{"product_id":"vega-vegacap-63-capacitive-rod-probe-level-switch","title":"VEGA VEGACAP 63 Capacitive Rod Probe Level Switch","description":"\u003cp data-start=\"244\" data-end=\"442\"\u003eThe \u003cstrong data-start=\"248\" data-end=\"288\"\u003eVEGA VEGACAP 63 Capacitive Rod Probe\u003c\/strong\u003e is a \u003cstrong data-start=\"294\" data-end=\"316\"\u003epoint level switch\u003c\/strong\u003e designed for \u003cstrong data-start=\"330\" data-end=\"385\"\u003ereliable level detection of liquids and bulk solids\u003c\/strong\u003e, especially in \u003cstrong data-start=\"401\" data-end=\"441\"\u003enon-abrasive industrial applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"444\" data-end=\"687\"\u003eIt uses \u003cstrong data-start=\"452\" data-end=\"489\"\u003ecapacitive measurement technology\u003c\/strong\u003e, detecting level changes based on dielectric variation between the probe and medium. The probe is \u003cstrong data-start=\"588\" data-end=\"620\"\u003efully insulated (PE or PTFE)\u003c\/strong\u003e, ensuring stable operation even in demanding process environments.\u003c\/p\u003e\n\u003cp data-start=\"689\" data-end=\"851\"\u003eWith a \u003cstrong data-start=\"696\" data-end=\"765\"\u003erobust mechanical design and flexible probe length up to 6 meters\u003c\/strong\u003e, VEGACAP 63 provides \u003cstrong data-start=\"787\" data-end=\"850\"\u003ereliable switching signals for high and low level detection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"853\" data-end=\"981\"\u003eTypical applications include \u003cstrong data-start=\"882\" data-end=\"980\"\u003etank overflow protection, silo level monitoring, separator vessels, and process safety systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"983\" data-end=\"1155\"\u003eNot Recommended For:\u003cbr data-start=\"1003\" data-end=\"1006\"\u003e• Continuous level measurement (use VEGACAL or radar systems instead)\u003cbr data-start=\"1075\" data-end=\"1078\"\u003e• Strongly abrasive or heavily coating media without proper probe selection\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/instrugauge.com\/wp-content\/uploads\/34142-EN-Chapter-VEGACAP-4.pdf\"\u003eVEGACAP 63 Capacitive rod probe for level detection\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-content-block\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1190\" data-end=\"1209\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1211\" data-end=\"1859\"\u003e• Confirm \u003cstrong data-start=\"1221\" data-end=\"1241\"\u003eapplication type\u003c\/strong\u003e: point level detection (high\/low switching only)\u003cbr data-start=\"1290\" data-end=\"1293\"\u003e• Identify \u003cstrong data-start=\"1304\" data-end=\"1319\"\u003emedium type\u003c\/strong\u003e: liquids or bulk solids (non-abrasive preferred)\u003cbr data-start=\"1368\" data-end=\"1371\"\u003e• Select \u003cstrong data-start=\"1380\" data-end=\"1417\"\u003eprobe version and insulation type\u003c\/strong\u003e (PE or PTFE coating)\u003cbr data-start=\"1438\" data-end=\"1441\"\u003e• Define required \u003cstrong data-start=\"1459\" data-end=\"1475\"\u003eprobe length\u003c\/strong\u003e, up to approx. 6 m depending on tank depth \u003cbr data-start=\"1556\" data-end=\"1559\"\u003e• Choose \u003cstrong data-start=\"1568\" data-end=\"1590\"\u003eprocess connection\u003c\/strong\u003e, such as G½ or flange (DN25+) \u003cbr data-start=\"1658\" data-end=\"1661\"\u003e• Verify \u003cstrong data-start=\"1670\" data-end=\"1707\"\u003etemperature range (-50 to +200°C)\u003c\/strong\u003e and pressure conditions \u003cbr data-start=\"1769\" data-end=\"1772\"\u003e• Select required \u003cstrong data-start=\"1790\" data-end=\"1805\"\u003eoutput type\u003c\/strong\u003e: relay, transistor (PNP\/NPN), or two-wire switching\u003c\/p\u003e\n\u003ch3 data-section-id=\"enqx46\" data-start=\"1894\" data-end=\"1923\"\u003eWhy Choose the VEGACAP 63\u003c\/h3\u003e\n\u003cp data-start=\"1925\" data-end=\"2090\"\u003e• \u003cstrong data-start=\"1927\" data-end=\"1961\"\u003eReliable Point Level Switching\u003c\/strong\u003e\u003cbr data-start=\"1961\" data-end=\"1964\"\u003eCapacitive technology detects level changes based on dielectric differences. Therefore, it works across a wide range of media.