{"product_id":"e-h-w-400-proline-promag-w-400-5w4c-electromagnetic-flowmeter","title":"Endress+Hauser  W 400 Proline Promag W 400 5W4C electromagnetic flowmeter","description":"\u003cp data-start=\"327\" data-end=\"644\"\u003eThe \u003cstrong data-start=\"331\" data-end=\"388\"\u003eProline Promag W 400 (5W4C) Electromagnetic Flowmeter\u003c\/strong\u003e is designed for reliable \u003cstrong data-start=\"414\" data-end=\"471\"\u003eflow measurement in water and wastewater applications\u003c\/strong\u003e, including installations in \u003cstrong data-start=\"500\" data-end=\"540\"\u003eharsh or hard-to-access environments\u003c\/strong\u003e. It uses \u003cstrong data-start=\"550\" data-end=\"592\"\u003eelectromagnetic measurement technology\u003c\/strong\u003e, ensuring stable performance without pressure loss.\u003c\/p\u003e\n\u003cp data-start=\"646\" data-end=\"934\"\u003eThis model features a \u003cstrong data-start=\"668\" data-end=\"712\"\u003eremote transmitter with cable connection\u003c\/strong\u003e, allowing flexible installation and safe operation in flooded or vibration-prone areas. In addition, it offers \u003cstrong data-start=\"824\" data-end=\"873\"\u003eadvanced diagnostics and robust communication\u003c\/strong\u003e, making it ideal for municipal and industrial water systems.\u003c\/p\u003e\n\u003cp data-start=\"936\" data-end=\"1058\"\u003eNot Recommended For:\u003cbr data-start=\"956\" data-end=\"959\"\u003e• Non-conductive liquids (e.g., oils, gases)\u003cbr data-start=\"1003\" data-end=\"1006\"\u003e• Applications requiring battery-powered operation\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/instrugauge.com\/wp-content\/uploads\/TI01046DEN_1021.pdf\"\u003eProline Promag W 400 Technical Information (TI)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1106\" data-end=\"1124\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1126\" data-end=\"1261\"\u003e• \u003cstrong data-start=\"1128\" data-end=\"1153\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-start=\"1160\" data-end=\"1196\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e, suitable for conductive liquids such as water and wastewater.\u003c\/p\u003e\n\u003cp data-start=\"1263\" data-end=\"1388\"\u003e• \u003cstrong data-start=\"1265\" data-end=\"1286\"\u003eInstallation Type\u003c\/strong\u003e: Features a \u003cstrong data-start=\"1299\" data-end=\"1351\"\u003eremote-mounted transmitter with cable connection\u003c\/strong\u003e, ideal for difficult environments.\u003c\/p\u003e\n\u003cp data-start=\"1390\" data-end=\"1498\"\u003e• \u003cstrong data-start=\"1392\" data-end=\"1412\"\u003eApplication Type\u003c\/strong\u003e: Designed for \u003cstrong data-start=\"1427\" data-end=\"1495\"\u003ewater supply, wastewater treatment, and industrial water systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1500\" data-end=\"1620\"\u003e• \u003cstrong data-start=\"1502\" data-end=\"1524\"\u003eProcess Conditions\u003c\/strong\u003e: Verify \u003cstrong data-start=\"1533\" data-end=\"1593\"\u003etemperature, pressure, and lining material compatibility\u003c\/strong\u003e for optimal performance.\u003c\/p\u003e\n\u003cp data-start=\"1622\" data-end=\"1725\"\u003e• \u003cstrong data-start=\"1624\" data-end=\"1652\"\u003eOutput and Communication\u003c\/strong\u003e: Supports \u003cstrong data-start=\"1663\" data-end=\"1722\"\u003e4–20 mA, pulse, HART, and digital communication options\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1khpjep\" data-start=\"1771\" data-end=\"1809\"\u003eWhy Choose the Proline Promag W 400\u003c\/h2\u003e\n\u003cp data-start=\"1811\" data-end=\"1980\"\u003e• \u003cstrong data-start=\"1813\" data-end=\"1853\"\u003eAccurate Electromagnetic Measurement\u003c\/strong\u003e\u003cbr data-start=\"1853\" data-end=\"1856\"\u003eBased on \u003cstrong data-start=\"1865\" data-end=\"1882\"\u003eFaraday’s law\u003c\/strong\u003e, it provides precise flow measurement independent of pressure, temperature, or density changes.