Fluke 726 Precision Multifunction Calibrator

$2,985.00

The Fluke 726 Precision Multifunction Calibrator is designed for accurate field calibration of process transmitters, sensors, valves and control devices across electrical, temperature, pressure and frequency applications.

With 0.01% mA accuracy, dual-channel measurement, 24 V loop power, RTD and thermocouple sourcing, pressure module compatibility and automated step/ramp functions, it provides broad process calibration capability in one rugged instrument.

🕑 Lead time: In stock
Quantity:
Visa PayPal Mastercard American Express

Fluke 726 Precision Multifunction Calibrator

The Fluke 726 is a precision multifunction process calibrator designed for process instrumentation professionals who need high accuracy and broad measurement coverage in the field.

It can measure and source multiple process parameters, including mA, DC voltage, resistance, frequency, RTDs and thermocouples, while pressure measurement and sourcing can be added through compatible Fluke 750P pressure modules. 

Precision Calibration for Process Instrumentation

The Fluke 726 combines high measurement accuracy with functions intended for practical field calibration.

Its current measurement and source accuracy is specified at 0.01%, while the instrument provides 0.001 mA resolution for 0–24 mA measurement and sourcing. This makes it suitable for precision testing of process transmitters and analog control signals. 

Key Specifications


  • mA measurement: 0–24 mA

  • mA source/simulation: 0–24 mA

  • mA accuracy: 0.01% + 2 counts

  • mA resolution: 0.001 mA

  • DC voltage measurement: up to 30 V

  • DC voltage source: up to 20 V

  • Resistance: 0–4000 Ω

  • Frequency: up to 15 kHz

  • RTD: Measure and source

  • Thermocouples: Measure and source

  • Pressure: Compatible with Fluke 750P pressure modules

  • Loop power: 24 V DC

  • Auto-step: 25% and 100% range

  • Auto-ramp: Slow ramp, fast ramp and 25% step-ramp

  • Operating temperature: -10 °C to +55 °C

  • Dimensions: 200 × 96 × 47 mm

  • Weight: 650 g

  • Power: 4 AA alkaline batteries

  • Warranty: 3 years 

Dual-Channel Process Calibration

A major advantage of the Fluke 726 is its two-channel architecture. The separate channels allow technicians to measure, source or view process signals simultaneously.

This is particularly useful when comparing an input signal with a transmitter output or when performing more complex calibration procedures without repeatedly changing connections.

4–20 mA Transmitter Calibration

The 726 provides a 24 V loop power supply and simultaneous mA measurement, allowing a transmitter to be powered and tested during calibration.

It can source or simulate current signals for checking:


  • Pressure transmitters

  • Flow transmitters

  • Level transmitters

  • Temperature transmitters

  • PLC/DCS analog inputs

  • Control system loops

The 24 V loop supply is rated for up to 22 mA and is short-circuit protected.

RTD and Thermocouple Calibration

The Fluke 726 can both measure and source RTD and thermocouple signals, allowing technicians to simulate temperature sensor inputs and verify transmitter outputs.

Supported RTD types include:


  • Cu10

  • Ni120

  • Pt100

  • Pt200

  • Pt500

  • Pt1000

Thermocouple support includes common types such as:


  • J

  • K

  • T

  • E

  • R

  • S

  • B

  • L

  • N

  • U

This allows the 726 to be used for both temperature transmitter calibration and sensor simulation.

Pressure Transmitter Calibration

Pressure capability can be added by connecting one of the Fluke 750P Series Pressure Modules.

The 750P family covers differential, gauge, vacuum, absolute, dual and high-pressure applications, with pressure accuracy available from 0.025% of range, depending on the module selected.

The 726 can therefore be used for:


  • Pressure transmitter calibration

  • Pressure switch testing

  • Gauge verification

  • I/P converter testing

  • Control valve testing

Valve and I/P Testing

The 726 can source mA while simultaneously measuring pressure, making it useful for testing current-to-pressure converters and control valves.

This allows technicians to observe the relationship between an electrical control signal and the resulting pressure response without requiring multiple separate instruments.

Pressure Switch Testing

The integrated pressure switch test function can capture:


  • Set point

  • Reset point

  • Deadband

When combined with an appropriate pressure module, the 726 can therefore be used to verify pressure switches during commissioning and maintenance.

Enhanced Flowmeter Testing

The Fluke 726 also includes enhanced functions for flowmeter testing, including a frequency totalizer and frequency pulse-train source mode.

This makes it suitable for testing flow instruments that use frequency or pulse outputs in addition to conventional 4–20 mA signals.

Automatic Step and Ramp Testing

For transmitter linearity testing, the 726 provides automatic output functions including:


  • Slow ramp

  • Fast ramp

  • 25% step-ramp

  • 25% steps

  • 100% steps

These functions allow technicians to test transmitter response across multiple calibration points more efficiently.

Calibration Result Storage

The Fluke 726 can store up to eight calibration results in memory for later analysis.

It can also calculate transmitter error percentage directly, reducing the need for manual calculations during field calibration.

Fluke 726 vs. Fluke 725

The Fluke 725 and Fluke 726 share a broad multifunction process calibration platform, but the 726 is positioned as the precision model.

