Fluke 725 Multifunction Process Calibrator
The Fluke 725 is a versatile multifunction process calibrator designed for technicians and engineers who need to test a wide range of process instrumentation in the field. Instead of carrying separate instruments for current, voltage, temperature and frequency testing, the 725 combines these functions into one rugged handheld calibrator.
It can measure and source mA, DC voltage, temperature, frequency and resistance, while optional Fluke 750P pressure modules extend its capabilities to pressure measurement.
One Calibrator for Multiple Process Parameters
The Fluke 725 covers many of the signals commonly encountered in industrial process instrumentation:
DC current: 0–24 mA
DC voltage: up to 30 V measurement
RTDs: multiple Pt and Ni RTD types
Thermocouples: J, K, T, E, R, S, B, L, N, U and other supported types
Resistance: up to 3200 Ω
Frequency: up to 10 kHz depending on function
Pressure: using compatible Fluke 750P pressure modules
24 V DC loop power
mA source and simulate functions
Auto-step and auto-ramp
Store and recall frequently used calibration setups
This makes the 725 particularly useful when a project involves several different types of process transmitters rather than only 4–20 mA loops.
4–20 mA Loop Calibration
The Fluke 725 provides 0–24 mA measurement, sourcing and simulation, with 0.001 mA resolution and 0.02% + 2 counts accuracy according to the current specification.
Its built-in 24 V loop power supply can power a transmitter while simultaneously measuring the resulting mA signal. This allows technicians to test a transmitter outside the normal control loop and isolate wiring, transmitter or signal problems.
Typical applications include:
4–20 mA transmitter calibration
Process loop troubleshooting
Analog I/O testing
PLC signal verification
Transmitter commissioning
Control valve signal testing
Temperature Transmitter Calibration
The 725 can both measure and source RTD and thermocouple signals, allowing technicians to simulate sensor inputs and verify the output of temperature transmitters.
Supported sensor types include common RTDs such as:
Pt100
Pt200
Pt500
Pt1000
Ni120
It also supports a broad selection of thermocouples including J, K, T, E, R, S, B, L, N and U.
This makes the 725 suitable for checking temperature transmitters without requiring a separate temperature calibrator.
Pressure Transmitter and I/P Testing
When used with compatible Fluke 750P pressure modules, the Fluke 725 can measure pressure across differential, gauge, vacuum, absolute, dual and high-pressure applications. Fluke specifies pressure accuracy from 0.025% of range, depending on the pressure module used.
The 725 can also source mA while simultaneously measuring pressure, allowing technicians to perform valve and I/P (current-to-pressure) tests with a single instrument.
This is particularly useful for:
Pressure transmitter calibration
I/P converter testing
Control valve troubleshooting
Pressure switch verification
Valve positioner testing
Flowmeter and Frequency Testing
The Fluke 725 includes frequency and CPM (counts per minute) functions for testing pulse-based devices and flowmeters.
It can also perform auto-step and auto-ramp tests, allowing technicians to change the output signal automatically and observe transmitter or control-system response across multiple points.
This is useful for:
Flowmeter pulse output testing
Frequency transmitter testing
Pulse signal verification
Linearity checks
PLC input testing
Designed for Field Calibration
The Fluke 725 is built around a straightforward field-service workflow. Its controls are designed without complex menus, while the backlit display improves visibility in low-light conditions.
The compact, rugged design makes it suitable for commissioning, maintenance and troubleshooting in demanding industrial environments.
Key Specifications
Current measurement: 0–24 mA
Current source/simulation: 0–24 mA
mA accuracy: 0.02% + 2 counts
mA resolution: 0.001 mA
Voltage measurement: 0–30 V DC
Voltage source: up to 10 V / 20 V depending on function
Resistance: up to 3200 Ω
Frequency: up to 10 kHz
RTD and thermocouple: Measure and source
Loop supply: 24 V DC
Pressure: Compatible with Fluke 750P pressure modules
Calibration functions: Auto-step and auto-ramp
Display: Backlit
Calibration setup: Store and recall
Included documentation: NIST-traceable calibration report and data
Fluke 725 vs. Fluke 707
The Fluke 707 is primarily a dedicated current loop calibrator for 4–20 mA measurement, sourcing and simulation.
The Fluke 725 is considerably broader. It adds RTD, thermocouple, resistance, frequency and pressure capabilities, making it more suitable when one calibrator needs to cover several process measurement technologies.
In simple terms:
Fluke 707 → specialized mA loop calibration
Fluke 725 → multifunction process calibration
For general process instrumentation maintenance, the 725 offers substantially broader measurement coverage.
Typical Applications
The Fluke 725 can be used for:
Pressure Instrumentation
Pressure transmitter calibration
Pressure switch testing
I/P converter testing
Control valve testing
Temperature Instrumentation
RTD transmitter calibration
Thermocouple transmitter calibration
Temperature sensor simulation
Flow Instrumentation
Flowmeter frequency testing
Pulse output verification
4–20 mA flow transmitter testing
Process Control
PLC analog I/O testing
Control loop troubleshooting
Signal simulation
Transmitter commissioning
Maintenance
Field calibration
Linearity testing
Auto-ramp testing
Preventive maintenance
FAQ
Q: What is the Fluke 725 used for?
A: The Fluke 725 is used for measuring and sourcing multiple process signals, including mA, voltage, RTDs, thermocouples, resistance and frequency, with optional pressure measurement.
Q: Can the Fluke 725 calibrate 4–20 mA transmitters?
A: Yes. It can measure, source and simulate 0–24 mA signals and provides a built-in 24 V loop supply.
Q: Can the Fluke 725 calibrate temperature transmitters?
A: Yes. It can source and measure a wide range of RTD and thermocouple signals for temperature transmitter testing.
Q: Can the Fluke 725 measure pressure?
A: Yes. Pressure measurement is available when the 725 is used with compatible Fluke 750P pressure modules.
Q: Can the Fluke 725 test control valves?
A: Yes. It can source mA while simultaneously measuring pressure, allowing it to be used for valve and I/P testing.
Q: Is the Fluke 725 a HART communicator?
A: No. The 725 is a multifunction process calibrator rather than a dedicated HART communicator. For HART device configuration and communication, the Fluke 154 is the more appropriate instrument.