{"product_id":"siemens-sitrans-th100-temperature-transmitter","title":"Siemens SITRANS TH100 Temperature Transmitter","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eSiemens SITRANS TH100 7NG3211 Temperature Transmitter\u003c\/strong\u003e is a compact \u003cstrong\u003ehead-mounted temperature transmitter\u003c\/strong\u003e designed for precise measurement using \u003cstrong\u003ePt100 resistance temperature detectors (RTD)\u003c\/strong\u003e. It converts the sensor signal into a standardized \u003cstrong\u003e4–20 mA output\u003c\/strong\u003e for reliable integration into industrial automation systems. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for installation in \u003cstrong\u003eDIN B connection heads\u003c\/strong\u003e, the SITRANS TH100 provides a cost-effective solution for temperature monitoring in general industrial applications. It supports programmable measuring ranges and two-wire operation, making it suitable for a wide range of temperature measurement requirements. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter is available in versions with optional explosion protection, including ATEX intrinsic safety and FM approvals, for applications requiring hazardous area compliance. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eCompact head-mounted temperature transmitter\u003c\/li\u003e\n\u003cli\u003eDesigned for Pt100 RTD temperature sensors\u003c\/li\u003e\n\u003cli\u003eStandard 4–20 mA two-wire output\u003c\/li\u003e\n\u003cli\u003eProgrammable measuring range\u003c\/li\u003e\n\u003cli\u003eInstallation in DIN B connection heads\u003c\/li\u003e\n\u003cli\u003eSupports 2-wire, 3-wire, and 4-wire Pt100 connection methods\u003c\/li\u003e\n\u003cli\u003eTemperature-linear output signal\u003c\/li\u003e\n\u003cli\u003eReliable operation in industrial environments\u003c\/li\u003e\n\u003cli\u003eOptional ATEX and FM explosion protection versions\u003c\/li\u003e\n\u003cli\u003eEasy replacement of conventional temperature transmitters\u003cbr\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Overview\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSITRANS TH100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e7NG3211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sensor\u003c\/td\u003e\n\u003ctd\u003ePt100 (IEC 60751)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eHead transmitter, DIN B connection head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTwo-wire loop powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eAnalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Connection\u003c\/td\u003e\n\u003ctd\u003e2 \/ 3 \/ 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial temperature measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eApplications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eProcess temperature monitoring\u003c\/li\u003e\n\u003cli\u003eChemical industry equipment\u003c\/li\u003e\n\u003cli\u003eWater treatment systems\u003c\/li\u003e\n\u003cli\u003eMachinery temperature measurement\u003c\/li\u003e\n\u003cli\u003eHVAC and building automation\u003c\/li\u003e\n\u003cli\u003eIndustrial heating systems\u003c\/li\u003e\n\u003cli\u003eFood and beverage processing\u003c\/li\u003e\n\u003cli\u003ePharmaceutical equipment\u003c\/li\u003e\n\u003cli\u003eGeneral process instrumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eSelection Notes\u003c\/h1\u003e\n\u003cp\u003eBefore selecting the \u003cstrong\u003eSiemens SITRANS TH100 Temperature Transmitter\u003c\/strong\u003e, consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequired Pt100 sensor type\u003c\/li\u003e\n\u003cli\u003eTemperature measuring range\u003c\/li\u003e\n\u003cli\u003eConnection head size and installation method\u003c\/li\u003e\n\u003cli\u003eHazardous area certification requirements\u003c\/li\u003e\n\u003cli\u003eRequired output signal\u003c\/li\u003e\n\u003cli\u003eEnvironmental temperature conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRecommended selection:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eStandard industrial applications → SITRANS TH100 7NG3211\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHazardous environments → Select ATEX\/FM approved version\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAdvanced digital communication requirements → Consider SITRANS TH320\/TH420 series\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eFAQ\u003c\/h1\u003e\n\u003ch3\u003eQ1: What sensor does Siemens SITRANS TH100 support?\u003c\/h3\u003e\n\u003cp\u003eThe SITRANS TH100 is designed for \u003cstrong\u003ePt100 resistance temperature sensors according to IEC 60751\u003c\/strong\u003e. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eQ2: What output signal does SITRANS TH100 provide?\u003c\/h3\u003e\n\u003cp\u003eIt provides a standard \u003cstrong\u003e4–20 mA two-wire output\u003c\/strong\u003e, suitable for connection to PLC, DCS, and process control systems. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eQ3: Where is SITRANS TH100 installed?\u003c\/h3\u003e\n\u003cp\u003eThe transmitter is installed inside \u003cstrong\u003eDIN B type connection heads\u003c\/strong\u003e and is commonly used with industrial RTD temperature sensors.\u003c\/p\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":43421154607165,"sku":null,"price":250.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/siemens-sitrans-th100-temperature-transmitter.png?v=1785747061","url":"https:\/\/proinstru.com\/products\/siemens-sitrans-th100-temperature-transmitter","provider":"Process Instrument","version":"1.0","type":"link"}