{"product_id":"endress-hauser-proline-prowirl-f-200-flowmeter-7f2c50","title":"Endress+Hauser Proline Prowirl F 200 Flowmeter 7F2C50-","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"725\" data-start=\"689\" data-section-id=\"1vevt5w\"\u003eProduct Description\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-end=\"899\" data-start=\"727\"\u003eThe \u003cstrong data-end=\"797\" data-start=\"731\"\u003eEndress+Hauser Proline Prowirl F 200 (7F2C50) Vortex Flowmeter\u003c\/strong\u003e is designed for reliable measurement of steam, gases, and liquids in industrial process applications.\u003c\/p\u003e\n\u003cp data-end=\"1203\" data-start=\"901\"\u003eUsing vortex shedding technology, the flowmeter delivers stable and accurate flow measurement while minimizing maintenance requirements due to its no-moving-parts design. The integrated temperature measurement capability allows additional energy monitoring functions, especially for steam applications.\u003c\/p\u003e\n\u003cp data-end=\"1423\" data-start=\"1205\"\u003eProwirl F 200 is widely used in utility systems, process industries, and energy monitoring applications where continuous and dependable \u003cstrong data-end=\"1372\" data-start=\"1341\"\u003eindustrial flow measurement\u003c\/strong\u003e is required. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1589\" data-start=\"1425\"\u003eNatural SEO keywords included: \u003cstrong data-end=\"1476\" data-start=\"1456\"\u003evortex flowmeter\u003c\/strong\u003e, \u003cstrong data-end=\"1498\" data-start=\"1478\"\u003esteam flow meter\u003c\/strong\u003e, \u003cstrong data-end=\"1524\" data-start=\"1500\"\u003egas flow measurement\u003c\/strong\u003e, \u003cstrong data-end=\"1557\" data-start=\"1526\"\u003eindustrial flow transmitter\u003c\/strong\u003e, \u003cstrong data-end=\"1589\" data-start=\"1559\"\u003eEndress+Hauser flow sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-end=\"1594\" data-start=\"1591\"\u003e\n\u003ch1 data-end=\"1612\" data-start=\"1596\" data-section-id=\"1vrrhye\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-end=\"1960\" data-start=\"1614\"\u003e• Vortex flow measurement technology\u003cbr data-end=\"1653\" data-start=\"1650\"\u003e• Suitable for steam, gas and liquid applications\u003cbr data-end=\"1705\" data-start=\"1702\"\u003e• Integrated temperature measurement capability\u003cbr data-end=\"1755\" data-start=\"1752\"\u003e• Maintenance-free design with no moving parts\u003cbr data-end=\"1804\" data-start=\"1801\"\u003e• High measurement stability\u003cbr data-end=\"1835\" data-start=\"1832\"\u003e• Heartbeat Technology diagnostics\u003cbr data-end=\"1872\" data-start=\"1869\"\u003e• Multiple communication options available\u003cbr data-end=\"1917\" data-start=\"1914\"\u003e• Suitable for industrial utility systems\u003c\/p\u003e\n\u003chr data-end=\"1965\" data-start=\"1962\"\u003e\n\u003ch1 data-end=\"1993\" data-start=\"1967\" data-section-id=\"l5ozhv\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-end=\"2257\" data-start=\"1995\"\u003e\n\u003cli data-end=\"2029\" data-start=\"1995\" data-section-id=\"a5j4o8\"\u003eSteam flow measurement systems\u003c\/li\u003e\n\u003cli data-end=\"2063\" data-start=\"2030\" data-section-id=\"1wzi2tf\"\u003eIndustrial utility monitoring\u003c\/li\u003e\n\u003cli data-end=\"2090\" data-start=\"2064\" data-section-id=\"l7hwrn\"\u003eCompressed air systems\u003c\/li\u003e\n\u003cli data-end=\"2121\" data-start=\"2091\" data-section-id=\"m04w6y\"\u003eGas distribution processes\u003c\/li\u003e\n\u003cli data-end=\"2155\" data-start=\"2122\" data-section-id=\"f3t2kj\"\u003eEnergy consumption monitoring\u003c\/li\u003e\n\u003cli data-end=\"2186\" data-start=\"2156\" data-section-id=\"6gyw6r\"\u003eChemical processing plants\u003c\/li\u003e\n\u003cli data-end=\"2218\" data-start=\"2187\" data-section-id=\"1jhjfua\"\u003ePower generation facilities\u003c\/li\u003e\n\u003cli