{"product_id":"e-h-dma-picomag-inline-electromagnetic-flowmeter","title":"Endress+Hauser DMA Picomag Inline electromagnetic flowmeter","description":"\u003cp data-start=\"250\" data-end=\"616\"\u003eThe \u003cstrong data-start=\"254\" data-end=\"326\"\u003eEndress+Hauser Picomag Inline electromagnetic flowmeter (DMA series)\u003c\/strong\u003e is a compact and versatile flowmeter designed for \u003cstrong data-start=\"377\" data-end=\"448\"\u003eprocess monitoring and utility applications with conductive liquids\u003c\/strong\u003e. It combines \u003cstrong data-start=\"462\" data-end=\"512\"\u003eflow, temperature and conductivity measurement\u003c\/strong\u003e in a single device, reducing the need for multiple instruments.\u003c\/p\u003e\n\u003cp data-start=\"618\" data-end=\"892\"\u003eThis device features a fully integrated design with sensor and transmitter in one housing. In addition, it supports \u003cstrong data-start=\"734\" data-end=\"783\"\u003eBluetooth configuration via the SmartBlue app\u003c\/strong\u003e, allowing fast and convenient setup even in hard-to-reach locations.\u003c\/p\u003e\n\u003cp data-start=\"894\" data-end=\"1006\"\u003eTypical applications include cooling water circuits, skid systems, utilities and general industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"1008\" data-end=\"1136\"\u003eNot Recommended For:\u003cbr data-start=\"1028\" data-end=\"1031\"\u003e• Non-conductive liquids such as oil or gas\u003cbr data-start=\"1074\" data-end=\"1077\"\u003e• High-temperature or high-pressure primary process lines\u003c\/p\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1171\" data-end=\"1190\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1192\" data-end=\"1788\"\u003e• Confirm that the \u003cstrong data-start=\"1211\" data-end=\"1248\"\u003emedium is electrically conductive\u003c\/strong\u003e, as required for electromagnetic measurement\u003cbr data-start=\"1293\" data-end=\"1296\"\u003e• Verify the \u003cstrong data-start=\"1309\" data-end=\"1323\"\u003eflow range\u003c\/strong\u003e, which can reach up to \u003cstrong data-start=\"1347\" data-end=\"1360\"\u003e750 L\/min\u003c\/strong\u003e depending on size \u003cbr data-start=\"1416\" data-end=\"1419\"\u003e• Check the \u003cstrong data-start=\"1431\" data-end=\"1454\"\u003eprocess temperature\u003c\/strong\u003e, typically \u003cstrong data-start=\"1466\" data-end=\"1486\"\u003e-10 °C to +70 °C\u003c\/strong\u003e (short-term up to 85 °C) \u003cbr data-start=\"1549\" data-end=\"1552\"\u003e• Ensure the \u003cstrong data-start=\"1565\" data-end=\"1585\"\u003eprocess pressure\u003c\/strong\u003e does not exceed \u003cstrong data-start=\"1602\" data-end=\"1612\"\u003e16 bar\u003c\/strong\u003e \u003cbr data-start=\"1650\" data-end=\"1653\"\u003e• In addition, confirm compatibility with \u003cstrong data-start=\"1695\" data-end=\"1725\"\u003eIO-Link or digital outputs\u003c\/strong\u003e for system integration\u003c\/p\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1171\" data-end=\"1190\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1192\" data-end=\"1788\"\u003e• Confirm that the \u003cstrong data-start=\"1211\" data-end=\"1248\"\u003emedium is electrically conductive\u003c\/strong\u003e, as required for electromagnetic measurement\u003cbr data-start=\"1293\" data-end=\"1296\"\u003e• Verify the \u003cstrong data-start=\"1309\" data-end=\"1323\"\u003eflow range\u003c\/strong\u003e, which can reach up to \u003cstrong data-start=\"1347\" data-end=\"1360\"\u003e750 L\/min\u003c\/strong\u003e depending on size \u003cbr