{"product_id":"e-h-proline-promag-h-200-5h2b-electromagnetic-flowmeter","title":"Endress+Hauser  Proline Promag H 200 5H2B electromagnetic flowmeter","description":"\u003cp data-start=\"215\" data-end=\"533\"\u003eThe \u003cstrong data-start=\"219\" data-end=\"289\"\u003eEndress+Hauser Proline Promag H 200 5H2B Electromagnetic Flowmeter\u003c\/strong\u003e is designed for \u003cstrong data-start=\"306\" data-end=\"356\"\u003ehigh-precision measurement of small flow rates\u003c\/strong\u003e in \u003cstrong data-start=\"360\" data-end=\"401\"\u003echemical and life sciences industries\u003c\/strong\u003e. It features \u003cstrong data-start=\"415\" data-end=\"450\"\u003egenuine loop-powered technology\u003c\/strong\u003e, enabling cost-effective integration without the need for additional power supply.\u003c\/p\u003e\n\u003cp data-start=\"535\" data-end=\"836\"\u003eUsing the \u003cstrong data-start=\"545\" data-end=\"584\"\u003eelectromagnetic measuring principle\u003c\/strong\u003e, it provides \u003cstrong data-start=\"598\" data-end=\"663\"\u003eaccurate bidirectional flow measurement of conductive liquids\u003c\/strong\u003e, independent of pressure, temperature, density, and viscosity. This ensures stable performance even in demanding process conditions.\u003c\/p\u003e\n\u003cp data-start=\"838\" data-end=\"998\"\u003eThe intrinsically safe design makes it suitable for \u003cstrong data-start=\"890\" data-end=\"909\"\u003ehazardous areas\u003c\/strong\u003e, while \u003cstrong data-start=\"917\" data-end=\"941\"\u003eHeartbeat Technology\u003c\/strong\u003e ensures continuous process reliability and verification.\u003c\/p\u003e\n\u003cp data-start=\"1000\" data-end=\"1124\"\u003eTypical applications include \u003cstrong data-start=\"1029\" data-end=\"1123\"\u003edosing, small-volume measurement, pharmaceutical processes, and chemical injection systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1126\" data-end=\"1258\"\u003eNot Recommended For:\u003cbr data-start=\"1146\" data-end=\"1149\"\u003e• Non-conductive liquids such as oils or hydrocarbons\u003cbr data-start=\"1202\" data-end=\"1205\"\u003e• Applications with large solids or strong abrasion\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1293\" data-end=\"1312\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1314\" data-end=\"2035\"\u003e• Confirm the \u003cstrong data-start=\"1328\" data-end=\"1364\"\u003efluid is electrically conductive\u003c\/strong\u003e, required for electromagnetic measurement\u003cbr data-start=\"1406\" data-end=\"1409\"\u003e• Verify \u003cstrong data-start=\"1418\" data-end=\"1443\"\u003esmall flow rate range\u003c\/strong\u003e, especially for dosing or micro-flow applications (down to very low flow rates) \u003cbr data-start=\"1561\" data-end=\"1564\"\u003e• Select appropriate \u003cstrong data-start=\"1585\" data-end=\"1615\"\u003enominal diameter (DN 2–25)\u003c\/strong\u003e for small pipelines \u003cbr data-start=\"1673\" data-end=\"1676\"\u003e• Choose required \u003cstrong data-start=\"1694\" data-end=\"1720\"\u003ecommunication protocol\u003c\/strong\u003e, such as HART, PROFIBUS PA, or FOUNDATION Fieldbus \u003cbr data-start=\"1809\" data-end=\"1812\"\u003e• Ensure \u003cstrong data-start=\"1821\" data-end=\"1860\"\u003ehazardous area requirements (Ex ia)\u003c\/strong\u003e if installed in explosive environments \u003cbr data-start=\"1937\" data-end=\"1940\"\u003e• Confirm \u003cstrong data-start=\"1950\" data-end=\"1988\"\u003ehygienic or chemical compatibility\u003c\/strong\u003e, including PFA liner and electrode materials\u003c\/p\u003e\n\u003ch3 data-section-id=\"1d1h8t1\" data-start=\"2070\" data-end=\"2106\"\u003eWhy Choose the Promag H 200 5H2B\u003c\/h3\u003e\n\u003cp data-start=\"2108\" data-end=\"2311\"\u003e• \u003cstrong data-start=\"2110\" data-end=\"2150\"\u003eOptimized for Small Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"2150\" data-end=\"2153\"\u003eDesigned specifically for \u003cstrong data-start=\"2179\" data-end=\"2202\"\u003every low flow rates\u003c\/strong\u003e, making it ideal for dosing and precise liquid control applications.