{"product_id":"e-h-proline-promag-h-300-5h3b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag H 300 5H3B electromagnetic flowmeter","description":"\u003cp data-start=\"184\" data-end=\"424\"\u003eThe \u003cstrong data-start=\"188\" data-end=\"258\"\u003eEndress+Hauser Proline Promag H 300 5H3B Electromagnetic Flowmeter\u003c\/strong\u003e is a \u003cstrong data-start=\"264\" data-end=\"303\"\u003ehigh-performance hygienic flowmeter\u003c\/strong\u003e designed for \u003cstrong data-start=\"317\" data-end=\"367\"\u003eFood \u0026amp; Beverage and Life Sciences applications\u003c\/strong\u003e requiring \u003cstrong data-start=\"378\" data-end=\"423\"\u003eaccuracy, flexibility, and process safety\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"426\" data-end=\"720\"\u003eIt uses the \u003cstrong data-start=\"438\" data-end=\"477\"\u003eelectromagnetic measuring principle\u003c\/strong\u003e to provide \u003cstrong data-start=\"489\" data-end=\"545\"\u003ebidirectional flow measurement of conductive liquids\u003c\/strong\u003e, independent of pressure, temperature, density, and viscosity. This ensures stable measurement even under changing process conditions.\u003c\/p\u003e\n\u003cp data-start=\"722\" data-end=\"954\"\u003eWith its \u003cstrong data-start=\"731\" data-end=\"816\"\u003ecompact transmitter design, flexible I\/O configuration, and advanced connectivity\u003c\/strong\u003e, Promag H 300 enables \u003cstrong data-start=\"839\" data-end=\"913\"\u003eeasy system integration and full access to process and diagnostic data\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"956\" data-end=\"1073\"\u003eTypical applications include \u003cstrong data-start=\"985\" data-end=\"1072\"\u003edosing, batching, filling, CIP\/SIP processes, and hygienic liquid transport systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1075\" data-end=\"1210\"\u003eNot Recommended For:\u003cbr data-start=\"1095\" data-end=\"1098\"\u003e• Non-conductive liquids such as oils or hydrocarbons\u003cbr data-start=\"1151\" data-end=\"1154\"\u003e• Media with heavy solids or strong abrasive particles\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1245\" data-end=\"1264\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1266\" data-end=\"1816\"\u003e• Confirm the \u003cstrong data-start=\"1280\" data-end=\"1302\"\u003efluid conductivity\u003c\/strong\u003e, as electromagnetic measurement requires conductive media\u003cbr data-start=\"1360\" data-end=\"1363\"\u003e• Select appropriate \u003cstrong data-start=\"1384\" data-end=\"1415\"\u003enominal diameter (DN 2–150)\u003c\/strong\u003e and hygienic process connection\u003cbr data-start=\"1447\" data-end=\"1450\"\u003e• Define required \u003cstrong data-start=\"1468\" data-end=\"1494\"\u003ecommunication protocol\u003c\/strong\u003e, such as HART, PROFINET, Modbus, or Ethernet-based systems\u003cbr data-start=\"1553\" data-end=\"1556\"\u003e• Choose \u003cstrong data-start=\"1565\" data-end=\"1586\"\u003eI\/O configuration\u003c\/strong\u003e, as Promag H 300 supports freely configurable inputs and outputs\u003cbr data-start=\"1651\" data-end=\"1654\"\u003e• Verify \u003cstrong data-start=\"1663\" data-end=\"1686\"\u003ehygienic compliance\u003c\/strong\u003e, including EHEDG, 3-A, and CIP\/SIP cleanability\u003cbr data-start=\"1734\" data-end=\"1737\"\u003e• Consider need for \u003cstrong data-start=\"1757\" data-end=\"1781\"\u003eHeartbeat Technology\u003c\/strong\u003e for verification and diagnostics\u003c\/p\u003e\n\u003ch3 data-section-id=\"oy5k45\" data-start=\"1851\" data-end=\"1887\"\u003eWhy Choose the Promag H 300 5H3B\u003c\/h3\u003e\n\u003cp data-start=\"1889\" data-end=\"2092\"\u003e• \u003cstrong data-start=\"1891\" data-end=\"1934\"\u003eHigh-Accuracy Hygienic Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"1934\" data-end=\"1937\"\u003eThe electromagnetic principle ensures reliable measurement of conductive liquids. Therefore, results remain stable regardless of process condition changes.