{"product_id":"endress-hauser-memosens-cfs51-pah-sensor","title":"Endress+Hauser Memosens CFS51 PAH Sensor","description":"\u003cp\u003eThe rugged and low-maintenance Memosens CFS51 fluorescence sensor measures polycyclic aromatic hydrocarbons (PAHs) in accordance with MEPC.259(68) and MEPC.340(77). Thanks to the practical solid-state reference, you can readjust and calibrate the sensor onboard the vessel - supported by user-friendly guidance in the transmitter menu. This makes the calibration procedure simple and error-free, and you benefit from an exceptionally long factory maintenance interval of 4 years.\u003c\/p\u003e\n\u003ch2\u003ePAH sensor Memosens CFS51\u003c\/h2\u003e\n\u003cp\u003eMemosens sensor for measuring the concentration of polycyclic aromatic hydrocarbons in discharge water of marine exhaust gas cleaning systems (EGCS)\u003c\/p\u003e\n\u003cp\u003eThe Memosens CFS51 fluorescence sensor accurately measures the PAH concentration in the inlet and outlet of marine gas scrubbers (ECGS) offering all benefits of the Memosens digital sensor technology.\u003c\/p\u003e\n\u003cp\u003eThe solid-state reference allows the ship's crew to calibrate and adjust the sensor directly on board, which helps extend the sensor's factory service interval to 4 years.\u003c\/p\u003e\n\u003cp\u003eThe sophisticated design of the assembly, as well as the angled installation position in which the assembly holds the sensor, prevents air bubbles from influencing the measured value.\u003c\/p\u003e\n\u003cp\u003eFor Exhaust Gas Cleaning Systems (ECGS), there is an all-in-one solution that incorporates the Memosens CFS51 PAH sensor, a pH sensor and a turbidity sensor.\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMeasuring range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e0.000 to 5000 PAHphe\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eProcess temperature\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e-5 to 55 °C (20 to 130 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eProcess pressure\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e10 bar abs. (just the sensor)\u003cbr\u003e6 bar abs. (combination sensor and assembly)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe rugged and low-maintenance Memosens CFS51 fluorescence sensor measures polycyclic aromatic hydrocarbons (PAHs) in accordance with MEPC.259(68) and MEPC.340(77). Thanks to the practical solid-state reference, you can readjust and calibrate the sensor onboard the vessel - supported by user-friendly guidance in the transmitter menu. This makes the calibration procedure simple and error-free, and you benefit from an exceptionally long factory maintenance interval of 4 years.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMemosens CFS51 measures PAHs with high accuracy in both the inlet and outlet of marine exhaust gas cleaning systems (scrubbers) and is suitable for all discharge water flow rates.\u003c\/p\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe sensor is certified by the following approval bodies:\u003c\/p\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDNV (Det Norske Veritas)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eLR (Lloyd’s Register)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eBV (Bureau Veritas)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eABS (American Bureau of Shipping)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"eh-generic--text\"\u003eFor washwater monitoring in EGCS, the PAH sensor is also available as an \u003ca class=\"eh-link eh-link--03\" title=\"Wash water monitoring for ship exhaust gas scrubbers\" href=\"https:\/\/www.endress.com\/en\/industry-expertise\/process-solutions\/wash-water-monitoring-marine\" data-cs-tracking-ps-name=\"PS.RichText\" data-cs-tracking-target-id=\"10514293\"\u003eapproved all-in-one solution\u003c\/a\u003e including pH and turbidity measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe uniquely long factory maintenance interval saves you a lot of costs and organizational effort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe optionally available flow assembly holds the sensor at the ideal installation angle to minimize disturbing influences caused by air bubbles. In addition, it can be tilted for quick mounting and dismounting of the sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDNV approved integrated turbidity correction in the range of 0-50 FNU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHigh material compliance of sensor and flow assembly according to IACS E10 (flame retardancy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe solid-state reference makes calibration very easy for the end user - and you can completely eliminate the need for toxic phenantrene, which increases safety for your employees and the environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe suitability of the solid-state reference for calibration and readjustment of the PAH sensor on board was confirmed by DNV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338568073277,"sku":null,"price":1000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-memosens-cfs51-pah-sensor.webp?v=1783928347","url":"https:\/\/proinstru.com\/products\/endress-hauser-memosens-cfs51-pah-sensor","provider":"Process Instrument","version":"1.0","type":"link"}