{"product_id":"liquiline-cm42-liquid-analysis-transmitter","title":"Endress+Hauser Liquiline M CM42 Liquid Analysis Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"715\" data-end=\"751\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"753\" data-end=\"972\"\u003eThe \u003cstrong data-start=\"757\" data-end=\"804\"\u003eEndress+Hauser Liquiline M CM42 Transmitter\u003c\/strong\u003e is a high-performance industrial liquid analysis device designed for continuous measurement of \u003cstrong data-start=\"900\" data-end=\"947\"\u003epH, ORP, conductivity, and dissolved oxygen\u003c\/strong\u003e in process applications.\u003c\/p\u003e\n\u003cp data-start=\"974\" data-end=\"1354\"\u003eThe transmitter supports both \u003cstrong data-start=\"1004\" data-end=\"1032\"\u003eMemosens digital sensors\u003c\/strong\u003e and conventional analog sensors, enabling flexible integration into existing industrial systems. Designed for both hazardous and non-hazardous environments, CM42 provides stable signal processing and simplified operation for demanding industries including chemicals, pharmaceuticals, food processing, and water treatment.\u003c\/p\u003e\n\u003cp data-start=\"1356\" data-end=\"1506\"\u003eIts intuitive configuration and multiple communication protocols help improve process efficiency while reducing maintenance requirements and downtime.\u003c\/p\u003e\n\u003cp data-start=\"1508\" data-end=\"1728\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1539\" data-end=\"1570\"\u003eliquid analysis transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1572\" data-end=\"1590\"\u003epH transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1592\" data-end=\"1620\"\u003econductivity transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1622\" data-end=\"1653\"\u003eoxygen analyzer transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1655\" data-end=\"1689\"\u003eindustrial process transmitter\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1730\" data-end=\"1733\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1735\" data-end=\"1751\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1753\" data-end=\"2217\"\u003e• Supports pH, ORP, conductivity, and oxygen measurement\u003cbr data-start=\"1809\" data-end=\"1812\"\u003e• Compatible with Memosens and analog sensors\u003cbr data-start=\"1857\" data-end=\"1860\"\u003e• One-channel transmitter design\u003cbr data-start=\"1892\" data-end=\"1895\"\u003e• HART \/ PROFIBUS PA \/ FOUNDATION Fieldbus support\u003cbr data-start=\"1945\" data-end=\"1948\"\u003e• Suitable for hazardous and non-hazardous areas\u003cbr data-start=\"1996\" data-end=\"1999\"\u003e• IP66\/IP67 protection rating\u003cbr data-start=\"2028\" data-end=\"2031\"\u003e• Stainless steel or plastic housing options\u003cbr data-start=\"2075\" data-end=\"2078\"\u003e• Simplified operation and maintenance\u003cbr data-start=\"2116\" data-end=\"2119\"\u003e• Suitable for process industries and hygienic applications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2219\" data-end=\"2222\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"2224\" data-end=\"2250\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2252\" data-end=\"2502\"\u003e\n\u003cli data-section-id=\"s8kosx\" data-start=\"2252\" data-end=\"2280\"\u003eChemical process systems\u003c\/li\u003e\n\u003cli data-section-id=\"xtkpik\" data-start=\"2281\" data-end=\"2310\"\u003ePharmaceutical production\u003c\/li\u003e\n\u003cli data-section-id=\"1chdoi7\" data-start=\"2311\" data-end=\"2343\"\u003eFood and beverage processing\u003c\/li\u003e\n\u003cli data-section-id=\"hcl0oj\" data-start=\"2344\" data-end=\"2378\"\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"79zscl\" data-start=\"2379\" data-end=\"2406\"\u003ePower generation plants\u003c\/li\u003e\n\u003cli data-section-id=\"wsgffl\" data-start=\"2407\" data-end=\"2438\"\u003eOil and gas process systems\u003c\/li\u003e\n\u003cli data-section-id=\"199upxr\" data-start=\"2439\" data-end=\"2471\"\u003eIndustrial