{"product_id":"e-h-proline-promag-h-500-5h5b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag H 500 5H5B electromagnetic flowmeter","description":"\u003cp data-start=\"189\" data-end=\"511\"\u003eThe \u003cstrong data-start=\"193\" data-end=\"263\"\u003eEndress+Hauser Proline Promag H 500 5H5B Electromagnetic Flowmeter\u003c\/strong\u003e is a \u003cstrong data-start=\"269\" data-end=\"316\"\u003ehigh-end hygienic flow measurement solution\u003c\/strong\u003e designed for \u003cstrong data-start=\"330\" data-end=\"378\"\u003eFood \u0026amp; Beverage and Life Sciences industries\u003c\/strong\u003e. It is optimized for demanding sanitary applications where \u003cstrong data-start=\"438\" data-end=\"497\"\u003ehigh accuracy, process safety, and advanced diagnostics\u003c\/strong\u003e are required.\u003c\/p\u003e\n\u003cp data-start=\"513\" data-end=\"786\"\u003eBased on the \u003cstrong data-start=\"526\" data-end=\"565\"\u003eelectromagnetic measuring principle\u003c\/strong\u003e, it provides \u003cstrong data-start=\"579\" data-end=\"635\"\u003ebidirectional flow measurement of conductive liquids\u003c\/strong\u003e, fully independent of pressure, density, temperature, and viscosity. This ensures stable and reliable performance even in variable process conditions.\u003c\/p\u003e\n\u003cp data-start=\"788\" data-end=\"952\"\u003eThe \u003cstrong data-start=\"792\" data-end=\"821\"\u003eremote transmitter design\u003c\/strong\u003e maximizes installation flexibility and operational safety, making it suitable for complex plant layouts and hygienic environments.\u003c\/p\u003e\n\u003cp data-start=\"954\" data-end=\"1071\"\u003eTypical applications include \u003cstrong data-start=\"983\" data-end=\"1070\"\u003edosing, filling, batching, CIP\/SIP processes, and hygienic liquid transport systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1073\" data-end=\"1215\"\u003eNot Recommended For:\u003cbr data-start=\"1093\" data-end=\"1096\"\u003e• Non-conductive liquids such as oils or hydrocarbons\u003cbr data-start=\"1149\" data-end=\"1152\"\u003e• Media with heavy solid content or strong abrasive particles\u003c\/p\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1250\" data-end=\"1269\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1271\" data-end=\"1832\"\u003e• Confirm the \u003cstrong data-start=\"1285\" data-end=\"1321\"\u003efluid is electrically conductive\u003c\/strong\u003e, required for electromagnetic measurement\u003cbr data-start=\"1363\" data-end=\"1366\"\u003e• Select appropriate \u003cstrong data-start=\"1387\" data-end=\"1421\"\u003enominal diameter (DN 2 to 150)\u003c\/strong\u003e based on pipeline size\u003cbr data-start=\"1444\" data-end=\"1447\"\u003e• Define required \u003cstrong data-start=\"1465\" data-end=\"1489\"\u003ecommunication system\u003c\/strong\u003e, such as HART, PROFIBUS, PROFINET, Modbus, Ethernet\/IP or OPC-UA\u003cbr data-start=\"1554\" data-end=\"1557\"\u003e• Choose \u003cstrong data-start=\"1566\" data-end=\"1587\"\u003eI\/O configuration\u003c\/strong\u003e, as device supports freely configurable multifunction I\/Os\u003cbr data-start=\"1646\" data-end=\"1649\"\u003e• Ensure \u003cstrong data-start=\"1658\" data-end=\"1683\"\u003ehygienic requirements\u003c\/strong\u003e, including EHEDG, 3-A, CIP\/SIP compatibility\u003cbr data-start=\"1728\" data-end=\"1731\"\u003e• Consider whether \u003cstrong data-start=\"1750\" data-end=\"1787\"\u003eHeartbeat Technology verification\u003c\/strong\u003e is required for compliance and diagnostics\u003c\/p\u003e\n\u003ch3 data-section-id=\"1r3s0lx\" data-start=\"1867\" data-end=\"1903\"\u003eWhy Choose the Promag H 500 5H5B\u003c\/h3\u003e\n\u003cp data-start=\"1905\" data-end=\"2118\"\u003e• \u003cstrong data-start=\"1907\" data-end=\"1951\"\u003eHigh-Precision Hygienic Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"1951\" data-end=\"1954\"\u003eThe electromagnetic principle provides accurate flow measurement for conductive liquids. Therefore, results are stable and independent of physical fluid properties.