{"product_id":"siemens-sitrans-fms500-electromagnetic-flow-sensor","title":"Siemens SITRANS FMS500 Electromagnetic Flow Sensor","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eSiemens SITRANS FMS500 7ME653 Electromagnetic Flow Sensor\u003c\/strong\u003e is a reliable flow measurement solution specially designed for \u003cstrong\u003ewater and wastewater applications\u003c\/strong\u003e. Based on proven electromagnetic flow technology, it provides accurate volume flow measurement for groundwater, drinking water, wastewater, sewage, and sludge applications. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeaturing a robust design with no moving parts, the \u003cstrong\u003eSITRANS FMS500\u003c\/strong\u003e delivers long-term stability and low maintenance requirements. Its coned sensor design improves low-flow accuracy, making it especially suitable for leak detection and water distribution network monitoring. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor can be combined with Siemens \u003cstrong\u003eSITRANS FMT020 transmitter\u003c\/strong\u003e to create a complete electromagnetic flow measurement system for water management and industrial applications. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eElectromagnetic flow measurement technology based on Faraday's law\u003c\/li\u003e\n\u003cli\u003eDesigned for water and wastewater applications\u003c\/li\u003e\n\u003cli\u003eSuitable for drinking water, sewage, sludge, and industrial water\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity for low-flow measurement and leak detection\u003c\/li\u003e\n\u003cli\u003eNo moving parts for reduced maintenance\u003c\/li\u003e\n\u003cli\u003eSuitable for direct burial and constant flooding environments\u003c\/li\u003e\n\u003cli\u003eWide measuring range from DN15 to DN1200 (½\" to 48\")\u003c\/li\u003e\n\u003cli\u003eSupports drinking water approvals including NSF\/ANSI 61 and other regional certifications\u003c\/li\u003e\n\u003cli\u003eCompatible with SITRANS FMT020 transmitter\u003c\/li\u003e\n\u003cli\u003eAvailable for water distribution and utility networks\u003cbr\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eApplications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eDrinking water measurement\u003c\/li\u003e\n\u003cli\u003eWater extraction systems\u003c\/li\u003e\n\u003cli\u003eWater distribution networks\u003c\/li\u003e\n\u003cli\u003eWastewater treatment plants\u003c\/li\u003e\n\u003cli\u003eSewage flow monitoring\u003c\/li\u003e\n\u003cli\u003eSludge measurement\u003c\/li\u003e\n\u003cli\u003eIrrigation systems\u003c\/li\u003e\n\u003cli\u003eUtility water management\u003c\/li\u003e\n\u003cli\u003eIndustrial water process monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eSelection Notes\u003c\/h1\u003e\n\u003cp\u003eBefore selecting the \u003cstrong\u003eSiemens SITRANS FMS500 Flow Sensor\u003c\/strong\u003e, consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMedium conductivity requirements\u003c\/li\u003e\n\u003cli\u003ePipe diameter and installation conditions\u003c\/li\u003e\n\u003cli\u003eDrinking water approval requirements\u003c\/li\u003e\n\u003cli\u003eRequired accuracy and calibration options\u003c\/li\u003e\n\u003cli\u003eLiner and electrode material selection\u003c\/li\u003e\n\u003cli\u003eNeed for compact or remote transmitter installation\u003c\/li\u003e\n\u003cli\u003eEnvironmental conditions such as burial or flooding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCorrect configuration ensures accurate and reliable water flow measurement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFAQ\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is Siemens SITRANS FMS500 used for?\u003c\/strong\u003e\u003cbr\u003eSITRANS FMS500 is designed for electromagnetic flow measurement in water extraction, drinking water, wastewater treatment, and distribution networks. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can SITRANS FMS500 measure low flow rates?\u003c\/strong\u003e\u003cbr\u003eYes. Its coned sensor design improves low-flow accuracy and supports applications such as water leak detection. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does SITRANS FMS500 have moving parts?\u003c\/strong\u003e\u003cbr\u003eNo. The electromagnetic sensor design has no moving parts, helping reduce maintenance requirements and improve long-term reliability.\u003c\/p\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":43421029793853,"sku":null,"price":600.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/siemens-sitrans-fms500-electromagnetic-flow-sensor.png?v=1785740667","url":"https:\/\/proinstru.com\/products\/siemens-sitrans-fms500-electromagnetic-flow-sensor","provider":"Process Instrument","version":"1.0","type":"link"}