{"product_id":"yokogawa-ejx120a-differential-pressure-transmitter","title":"Yokogawa EJX120A Differential Pressure Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"768\" data-end=\"804\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"806\" data-end=\"996\"\u003eThe \u003cstrong data-start=\"810\" data-end=\"864\"\u003eYokogawa EJX120A Differential Pressure Transmitter\u003c\/strong\u003e is a high-performance draft range DP transmitter designed for precise measurement of differential pressure in industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"998\" data-end=\"1310\"\u003eBased on Yokogawa’s advanced \u003cstrong data-start=\"1027\" data-end=\"1063\"\u003eDPharp digital sensor technology\u003c\/strong\u003e, it provides high stability, fast response, and long-term accuracy. It is widely used for \u003cstrong data-start=\"1154\" data-end=\"1203\"\u003eliquid level measurement in pressurized tanks\u003c\/strong\u003e, \u003cstrong data-start=\"1205\" data-end=\"1247\"\u003eflow measurement with primary elements\u003c\/strong\u003e, and \u003cstrong data-start=\"1253\" data-end=\"1309\"\u003edensity or interface detection in process industries\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1312\" data-end=\"1556\"\u003eThe EJX120A is known for its excellent long-term stability and diagnostic capabilities, helping reduce maintenance costs and improve process reliability in demanding environments such as oil \u0026amp; gas, chemical plants, and power generation systems.\u003c\/p\u003e\n\u003cp data-start=\"1558\" data-end=\"1742\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1589\" data-end=\"1626\"\u003edifferential pressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1628\" data-end=\"1646\"\u003eDP transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1648\" data-end=\"1681\"\u003eYokogawa pressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1683\" data-end=\"1716\"\u003elevel measurement transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1718\" data-end=\"1742\"\u003eindustrial DP sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1744\" data-end=\"1747\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1749\" data-end=\"1765\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1767\" data-end=\"2149\"\u003e• High-precision DPharp digital sensor technology\u003cbr data-start=\"1816\" data-end=\"1819\"\u003e• Accuracy up to ±0.09% of span\u003cbr data-start=\"1850\" data-end=\"1853\"\u003e• Fast response time (150 ms)\u003cbr data-start=\"1882\" data-end=\"1885\"\u003e• Long-term stability ±0.15% per year\u003cbr data-start=\"1922\" data-end=\"1925\"\u003e• Suitable for liquid, gas, and steam applications\u003cbr data-start=\"1975\" data-end=\"1978\"\u003e• SIL2 \/ SIL3 safety certification\u003cbr data-start=\"2012\" data-end=\"2015\"\u003e• HART \/ Fieldbus communication options\u003cbr data-start=\"2054\" data-end=\"2057\"\u003e• Advanced diagnostics for impulse line detection\u003cbr data-start=\"2106\" data-end=\"2109\"\u003e• Robust industrial-grade construction\u003c\/p\u003e\n\u003chr data-start=\"2151\" data-end=\"2154\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"2156\" data-end=\"2182\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2184\" data-end=\"2460\"\u003e\n\u003cli data-section-id=\"1tclxpy\" data-start=\"2184\" data-end=\"2222\"\u003ePressurized tank level measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1jrzd90\" data-start=\"2223\" data-end=\"2264\"\u003eFlow measurement using orifice plates\u003c\/li\u003e\n\u003cli data-section-id=\"1820j57\" data-start=\"2265\" data-end=\"2296\"\u003eChemical process monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"ejdnol\" data-start=\"2297\" data-end=\"2327\"\u003eOil \u0026amp; gas pipeline systems\u003c\/li\u003e\n\u003cli data-section-id=\"1x31490\" data-start=\"2328\" data-end=\"2356\"\u003eSteam and boiler systems\u003c\/li\u003e\n\u003cli