data-start=\"1416\" data-end=\"1419\"\u003e• Check the \u003cstrong data-start=\"1431\" data-end=\"1454\"\u003eprocess temperature\u003c\/strong\u003e, typically \u003cstrong data-start=\"1466\" data-end=\"1486\"\u003e-10 °C to +70 °C\u003c\/strong\u003e (short-term up to 85 °C) \u003cbr data-start=\"1549\" data-end=\"1552\"\u003e• Ensure the \u003cstrong data-start=\"1565\" data-end=\"1585\"\u003eprocess pressure\u003c\/strong\u003e does not exceed \u003cstrong data-start=\"1602\" data-end=\"1612\"\u003e16 bar\u003c\/strong\u003e \u003cbr data-start=\"1650\" data-end=\"1653\"\u003e• In addition, confirm compatibility with \u003cstrong data-start=\"1695\" data-end=\"1725\"\u003eIO-Link or digital outputs\u003c\/strong\u003e for system integration\u003c\/p\u003e\n\u003ch3 data-section-id=\"f42xgj\" data-start=\"1823\" data-end=\"1859\"\u003eWhy Choose the Picomag Flowmeter\u003c\/h3\u003e\n\u003cp data-start=\"1861\" data-end=\"2070\"\u003e• \u003cstrong data-start=\"1863\" data-end=\"1896\"\u003e3-in-1 Measurement Capability\u003c\/strong\u003e\u003cbr data-start=\"1896\" data-end=\"1899\"\u003eThe device measures \u003cstrong data-start=\"1919\" data-end=\"1972\"\u003eflow, temperature and conductivity simultaneously\u003c\/strong\u003e. Therefore, fewer instruments are required in the system.\u003c\/p\u003e\n\u003cp data-start=\"2072\" data-end=\"2268\"\u003e• \u003cstrong data-start=\"2074\" data-end=\"2103\"\u003eCompact All-in-One Design\u003c\/strong\u003e\u003cbr data-start=\"2103\" data-end=\"2106\"\u003eSensor and transmitter are integrated into one housing. As a result, installation space and wiring complexity are reduced.\u003c\/p\u003e\n\u003cp data-start=\"2270\" data-end=\"2489\"\u003e• \u003cstrong data-start=\"2272\" data-end=\"2308\"\u003eEasy Commissioning via Bluetooth\u003c\/strong\u003e\u003cbr data-start=\"2308\" data-end=\"2311\"\u003eConfiguration can be completed using the SmartBlue app. In addition, wireless access simplifies setup in difficult installation positions.\u003c\/p\u003e\n\u003cp data-start=\"2491\" data-end=\"2739\"\u003e• \u003cstrong data-start=\"2493\" data-end=\"2551\"\u003eReliable Measurement Independent of Process Conditions\u003c\/strong\u003e\u003cbr data-start=\"2551\" data-end=\"2554\"\u003eThe electromagnetic principle is unaffected by density, viscosity or pressure. Consequently, measurement remains stable under varying conditions.\u003c\/p\u003e\n\u003cp data-start=\"2741\" data-end=\"2959\"\u003e• \u003cstrong data-start=\"2743\" data-end=\"2780\"\u003eFlexible Integration with IO-Link\u003c\/strong\u003e\u003cbr data-start=\"2780\" data-end=\"2783\"\u003eThe flowmeter supports \u003cstrong data-start=\"2806\" data-end=\"2842\"\u003eIO-Link and multiple I\/O options\u003c\/strong\u003e. Therefore, integration into modern automation systems is straightforward.\u003c\/p\u003e\n\u003cp data-start=\"2961\" data-end=\"3165\"\u003e• \u003cstrong data-start=\"2963\" data-end=\"2991\"\u003eRobust Industrial Design\u003c\/strong\u003e\u003cbr data-start=\"2991\" data-end=\"2994\"\u003eIt offers \u003cstrong data-start=\"3004\" data-end=\"3028\"\u003eIP65\/IP67 protection\u003c\/strong\u003e and strong vibration resistance. This ensures reliable performance in industrial environments.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325752737853,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/picomag-dma-inline-flowmeter.webp?v=1783309621","url":"https:\/\/proinstru.com\/products\/e-h-dma-picomag-inline-electromagnetic-flowmeter","provider":"Process Instrument","version":"1.0","type":"link"}