The 726 provides 0.01% mA accuracy, dual-channel operation, calibration result storage, pressure switch testing and enhanced flowmeter testing. It is therefore better suited to applications where measurement accuracy and broader process calibration capability are more important.

简单理解:

Fluke 725 → Multifunction Process Calibrator

Fluke 726 → Precision Multifunction Process Calibrator

如果客户需要更高精度以及更复杂的过程校准功能,726 是更合适的选择。

Fluke 726 vs. Fluke 754

The Fluke 726 is a precision multifunction calibrator, while the Fluke 754 adds documenting capabilities and integrated HART communication.

If the application mainly requires high-accuracy multifunction process calibration, the 726 is well suited. If the workflow also requires digital HART configuration and documented calibration procedures, the 754 is the more appropriate platform. Fluke itself recommends the 754 when documenting and HART communication are required.

Typical Applications

Pressure Instrumentation


  • Pressure transmitter calibration

  • Pressure switch testing

  • I/P converter testing

  • Control valve testing

Temperature Instrumentation


  • RTD transmitter calibration

  • Thermocouple transmitter calibration

  • Temperature sensor simulation

  • Temperature loop testing

Flow Instrumentation


  • Flow transmitter testing

  • Frequency output verification

  • Pulse train testing

  • Flowmeter calibration

Process Control


  • 4–20 mA loop testing

  • PLC/DCS analog I/O verification

  • Transmitter commissioning

  • Signal simulation

  • Linearity testing

Maintenance


  • Field calibration

  • Preventive maintenance

  • Troubleshooting

  • Zero/span verification

  • Multi-point calibration

FAQ

Q: What is the Fluke 726 used for?

A: The Fluke 726 is used for precision calibration of process transmitters, sensors, valves and other process instruments across mA, voltage, temperature, frequency, resistance and pressure applications.

Q: Can the Fluke 726 calibrate 4–20 mA transmitters?

A: Yes. It can measure, source and simulate up to 24 mA and provides a built-in 24 V loop supply for transmitter testing.

Q: Can the Fluke 726 calibrate RTDs and thermocouples?

A: Yes. It can both measure and source multiple RTD and thermocouple types.

Q: Can the Fluke 726 measure pressure?

A: Yes. Pressure measurement and sourcing are available when the 726 is used with compatible Fluke 750P pressure modules.

Q: Does the Fluke 726 support HART communication?

A: No. The 726 is a precision multifunction calibrator. For integrated HART communication and documenting functions, Fluke positions the 754 Documenting Process Calibrator with HART as the appropriate model.

Measurement Accuracy
Voltage DC 30.000 V: 0.01% + 2 mV (upper display)
20.000 V: 0.01% + 2 mV (lower display)
90.00 mV: 0.01% + 10 μV
-10.00 mV to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC 24.000 mA: 0.01%+ 2 mA
Resistance 0.0 to 4000.0 Ω: ± 0.015%
Frequency 2.0 to 1000.0 CPM: 0.05% + 0.1 cpm
1.0 to 1000.0 Hz: 0.05% + 0.1 Hz
1.00 to 15.00 kHz: 0.05% + 0.01 kHz
Sensitivity 1 V peak-to-peak-minimum
Pressure Accuracy from 0.025% of range using any of (50) 750P pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC 100.00 mV: 0.01% + 10 μV
20.000 V: 0.01% + 2 mV
-10.00 mV to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC 24.000 mA (Source): 0.01% + 2 μA
24.000 mA (Simulate): 0.01% + 2 μA
Resistance
(Range, accuracy and excitation current)
5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA
5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA
400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA
1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA
Frequency 2.0 to 1000.0 CPM: 0.05%
1.0 to 1000.0 Hz: 0.05%
1.0 to 10.0 kHz: 0.25%
10.0 to 15.0 kHz: 0.5%
Waveform 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure and source accuracy Cu10: 1.8°C
NI-120: 0.15°C
PT-100 (385): 0.45°C
PT-100 (392): 0.35°C
PT-100 (391-JIS): 0.35°C
PT-200 (385): 0.95°C
PT-500 (385): 0.55°C
PT-1000 (385): 0.35°C
J: 0.4°C
K: 0.5°C
T: 0.4°C
E: 0.4°C
R: 1.4°C
S: 1.4°C
B: 1.4°C
L: 0.45°C
U: 0.45°C
N: 0.6°C
XK: 0.4°C
BP: 1.1°C
RTD Resolution 0.01°C (0.01°F)
Cu10.01 C: 0.1°C (0.1°F)
TC Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
Specifications
Ramp functions Source functions: Voltage, current, resistance, frequency, temperature
Ramps: Slow ramp, Fast ramp, 25% step-ramp
Loop power function Voltage: 24 V
Accuracy: 10%
Maximum current: 22 mA, short circuit protected
Step functions Source functions: Voltage, current, resistance, frequency, temperature
Steps: 25% of range, 100% of range
Environmental Specifications
Operating temperature -10°C to +55°C
Storage temperature -20°C to +71°C
Operating altitude 3000 m
Safety Specifications
Agency approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Mechanical and General Specifications
Size 200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in)
Weight 650 g (23 oz)
Batteries 4 AA alkaline batteries
Battery replacement Separate battery compartment, accessible without breaking calibration seal
Side port connections Pressure module connector, also used for remote real-time programming