{"product_id":"e-h-55s-proline-promag-55s-electromagnetic-flowmeter","title":"Endress+Hauser 55S Proline Promag 55S electromagnetic flowmeter","description":"\u003ch3 data-section-id=\"uztocl\" data-start=\"1148\" data-end=\"1167\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1169\" data-end=\"1833\"\u003e• Confirm that the \u003cstrong data-start=\"1188\" data-end=\"1232\"\u003emedium is conductive and contains solids\u003c\/strong\u003e, as this model is optimized for such conditions\u003cbr data-start=\"1280\" data-end=\"1283\"\u003e• Verify the \u003cstrong data-start=\"1296\" data-end=\"1310\"\u003eflow range\u003c\/strong\u003e, typically from \u003cstrong data-start=\"1327\" data-end=\"1355\"\u003e0.06 dm³\/min to 600 m³\/h\u003c\/strong\u003e \u003cbr data-start=\"1393\" data-end=\"1396\"\u003e• Choose the correct \u003cstrong data-start=\"1417\" data-end=\"1435\"\u003eliner material\u003c\/strong\u003e (e.g., polyurethane, rubber, PTFE) based on abrasion and chemical resistance \u003cbr data-start=\"1550\" data-end=\"1553\"\u003e• Check the \u003cstrong data-start=\"1565\" data-end=\"1588\"\u003eprocess temperature\u003c\/strong\u003e, which can reach up to \u003cstrong data-start=\"1612\" data-end=\"1622\"\u003e180 °C\u003c\/strong\u003e depending on configuration \u003cbr data-start=\"1687\" data-end=\"1690\"\u003e• In addition, ensure the \u003cstrong data-start=\"1716\" data-end=\"1735\"\u003epressure rating\u003c\/strong\u003e (up to PN40 \/ Class 300) matches your system requirements\u003c\/p\u003e\n\u003ch3 data-section-id=\"16zb9td\" data-start=\"1868\" data-end=\"1897\"\u003eWhy Choose the Promag 55S\u003c\/h3\u003e\n\u003cp data-start=\"1899\" data-end=\"2128\"\u003e• \u003cstrong data-start=\"1901\" data-end=\"1948\"\u003eDesigned for Abrasive and High-Solids Media\u003c\/strong\u003e\u003cbr data-start=\"1948\" data-end=\"1951\"\u003eThis model is specifically built for \u003cstrong data-start=\"1988\" data-end=\"2023\"\u003eslurry and solids-laden liquids\u003c\/strong\u003e. Therefore, it performs reliably where standard flowmeters fail.\u003c\/p\u003e\n\u003cp data-start=\"2130\" data-end=\"2347\"\u003e• \u003cstrong data-start=\"2132\" data-end=\"2173\"\u003eIntegrated Solids Content Measurement\u003c\/strong\u003e\u003cbr data-start=\"2173\" data-end=\"2176\"\u003eThe transmitter can calculate \u003cstrong data-start=\"2206\" data-end=\"2230\"\u003esolids concentration\u003c\/strong\u003e in addition to flow. As a result, process monitoring becomes more efficient.\u003c\/p\u003e\n\u003cp data-start=\"2349\" data-end=\"2578\"\u003e• \u003cstrong data-start=\"2351\" data-end=\"2399\"\u003eExcellent Durability with Specialized Liners\u003c\/strong\u003e\u003cbr data-start=\"2399\" data-end=\"2402\"\u003eA wide range of liner materials improves resistance to wear and corrosion. Consequently, service life is extended in harsh environments.\u003c\/p\u003e\n\u003cp data-start=\"2580\" data-end=\"2822\"\u003e• \u003cstrong data-start=\"2582\" data-end=\"2637\"\u003eStable Measurement \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2580\" data-end=\"2822\"\u003e\u003cstrong data-start=\"2582\" data-end=\"2637\"\u003eIndependent of Process Variables\u003c\/strong\u003e\u003cbr data-start=\"2637\" data-end=\"2640\"\u003eThe electromagnetic principle is unaffected by density, viscosity or pressure. Therefore, measurement remains stable under varying conditions.\u003c\/p\u003e\n\u003cp data-start=\"2824\" data-end=\"3001\"\u003e• \u003cstrong data-start=\"2826\" data-end=\"2856\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"2856\" data-end=\"2859\"\u003eThere are no moving parts inside the sensor. This design reduces maintenance and minimizes downtime.\u003c\/p\u003e\n\u003cp data-start=\"3003\" data-end=\"3215\"\u003e• \u003cstrong data-start=\"3005\" data-end=\"3047\"\u003eAdvanced Communication and Diagnostics\u003c\/strong\u003e\u003cbr data-start=\"3047\" data-end=\"3050\"\u003eIt supports \u003cstrong data-start=\"3062\" data-end=\"3110\"\u003eHART, PROFIBUS PA\/DP and FOUNDATION Fieldbus\u003c\/strong\u003e. In addition, built-in diagnostics improve operational safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3253\" data-end=\"3260\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3262\" data-end=\"3505\"\u003e\u003cstrong data-start=\"3262\" data-end=\"3330\"\u003eQ: What makes Promag 55S different from standard mag flowmeters?\u003c\/strong\u003e\u003cbr data-start=\"3330\" data-end=\"3333\"\u003eA: It is specifically designed for \u003cstrong data-start=\"3368\" data-end=\"3402\"\u003eabrasive and high-solids media\u003c\/strong\u003e, with enhanced durability and solids measurement capability.\u003c\/p\u003e\n\u003cp data-start=\"3507\" data-end=\"3699\"\u003e\u003cstrong data-start=\"3507\" data-end=\"3558\"\u003eQ: What industries commonly use this flowmeter?\u003c\/strong\u003e\u003cbr data-start=\"3558\" data-end=\"3561\"\u003eA: It is widely used in \u003cstrong data-start=\"3585\" data-end=\"3656\"\u003emining, wastewater treatment, pulp and paper, and metals processing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3701\" data-end=\"3872\"\u003e\u003cstrong data-start=\"3701\" data-end=\"3741\"\u003eQ: What is the measurement accuracy?\u003c\/strong\u003e\u003cbr data-start=\"3741\" data-end=\"3744\"\u003eA: Standard accuracy is \u003cstrong data-start=\"3768\" data-end=\"3788\"\u003e±0.5% of reading\u003c\/strong\u003e, with optional higher accuracy available.\u003c\/p\u003e\n\u003cp data-start=\"3874\" data-end=\"4034\"\u003e\u003cstrong data-start=\"3874\" data-end=\"3909\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-start=\"3909\" data-end=\"3912\"\u003eA: No. Because it has \u003cstrong data-start=\"3934\" data-end=\"3953\"\u003eno moving parts\u003c\/strong\u003e, maintenance requirements are minimal.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325742940221,"sku":null,"price":1350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-55s-electromagnetic-flowmeter1.webp?v=1783407998","url":"https:\/\/proinstru.com\/products\/e-h-55s-proline-promag-55s-electromagnetic-flowmeter","provider":"Process Instrument","version":"1.0","type":"link"}