{"product_id":"rosemount-3051sam-scalable-ers-measurement-transmitter","title":"Rosemount 3051SAM Scalable ERS Measurement Transmitter","description":"\u003cp data-start=\"495\" data-end=\"933\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"499\" data-end=\"559\"\u003eRosemount™ 3051SAM Scalable ERS™ Measurement Transmitter\u003c\/strong\u003e is a key component of the Rosemount 3051S Electronic Remote Sensor (ERS™) System, designed for accurate differential pressure measurement in challenging level applications. It uses a digital architecture with two linked pressure sensors to calculate differential pressure electronically, eliminating traditional impulse piping systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"935\" data-end=\"1236\"\u003eWith flexible Coplanar™ and in-line sensor configurations, multiple process connection options, and compatibility with Rosemount 3051SAL transmitters, the 3051SAM provides a reliable solution for high-performance DP level measurement in tanks and process vessels. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1238\" data-end=\"1241\"\u003e\n\u003ch2 data-start=\"1243\" data-end=\"1258\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1260\" data-end=\"1870\"\u003e\n\u003cli data-start=\"1260\" data-end=\"1330\"\u003ePart of the Rosemount 3051S Electronic Remote Sensor (ERS™) System\u003c\/li\u003e\n\u003cli data-start=\"1331\" data-end=\"1400\"\u003eElectronic differential pressure measurement using linked sensors\u003c\/li\u003e\n\u003cli data-start=\"1401\" data-end=\"1472\"\u003eFaster response time compared with traditional impulse line systems\u003c\/li\u003e\n\u003cli data-start=\"1473\" data-end=\"1528\"\u003eAvailable in Coplanar™ and in-line sensor platforms\u003c\/li\u003e\n\u003cli data-start=\"1529\" data-end=\"1607\"\u003eSupports NPT, flange, manifold, and Rosemount 1199 remote seal connections\u003c\/li\u003e\n\u003cli data-start=\"1608\" data-end=\"1663\"\u003eSingle 2-wire 4–20 mA loop with HART® communication\u003c\/li\u003e\n\u003cli data-start=\"1664\" data-end=\"1724\"\u003eReduced maintenance with independent sensor installation\u003c\/li\u003e\n\u003cli data-start=\"1725\" data-end=\"1765\"\u003eSupports SIL 2\/3 safety applications\u003c\/li\u003e\n\u003cli data-start=\"1766\" data-end=\"1870\"\u003eHigh stability and reliable performance in demanding processes\u003cbr data-start=\"1830\" data-end=\"1833\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1872\" data-end=\"1875\"\u003e\n\u003ch2 data-start=\"1877\" data-end=\"1892\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"1894\" data-end=\"2167\"\u003e\n\u003cli data-start=\"1894\" data-end=\"1920\"\u003eTank level measurement\u003c\/li\u003e\n\u003cli data-start=\"1921\" data-end=\"1954\"\u003eHigh-pressure process vessels\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"1979\"\u003eDistillation columns\u003c\/li\u003e\n\u003cli data-start=\"1980\" data-end=\"2013\"\u003eChemical processing equipment\u003c\/li\u003e\n\u003cli data-start=\"2014\" data-end=\"2040\"\u003eOil \u0026amp; Gas applications\u003c\/li\u003e\n\u003cli data-start=\"2041\" data-end=\"2078\"\u003eRefinery and petrochemical plants\u003c\/li\u003e\n\u003cli data-start=\"2079\" data-end=\"2129\"\u003eSteam and high-temperature process measurement\u003c\/li\u003e\n\u003cli data-start=\"2130\" data-end=\"2167\"\u003eIndustrial DP measurement systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2169\" data-end=\"2172\"\u003e\n\u003ch2 data-start=\"2174\" data-end=\"2192\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"2194\" data-end=\"2284\"\u003eBefore selecting the \u003cstrong data-start=\"2215\" data-end=\"2273\"\u003eRosemount 3051SAM Scalable ERS Measurement Transmitter\u003c\/strong\u003e, consider:\u003c\/p\u003e\n\u003cul data-start=\"2286\" data-end=\"2613\"\u003e\n\u003cli data-start=\"2286\" data-end=\"2338\"\u003eRequired differential pressure measurement range\u003c\/li\u003e\n\u003cli data-start=\"2339\" data-end=\"2389\"\u003eTank height and level measurement requirements\u003c\/li\u003e\n\u003cli data-start=\"2390\" data-end=\"2437\"\u003eProcess temperature and pressure conditions\u003c\/li\u003e\n\u003cli data-start=\"2438\" data-end=\"2474\"\u003eRequired process connection type\u003c\/li\u003e\n\u003cli data-start=\"2475\" data-end=\"2557\"\u003eWhether a Rosemount 3051SAL secondary sensor is required for ERS configuration\u003c\/li\u003e\n\u003cli data-start=\"2558\" data-end=\"2613\"\u003eCommunication and safety certification requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2615\" data-end=\"2714\"\u003eCorrect ERS system configuration ensures stable measurement performance and simplified maintenance.\u003c\/p\u003e\n\u003chr data-start=\"2716\" data-end=\"2719\"\u003e\n\u003ch2 data-start=\"2721\" data-end=\"2727\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2729\" data-end=\"2960\"\u003e\u003cstrong data-start=\"2729\" data-end=\"2776\"\u003eQ1: What is the Rosemount 3051SAM used for?\u003c\/strong\u003e\u003cbr data-start=\"2776\" data-end=\"2779\"\u003eThe Rosemount 3051SAM is used as part of the ERS system for electronic differential pressure measurement, especially for DP level applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2962\" data-end=\"3216\"\u003e\u003cstrong data-start=\"2962\" data-end=\"3017\"\u003eQ2: How does the Rosemount 3051SAM ERS system work?\u003c\/strong\u003e\u003cbr data-start=\"3017\" data-end=\"3020\"\u003eThe system uses two pressure sensors connected by an electrical cable to calculate differential pressure digitally instead of using traditional impulse lines. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3218\" data-end=\"3446\"\u003e\u003cstrong data-start=\"3218\" data-end=\"3276\"\u003eQ3: What transmitters can work with Rosemount 3051SAM?\u003c\/strong\u003e\u003cbr data-start=\"3276\" data-end=\"3279\"\u003eThe ERS system can combine Rosemount 3051SAM and 3051SAL sensors to create a complete differential pressure measurement solution.\u003c\/p\u003e","brand":"Rosemount","offers":[{"title":"Default Title","offer_id":43395555131453,"sku":null,"price":400.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/rosemount-3051sam-scalable-ers-measurement-transmitter.png?v=1784880317","url":"https:\/\/proinstru.com\/products\/rosemount-3051sam-scalable-ers-measurement-transmitter","provider":"Process Instrument","version":"1.0","type":"link"}