{"product_id":"e-h-proline-promag-p-100-5e1b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag P 100 5E1B electromagnetic flowmeter","description":"\u003cp data-start=\"349\" data-end=\"611\"\u003eThe \u003cstrong data-start=\"353\" data-end=\"399\"\u003eEndress+Hauser Proline Promag E 100 (5E1B)\u003c\/strong\u003e is a reliable electromagnetic flowmeter designed for \u003cstrong data-start=\"453\" data-end=\"507\"\u003estandard applications involving conductive liquids\u003c\/strong\u003e. It provides stable and accurate flow measurement while maintaining a compact and lightweight design.\u003c\/p\u003e\n\u003cp data-start=\"613\" data-end=\"840\"\u003eThis device is ideal for basic process monitoring where cost efficiency and dependable performance are essential. In addition, it supports seamless integration into automation systems through digital communication interfaces.\u003c\/p\u003e\n\u003cp data-start=\"842\" data-end=\"939\"\u003eTypical applications include water treatment, utility systems and general industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"941\" data-end=\"1066\"\u003eNot Recommended For:\u003cbr data-start=\"961\" data-end=\"964\"\u003e• Non-conductive liquids such as oil or gas\u003cbr data-start=\"1007\" data-end=\"1010\"\u003e• Highly corrosive or extreme temperature environments\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1101\" data-end=\"1120\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1122\" data-end=\"1564\"\u003e• Confirm that the \u003cstrong data-start=\"1141\" data-end=\"1178\"\u003emedium is electrically conductive\u003c\/strong\u003e, which is required for electromagnetic measurement\u003cbr data-start=\"1229\" data-end=\"1232\"\u003e• Verify the \u003cstrong data-start=\"1245\" data-end=\"1259\"\u003eflow range\u003c\/strong\u003e, depending on pipe size and process conditions\u003cbr data-start=\"1306\" data-end=\"1309\"\u003e• Choose appropriate \u003cstrong data-start=\"1330\" data-end=\"1348\"\u003eliner material\u003c\/strong\u003e, typically PTFE, based on chemical compatibility\u003cbr data-start=\"1397\" data-end=\"1400\"\u003e• Check the \u003cstrong data-start=\"1412\" data-end=\"1435\"\u003eprocess temperature\u003c\/strong\u003e, usually up to around \u003cstrong data-start=\"1458\" data-end=\"1469\"\u003e+130 °C\u003c\/strong\u003e\u003cbr data-start=\"1469\" data-end=\"1472\"\u003e• In addition, ensure the \u003cstrong data-start=\"1498\" data-end=\"1531\"\u003epressure rating and pipe size\u003c\/strong\u003e match your system requirements\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tntlsm\" data-start=\"1599\" data-end=\"1630\"\u003eWhy Choose the Promag E 100\u003c\/h3\u003e\n\u003cp data-start=\"1632\" data-end=\"1805\"\u003e• \u003cstrong data-start=\"1634\" data-end=\"1670\"\u003eReliable Measurement Performance\u003c\/strong\u003e\u003cbr data-start=\"1670\" data-end=\"1673\"\u003eThe device delivers stable and repeatable readings for conductive liquids. Therefore, it is suitable for daily process monitoring.\u003c\/p\u003e\n\u003cp data-start=\"1807\" data-end=\"1968\"\u003e• \u003cstrong data-start=\"1809\" data-end=\"1844\"\u003eCompact and Space-Saving Design\u003c\/strong\u003e\u003cbr data-start=\"1844\" data-end=\"1847\"\u003eIts lightweight construction allows installation in confined spaces. As a result, it fits easily into existing systems.\u003c\/p\u003e\n\u003cp data-start=\"1970\" data-end=\"2116\"\u003e• \u003cstrong data-start=\"1972\" data-end=\"1999\"\u003eCost-Effective Solution\u003c\/strong\u003e\u003cbr data-start=\"1999\" data-end=\"2002\"\u003eThis model focuses on essential functions. Consequently, it offers a good balance between performance and price.\u003c\/p\u003e\n\u003cp data-start=\"2118\" data-end=\"2264\"\u003e• \u003cstrong data-start=\"2120\" data-end=\"2150\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"2150\" data-end=\"2153\"\u003eThere are no moving parts inside the sensor. This design reduces wear and minimizes maintenance requirements.\u003c\/p\u003e\n\u003cp data-start=\"2266\" data-end=\"2427\"\u003e• \u003cstrong data-start=\"2268\" data-end=\"2306\"\u003eFlexible Communication Integration\u003c\/strong\u003e\u003cbr data-start=\"2306\" data-end=\"2309\"\u003eIt supports outputs such as \u003cstrong data-start=\"2337\" data-end=\"2364\"\u003e4–20 mA, HART or Modbus\u003c\/strong\u003e. In addition, integration with PLC or DCS systems is simple.\u003c\/p\u003e\n\u003cp data-start=\"2429\" data-end=\"2639\"\u003e• \u003cstrong data-start=\"2431\" data-end=\"2487\"\u003eStable Measurement Independent of Process Conditions\u003c\/strong\u003e\u003cbr data-start=\"2487\" data-end=\"2490\"\u003eThe electromagnetic principle is unaffected by density, pressure or viscosity. Therefore, measurement remains consistent under changing conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"2677\" data-end=\"2684\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"2686\" data-end=\"2820\"\u003e\u003cstrong data-start=\"2686\" data-end=\"2729\"\u003eQ: What media can Promag E 100 measure?\u003c\/strong\u003e\u003cbr data-start=\"2729\" data-end=\"2732\"\u003eA: It measures \u003cstrong data-start=\"2747\" data-end=\"2769\"\u003econductive liquids\u003c\/strong\u003e, including water, wastewater and process fluids.\u003c\/p\u003e\n\u003cp data-start=\"2822\" data-end=\"2961\"\u003e\u003cstrong data-start=\"2822\" data-end=\"2861\"\u003eQ: What is the measuring principle?\u003c\/strong\u003e\u003cbr data-start=\"2861\" data-end=\"2864\"\u003eA: It uses \u003cstrong data-start=\"2875\" data-end=\"2920\"\u003eelectromagnetic induction (Faraday’s law)\u003c\/strong\u003e to determine flow velocity and volume.\u003c\/p\u003e\n\u003cp data-start=\"2963\" data-end=\"3096\"\u003e\u003cstrong data-start=\"2963\" data-end=\"2997\"\u003eQ: What outputs are available?\u003c\/strong\u003e\u003cbr data-start=\"2997\" data-end=\"3000\"\u003eA: The device supports \u003cstrong data-start=\"3023\" data-end=\"3065\"\u003e4–20 mA, HART and Modbus communication\u003c\/strong\u003e, depending on configuration.\u003c\/p\u003e\n\u003cp data-start=\"3098\" data-end=\"3220\"\u003e\u003cstrong data-start=\"3098\" data-end=\"3141\"\u003eQ: Does it require regular maintenance?\u003c\/strong\u003e\u003cbr data-start=\"3141\" data-end=\"3144\"\u003eA: No. Because it has \u003cstrong data-start=\"3166\" data-end=\"3185\"\u003eno moving parts\u003c\/strong\u003e, maintenance needs are very low.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327890063421,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-e100-5e1b-electromagnetic-flowmeter.webp?v=1783412195","url":"https:\/\/proinstru.com\/products\/e-h-proline-promag-p-100-5e1b-electromagnetic-flowmeter","provider":"Process Instrument","version":"1.0","type":"link"}