{"product_id":"endress-hauser-deltapilot-fmb70-hydrostatic-level-transmitter","title":"Endress+Hauser Deltapilot FMB70 Hydrostatic Level Transmitter","description":"\u003cp\u003eThe Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM\/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.\u003c\/p\u003e\n\u003ch2\u003eHydrostatic Level measurement Deltapilot FMB70\u003c\/h2\u003e\n\u003cp\u003eHighest performance pressure sensor with the Contite cell for hydrostatic level measurement\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eStandard 0.1%\u003cbr\u003eOptional 0.075%\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eProcess temperature\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e-10°C...+100°C\u003cbr\u003e(+14°F...+212°F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003ePressure measuring range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e100 mbar...10 bar\u003cbr\u003e(1.5 psi...150 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eProcess pressure \/ max. overpressure limit\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e40 bar (600 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMain wetted parts\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eAlloy C\u003cbr\u003e316L\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. measurement distance\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e100 m (328 ft) H2O\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMaterial process membrane\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e316L, AlloyC,\u003cbr\u003eGold-Rhodium\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMeasuring cell\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e100 mbar...10 bar\u003cbr\u003e(1.5 psi...150 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM\/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFor level and\/or pressure measurement.\u003c\/p\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eProcess connections: Threads, flanges and hygienic connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eTemperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMeasuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eAccuracy: ±0.075%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eInternational explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eBest batch-to-batch repeatability and long-term stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eModular concept for easy replacement of display or electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHistoROM\/M-DAT data backup for instrument settings and measured values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFunction-monitored from the measuring cell to the electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eSeamless and independent system integration (HART\/PA\/FF)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eInternational usage thanks to a wide range of approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43351676977213,"sku":null,"price":1300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-deltapilot-fmb70-hydrostatic-level-transmitter.png?v=1784189010","url":"https:\/\/proinstru.com\/products\/endress-hauser-deltapilot-fmb70-hydrostatic-level-transmitter","provider":"Process Instrument","version":"1.0","type":"link"}