{"product_id":"siemens-sitrans-fc120-fc140-coriolis-flow-meter","title":"Siemens SITRANS FC120 FC140 Coriolis Flow Meter","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eSiemens SITRANS FC120 \/ FC140 7ME441 Coriolis Flow Meter\u003c\/strong\u003e is a compact and highly accurate \u003cstrong\u003eCoriolis flow measurement system\u003c\/strong\u003e designed for low-flow applications. Featuring advanced dual curved tube technology, it provides reliable measurement of \u003cstrong\u003emass flow, density, temperature, and volume flow\u003c\/strong\u003e for liquids, gases, and mixtures. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe SITRANS FC120 and FC140 combine the \u003cstrong\u003eFCS100 Coriolis sensor\u003c\/strong\u003e with either the \u003cstrong\u003eFCT020 transmitter (FC120)\u003c\/strong\u003e or \u003cstrong\u003eFCT040 transmitter (FC140)\u003c\/strong\u003e, offering flexible configuration options for demanding industrial processes. Its compact design makes it ideal for pilot plants, laboratories, dosing systems, and applications requiring high precision at low flow rates. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy Coriolis flow measurement for low-flow applications\u003c\/li\u003e\n\u003cli\u003eMeasures liquids, gases, mixtures, emulsions, and suspensions\u003c\/li\u003e\n\u003cli\u003eDual curved tube design for excellent measurement stability\u003c\/li\u003e\n\u003cli\u003eSimultaneous measurement of mass flow, density, temperature, and volume flow\u003c\/li\u003e\n\u003cli\u003eCompact design starting from DN1 sensor size\u003c\/li\u003e\n\u003cli\u003eSuitable for dosing and batching applications\u003c\/li\u003e\n\u003cli\u003eOptional FCT020 and FCT040 transmitter versions\u003c\/li\u003e\n\u003cli\u003eAdvanced concentration measurement functions available with FCT040\u003c\/li\u003e\n\u003cli\u003eWide range of process connections including threaded and hygienic clamp options\u003c\/li\u003e\n\u003cli\u003eSuitable for pilot plants, R\u0026amp;D systems, and high-value fluid applications\u003cbr\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eApplications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003ePharmaceutical production\u003c\/li\u003e\n\u003cli\u003eChemical dosing systems\u003c\/li\u003e\n\u003cli\u003eLaboratory and pilot plant applications\u003c\/li\u003e\n\u003cli\u003eFood \u0026amp; beverage processing\u003c\/li\u003e\n\u003cli\u003eBiotechnology processes\u003c\/li\u003e\n\u003cli\u003eLiquid additive measurement\u003c\/li\u003e\n\u003cli\u003eGas flow monitoring\u003c\/li\u003e\n\u003cli\u003ePrecision batch control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eSelection Notes\u003c\/h1\u003e\n\u003cp\u003eBefore selecting the \u003cstrong\u003eSiemens SITRANS FC120 \/ FC140 Coriolis Flow Meter\u003c\/strong\u003e, consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequired minimum and maximum flow rate\u003c\/li\u003e\n\u003cli\u003eMedium type (liquid, gas, or mixture)\u003c\/li\u003e\n\u003cli\u003eRequired accuracy level\u003c\/li\u003e\n\u003cli\u003eProcess connection requirements\u003c\/li\u003e\n\u003cli\u003eHygienic requirements for food\/pharmaceutical applications\u003c\/li\u003e\n\u003cli\u003eNeed for density or concentration measurement\u003c\/li\u003e\n\u003cli\u003eCompact or advanced transmitter requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCorrect configuration ensures accurate measurement and stable operation in precision flow applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFAQ\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is Siemens SITRANS FC120\/FC140 used for?\u003c\/strong\u003e\u003cbr\u003eThe SITRANS FC120\/FC140 is designed for highly accurate measurement of low flow rates in liquids, gases, and mixtures. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the difference between FC120 and FC140?\u003c\/strong\u003e\u003cbr\u003eThe FC120 uses the FCT020 transmitter, while the FC140 uses the advanced FCT040 transmitter with additional measurement functions such as concentration calculation. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which industries use SITRANS FC120\/FC140?\u003c\/strong\u003e\u003cbr\u003eIt is widely used in pharmaceutical, chemical, food, laboratory, and industrial dosing applications requiring precise low-flow measurement.\u003c\/p\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":43421020192829,"sku":null,"price":4800.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/siemens-sitrans-fc120-fc140-coriolis-flow-meter.png?v=1785740446","url":"https:\/\/proinstru.com\/products\/siemens-sitrans-fc120-fc140-coriolis-flow-meter","provider":"Process Instrument","version":"1.0","type":"link"}