{"product_id":"vega-vegaflex-83-tdr-level-and-interface-sensor","title":"VEGA VEGAFLEX 83 TDR Level and Interface Sensor","description":"\u003cp data-start=\"380\" data-end=\"600\"\u003eThe \u003cstrong data-start=\"384\" data-end=\"410\"\u003eVEGAFLEX 83 TDR Sensor\u003c\/strong\u003e delivers accurate \u003cstrong data-start=\"429\" data-end=\"475\"\u003econtinuous level and interface measurement\u003c\/strong\u003e for liquids. It uses \u003cstrong data-start=\"497\" data-end=\"532\"\u003eTime Domain Reflectometry (TDR)\u003c\/strong\u003e to ensure stable performance, even in demanding process conditions.\u003c\/p\u003e\n\u003cp data-start=\"602\" data-end=\"901\"\u003eThis sensor performs especially well in \u003cstrong data-start=\"642\" data-end=\"670\"\u003emulti-phase applications\u003c\/strong\u003e, such as oil and water separation. In addition, it handles \u003cstrong data-start=\"730\" data-end=\"794\"\u003ehigh temperatures, pressure variations, and aggressive media\u003c\/strong\u003e with ease. Because of its robust design, it is widely used in chemical, oil \u0026amp; gas, and process industries.\u003c\/p\u003e\n\u003cp data-start=\"903\" data-end=\"1020\"\u003eNot Recommended For:\u003cbr data-start=\"923\" data-end=\"926\"\u003e• Applications with heavy foam or strong buildup\u003cbr data-start=\"974\" data-end=\"977\"\u003e• Media with very low dielectric constant\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/instrugauge.com\/wp-content\/uploads\/46597-EN-Level-and-interface-measurement-in-liquids-VEGAFLEX-81-83-86-1.pdf\"\u003eVEGAFLEX 83 TDR sensor for continuous level and interface measurement of liquids\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-content-block\"\u003e\n\u003cdiv class=\"product-content-block\"\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1068\" data-end=\"1086\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1088\" data-end=\"1245\"\u003e• \u003cstrong data-start=\"1090\" data-end=\"1110\"\u003eMeasurement Type\u003c\/strong\u003e: The VEGAFLEX 83 is ideal for \u003cstrong data-start=\"1141\" data-end=\"1187\"\u003econtinuous level and interface measurement\u003c\/strong\u003e. It is especially suitable for \u003cstrong data-start=\"1219\" data-end=\"1242\"\u003emulti-phase liquids\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1247\" data-end=\"1404\"\u003e• \u003cstrong data-start=\"1249\" data-end=\"1271\"\u003eProcess Conditions\u003c\/strong\u003e: It operates reliably under \u003cstrong data-start=\"1300\" data-end=\"1333\"\u003ehigh temperature and pressure\u003c\/strong\u003e. However, always confirm your exact process limits before selection.\u003c\/p\u003e\n\u003cp data-start=\"1406\" data-end=\"1577\"\u003e• \u003cstrong data-start=\"1408\" data-end=\"1427\"\u003eProbe Selection\u003c\/strong\u003e: Choose the correct \u003cstrong data-start=\"1448\" data-end=\"1477\"\u003eprobe type (rod or cable)\u003c\/strong\u003e and length based on tank height and installation conditions. This improves measurement stability.\u003c\/p\u003e\n\u003cp data-start=\"1579\" data-end=\"1693\"\u003e• \u003cstrong data-start=\"1581\" data-end=\"1602\"\u003eMedium Properties\u003c\/strong\u003e: The liquid must have a sufficient \u003cstrong data-start=\"1638\" data-end=\"1661\"\u003edielectric constant\u003c\/strong\u003e for proper signal reflection.\u003c\/p\u003e\n\u003cp data-start=\"1695\" data-end=\"1801\"\u003e• \u003cstrong data-start=\"1697\" data-end=\"1722\"\u003eInstallation Position\u003c\/strong\u003e: Ensure proper mounting to avoid internal obstructions or false reflections.\u003c\/p\u003e\n\u003ch2 data-section-id=\"v8ef4e\" data-start=\"1847\" data-end=\"1876\"\u003eWhy Choose the VEGAFLEX 83\u003c\/h2\u003e\n\u003cp data-start=\"1878\" data-end=\"2077\"\u003e• \u003cstrong data-start=\"1880\" data-end=\"1907\"\u003ePrecise TDR Measurement\u003c\/strong\u003e\u003cbr data-start=\"1907\" data-end=\"1910\"\u003eThe VEGAFLEX 83 uses \u003cstrong data-start=\"1931\" data-end=\"1949\"\u003eTDR technology\u003c\/strong\u003e to measure level and interface accurately. It calculates the signal reflection time to deliver stable and repeatable results.