Siemens SITRANS FS220 7ME3950 Clamp-on Ultrasonic Flowmeter

$1,500.00

Non-invasive flow measurement. Install without process downtime. Reliable for water, chemicals, and energy.

The SITRANS FS220 is a clamp-on ultrasonic flow system combining the FST020 transmitter with FSS200 sensors. It mounts externally onto existing pipes – no cutting, no production stop, no media contact. Ideal for water and wastewater, chemical feed, HVAC, and industrial process monitoring.

Pipe sizes from 10 mm to 10 m · Media temperatures –40 to 121 °C (high-temp option to 230 °C) · Wide turndown · Bidirectional · Anomaly compensation for non-ideal pipe runs · Optional WideBeam technology for challenging conditions.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

The Siemens SITRANS FS220 (Model 7ME3950) is an advanced clamp-on ultrasonic flowmeter. It features non-invasive installation, requiring no pipe cutting, and delivers high-precision, reliable measurement for various liquids. Ideal for process monitoring and custody transfer in water, chemical, and energy industries, it offers easy installation and low maintenance for industrial flow measurement.

Catalog sheet SITRANS FS220

SIEMENS SITRANS FS220 7ME3950 Clamp-on Ultrasonic Flowmeter

SITRANS FS offers versatile flow measurement for liquids and gases. Choose a non-invasive clamp-on solution for cost-effective and fast installation,avoiding process downtime. Alternatively,choose an inline version for direct media contact. Whether your application is standard or complex,you get reliable performance across various industries, including water, chemical, oil & gas and hydrogen

Overview

The SITRANS FS220 is a clamp-on ultrasonic flow system consisting of an FST020 transmitter and FSS200 clamp-on sensors.

The transmitter classification FST020 describes a basic clamp-on ultrasonic flowmeter for basic application requirements. Based on the same digitalized platform as the FST030 this system provides the same accuracy and similar functions on a lower cost level. This system is ideal for water measurement and any application not requiring temperature or viscosity compensation.

Benefits

  • Easy installation at any time; no production stop, no need to cut pipe or stop flow
  • Minimal maintenance; external sensors do not require periodic cleaning
  • No moving parts to foul or wear. No contact with media
  • No pressure drop or energy loss
  • Wide turn-down ratio, bidirectional and high stability at zero flow conditions
  • Anomaly compensation tool for correction of non-ideal straight pipe runs. Automatic compensation during backflow
  • Optional WideBeam technology ensures highest performance and accuracy
  • Compatible with all previously installed transit time sensors

Application

The SITRANS FS220 can be used for the following application conditions:

  • Pipe sizes from 10 mm to 10 m
  • Pipe materials: ideal for all metals, glass, FRP and most PVC variants; NOT for concrete pipes and special compound pipes
  • Pipe wall thickness from 1 to 35 mm; specials on request up to 65 mm
  • Media temperatures from -40 to 121 °C; universal high temperature sensors for up to 230 °C max.
  • Underground/submerged locations, non-ideal environments, strong pipe vibrations

SITRANS FS220 flowmeters are suitable for most clean liquid applications, including the following:

  • Water and wastewater industry

    Potable water
    Water and aqueous solutions
    Wastewater, influent & effluent
    Processed sewage, sludge

  • Chemical feed industry

    Sodium hypochlorite
    Sodium hydroxide

  • HVAC and power industries

    Coolant flow
    Fuel flow
    Utility district heating, cooling
    Refrigeration liquids

  • Process control

    Chemicals
    Pharmaceuticals
    Food products
    Very low flow sensitiity (< 0.1 m/s)
    High temperature liquids > 120 °C (248 °F)

Function

Operating principle

The SITRANS FS system is a transit-time ultrasonic meter that provides exceptional performance using a non-intrusive clamp-on approach. Ultrasonic sensors transmit and receive acoustic signals directly though the existing pipe wall, where the fluid refraction angle is governed by Snell’s law of refraction.

 

```html
Parameter Specification
Brand / Model Siemens SITRANS FS220 (FST020)
Article Number 7ME35701J.400..1-Z S30
Net Weight 1.4 kg
Measuring Principle Ultrasonic, 1-path clamp-on
Measurand Volume flow · Flow velocity · Sound velocity
Flow Direction Bidirectional
Max. Flow Velocity 12 m/s
Accuracy ±0.15%
Sampling Frequency Max. 5 Hz
Analog Output 4–20 mA · Max. load 750 Ω · Output voltage 24–30 V
Pulse Output 1 × passive · Max. 30 V · Min. load 3,000 Ω
Relay Output 1 × SPDT · Max. 30 V DC / 250 mA / 3 VA
Digital Input 2 × (2–10 V DC) · Counter reset / Freeze output
Communication RS-485 · Modbus
Medium Temperature Min. –40 °C
Ambient Temperature (Operation) –10 °C ... +50 °C
Ambient Temperature (Storage) –20 °C ... +60 °C
Protection Rating IP65 · NEMA 4X
EMC Standard 2004/108/EC
Transmitter Material Polycarbonate (PC)
Mounting Wall mounting · Separated version (sensor separated)
Display LCD · 5 pushbuttons
MTBF 41 a (per SN 29500)
```