Rosemount 1208 Non-Contact Radar Level & Flow Transmitter

$800.00

The Rosemount 1208 Non-Contacting Level and Flow Transmitter from Emerson uses 80 GHz FMCW radar technology for reliable liquid and selected solids level measurement, as well as open-channel flow calculations. Its compact, corrosion-resistant PVDF housing is designed for demanding outdoor environments, water and wastewater systems, and basic chemical applications.

Featuring Smart Echo Supervision™, optional Bluetooth® connectivity and flexible output options, the Rosemount 1208 simplifies installation and commissioning. Its encapsulated design is fully submersible, while food-grade and drinking-water-approved materials support suitable hygienic and potable water applications.

🕑 Lead time: 4-6 weeks
Quantity:
Visa PayPal Mastercard American Express

The Rosemount 1208 is a compact, non-contacting radar transmitter designed for continuous level measurement and open-channel flow calculations. It measures distance to the product surface without contacting the medium, helping reduce maintenance requirements. With a corrosion-resistant PVDF housing and multiple communication options, it is suitable for water management, utilities and basic industrial applications.

Key Features

  • 80 GHz FMCW radar technology for non-contacting measurement
  • Continuous level measurement and open-channel flow calculations
  • Smart Echo Supervision™ to distinguish product echoes from obstructions
  • Compact, corrosion-resistant PVDF housing
  • Encapsulated design suitable for extended submersion
  • Optional Bluetooth® wireless configuration
  • Available outputs include 4–20 mA HART®, 4–20 mA, IO-Link and switching output, depending on model
  • Food-grade and drinking-water-approved materials
  • M12 electrical connector for simplified installation
  • Mounting accessories for new and existing systems

Suitable Applications

  • Water and wastewater treatment
  • Open-channel flow measurement
  • Water storage tanks and reservoirs
  • Pumping stations and drainage systems
  • Chemical storage tanks
  • Utility systems
  • Sludge and wastewater level monitoring
  • Outdoor and flood-prone installations
  • Selected small-tank solids applications

Technical Highlights & Selection Considerations

  • Measurement application: Confirm whether you need level measurement, open-channel flow calculation or both.
  • Measuring range: The maximum measuring range is up to 15 m, depending on the medium and installation conditions.
  • Accuracy: Reference accuracy is up to ±2 mm under specified conditions.
  • Process connection: Standard options include 1½-inch G and NPT threads; compatible mounting accessories are available.
  • Output type: Select the appropriate 4–20 mA HART®, 4–20 mA, IO-Link or switching-output version.
  • Bluetooth® connectivity: Confirm whether local wireless configuration is required for the selected model.
  • Housing material: PVDF offers corrosion resistance for suitable water and chemical applications.
  • Installation conditions: Consider mounting position, obstructions, turbulence and the required submersion conditions.
  • Approvals: Verify drinking-water, food-grade and hazardous-area requirements for the exact model.

Frequently Asked Questions

Q1: What is the Rosemount 1208 used for?

It provides continuous level measurement and supports open-channel flow calculations in water, wastewater, utility and basic chemical applications.

Q2: How does the Rosemount 1208 measure level?

It uses non-contacting 80 GHz FMCW radar to measure the distance to the product surface without direct contact with the medium.

Q3: Can the Rosemount 1208 measure open-channel flow?

Yes. Its built-in software supports flow calculations for compatible flumes and open channels.

Q4: Is the Rosemount 1208 waterproof or submersible?

Emerson describes its encapsulated design as fully submersible over extended periods. Confirm the specified installation and environmental limits for the selected model.

Q5: Which communication options are available?

Depending on the model, options include 4–20 mA HART®, 4–20 mA, IO-Link, switching output and optional Bluetooth® connectivity.

Q6: What information should I provide when ordering?

Confirm the measurement application, required range, output type, process connection, mounting accessories, installation environment and any required approvals.

Measurement Performance & Operating Ratings

Measurement Range Up to 49.2 ft. (15 m) for level, volume, and open-channel flow measurement
Accuracy ±0.08 in. (±2 mm)
Operating Temperature Range -40 to 176 °F (-40 to 80 °C)
Operating Pressure Limits -14 to 43 psi (-1 to 3 bar)

Communications, Materials & Certifications

Communication Protocols Bluetooth® wireless technology, 2-wire 4-20 mA HART, 3-wire 4-20 mA, IO-Link, and PNP/NPN digital switch output
Process Wetted Material Corrosion-resistant PVDF (encapsulated antenna body)
Enclosure Protection Rating IP67 / IP68 (submersible up to 3 m for 48 h); NEMA 4X / NEMA 6P
Drinking Water & Sanitary Certifications NSF/ANSI 61, WRAS, KTW-BWGL drinking water approvals; FDA and EC 1935/2004 food contact compliance
Hazardous Area Approvals ATEX, IECEx, FM intrinsic safety and dust explosion certifications