data-end=\"2257\" data-start=\"2219\" data-section-id=\"xh4ves\"\u003eGeneral industrial process systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2262\" data-start=\"2259\"\u003e\n\u003ch1 data-end=\"2297\" data-start=\"2264\" data-section-id=\"6p5k8g\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-end=\"2339\" data-start=\"2299\"\u003eBefore selecting Prowirl F 200, confirm:\u003c\/p\u003e\n\u003cul data-end=\"2657\" data-start=\"2341\"\u003e\n\u003cli data-end=\"2380\" data-start=\"2341\" data-section-id=\"285una\"\u003eMedium type (steam, gas, or liquid)\u003c\/li\u003e\n\u003cli data-end=\"2426\" data-start=\"2381\" data-section-id=\"11i5so8\"\u003ePipe size requirements (DN compatibility)\u003c\/li\u003e\n\u003cli data-end=\"2458\" data-start=\"2427\" data-section-id=\"vo2y1y\"\u003eProcess pressure conditions\u003c\/li\u003e\n\u003cli data-end=\"2488\" data-start=\"2459\" data-section-id=\"1a1xn0w\"\u003eProcess temperature range\u003c\/li\u003e\n\u003cli data-end=\"2553\" data-start=\"2489\" data-section-id=\"1sbu2xl\"\u003eRequired communication protocol (HART \/ Fieldbus \/ PROFIBUS)\u003c\/li\u003e\n\u003cli data-end=\"2599\" data-start=\"2554\" data-section-id=\"1bhcjt8\"\u003eInstallation type and flange requirements\u003c\/li\u003e\n\u003cli data-end=\"2657\" data-start=\"2600\" data-section-id=\"1ift3fa\"\u003eEnergy monitoring requirements for steam applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2662\" data-start=\"2659\"\u003e\n\u003ch1 data-end=\"2678\" data-start=\"2664\" data-section-id=\"a0z7dm\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-end=\"2872\" data-start=\"2680\"\u003e\u003cstrong data-end=\"2733\" data-start=\"2680\"\u003eQ: What is Endress+Hauser Prowirl F 200 used for?\u003c\/strong\u003e\u003cbr data-end=\"2736\" data-start=\"2733\"\u003eA: It is used for vortex flow measurement of steam, gases, and liquids in industrial applications. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3030\" data-start=\"2874\"\u003e\u003cstrong data-end=\"2913\" data-start=\"2874\"\u003eQ: Can Prowirl F 200 measure steam?\u003c\/strong\u003e\u003cbr data-end=\"2916\" data-start=\"2913\"\u003eA: Yes. It is commonly used for saturated and superheated steam measurement. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3139\" data-start=\"3032\"\u003e\u003cstrong data-end=\"3067\" data-start=\"3032\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-end=\"3070\" data-start=\"3067\"\u003eA: No. Its no-moving-parts design minimizes maintenance requirements.\u003c\/p\u003e\n\u003cp data-end=\"3316\" data-start=\"3141\"\u003e\u003cstrong data-end=\"3189\" data-start=\"3141\"\u003eQ: What communication options are available?\u003c\/strong\u003e\u003cbr data-end=\"3192\" data-start=\"3189\"\u003eA: Depending on configuration, it supports HART, PROFIBUS PA, and FOUNDATION Fieldbus. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3500\" data-start=\"3318\"\u003e\u003cstrong data-end=\"3340\" data-start=\"3318\"\u003eQ: What is 7F2C50?\u003c\/strong\u003e\u003cbr data-end=\"3343\" data-start=\"3340\"\u003eA: 7F2C50 is a configuration\/order code within the Prowirl F 200 product family rather than a standalone product model. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3638\" data-start=\"3502\"\u003e\u003cstrong data-end=\"3554\" data-start=\"3502\"\u003eQ: Is it suitable for energy monitoring systems?\u003c\/strong\u003e\u003cbr data-end=\"3557\" data-start=\"3554\"\u003eA: Yes. It is commonly used for steam and utility energy management applications.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43312170074173,"sku":null,"price":3420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/prowirl-f200-7f2c50-product-view.png?v=1782892406","url":"https:\/\/proinstru.com\/products\/endress-hauser-proline-prowirl-f-200-flowmeter-7f2c50","provider":"Process Instrument","version":"1.0","type":"link"}