\u003c\/p\u003e\n\u003cp data-start=\"2079\" data-end=\"2257\"\u003e• \u003cstrong data-start=\"2081\" data-end=\"2120\"\u003eOptimized for Interface Measurement\u003c\/strong\u003e\u003cbr data-start=\"2120\" data-end=\"2123\"\u003eIt reliably detects \u003cstrong data-start=\"2143\" data-end=\"2179\"\u003einterfaces such as oil and water\u003c\/strong\u003e. Therefore, it is ideal for separators, storage tanks, and process vessels.\u003c\/p\u003e\n\u003cp data-start=\"2259\" data-end=\"2450\"\u003e• \u003cstrong data-start=\"2261\" data-end=\"2303\"\u003eStrong Performance in Harsh Conditions\u003c\/strong\u003e\u003cbr data-start=\"2303\" data-end=\"2306\"\u003eThe sensor works well in \u003cstrong data-start=\"2331\" data-end=\"2390\"\u003ehigh temperatures, high pressures, and aggressive media\u003c\/strong\u003e. As a result, it meets the needs of demanding industries.\u003c\/p\u003e\n\u003cp data-start=\"2452\" data-end=\"2618\"\u003e• \u003cstrong data-start=\"2454\" data-end=\"2480\"\u003eFlexible Probe Options\u003c\/strong\u003e\u003cbr data-start=\"2480\" data-end=\"2483\"\u003eYou can select \u003cstrong data-start=\"2498\" data-end=\"2521\"\u003erod or cable probes\u003c\/strong\u003e based on your application. This flexibility simplifies installation and improves adaptability.\u003c\/p\u003e\n\u003cp data-start=\"2620\" data-end=\"2785\"\u003e• \u003cstrong data-start=\"2622\" data-end=\"2648\"\u003eLow Maintenance Design\u003c\/strong\u003e\u003cbr data-start=\"2648\" data-end=\"2651\"\u003eThe device has \u003cstrong data-start=\"2666\" data-end=\"2685\"\u003eno moving parts\u003c\/strong\u003e, which reduces wear. In addition, it ensures long-term stable operation with minimal maintenance.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2845\" data-end=\"2851\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2853\" data-end=\"3067\"\u003e\u003cstrong data-start=\"2853\" data-end=\"2906\"\u003eQ: What applications is the VEGAFLEX 83 best for?\u003c\/strong\u003e\u003cbr data-start=\"2906\" data-end=\"2909\"\u003eA: It is ideal for \u003cstrong data-start=\"2928\" data-end=\"2963\"\u003elevel and interface measurement\u003c\/strong\u003e in industries such as oil \u0026amp; gas, chemical processing, and storage tanks with \u003cstrong data-start=\"3041\" data-end=\"3064\"\u003emulti-phase liquids\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3069\" data-end=\"3285\"\u003e\u003cstrong data-start=\"3069\" data-end=\"3105\"\u003eQ: How does TDR technology work?\u003c\/strong\u003e\u003cbr data-start=\"3105\" data-end=\"3108\"\u003eA: The sensor sends \u003cstrong data-start=\"3128\" data-end=\"3154\"\u003eelectromagnetic pulses\u003c\/strong\u003e along the probe. When the signal reaches a boundary, it reflects back. The device calculates the level based on the travel time.\u003c\/p\u003e\n\u003cp data-start=\"3287\" data-end=\"3451\"\u003e\u003cstrong data-start=\"3287\" data-end=\"3333\"\u003eQ: Can it measure oil and water interface?\u003c\/strong\u003e\u003cbr data-start=\"3333\" data-end=\"3336\"\u003eA: Yes. The VEGAFLEX 83 accurately measures \u003cstrong data-start=\"3380\" data-end=\"3413\"\u003einterfaces like oil and water\u003c\/strong\u003e, even under challenging conditions.\u003c\/p\u003e\n\u003cp data-start=\"3453\" data-end=\"3624\"\u003e\u003cstrong data-start=\"3453\" data-end=\"3509\"\u003eQ: Is it suitable for high-temperature environments?\u003c\/strong\u003e\u003cbr data-start=\"3509\" data-end=\"3512\"\u003eA: Yes. It is designed for \u003cstrong data-start=\"3539\" data-end=\"3590\"\u003ehigh-temperature and high-pressure applications\u003c\/strong\u003e, ensuring reliable performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":43358209769533,"sku":null,"price":1780.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/1_25f4cf44-a5b5-49c5-9f1e-751ee85495f0.png?v=1784256288","url":"https:\/\/proinstru.com\/products\/vega-vegaflex-83-tdr-level-and-interface-sensor","provider":"Process Instrument","version":"1.0","type":"link"}