liquid monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"pdmsga\" data-start=\"2472\" data-end=\"2502\"\u003eProcess automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2504\" data-end=\"2507\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2509\" data-end=\"2542\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2544\" data-end=\"2587\"\u003eBefore selecting Liquiline M CM42, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2589\" data-end=\"2937\"\u003e\n\u003cli data-section-id=\"6nrgpw\" data-start=\"2589\" data-end=\"2658\"\u003eRequired measurement parameter (pH \/ ORP \/ conductivity \/ oxygen)\u003c\/li\u003e\n\u003cli data-section-id=\"16fno35\" data-start=\"2659\" data-end=\"2695\"\u003eSensor type (Memosens or analog)\u003c\/li\u003e\n\u003cli data-section-id=\"1clxqch\" data-start=\"2696\" data-end=\"2739\"\u003eCommunication protocol (HART \/ FF \/ PA)\u003c\/li\u003e\n\u003cli data-section-id=\"iopnlq\" data-start=\"2740\" data-end=\"2771\"\u003eHazardous area requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1cus2za\" data-start=\"2772\" data-end=\"2832\"\u003eHousing material preference (plastic or stainless steel)\u003c\/li\u003e\n\u003cli data-section-id=\"19m0bnj\" data-start=\"2833\" data-end=\"2882\"\u003eInstallation environment and protection level\u003c\/li\u003e\n\u003cli data-section-id=\"1j6u5c6\" data-start=\"2883\" data-end=\"2937\"\u003eOutput requirements (4–20mA \/ digital communication)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2939\" data-end=\"2942\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2944\" data-end=\"2958\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2960\" data-end=\"3143\"\u003e\u003cstrong data-start=\"2960\" data-end=\"3001\"\u003eQ: What is Liquiline M CM42 used for?\u003c\/strong\u003e\u003cbr data-start=\"3001\" data-end=\"3004\"\u003eA: It is used for industrial liquid analysis including pH, ORP, conductivity, and oxygen measurement. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3145\" data-end=\"3297\"\u003e\u003cstrong data-start=\"3145\" data-end=\"3187\"\u003eQ: Does CM42 support Memosens sensors?\u003c\/strong\u003e\u003cbr data-start=\"3187\" data-end=\"3190\"\u003eA: Yes. It supports both Memosens digital sensors and analog sensors. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3299\" data-end=\"3458\"\u003e\u003cstrong data-start=\"3299\" data-end=\"3340\"\u003eQ: Can it be used in hazardous areas?\u003c\/strong\u003e\u003cbr data-start=\"3340\" data-end=\"3343\"\u003eA: Yes. It includes multiple hazardous area approvals such as ATEX and IECEx. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3460\" data-end=\"3612\"\u003e\u003cstrong data-start=\"3460\" data-end=\"3511\"\u003eQ: Which communication protocols are available?\u003c\/strong\u003e\u003cbr data-start=\"3511\" data-end=\"3514\"\u003eA: HART, PROFIBUS PA, and FOUNDATION Fieldbus are supported. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3614\" data-end=\"3777\"\u003e\u003cstrong data-start=\"3614\" data-end=\"3677\"\u003eQ: Is it suitable for food and pharmaceutical applications?\u003c\/strong\u003e\u003cbr data-start=\"3677\" data-end=\"3680\"\u003eA: Yes. It is widely used in hygienic process environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3779\" data-end=\"3917\"\u003e\u003cstrong data-start=\"3779\" data-end=\"3826\"\u003eQ: What protection level does CM42 provide?\u003c\/strong\u003e\u003cbr data-start=\"3826\" data-end=\"3829\"\u003eA: IP66\/IP67 and NEMA 4X protection are available. \u003cspan class=\"\" data-state=\"delayed-open\" aria-describedby=\"radix-_r_ap_\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325678026813,"sku":null,"price":1450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/liquiline-cm42-liquid-analysis-transmitter-product-view.png?v=1783304252","url":"https:\/\/proinstru.com\/products\/liquiline-cm42-liquid-analysis-transmitter","provider":"Process Instrument","version":"1.0","type":"link"}