data-section-id=\"1u0vjpw\" data-start=\"2357\" data-end=\"2394\"\u003eDensity and interface measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1xzh7uk\" data-start=\"2395\" data-end=\"2426\"\u003ePower plant process control\u003c\/li\u003e\n\u003cli data-section-id=\"xwcxty\" data-start=\"2427\" data-end=\"2460\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2462\" data-end=\"2465\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2467\" data-end=\"2500\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2502\" data-end=\"2536\"\u003eBefore selecting EJX120A, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2538\" data-end=\"2881\"\u003e\n\u003cli data-section-id=\"1v40a4h\" data-start=\"2538\" data-end=\"2602\"\u003eRequired differential pressure range (draft range selection)\u003c\/li\u003e\n\u003cli data-section-id=\"1qobu8o\" data-start=\"2603\" data-end=\"2646\"\u003eStatic pressure conditions (MWP limits)\u003c\/li\u003e\n\u003cli data-section-id=\"10qmym3\" data-start=\"2647\" data-end=\"2685\"\u003eMedium type (liquid \/ gas \/ steam)\u003c\/li\u003e\n\u003cli data-section-id=\"10u9tom\" data-start=\"2686\" data-end=\"2737\"\u003eInstallation type (flanged \/ manifold mounting)\u003c\/li\u003e\n\u003cli data-section-id=\"1nzjwqo\" data-start=\"2738\" data-end=\"2785\"\u003eOutput protocol (4–20 mA \/ HART \/ Fieldbus)\u003c\/li\u003e\n\u003cli data-section-id=\"1buonto\" data-start=\"2786\" data-end=\"2836\"\u003eSafety certification requirement (SIL2 \/ SIL3)\u003c\/li\u003e\n\u003cli data-section-id=\"1bmmtbe\" data-start=\"2837\" data-end=\"2881\"\u003eNeed for remote configuration or display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2883\" data-end=\"2886\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2888\" data-end=\"2902\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2904\" data-end=\"3081\"\u003e\u003cstrong data-start=\"2904\" data-end=\"2945\"\u003eQ: What is Yokogawa EJX120A used for?\u003c\/strong\u003e\u003cbr data-start=\"2945\" data-end=\"2948\"\u003eA: It is used for differential pressure measurement in level, flow, and density applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3083\" data-end=\"3238\"\u003e\u003cstrong data-start=\"3083\" data-end=\"3123\"\u003eQ: What technology does EJX120A use?\u003c\/strong\u003e\u003cbr data-start=\"3123\" data-end=\"3126\"\u003eA: It uses Yokogawa’s DPharp digital resonant silicon sensor technology. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3240\" data-end=\"3365\"\u003e\u003cstrong data-start=\"3240\" data-end=\"3279\"\u003eQ: What is the accuracy of EJX120A?\u003c\/strong\u003e\u003cbr data-start=\"3279\" data-end=\"3282\"\u003eA: It offers up to ±0.09% accuracy of span. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3367\" data-end=\"3493\"\u003e\u003cstrong data-start=\"3367\" data-end=\"3411\"\u003eQ: Can it be used for level measurement?\u003c\/strong\u003e\u003cbr data-start=\"3411\" data-end=\"3414\"\u003eA: Yes, it is widely used for differential pressure level measurement in tanks.\u003c\/p\u003e\n\u003cp data-start=\"3495\" data-end=\"3610\"\u003e\u003cstrong data-start=\"3495\" data-end=\"3537\"\u003eQ: Does it support HART communication?\u003c\/strong\u003e\u003cbr data-start=\"3537\" data-end=\"3540\"\u003eA: Yes, it supports HART and other industrial communication protocols.\u003c\/p\u003e\n\u003cp data-start=\"3612\" data-end=\"3727\"\u003e\u003cstrong data-start=\"3612\" data-end=\"3658\"\u003eQ: Is it suitable for safety applications?\u003c\/strong\u003e\u003cbr data-start=\"3658\" data-end=\"3661\"\u003eA: Yes, it is certified for SIL2\/SIL3 safety instrumented systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43318877388861,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/ejx120a-differential-pressure-transmitter-product-view.png?v=1783064713","url":"https:\/\/proinstru.com\/products\/yokogawa-ejx120a-differential-pressure-transmitter","provider":"Process Instrument","version":"1.0","type":"link"}