\u003c\/p\u003e\n\u003cp data-start=\"2120\" data-end=\"2295\"\u003e• \u003cstrong data-start=\"2122\" data-end=\"2160\"\u003eAdvanced Remote Transmitter Design\u003c\/strong\u003e\u003cbr data-start=\"2160\" data-end=\"2163\"\u003eThe separated transmitter improves installation flexibility and increases operational safety in hygienic and demanding environments.\u003c\/p\u003e\n\u003cp data-start=\"2297\" data-end=\"2488\"\u003e• \u003cstrong data-start=\"2299\" data-end=\"2339\"\u003eMultivariable Measurement Capability\u003c\/strong\u003e\u003cbr data-start=\"2339\" data-end=\"2342\"\u003eIt measures \u003cstrong data-start=\"2354\" data-end=\"2422\"\u003eflow, temperature, conductivity, mass flow, and corrected values\u003c\/strong\u003e. As a result, fewer instruments are required in the process line.\u003c\/p\u003e\n\u003cp data-start=\"2490\" data-end=\"2671\"\u003e• \u003cstrong data-start=\"2492\" data-end=\"2542\"\u003eHeartbeat Technology for Built-in Verification\u003c\/strong\u003e\u003cbr data-start=\"2542\" data-end=\"2545\"\u003eIntegrated diagnostics and verification ensure continuous compliance and process transparency without interrupting production.\u003c\/p\u003e\n\u003cp data-start=\"2673\" data-end=\"2840\"\u003e• \u003cstrong data-start=\"2675\" data-end=\"2717\"\u003eFlexible Communication and Integration\u003c\/strong\u003e\u003cbr data-start=\"2717\" data-end=\"2720\"\u003eSupports multiple industrial protocols, enabling seamless integration into modern automation systems and digital plants.\u003c\/p\u003e\n\u003cp data-start=\"2842\" data-end=\"3007\"\u003e• \u003cstrong data-start=\"2844\" data-end=\"2884\"\u003eHygienic and Maintenance-Free Design\u003c\/strong\u003e\u003cbr data-start=\"2884\" data-end=\"2887\"\u003eWith no moving parts and CIP\/SIP-compatible materials, the system ensures long-term reliability and minimal maintenance.\u003c\/p\u003e\n\u003cp data-start=\"3009\" data-end=\"3183\"\u003e• \u003cstrong data-start=\"3011\" data-end=\"3062\"\u003eOptimized for Food \u0026amp; Life Sciences Applications\u003c\/strong\u003e\u003cbr data-start=\"3062\" data-end=\"3065\"\u003eDesigned specifically for hygienic processes with strict regulatory requirements, ensuring safety and product quality.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3221\" data-end=\"3228\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3230\" data-end=\"3392\"\u003e\u003cstrong data-start=\"3230\" data-end=\"3271\"\u003eQ: What is the Promag H 500 used for?\u003c\/strong\u003e\u003cbr data-start=\"3271\" data-end=\"3274\"\u003eA: It is used for \u003cstrong data-start=\"3292\" data-end=\"3343\"\u003ehygienic flow measurement of conductive liquids\u003c\/strong\u003e in food, beverage, and life sciences industries.\u003c\/p\u003e\n\u003cp data-start=\"3394\" data-end=\"3607\"\u003e\u003cstrong data-start=\"3394\" data-end=\"3457\"\u003eQ: What makes Promag H 500 different from basic flowmeters?\u003c\/strong\u003e\u003cbr data-start=\"3457\" data-end=\"3460\"\u003eA: It offers \u003cstrong data-start=\"3473\" data-end=\"3563\"\u003eadvanced diagnostics, multivariable measurement, and Heartbeat Technology verification\u003c\/strong\u003e, making it suitable for critical processes.\u003c\/p\u003e\n\u003cp data-start=\"3609\" data-end=\"3730\"\u003e\u003cstrong data-start=\"3609\" data-end=\"3654\"\u003eQ: Can it measure non-conductive liquids?\u003c\/strong\u003e\u003cbr data-start=\"3654\" data-end=\"3657\"\u003eA: No. Electromagnetic flowmeters require electrically conductive fluids.\u003c\/p\u003e\n\u003cp data-start=\"3732\" data-end=\"3865\"\u003e\u003cstrong data-start=\"3732\" data-end=\"3780\"\u003eQ: Is it suitable for hygienic applications?\u003c\/strong\u003e\u003cbr data-start=\"3780\" data-end=\"3783\"\u003eA: Yes. It is fully compliant with \u003cstrong data-start=\"3818\" data-end=\"3864\"\u003eEHEDG, 3-A, and CIP\/SIP cleaning standards\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327903301693,"sku":null,"price":4000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-h500-5h5b-electromagnetic-flowmeter.webp?v=1783413127","url":"https:\/\/proinstru.com\/products\/e-h-proline-promag-h-500-5h5b-electromagnetic-flowmeter","provider":"Process Instrument","version":"1.0","type":"link"}