Endress+Hauser CPA875 Retractable Assembly

$650.00

Endress+Hauser CPA875 Retractable Assembly is a sterile retractable process assembly designed for safe installation of pH, ORP and oxygen sensors in hygienic applications.

Featuring a fully hygienic design with certified process connections, the CPA875 supports reliable measurement in pharmaceutical, biotechnology and food industries where contamination control is critical.

Its safe retractable mechanism allows sensor inspection, cleaning and replacement without compromising process integrity.

🕑 Lead time: 6-8 weeks
Quantity:
Visa PayPal Mastercard American Express

Sterile Retractable Assembly for Hygienic Processes

The Endress+Hauser CPA875 is a retractable process assembly specifically designed for sterile and hygienic applications.

It provides a reliable installation solution for pH, ORP and dissolved oxygen sensors in processes where strict hygiene requirements, repeatability and contamination prevention are essential.

Compared with standard retractable assemblies, the CPA875 is optimized for applications requiring a higher level of process safety, such as pharmaceutical production and biotechnology processes.

Designed for Pharmaceutical and Biotech Applications

The CPA875 is developed for industries where maintaining sterile conditions is a key requirement.

Typical applications include:


  • Pharmaceutical manufacturing

  • Biotechnology production

  • Sterile fermentation processes

  • Life science applications

  • Hygienic food production

The assembly supports reliable sensor measurement while helping maintain process cleanliness.

Safe Sensor Replacement Without Process Interruption

The retractable design allows sensors to be inserted into or removed from the process safely.

Benefits include:


  • Reduced production downtime

  • Easier sensor maintenance

  • Faster calibration procedures

  • Improved operator safety

The sensor can be serviced while maintaining process conditions when used with suitable safety procedures.

Hygienic and Sterile Design

The CPA875 features a design focused on preventing contamination and supporting clean processes.

Key advantages include:


  • Suitable materials for hygienic applications

  • Smooth internal surfaces

  • Cleanable process design

  • Support for sterilization and cleaning procedures

It is suitable for processes requiring compliance with strict hygiene standards.

Compatible with pH, ORP and Oxygen Sensors

The CPA875 can be combined with Endress+Hauser liquid analysis sensors for monitoring:


  • pH value

  • ORP value

  • Dissolved oxygen

This makes it a flexible solution for critical process measurement points.

Key Features


  • Sterile retractable process assembly

  • Designed for pH, ORP and oxygen sensors

  • Hygienic design for pharmaceutical and biotechnology applications

  • Safe sensor insertion and removal

  • Suitable for SIP and CIP processes

  • Supports sterile process measurement

  • Reduces maintenance downtime

  • Compatible with Endress+Hauser sensor systems

  • Designed for demanding hygienic applications

Technical Specifications


  • Application: Hygienic and sterile process measurement

  • Assembly type: Retractable process assembly

  • Sensor compatibility: 12 mm diameter sensors

  • Suitable sensors: pH, ORP and dissolved oxygen sensors

  • Installation location: Tanks, reactors and pipelines

  • Wetted materials: Stainless steel and hygienic process materials depending on configuration

  • Process temperature: Suitable for sterilization applications depending on configuration

  • Process pressure: Suitable for demanding hygienic process conditions

  • Cleaning capability: CIP and SIP compatible versions available

  • Process connections: Hygienic connections available

Typical Applications

Pharmaceutical Industry

The CPA875 is widely used in pharmaceutical production processes requiring sterile measurement.

Typical applications:


  • Bioreactors

  • Fermentation processes

  • Cell culture monitoring

  • Purified process systems

Biotechnology

Suitable for biotech processes where contamination control and reliable sensor performance are essential.

Applications include:


  • Upstream processing

  • Fermentation monitoring

  • Cell cultivation

Food and Beverage Industry

Used in hygienic production processes requiring reliable pH and oxygen measurement.

Typical applications:


  • Fermentation

  • Beverage production

  • Quality monitoring

Life Science Applications

The CPA875 provides a safe sensor installation solution for critical measurement points where process integrity must be maintained.

FAQ

What is Endress+Hauser CPA875?

The CPA875 is a sterile retractable process assembly designed for installing pH, ORP and dissolved oxygen sensors in hygienic applications.

What is the difference between CPA871 and CPA875?

CPA871 is a flexible retractable assembly for general industrial applications.

CPA875 is designed specifically for sterile and hygienic applications, especially pharmaceutical, biotechnology and life science processes.

Which sensors can be installed with CPA875?

CPA875 supports compatible Endress+Hauser pH, ORP and dissolved oxygen sensors.

Can CPA875 be used for SIP and CIP processes?

Yes. CPA875 is designed for hygienic applications and supports cleaning and sterilization processes depending on configuration.

Where is CPA875 commonly used?

It is mainly used in pharmaceutical, biotechnology, food and other hygienic process industries.

Measuring Principle
Measuring principlePotentiometric
Application & Installation
ApplicationFood and beverages, biotechnology, life sciences, special chemicals
InstallationRetractable process assembly
CharacteristicOpen and closed tanks, piping
Design & Materials
DesignSterile and hygienic style
Manual or pneumatic
HolderStainless steel 1.4435
SealsEPDM-FDA, FKM-FDA, FFKM-FDA
Immersion depth16.1 to 81.4 mm (0.63 to 3.20 inch), depending on process adaption
Process Conditions
Process temperature-10 to 140 °C (14 to 284 °F)
Process pressurePneumatic drive: 16 bar up to 140 °C (232 psi up to 284 °F)
Manual drive: 8 bar up to 140 °C (116 psi up to 284 °F)
Connection
Process connectionAseptic DN25 clampable, aseptic DN50 screw-in, clamp ISO 2852, ASME BPE, Varivent N