{"product_id":"endress-hauser-soliwave-fdr56-microwave-barrier-transceiver","title":"Endress+Hauser Soliwave FDR56 Microwave Barrier Transceiver","description":"\u003cp\u003eThe Soliwave FDR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FQR56 emitter.\u003c\/p\u003e\n\u003ch2\u003eMicrowave barrier transceiver Soliwave FDR56\u003c\/h2\u003e\n\u003cp\u003eTransceiver for non-contact point level detection in bulk solids\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eProcess temperature\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eNon-contact installation: any\u003cbr\u003eWithin installation:\u003cbr\u003e-40°C...+70°C (-40°F...+158°F)\u003cbr\u003eWith high temperature adapter:\u003cbr\u003eup to +450°C (+842°F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eProcess pressure \/ max. overpressure limit\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eNon-contact installation: any\u003cbr\u003eWithin installation:\u003cbr\u003e0.5 bar ... 6.8 bar (7.2 psi ... 99 psi) abs.\u003cbr\u003eWith high pressure adapter:\u003cbr\u003eup to +21 bar (+305 psi) abs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMin. density of medium\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eSolid weight: \u0026gt; 10 g\/l\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe Soliwave FDR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FQR56 emitter.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eTypical bulk solids are: Wood chips, wood dust or flour; plaster, cement, ash; paper or cardboard shred, gravel, sand, dried powders in general, bags and boxes.\u003c\/p\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eProcess connections: Threads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eAmbient temperature: -40 to +70°C (-40 to +158°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMeasuring range: Max. 100m (328ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eInternational explosion protection certificates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHighly reliable measurement due to flush-mounted installation and possible non-contact installation as well as indication of the signal strength on the transceiver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMechanical robust solution ensures cost savings over the whole life cycle of the product: No wear and tear, process-wetted ceramic sensor diaphragm (optional), long serviceable life, maintenance free\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eElectronics housing can be rotated by 360°, allowing adjustment into optimum position after installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDirect connection of the supply voltage (emitter and receiver separately or together)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMechanically compatible to FQR50\/FDR50 microwave barrier, existing process connections can continue to be used; likewise, accessories such as adapter flanges, installation brackets and sight glasses can continue to be used\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43351255089213,"sku":null,"price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-soliwave-fdr56-microwave-barrier-transceiver.png?v=1784172762","url":"https:\/\/proinstru.com\/products\/endress-hauser-soliwave-fdr56-microwave-barrier-transceiver","provider":"Process Instrument","version":"1.0","type":"link"}