{"product_id":"vega-vegabar-38-pressure-sensor-with-switching-function","title":"VEGA VEGABAR 38 Pressure Sensor with Switching Function","description":"\u003cp data-start=\"227\" data-end=\"423\"\u003eThe \u003cstrong data-start=\"231\" data-end=\"290\"\u003eVEGA VEGABAR 38 Pressure Sensor with Switching Function\u003c\/strong\u003e is a \u003cstrong data-start=\"296\" data-end=\"346\"\u003ecompact pressure sensor and switch combination\u003c\/strong\u003e designed for \u003cstrong data-start=\"360\" data-end=\"422\"\u003ereliable pressure monitoring of liquids, gases, and vapors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"425\" data-end=\"720\"\u003eEquipped with a \u003cstrong data-start=\"441\" data-end=\"467\"\u003eceramic measuring cell\u003c\/strong\u003e, it offers \u003cstrong data-start=\"479\" data-end=\"531\"\u003ehigh overload resistance and long-term stability\u003c\/strong\u003e, even in demanding industrial environments. In addition, the integrated \u003cstrong data-start=\"604\" data-end=\"660\"\u003eswitching output (PNP\/NPN) and IO-Link communication\u003c\/strong\u003e enable seamless integration into modern automation systems.\u003c\/p\u003e\n\u003cp data-start=\"722\" data-end=\"868\"\u003eIts \u003cstrong data-start=\"726\" data-end=\"771\"\u003e360° status display and on-site operation\u003c\/strong\u003e make commissioning and monitoring simple, especially for OEM equipment and skid-mounted systems.\u003c\/p\u003e\n\u003cp data-start=\"870\" data-end=\"984\"\u003eTypical applications include \u003cstrong data-start=\"899\" data-end=\"983\"\u003epump protection, tank pressure monitoring, process control, and hygienic systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"986\" data-end=\"1184\"\u003eNot Recommended For:\u003cbr data-start=\"1006\" data-end=\"1009\"\u003e• Ultra-high precision measurement requiring advanced transmitters (e.g. VEGABAR 80 series)\u003cbr data-start=\"1100\" data-end=\"1103\"\u003e• Non-industrial applications requiring only basic mechanical pressure switches\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/instrugauge.com\/wp-content\/uploads\/55579-EN-Product-information-VEGABAR-18-19-28-29-38-39-11.pdf\"\u003eVEGABAR 38 Product information\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-content-block\"\u003e\n\u003cdiv class=\"product-content-block\"\u003e\n\u003cdiv class=\"product-content-block\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1219\" data-end=\"1238\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1240\" data-end=\"1459\"\u003e• Confirm the \u003cstrong data-start=\"1254\" data-end=\"1272\"\u003eprocess medium\u003c\/strong\u003e: gases, vapors, or liquids (must be compatible with ceramic cell)\u003cbr data-start=\"1338\" data-end=\"1341\"\u003e• Select \u003cstrong data-start=\"1350\" data-end=\"1368\"\u003epressure range\u003c\/strong\u003e, typically up to industrial standard process limits\u003cbr data-start=\"1420\" data-end=\"1423\"\u003e• Choose required \u003cstrong data-start=\"1441\" data-end=\"1456\"\u003eoutput type\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1462\" data-end=\"1791\"\u003e\n\u003cli data-section-id=\"1qmrp11\" data-start=\"1462\" data-end=\"1492\"\u003eSwitching output (PNP\/NPN)\u003c\/li\u003e\n\u003cli data-section-id=\"g09pm3\" data-start=\"1495\" data-end=\"1513\"\u003eAnalog 4–20 mA\u003c\/li\u003e\n\u003cli data-section-id=\"1mavwax\" data-start=\"1516\" data-end=\"1791\"\u003eIO-Link for digital integration\u003cbr data-start=\"1549\" data-end=\"1552\"\u003e• Verify \u003cstrong data-start=\"1561\" data-end=\"1583\"\u003eprocess connection\u003c\/strong\u003e, such as G½ thread or hygienic clamp\u003cbr data-start=\"1620\" data-end=\"1623\"\u003e• Confirm \u003cstrong data-start=\"1633\" data-end=\"1676\"\u003etemperature range (up to approx. 130°C)\u003c\/strong\u003e \u003cbr data-start=\"1714\" data-end=\"1717\"\u003e• Ensure need for \u003cstrong data-start=\"1735\" data-end=\"1763\"\u003ehygienic or Ex approvals\u003c\/strong\u003e, depending on application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"f9juuj\" data-start=\"1826\" data-end=\"1855\"\u003eWhy Choose the VEGABAR 38\u003c\/h3\u003e\n\u003cp data-start=\"1857\" data-end=\"2000\"\u003e• \u003cstrong data-start=\"1859\" data-end=\"1892\"\u003eSensor + Switch in One Device\u003c\/strong\u003e\u003cbr data-start=\"1892\" data-end=\"1895\"\u003eCombines pressure measurement and switching function. Therefore, no separate pressure switch is required.