\u003c\/p\u003e\n\u003cp data-start=\"1982\" data-end=\"2173\"\u003e• \u003cstrong data-start=\"1984\" data-end=\"2028\"\u003eRemote Transmitter with Cable Connection\u003c\/strong\u003e\u003cbr data-start=\"2028\" data-end=\"2031\"\u003eThe transmitter can be installed away from the sensor. Therefore, it improves accessibility and safety in \u003cstrong data-start=\"2137\" data-end=\"2170\"\u003eharsh or flooded environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2175\" data-end=\"2320\"\u003e• \u003cstrong data-start=\"2177\" data-end=\"2197\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-start=\"2197\" data-end=\"2200\"\u003eThe full-bore design ensures \u003cstrong data-start=\"2229\" data-end=\"2247\"\u003eno obstruction\u003c\/strong\u003e, so it does not create pressure drop. This improves system efficiency.\u003c\/p\u003e\n\u003cp data-start=\"2322\" data-end=\"2482\"\u003e• \u003cstrong data-start=\"2324\" data-end=\"2363\"\u003eAdvanced Diagnostics and Monitoring\u003c\/strong\u003e\u003cbr data-start=\"2363\" data-end=\"2366\"\u003eIntegrated diagnostics help detect issues early. In addition, they improve system reliability and reduce downtime.\u003c\/p\u003e\n\u003cp data-start=\"2484\" data-end=\"2636\"\u003e• \u003cstrong data-start=\"2486\" data-end=\"2518\"\u003eOptimized for Water Industry\u003c\/strong\u003e\u003cbr data-start=\"2518\" data-end=\"2521\"\u003eIt is specifically designed for \u003cstrong data-start=\"2553\" data-end=\"2600\"\u003emunicipal water and wastewater applications\u003c\/strong\u003e, including pipelines with solids.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2696\" data-end=\"2702\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2704\" data-end=\"2865\"\u003e\u003cstrong data-start=\"2704\" data-end=\"2753\"\u003eQ: What is the advantage of the Promag W 400?\u003c\/strong\u003e\u003cbr data-start=\"2753\" data-end=\"2756\"\u003eA: Its \u003cstrong data-start=\"2763\" data-end=\"2807\"\u003eremote transmitter with cable connection\u003c\/strong\u003e allows flexible installation in difficult environments.\u003c\/p\u003e\n\u003cp data-start=\"2867\" data-end=\"3016\"\u003e\u003cstrong data-start=\"2867\" data-end=\"2906\"\u003eQ: Can it be used in flooded areas?\u003c\/strong\u003e\u003cbr data-start=\"2906\" data-end=\"2909\"\u003eA: Yes. The remote design allows the transmitter to be installed in a safe location away from the sensor.\u003c\/p\u003e\n\u003cp data-start=\"3018\" data-end=\"3141\"\u003e\u003cstrong data-start=\"3018\" data-end=\"3056\"\u003eQ: Does it require external power?\u003c\/strong\u003e\u003cbr data-start=\"3056\" data-end=\"3059\"\u003eA: Yes. It operates with a \u003cstrong data-start=\"3086\" data-end=\"3111\"\u003estandard power supply\u003c\/strong\u003e for continuous measurement.\u003c\/p\u003e\n\u003cp data-start=\"3143\" data-end=\"3268\"\u003e\u003cstrong data-start=\"3143\" data-end=\"3178\"\u003eQ: Does it cause pressure loss?\u003c\/strong\u003e\u003cbr data-start=\"3178\" data-end=\"3181\"\u003eA: No. The electromagnetic principle ensures \u003cstrong data-start=\"3226\" data-end=\"3265\"\u003eno obstruction and no pressure drop\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338545758269,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-w400-5w4c-electromagnetic-flowmeter..png?v=1783926827","url":"https:\/\/proinstru.com\/products\/e-h-w-400-proline-promag-w-400-5w4c-electromagnetic-flowmeter","provider":"Process Instrument","version":"1.0","type":"link"}