NG031 Temperature transmitters

SITRANS TH320 and TH420 combine perfect measurement and intelligence at any temperature and condition. Real reliability is guaranteed, for example, by the dual sensor input of the TH420 incl. 4-wire sensor connection and hot backup function. In case of a sensor failure, the transmitter automatically switches to the second sensor, and the valuescontinue to be recorded seamlessly and without loss.

Overview

  • 2‑wire head transmitter with and without HART communications interface
  • Mounting in the connection head of the temperature sensor
  • Universal input for virtually any type of temperature sensor
  • Can be configured via PC, HART 7 or optional local operation

Benefits

  • Compact design
  • Flexible mounting and center hole allow you to select your preferred mounting type
  • Galvanic isolation
  • Test terminals for ammeter
  • Diagnostics LED (green/red)
  • Input monitoring wire break and short-circuit
  • Self-monitoring
  • Configuration status stored in EEPROM
  • SIL2/3 (with order note C20)
  • Expanded diagnostic functions, such as slave pointer, operating hours counter, etc.
  • Special characteristic
  • Electromagnetic compatibility according to EN 61326 and NE21

Application

SITRANS TH320 transmitters can be used in all sectors. Its compact size means that it can be installed in connection heads of type B or larger. The following sensors/signal sources can be connected over their universal input module:

  • Resistance thermometer (2-wire, 3-wire, 4-wire connection)
  • Thermocouples
  • Linear resistance, potentiometer and DC voltage sources

With HART communications interface:

  • The output signal is a load-independent direct current from 4 to 20 mA in accordance with the input characteristic, superimposed by the digital HART signal.

Transmitters of the "intrinsically safe or Zone 2 increased safety" type of protection can be installed in hazardous areas. The device meets the requirements of the EU Directive 2014/34/EU (ATEX), the FM and CSA regulations as well as other national approvals.

Function

Without HART communications interface

For the SITRANS TH320 without HART functionality, parameters are assigned with the PC. A special modem and the software tool SIPROM T are available for this purpose.

With HART communications interface:

The SITRANS TH320 is configured via HART. The configuration can be carried out using a handheld communicator or, more conveniently, with a HART modem and the SIMATIC PDM parameterization software. The configuration data is then permanently stored in the non-volatile memory (EEPROM).

After correct connection of input and supply voltage, the transmitter outputs a temperature-linear output signal and the diagnostics LED is green. In case of external errors, e.g. sensor short circuit or interruption, the LED flashes red; an internal device error is indicated by a permanent red light.

An ammeter can be connected at any time for checking and plausibility via the test terminals. The output current can be read without any interruption, or even without opening the current loop.

Parameter Specification
Brand / Model Siemens SITRANS TH320
Article Number 7NG031.0.A.00.A0
Net Weight 0.05 kg
Input Resistance thermometer (RTD) · 1 sensor resistor
Output 4–20 mA · 2-wire · Galvanically isolated · Failure signal 3.5–23 mA
Measuring Accuracy ±0.1% of span
Long-term Drift 0.05% / year · 0.18% / 5 years
Ambient Temperature –50 °C ... +85 °C (operation, storage & transport)
Max. Relative Humidity 99%
Vibration Resistance Max. 40 m/s² (per IEC 60068-2-6)
Protection Rating IP68
EMC Standard IEC 61326-1 · NAMUR NE21
Enclosure Material Polyamide (PA)
Galvanic Isolation Test Voltage 2,500 V DC
Cable Cross-section 1.5 mm²
Display LED
Supply Voltage 7.5–24 V DC (nominal 24 V)
Mounting Connection head type B (DIN 43729)