{"product_id":"endress-hauser-itherm-flameline-taf12d-thermometer","title":"Endress+Hauser iTHERM FlameLine TAF12D Thermometer","description":"\u003cp\u003eMeasuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.\u003c\/p\u003e\n\u003ch2\u003eiTHERM FlameLine TAF12D High temperature thermometer\u003c\/h2\u003e\n\u003cp\u003eMetric TC thermometer with dual ceramic thermowell for high-temperature applications\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eclass 2 acc. to IEC 60584\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eat 20 °C: 1 bar (15 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eType S:\u003cbr\u003e0 °C ...1.600 °C\u003cbr\u003e(32 °F ...2.912 °F)\u003cbr\u003eType R:\u003cbr\u003e0 °C ...1.600 °C\u003cbr\u003e(32 °F ...2.912 °F)\u003cbr\u003eType B:\u003cbr\u003e600 °C ...1.700 °C\u003cbr\u003e(1.112 °F ...3.092 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eup to 3.500,00 mm (137,80'')\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eMeasuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\" data-cs-pcueid=\"JVcAPU\"\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eProcess temperatures: up to +1700 °C (+3092 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"8ozaIq\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eLong lifetime by usage of innovative thermowell materials with increased wear and chemical resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"R57x5p\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eLong term stable measurement due to sensor protection with non-porous materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"zCVLYX\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFlexible product selection by modular design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"KZcpeh\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eOptimized life cycle costs by means of replaceable spare parts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338584719421,"sku":null,"price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-itherm-flameline-taf12d-high-temperature-thermometer.webp?v=1783929030","url":"https:\/\/proinstru.com\/products\/endress-hauser-itherm-flameline-taf12d-thermometer","provider":"Process Instrument","version":"1.0","type":"link"}