\u003c\/p\u003e\n\u003cp data-start=\"2002\" data-end=\"2189\"\u003e• \u003cstrong data-start=\"2004\" data-end=\"2037\"\u003eRobust Ceramic Measuring Cell\u003c\/strong\u003e\u003cbr data-start=\"2037\" data-end=\"2040\"\u003eProvides excellent resistance to overload and vacuum conditions. As a result, long-term stability is ensured.\u003c\/p\u003e\n\u003cp data-start=\"2191\" data-end=\"2382\"\u003e• \u003cstrong data-start=\"2193\" data-end=\"2235\"\u003e360° Status Display for Fast Diagnosis\u003c\/strong\u003e\u003cbr data-start=\"2235\" data-end=\"2238\"\u003eThe color ring display shows switching status clearly from any direction, improving operator visibility.\u003c\/p\u003e\n\u003cp data-start=\"2384\" data-end=\"2567\"\u003e• \u003cstrong data-start=\"2386\" data-end=\"2425\"\u003eIO-Link Ready for Smart Integration\u003c\/strong\u003e\u003cbr data-start=\"2425\" data-end=\"2428\"\u003eSupports digital communication, enabling \u003cstrong data-start=\"2469\" data-end=\"2526\"\u003eeasy commissioning, parameterization, and diagnostics\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2569\" data-end=\"2737\"\u003e• \u003cstrong data-start=\"2571\" data-end=\"2610\"\u003eCompact Design for OEM Applications\u003c\/strong\u003e\u003cbr data-start=\"2610\" data-end=\"2613\"\u003eSmall footprint allows installation in tight systems. Consequently, it is ideal for skid builders and machine manufacturers.\u003c\/p\u003e\n\u003cp data-start=\"2739\" data-end=\"2909\"\u003e• \u003cstrong data-start=\"2741\" data-end=\"2778\"\u003eHygienic and Flexible Connections\u003c\/strong\u003e\u003cbr data-start=\"2778\" data-end=\"2781\"\u003eSupports threaded and hygienic adapters, reducing installation complexity and inventory.\u003c\/p\u003e\n\u003cp data-start=\"2911\" data-end=\"3056\"\u003e• \u003cstrong data-start=\"2913\" data-end=\"2940\"\u003eUser-Friendly Operation\u003c\/strong\u003e\u003cbr data-start=\"2940\" data-end=\"2943\"\u003eOn-site display with 3-button operation simplifies setup and maintenance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3094\" data-end=\"3101\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3103\" data-end=\"3272\"\u003e\u003cstrong data-start=\"3103\" data-end=\"3145\"\u003eQ: What is VEGABAR 38 mainly used for?\u003c\/strong\u003e\u003cbr data-start=\"3145\" data-end=\"3148\"\u003eA: It is used for \u003cstrong data-start=\"3166\" data-end=\"3211\"\u003epressure monitoring and switching control\u003c\/strong\u003e in industrial processes such as pumps, tanks, and pipelines.\u003c\/p\u003e\n\u003cp data-start=\"3274\" data-end=\"3432\"\u003e\u003cstrong data-start=\"3274\" data-end=\"3331\"\u003eQ: Is it a pressure transmitter or a pressure switch?\u003c\/strong\u003e\u003cbr data-start=\"3331\" data-end=\"3334\"\u003eA: It is \u003cstrong data-start=\"3343\" data-end=\"3351\"\u003eboth\u003c\/strong\u003e — a pressure sensor with integrated switching output and optional analog signal.\u003c\/p\u003e\n\u003cp data-start=\"3434\" data-end=\"3618\"\u003e\u003cstrong data-start=\"3434\" data-end=\"3467\"\u003eQ: What media can it measure?\u003c\/strong\u003e\u003cbr data-start=\"3467\" data-end=\"3470\"\u003eA: It measures \u003cstrong data-start=\"3485\" data-end=\"3515\"\u003eliquids, gases, and vapors\u003c\/strong\u003e, provided they are compatible with the ceramic measuring cell.\u003c\/p\u003e\n\u003cp data-start=\"3620\" data-end=\"3792\"\u003e\u003cstrong data-start=\"3620\" data-end=\"3665\"\u003eQ: Does it support digital communication?\u003c\/strong\u003e\u003cbr data-start=\"3665\" data-end=\"3668\"\u003eA: Yes. It supports \u003cstrong data-start=\"3688\" data-end=\"3699\"\u003eIO-Link\u003c\/strong\u003e, enabling smart factory integration and diagnostics.\u003c\/p\u003e\n\u003cp data-start=\"3820\" data-end=\"3921\"\u003eNot sure if the \u003cstrong data-start=\"3836\" data-end=\"3890\"\u003eVEGABAR 38 pressure sensor with switching function\u003c\/strong\u003e is suitable for your system?\u003c\/p\u003e\n\u003cp data-start=\"3923\" data-end=\"4063\"\u003eSend us your \u003cstrong data-start=\"3936\" data-end=\"4010\"\u003epressure range, medium, and control requirement (switching or IO-Link)\u003c\/strong\u003e, and we will help you select the best configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":43358447665213,"sku":null,"price":435.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/vega-vegabar-38-pressure-sensor-switching-function.png?v=1784271916","url":"https:\/\/proinstru.com\/products\/vega-vegabar-38-pressure-sensor-with-switching-function","provider":"Process Instrument","version":"1.0","type":"link"}