\u003c\/p\u003e\n\u003cp data-start=\"2092\" data-end=\"2306\"\u003e• \u003cstrong data-start=\"2094\" data-end=\"2130\"\u003eFully Insulated Rod Probe Design\u003c\/strong\u003e\u003cbr data-start=\"2130\" data-end=\"2133\"\u003eThe probe is completely insulated with PE or PTFE. As a result, it ensures stable operation and reduces interference from the medium.\u003c\/p\u003e\n\u003cp data-start=\"2308\" data-end=\"2504\"\u003e• \u003cstrong data-start=\"2310\" data-end=\"2350\"\u003eSuitable for Liquids and Bulk Solids\u003c\/strong\u003e\u003cbr data-start=\"2350\" data-end=\"2353\"\u003eIt can be used for both liquid tanks and solid silos. Consequently, it provides strong application flexibility.\u003c\/p\u003e\n\u003cp data-start=\"2506\" data-end=\"2698\"\u003e• \u003cstrong data-start=\"2508\" data-end=\"2556\"\u003eFlexible Installation up to 6 m Probe Length\u003c\/strong\u003e\u003cbr data-start=\"2556\" data-end=\"2559\"\u003eProbe length can be adapted to tank size. Therefore, it is suitable for various industrial vessels.\u003c\/p\u003e\n\u003cp data-start=\"2700\" data-end=\"2864\"\u003e• \u003cstrong data-start=\"2702\" data-end=\"2736\"\u003eRobust Mechanical Construction\u003c\/strong\u003e\u003cbr data-start=\"2736\" data-end=\"2739\"\u003eDesigned for long service life with low maintenance requirements. This ensures reliable operation in industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"2866\" data-end=\"3025\"\u003e• \u003cstrong data-start=\"2868\" data-end=\"2909\"\u003eWide Industrial Process Compatibility\u003c\/strong\u003e\u003cbr data-start=\"2909\" data-end=\"2912\"\u003eHandles pressures from \u003cstrong data-start=\"2935\" data-end=\"2951\"\u003e-1 to 64 bar\u003c\/strong\u003e and temperatures up to \u003cstrong data-start=\"2975\" data-end=\"2984\"\u003e200°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3027\" data-end=\"3169\"\u003e• \u003cstrong data-start=\"3029\" data-end=\"3077\"\u003eMultiple Output Options for Easy Integration\u003c\/strong\u003e\u003cbr data-start=\"3077\" data-end=\"3080\"\u003eSupports relay, transistor, and electronic switching outputs for PLC and control systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3207\" data-end=\"3214\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3216\" data-end=\"3344\"\u003e\u003cstrong data-start=\"3216\" data-end=\"3251\"\u003eQ: What is VEGACAP 63 used for?\u003c\/strong\u003e\u003cbr data-start=\"3251\" data-end=\"3254\"\u003eA: It is used for \u003cstrong data-start=\"3272\" data-end=\"3324\"\u003epoint level detection (high\/low level switching)\u003c\/strong\u003e in tanks and silos.\u003c\/p\u003e\n\u003cp data-start=\"3346\" data-end=\"3462\"\u003e\u003cstrong data-start=\"3346\" data-end=\"3385\"\u003eQ: Can it measure continuous level?\u003c\/strong\u003e\u003cbr data-start=\"3385\" data-end=\"3388\"\u003eA: No. It is a \u003cstrong data-start=\"3403\" data-end=\"3419\"\u003elevel switch\u003c\/strong\u003e, not a continuous measurement transmitter.\u003c\/p\u003e\n\u003cp data-start=\"3464\" data-end=\"3578\"\u003e\u003cstrong data-start=\"3464\" data-end=\"3497\"\u003eQ: What media can it measure?\u003c\/strong\u003e\u003cbr data-start=\"3497\" data-end=\"3500\"\u003eA: It measures \u003cstrong data-start=\"3515\" data-end=\"3542\"\u003eliquids and bulk solids\u003c\/strong\u003e, especially non-abrasive materials.\u003c\/p\u003e\n\u003cp data-start=\"3580\" data-end=\"3740\"\u003e\u003cstrong data-start=\"3580\" data-end=\"3625\"\u003eQ: Is it suitable for harsh environments?\u003c\/strong\u003e\u003cbr data-start=\"3625\" data-end=\"3628\"\u003eA: Yes. It supports \u003cstrong data-start=\"3648\" data-end=\"3698\"\u003eindustrial pressure and temperature conditions\u003c\/strong\u003e, with robust insulation and construction.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":43371784208445,"sku":null,"price":1150.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/vega-vegacap-63-capacitive-rod-probe.png?v=1784538768","url":"https:\/\/proinstru.com\/products\/vega-vegacap-63-capacitive-rod-probe-level-switch","provider":"Process Instrument","version":"1.0","type":"link"}