\u003c\/p\u003e\n\u003cp data-start=\"2313\" data-end=\"2495\"\u003e• \u003cstrong data-start=\"2315\" data-end=\"2351\"\u003eLoop-Powered Technology (2-Wire)\u003c\/strong\u003e\u003cbr data-start=\"2351\" data-end=\"2354\"\u003eOperates without additional power supply. Therefore, installation is simpler and more cost-efficient.\u003c\/p\u003e\n\u003cp data-start=\"2497\" data-end=\"2682\"\u003e• \u003cstrong data-start=\"2499\" data-end=\"2539\"\u003eIntrinsic Safety for Hazardous Areas\u003c\/strong\u003e\u003cbr data-start=\"2539\" data-end=\"2542\"\u003eCertified for \u003cstrong data-start=\"2556\" data-end=\"2578\"\u003eEx ia environments\u003c\/strong\u003e, ensuring safe operation in chemical and explosive atmospheres.\u003c\/p\u003e\n\u003cp data-start=\"2684\" data-end=\"2850\"\u003e• \u003cstrong data-start=\"2686\" data-end=\"2715\"\u003eHigh Measurement Accuracy\u003c\/strong\u003e\u003cbr data-start=\"2715\" data-end=\"2718\"\u003eAchieves up to \u003cstrong data-start=\"2733\" data-end=\"2751\"\u003e±0.5% accuracy\u003c\/strong\u003e, ensuring reliable process control even at low flow rates.\u003c\/p\u003e\n\u003cp data-start=\"2852\" data-end=\"2987\"\u003e• \u003cstrong data-start=\"2854\" data-end=\"2903\"\u003eHeartbeat Technology for Process Verification\u003c\/strong\u003e\u003cbr data-start=\"2903\" data-end=\"2906\"\u003eEnables continuous diagnostics and verification without interrupting the process.\u003c\/p\u003e\n\u003cp data-start=\"2989\" data-end=\"3186\"\u003e• \u003cstrong data-start=\"2991\" data-end=\"3034\"\u003eHygienic and Corrosion-Resistant Design\u003c\/strong\u003e\u003cbr data-start=\"3034\" data-end=\"3037\"\u003eFeatures \u003cstrong data-start=\"3046\" data-end=\"3087\"\u003ePFA liner and stainless steel housing\u003c\/strong\u003e, suitable for aggressive chemicals and hygienic processes.\u003c\/p\u003e\n\u003cp data-start=\"3188\" data-end=\"3347\"\u003e• \u003cstrong data-start=\"3190\" data-end=\"3220\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"3220\" data-end=\"3223\"\u003eNo moving parts and no pressure loss. Consequently, operating costs are minimized.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3385\" data-end=\"3392\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3394\" data-end=\"3558\"\u003e\u003cstrong data-start=\"3394\" data-end=\"3438\"\u003eQ: What is Promag H 200 mainly used for?\u003c\/strong\u003e\u003cbr data-start=\"3438\" data-end=\"3441\"\u003eA: It is designed for \u003cstrong data-start=\"3463\" data-end=\"3494\"\u003esmall flow rate measurement\u003c\/strong\u003e, especially in chemical dosing and pharmaceutical applications.\u003c\/p\u003e\n\u003cp data-start=\"3560\" data-end=\"3778\"\u003e\u003cstrong data-start=\"3560\" data-end=\"3616\"\u003eQ: What makes it different from Promag H 300 or 500?\u003c\/strong\u003e\u003cbr data-start=\"3616\" data-end=\"3619\"\u003eA: Promag H 200 focuses on \u003cstrong data-start=\"3646\" data-end=\"3704\"\u003eloop-powered, compact, and hazardous-area applications\u003c\/strong\u003e, while higher models provide more advanced communication and diagnostics.\u003c\/p\u003e\n\u003cp data-start=\"3780\" data-end=\"3936\"\u003e\u003cstrong data-start=\"3780\" data-end=\"3821\"\u003eQ: Can it be used in hazardous areas?\u003c\/strong\u003e\u003cbr data-start=\"3821\" data-end=\"3824\"\u003eA: Yes. It supports \u003cstrong data-start=\"3844\" data-end=\"3888\"\u003eintrinsically safe (Ex ia) installations\u003c\/strong\u003e, making it suitable for explosive environments.\u003c\/p\u003e\n\u003cp data-start=\"3938\" data-end=\"4082\"\u003e\u003cstrong data-start=\"3938\" data-end=\"3973\"\u003eQ: What liquids can it measure?\u003c\/strong\u003e\u003cbr data-start=\"3973\" data-end=\"3976\"\u003eA: It measures \u003cstrong data-start=\"3991\" data-end=\"4026\"\u003eelectrically conductive liquids\u003c\/strong\u003e, including chemicals, acids, and pharmaceutical fluids.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327928270909,"sku":null,"price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-h200-5h2b-electromagnetic-flowmeter.webp?v=1783413917","url":"https:\/\/proinstru.com\/products\/e-h-proline-promag-h-200-5h2b-electromagnetic-flowmeter","provider":"Process Instrument","version":"1.0","type":"link"}