Fluke 374 FC True-RMS AC/DC Clamp Meter

$287.00

The Fluke 374 FC True-RMS AC/DC Clamp Meter combines advanced electrical measurement capability with wireless Fluke Connect connectivity for efficient troubleshooting.

It measures AC/DC current up to 600 A, voltage up to 1000 V and resistance up to 6000 Ω, while optional iFlex technology expands AC current measurement up to 2500 A for large cables and confined spaces.

🕑 Lead time: In stock
Quantity:
Visa PayPal Mastercard American Express

Fluke 374 FC True-RMS AC/DC Clamp Meter

The Fluke 374 FC is a professional True-RMS wireless clamp meter designed for industrial electricians, maintenance technicians and field service engineers who require reliable electrical measurements with improved safety and efficiency.

The meter combines essential troubleshooting functions with Fluke Connect wireless technology, allowing measurement data to be viewed remotely through compatible mobile devices. This helps technicians reduce exposure to electrical hazards while collecting and documenting test results.

Key Features


  • True-RMS AC/DC clamp meter

  • AC current measurement up to 600 A

  • DC current measurement up to 600 A

  • AC/DC voltage measurement up to 1000 V

  • Optional iFlex flexible current probe expands AC measurement up to 2500 A

  • Fluke Connect wireless connectivity

  • Remote measurement viewing through smartphone devices

  • Min/Max/Average recording

  • Inrush current measurement

  • Resistance measurement up to 6000 Ω

  • Capacitance measurement up to 1000 μF

  • Continuity detection

  • CAT III 1000 V / CAT IV 600 V safety rating

  • 34 mm jaw opening

  • Three-year warranty

True-RMS AC/DC Measurement

The Fluke 374 FC provides accurate True-RMS measurement for both AC and DC signals.

It can measure:


  • AC current: up to 600 A

  • DC current: up to 600 A

  • AC voltage: up to 1000 V

  • DC voltage: up to 1000 V

True-RMS technology allows more reliable measurements on non-linear electrical loads commonly found in modern industrial equipment.

iFlex Flexible Current Probe Compatibility

When combined with an optional iFlex flexible current probe, the Fluke 374 FC can measure AC current up to 2500 A.

The flexible probe design makes it easier to measure:


  • Large power cables

  • Busbars

  • Crowded electrical panels

  • Difficult-to-access conductors

The thin flexible design allows technicians to perform measurements in areas where standard clamp jaws may not fit.

Fluke Connect Wireless Function

The Fluke 374 FC is part of the Fluke Connect wireless test tool family.

With wireless connectivity, technicians can:


  • View measurements remotely

  • Record measurement data

  • Save results to the Fluke Connect cloud system

  • Create reports directly from the field

  • Reduce the need to stand close to energized equipment

This function improves safety and productivity during electrical troubleshooting tasks.

Inrush Current Measurement

The Fluke 374 FC includes inrush current measurement for capturing the starting current of motors, transformers and other electrical equipment.

This helps technicians diagnose:


  • Motor starting problems

  • Circuit breaker issues

  • Power supply faults

  • Electrical load abnormalities

Additional Measurement Functions

Besides current measurement, the Fluke 374 FC provides:

Voltage Measurement


  • AC voltage: up to 1000 V

  • DC voltage: up to 1000 V

Resistance Measurement


  • Range: up to 6000 Ω

  • Includes continuity detection

Capacitance Measurement


  • Range: up to 1000 μF

These functions allow the meter to be used as a complete troubleshooting instrument rather than a current-only clamp meter.

Applications

The Fluke 374 FC is suitable for:


  • Industrial electrical maintenance

  • Motor troubleshooting

  • Control panel inspection

  • Power distribution testing

  • HVAC electrical diagnostics

  • Electrical equipment commissioning

  • Preventive maintenance

  • Automation system troubleshooting

  • Commercial electrical service

  • Field service applications

Safety Design

The Fluke 374 FC is designed for demanding electrical environments with:


  • CAT III 1000 V

  • CAT IV 600 V

Safety ratings according to IEC standards allow technicians to perform measurements in high-energy electrical installations when used correctly.

General Specifications


  • AC current via jaw: 600 A

  • DC current: 600 A

  • AC current via iFlex: 2500 A

  • AC/DC voltage: 1000 V

  • Resistance: 6000 Ω

  • Capacitance: 1000 μF

  • Jaw opening: 34 mm

  • Display: Digital display

  • Battery: 2 × AA alkaline batteries

  • Operating temperature: -10 °C to +50 °C

  • Dimensions: 249 × 85 × 45 mm

  • Weight: 395 g

  • Safety rating: CAT III 1000 V / CAT IV 600 V

FAQ

What is the maximum current measurement of the Fluke 374 FC?

The Fluke 374 FC measures AC and DC current up to 600 A through the clamp jaw. With an optional iFlex flexible current probe, AC current measurement can reach 2500 A.

Does the Fluke 374 FC support wireless communication?

Yes. The Fluke 374 FC supports Fluke Connect wireless connectivity for viewing and recording measurements through compatible mobile devices.

Is the Fluke 374 FC a True-RMS meter?

Yes. It provides True-RMS AC voltage and current measurement for accurate readings on complex electrical signals.

Can the Fluke 374 FC measure DC current?

Yes. It measures DC current up to 600 A.

What is the difference between Fluke 374 FC and Fluke 376 FC?

The Fluke 376 FC offers higher direct jaw current capability (up to 999.9 A) and additional advanced functions, while the Fluke 374 FC provides a more economical solution with 600 A measurement capability.

General Specifications AC Current via Jaw Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) Crest Factor (50 Hz/60 Hz) 2.5 @ 600 A Add 2% for C.F. >2 AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Position Sensitivity Flexible current probe Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1.5% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Resistance Range 6000 Ω Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity - non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) ≤45% RH (at 40 °C to 50 °C) Operating altitude 3000 m Storage altitude 12,000 m Size (L x W x H) 249 x 85 x 45 mm Weight 395 g Jaw opening 34 mm Flexible current probe diameter 7.5 mm Flexible current probe cable length (head to electronics connector) 1.8 m Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C