\u003c\/p\u003e\n\u003cp data-start=\"2094\" data-end=\"2327\"\u003e• \u003cstrong data-start=\"2096\" data-end=\"2141\"\u003eCompact and Accessible Transmitter Design\u003c\/strong\u003e\u003cbr data-start=\"2141\" data-end=\"2144\"\u003eThe transmitter allows \u003cstrong data-start=\"2167\" data-end=\"2194\"\u003eoperation from one side\u003c\/strong\u003e, with optional remote display and WLAN access. This simplifies installation and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"2329\" data-end=\"2567\"\u003e• \u003cstrong data-start=\"2331\" data-end=\"2372\"\u003eFlexible Integration and Connectivity\u003c\/strong\u003e\u003cbr data-start=\"2372\" data-end=\"2375\"\u003eSupports multiple industrial communication protocols and \u003cstrong data-start=\"2432\" data-end=\"2460\"\u003efreely configurable I\/Os\u003c\/strong\u003e. As a result, it integrates easily into modern automation systems.\u003c\/p\u003e\n\u003cp data-start=\"2569\" data-end=\"2722\"\u003e• \u003cstrong data-start=\"2571\" data-end=\"2615\"\u003eFull Process and Diagnostic Transparency\u003c\/strong\u003e\u003cbr data-start=\"2615\" data-end=\"2618\"\u003eProvides continuous access to \u003cstrong data-start=\"2648\" data-end=\"2687\"\u003eprocess data and device diagnostics\u003c\/strong\u003e, improving operational visibility.\u003c\/p\u003e\n\u003cp data-start=\"2724\" data-end=\"2917\"\u003e• \u003cstrong data-start=\"2726\" data-end=\"2767\"\u003eHeartbeat Technology for Verification\u003c\/strong\u003e\u003cbr data-start=\"2767\" data-end=\"2770\"\u003eBuilt-in verification enables \u003cstrong data-start=\"2800\" data-end=\"2844\"\u003econtinuous compliance and process safety\u003c\/strong\u003e without interrupting production.\u003c\/p\u003e\n\u003cp data-start=\"2919\" data-end=\"3149\"\u003e• \u003cstrong data-start=\"2921\" data-end=\"2961\"\u003eHygienic and Maintenance-Free Design\u003c\/strong\u003e\u003cbr data-start=\"2961\" data-end=\"2964\"\u003eConstructed with \u003cstrong data-start=\"2981\" data-end=\"3022\"\u003ePFA liner and stainless steel housing\u003c\/strong\u003e, and fully \u003cstrong data-start=\"3034\" data-end=\"3055\"\u003eCIP\/SIP cleanable\u003c\/strong\u003e, ensuring long-term reliability with no moving parts.\u003c\/p\u003e\n\u003cp data-start=\"3151\" data-end=\"3329\"\u003e• \u003cstrong data-start=\"3153\" data-end=\"3185\"\u003eEnergy-Efficient Measurement\u003c\/strong\u003e\u003cbr data-start=\"3185\" data-end=\"3188\"\u003eNo pressure loss due to unobstructed flow path. Consequently, system energy consumption is minimized.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3367\" data-end=\"3374\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3376\" data-end=\"3568\"\u003e\u003cstrong data-start=\"3376\" data-end=\"3430\"\u003eQ: What applications is Promag H 300 suitable for?\u003c\/strong\u003e\u003cbr data-start=\"3430\" data-end=\"3433\"\u003eA: It is designed for \u003cstrong data-start=\"3455\" data-end=\"3517\"\u003ehygienic applications in food, beverage, and life sciences\u003c\/strong\u003e, including filling, dosing, and CIP\/SIP processes.\u003c\/p\u003e\n\u003cp data-start=\"3570\" data-end=\"3789\"\u003e\u003cstrong data-start=\"3570\" data-end=\"3629\"\u003eQ: What makes Promag H 300 different from basic models?\u003c\/strong\u003e\u003cbr data-start=\"3629\" data-end=\"3632\"\u003eA: It offers \u003cstrong data-start=\"3645\" data-end=\"3735\"\u003eadvanced connectivity, flexible I\/O configuration, and integrated Heartbeat Technology\u003c\/strong\u003e, providing better diagnostics and system integration.\u003c\/p\u003e\n\u003cp data-start=\"3791\" data-end=\"3912\"\u003e\u003cstrong data-start=\"3791\" data-end=\"3836\"\u003eQ: Can it measure non-conductive liquids?\u003c\/strong\u003e\u003cbr data-start=\"3836\" data-end=\"3839\"\u003eA: No. Electromagnetic flowmeters require electrically conductive fluids.\u003c\/p\u003e\n\u003cp data-start=\"3914\" data-end=\"4046\"\u003e\u003cstrong data-start=\"3914\" data-end=\"3959\"\u003eQ: Is it suitable for hygienic processes?\u003c\/strong\u003e\u003cbr data-start=\"3959\" data-end=\"3962\"\u003eA: Yes. It complies with \u003cstrong data-start=\"3987\" data-end=\"4011\"\u003eEHEDG, 3-A standards\u003c\/strong\u003e and supports \u003cstrong data-start=\"4025\" data-end=\"4045\"\u003eCIP\/SIP cleaning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327905824829,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-h300-5h3b-electromagnetic-flowmeter.webp?v=1783413354","url":"https:\/\/proinstru.com\/products\/e-h-proline-promag-h-300-5h3b-electromagnetic-flowmeter","provider":"Process Instrument","version":"1.0","type":"link"}