{"product_id":"siemens-sitrans-fc620-fc640-coriolis-flowmeter","title":"Siemens SITRANS FC620 FC640 Coriolis Flowmeter","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eSiemens SITRANS FC620 \/ FC640 7ME446 Coriolis Flowmeter\u003c\/strong\u003e is a rugged multi-parameter flow measurement system designed for \u003cstrong\u003ehigh temperature, high pressure, and challenging industrial applications\u003c\/strong\u003e. It combines the \u003cstrong\u003eFCS600 Coriolis sensor\u003c\/strong\u003e with either the \u003cstrong\u003eFCT020 transmitter (FC620)\u003c\/strong\u003e or \u003cstrong\u003eFCT040 transmitter (FC640)\u003c\/strong\u003e to deliver accurate mass flow, density, and process measurement. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for extreme operating conditions, the SITRANS FC620\/FC640 features durable dual curved measuring tubes, excellent vibration resistance, and corrosion-resistant materials. It is suitable for applications requiring reliable measurement performance in chemical, oil \u0026amp; gas, energy, and industrial process environments. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance Coriolis mass flow measurement technology\u003c\/li\u003e\n\u003cli\u003eDesigned for high temperature applications up to \u003cstrong\u003e350 °C (662 °F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports high pressure applications up to \u003cstrong\u003e700 bar (10,153 psi)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasures mass flow, density, and process parameters\u003c\/li\u003e\n\u003cli\u003eDual curved measuring tubes for improved stability\u003c\/li\u003e\n\u003cli\u003eWetted materials available in \u003cstrong\u003e316L stainless steel and Alloy 22\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eExcellent resistance to corrosive fluids\u003c\/li\u003e\n\u003cli\u003eAdvanced diagnostics and aeration handling capability\u003c\/li\u003e\n\u003cli\u003eCompact or remote transmitter installation options\u003c\/li\u003e\n\u003cli\u003eAvailable with flange or threaded process connections\u003cbr\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eApplications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-pressure chemical processing\u003c\/li\u003e\n\u003cli\u003ePetrochemical production\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; Gas measurement systems\u003c\/li\u003e\n\u003cli\u003eHydrogen and specialty gas applications\u003c\/li\u003e\n\u003cli\u003eIndustrial chemical transfer\u003c\/li\u003e\n\u003cli\u003ePower generation processes\u003c\/li\u003e\n\u003cli\u003eHigh-temperature fluid measurement\u003c\/li\u003e\n\u003cli\u003eCritical process control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eSelection Notes\u003c\/h1\u003e\n\u003cp\u003eBefore selecting the \u003cstrong\u003eSiemens SITRANS FC620 \/ FC640 Coriolis Flowmeter\u003c\/strong\u003e, consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequired flow range and pipe size\u003c\/li\u003e\n\u003cli\u003eMaximum operating temperature and pressure\u003c\/li\u003e\n\u003cli\u003eProcess medium characteristics\u003c\/li\u003e\n\u003cli\u003eCorrosion resistance requirements\u003c\/li\u003e\n\u003cli\u003eRequired accuracy and density measurement needs\u003c\/li\u003e\n\u003cli\u003eSensor material selection\u003c\/li\u003e\n\u003cli\u003eCompact or remote transmitter configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCorrect configuration ensures reliable measurement performance in extreme industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFAQ\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between SITRANS FC620 and FC640?\u003c\/strong\u003e\u003cbr\u003eThe SITRANS FC620 uses the FCT020 transmitter, while the SITRANS FC640 uses the advanced FCT040 transmitter combined with the FCS600 Coriolis sensor. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What makes SITRANS FC620\/FC640 suitable for high-pressure applications?\u003c\/strong\u003e\u003cbr\u003eThe flowmeter features a robust construction with durable measuring tubes and supports pressure applications up to 700 bar depending on configuration. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can SITRANS FC620\/FC640 handle high-temperature fluids?\u003c\/strong\u003e\u003cbr\u003eYes. The system is designed for demanding applications with temperature resistance up to 350 °C.\u003c\/p\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":43421004759101,"sku":null,"price":8000.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/siemens-sitrans-fc620-fc640-coriolis-flowmeter.png?v=1785740118","url":"https:\/\/proinstru.com\/products\/siemens-sitrans-fc620-fc640-coriolis-flowmeter","provider":"Process Instrument","version":"1.0","type":"link"}