{"product_id":"vega-vegadif-85-differential-pressure-transmitter","title":"VEGA VEGADIF 85 Differential Pressure Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"700\" data-end=\"736\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"738\" data-end=\"924\"\u003eThe \u003cstrong data-start=\"742\" data-end=\"795\"\u003eVEGA VEGADIF 85 Differential Pressure Transmitter\u003c\/strong\u003e is a high-precision industrial measurement device designed for differential pressure applications in liquids, gases, and vapors.\u003c\/p\u003e\n\u003cp data-start=\"926\" data-end=\"1234\"\u003eIt is widely used for \u003cstrong data-start=\"948\" data-end=\"992\"\u003elevel measurement in pressurized vessels\u003c\/strong\u003e, \u003cstrong data-start=\"994\" data-end=\"1036\"\u003eflow measurement with primary elements\u003c\/strong\u003e, \u003cstrong data-start=\"1038\" data-end=\"1059\"\u003efilter monitoring\u003c\/strong\u003e, and \u003cstrong data-start=\"1065\" data-end=\"1099\"\u003edensity or interface detection\u003c\/strong\u003e. By measuring the pressure difference between two process points, it provides stable and reliable process data for automation systems.\u003c\/p\u003e\n\u003cp data-start=\"1236\" data-end=\"1564\"\u003eWith a robust metallic measuring diaphragm and high overload resistance, VEGADIF 85 delivers long-term stability even under harsh industrial conditions. It is commonly integrated into chemical plants, oil \u0026amp; gas facilities, and power generation systems where accurate \u003cstrong data-start=\"1503\" data-end=\"1551\"\u003eindustrial differential pressure measurement\u003c\/strong\u003e is critical.\u003c\/p\u003e\n\u003cp data-start=\"1566\" data-end=\"1749\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1597\" data-end=\"1634\"\u003edifferential pressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1636\" data-end=\"1654\"\u003eDP transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1656\" data-end=\"1684\"\u003elevel measurement sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1686\" data-end=\"1718\"\u003eflow measurement transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1720\" data-end=\"1749\"\u003eVEGA pressure transmitter\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1751\" data-end=\"1754\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1756\" data-end=\"1772\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1774\" data-end=\"2189\"\u003e• High-precision differential pressure measurement\u003cbr data-start=\"1824\" data-end=\"1827\"\u003e• Suitable for liquids, gases, and vapors\u003cbr data-start=\"1868\" data-end=\"1871\"\u003e• Integrated overload protection diaphragm\u003cbr data-start=\"1913\" data-end=\"1916\"\u003e• Multivariable measurement capability (DP + absolute pressure)\u003cbr data-start=\"1979\" data-end=\"1982\"\u003e• Accuracy up to ±0.065%\u003cbr data-start=\"2006\" data-end=\"2009\"\u003e• Supports HART, Profibus PA, Foundation Fieldbus\u003cbr data-start=\"2058\" data-end=\"2061\"\u003e• High process pressure resistance up to 400 bar\u003cbr data-start=\"2109\" data-end=\"2112\"\u003e• SIL2 safety certification available \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2191\" data-end=\"2194\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"2196\" data-end=\"2222\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2224\" data-end=\"2498\"\u003e\n\u003cli data-section-id=\"1tclxpy\" data-start=\"2224\" data-end=\"2262\"\u003ePressurized tank level measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1h630q8\" data-start=\"2263\" data-end=\"2303\"\u003eFlow measurement with orifice plates\u003c\/li\u003e\n\u003cli data-section-id=\"5wjnms\" data-start=\"2304\" data-end=\"2334\"\u003eFilter clogging monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1u0vjpw\" data-start=\"2335\" data-end=\"2372\"\u003eDensity and interface measurement\u003c\/li\u003e\n\u003cli data-section-id=\"wsgffl\" data-start=\"2373\" data-end=\"2404\"\u003eOil and gas process systems\u003c\/li\u003e\n\u003cli data-section-id=\"6gyw6r\" data-start=\"2405\" data-end=\"2435\"\u003eChemical processing plants\u003c\/li\u003e\n\u003cli data-section-id=\"1sm2t9j\" data-start=\"2436\" data-end=\"2464\"\u003ePower generation systems\u003c\/li\u003e\n\u003cli data-section-id=\"xwcxty\" data-start=\"2465\" data-end=\"2498\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2500\" data-end=\"2503\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2505\" data-end=\"2538\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2540\" data-end=\"2577\"\u003eBefore selecting VEGADIF 85, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2579\" data-end=\"2890\"\u003e\n\u003cli data-section-id=\"1c5wyre\" data-start=\"2579\" data-end=\"2619\"\u003eRequired differential pressure range\u003c\/li\u003e\n\u003cli data-section-id=\"1279vuk\" data-start=\"2620\" data-end=\"2659\"\u003eProcess medium (liquid, gas, vapor)\u003c\/li\u003e\n\u003cli data-section-id=\"1nmgtrj\" data-start=\"2660\" data-end=\"2706\"\u003eStatic pressure conditions (up to 400 bar)\u003c\/li\u003e\n\u003cli data-section-id=\"7mmwp4\" data-start=\"2707\" data-end=\"2750\"\u003eProcess temperature range (up to 400°C)\u003c\/li\u003e\n\u003cli data-section-id=\"1cqzo4x\" data-start=\"2751\" data-end=\"2795\"\u003eMounting position (HP \/ LP side routing)\u003c\/li\u003e\n\u003cli data-section-id=\"tgmx08\" data-start=\"2796\" data-end=\"2841\"\u003eOutput protocol (4–20mA \/ HART \/ PA \/ FF)\u003c\/li\u003e\n\u003cli data-section-id=\"1rpey40\" data-start=\"2842\" data-end=\"2890\"\u003eNeed for SIL or hazardous area certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2892\" data-end=\"2895\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2897\" data-end=\"2911\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2913\" data-end=\"3097\"\u003e\u003cstrong data-start=\"2913\" data-end=\"2953\"\u003eQ: What is VEGA VEGADIF 85 used for?\u003c\/strong\u003e\u003cbr data-start=\"2953\" data-end=\"2956\"\u003eA: It is used for differential pressure measurement in level, flow, filter, and density applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3099\" data-end=\"3220\"\u003e\u003cstrong data-start=\"3099\" data-end=\"3144\"\u003eQ: Can VEGADIF 85 measure level directly?\u003c\/strong\u003e\u003cbr data-start=\"3144\" data-end=\"3147\"\u003eA: Yes, it is commonly used for level measurement in pressurized vessels.\u003c\/p\u003e\n\u003cp data-start=\"3222\" data-end=\"3332\"\u003e\u003cstrong data-start=\"3222\" data-end=\"3265\"\u003eQ: Is it suitable for flow measurement?\u003c\/strong\u003e\u003cbr data-start=\"3265\" data-end=\"3268\"\u003eA: Yes, it works with primary flow elements like orifice plates.\u003c\/p\u003e\n\u003cp data-start=\"3334\" data-end=\"3455\"\u003e\u003cstrong data-start=\"3334\" data-end=\"3367\"\u003eQ: What media can it measure?\u003c\/strong\u003e\u003cbr data-start=\"3367\" data-end=\"3370\"\u003eA: It can measure liquids, gases, and vapors. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3457\" data-end=\"3544\"\u003e\u003cstrong data-start=\"3457\" data-end=\"3499\"\u003eQ: What is the accuracy of VEGADIF 85?\u003c\/strong\u003e\u003cbr data-start=\"3499\" data-end=\"3502\"\u003eA: It offers high precision up to ±0.065%.\u003c\/p\u003e\n\u003cp data-start=\"3546\" data-end=\"3642\"\u003e\u003cstrong data-start=\"3546\" data-end=\"3588\"\u003eQ: Does it support hazardous area use?\u003c\/strong\u003e\u003cbr data-start=\"3588\" data-end=\"3591\"\u003eA: Yes, ATEX, IECEx and SIL2 options are available.\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":43318284943421,"sku":null,"price":1150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/vegadif85-differential-pressure-transmitter-product-view.png?v=1783050387","url":"https:\/\/proinstru.com\/products\/vega-vegadif-85-differential-pressure-transmitter","provider":"Process Instrument","version":"1.0","type":"link"}