{"title":"Yokogawa","description":"\u003cp data-start=\"105\" data-end=\"395\" class=\"PDq2pG_selectionAnchorContainer\"\u003eYokogawa is a global provider of industrial automation, process control, and measurement solutions, offering advanced technologies for monitoring, control, and operational efficiency. Its products are widely used in oil \u0026amp; gas, chemical, power, water treatment, and manufacturing industries.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"397\" data-end=\"560\"\u003eKnown for reliability, precision, and innovation, Yokogawa solutions help improve productivity, process safety, and performance in complex industrial environments.\u003c\/p\u003e","products":[{"product_id":"yokogawa-ejx120a-differential-pressure-transmitter","title":"Yokogawa EJX120A Differential Pressure Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"768\" data-end=\"804\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"806\" data-end=\"996\"\u003eThe \u003cstrong data-start=\"810\" data-end=\"864\"\u003eYokogawa EJX120A Differential Pressure Transmitter\u003c\/strong\u003e is a high-performance draft range DP transmitter designed for precise measurement of differential pressure in industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"998\" data-end=\"1310\"\u003eBased on Yokogawa’s advanced \u003cstrong data-start=\"1027\" data-end=\"1063\"\u003eDPharp digital sensor technology\u003c\/strong\u003e, it provides high stability, fast response, and long-term accuracy. It is widely used for \u003cstrong data-start=\"1154\" data-end=\"1203\"\u003eliquid level measurement in pressurized tanks\u003c\/strong\u003e, \u003cstrong data-start=\"1205\" data-end=\"1247\"\u003eflow measurement with primary elements\u003c\/strong\u003e, and \u003cstrong data-start=\"1253\" data-end=\"1309\"\u003edensity or interface detection in process industries\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1312\" data-end=\"1556\"\u003eThe EJX120A is known for its excellent long-term stability and diagnostic capabilities, helping reduce maintenance costs and improve process reliability in demanding environments such as oil \u0026amp; gas, chemical plants, and power generation systems.\u003c\/p\u003e\n\u003cp data-start=\"1558\" data-end=\"1742\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1589\" data-end=\"1626\"\u003edifferential pressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1628\" data-end=\"1646\"\u003eDP transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1648\" data-end=\"1681\"\u003eYokogawa pressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1683\" data-end=\"1716\"\u003elevel measurement transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1718\" data-end=\"1742\"\u003eindustrial DP sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1744\" data-end=\"1747\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1749\" data-end=\"1765\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1767\" data-end=\"2149\"\u003e• High-precision DPharp digital sensor technology\u003cbr data-start=\"1816\" data-end=\"1819\"\u003e• Accuracy up to ±0.09% of span\u003cbr data-start=\"1850\" data-end=\"1853\"\u003e• Fast response time (150 ms)\u003cbr data-start=\"1882\" data-end=\"1885\"\u003e• Long-term stability ±0.15% per year\u003cbr data-start=\"1922\" data-end=\"1925\"\u003e• Suitable for liquid, gas, and steam applications\u003cbr data-start=\"1975\" data-end=\"1978\"\u003e• SIL2 \/ SIL3 safety certification\u003cbr data-start=\"2012\" data-end=\"2015\"\u003e• HART \/ Fieldbus communication options\u003cbr data-start=\"2054\" data-end=\"2057\"\u003e• Advanced diagnostics for impulse line detection\u003cbr data-start=\"2106\" data-end=\"2109\"\u003e• Robust industrial-grade construction\u003c\/p\u003e\n\u003chr data-start=\"2151\" data-end=\"2154\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"2156\" data-end=\"2182\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2184\" data-end=\"2460\"\u003e\n\u003cli data-section-id=\"1tclxpy\" data-start=\"2184\" data-end=\"2222\"\u003ePressurized tank level measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1jrzd90\" data-start=\"2223\" data-end=\"2264\"\u003eFlow measurement using orifice plates\u003c\/li\u003e\n\u003cli data-section-id=\"1820j57\" data-start=\"2265\" data-end=\"2296\"\u003eChemical process monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"ejdnol\" data-start=\"2297\" data-end=\"2327\"\u003eOil \u0026amp; gas pipeline systems\u003c\/li\u003e\n\u003cli data-section-id=\"1x31490\" data-start=\"2328\" data-end=\"2356\"\u003eSteam and boiler systems\u003c\/li\u003e\n\u003cli data-section-id=\"1u0vjpw\" data-start=\"2357\" data-end=\"2394\"\u003eDensity and interface measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1xzh7uk\" data-start=\"2395\" data-end=\"2426\"\u003ePower plant process control\u003c\/li\u003e\n\u003cli data-section-id=\"xwcxty\" data-start=\"2427\" data-end=\"2460\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2462\" data-end=\"2465\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2467\" data-end=\"2500\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2502\" data-end=\"2536\"\u003eBefore selecting EJX120A, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2538\" data-end=\"2881\"\u003e\n\u003cli data-section-id=\"1v40a4h\" data-start=\"2538\" data-end=\"2602\"\u003eRequired differential pressure range (draft range selection)\u003c\/li\u003e\n\u003cli data-section-id=\"1qobu8o\" data-start=\"2603\" data-end=\"2646\"\u003eStatic pressure conditions (MWP limits)\u003c\/li\u003e\n\u003cli data-section-id=\"10qmym3\" data-start=\"2647\" data-end=\"2685\"\u003eMedium type (liquid \/ gas \/ steam)\u003c\/li\u003e\n\u003cli data-section-id=\"10u9tom\" data-start=\"2686\" data-end=\"2737\"\u003eInstallation type (flanged \/ manifold mounting)\u003c\/li\u003e\n\u003cli data-section-id=\"1nzjwqo\" data-start=\"2738\" data-end=\"2785\"\u003eOutput protocol (4–20 mA \/ HART \/ Fieldbus)\u003c\/li\u003e\n\u003cli data-section-id=\"1buonto\" data-start=\"2786\" data-end=\"2836\"\u003eSafety certification requirement (SIL2 \/ SIL3)\u003c\/li\u003e\n\u003cli data-section-id=\"1bmmtbe\" data-start=\"2837\" data-end=\"2881\"\u003eNeed for remote configuration or display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2883\" data-end=\"2886\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2888\" data-end=\"2902\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2904\" data-end=\"3081\"\u003e\u003cstrong data-start=\"2904\" data-end=\"2945\"\u003eQ: What is Yokogawa EJX120A used for?\u003c\/strong\u003e\u003cbr data-start=\"2945\" data-end=\"2948\"\u003eA: It is used for differential pressure measurement in level, flow, and density applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3083\" data-end=\"3238\"\u003e\u003cstrong data-start=\"3083\" data-end=\"3123\"\u003eQ: What technology does EJX120A use?\u003c\/strong\u003e\u003cbr data-start=\"3123\" data-end=\"3126\"\u003eA: It uses Yokogawa’s DPharp digital resonant silicon sensor technology. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3240\" data-end=\"3365\"\u003e\u003cstrong data-start=\"3240\" data-end=\"3279\"\u003eQ: What is the accuracy of EJX120A?\u003c\/strong\u003e\u003cbr data-start=\"3279\" data-end=\"3282\"\u003eA: It offers up to ±0.09% accuracy of span. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3367\" data-end=\"3493\"\u003e\u003cstrong data-start=\"3367\" data-end=\"3411\"\u003eQ: Can it be used for level measurement?\u003c\/strong\u003e\u003cbr data-start=\"3411\" data-end=\"3414\"\u003eA: Yes, it is widely used for differential pressure level measurement in tanks.\u003c\/p\u003e\n\u003cp data-start=\"3495\" data-end=\"3610\"\u003e\u003cstrong data-start=\"3495\" data-end=\"3537\"\u003eQ: Does it support HART communication?\u003c\/strong\u003e\u003cbr data-start=\"3537\" data-end=\"3540\"\u003eA: Yes, it supports HART and other industrial communication protocols.\u003c\/p\u003e\n\u003cp data-start=\"3612\" data-end=\"3727\"\u003e\u003cstrong data-start=\"3612\" data-end=\"3658\"\u003eQ: Is it suitable for safety applications?\u003c\/strong\u003e\u003cbr data-start=\"3658\" data-end=\"3661\"\u003eA: Yes, it is certified for SIL2\/SIL3 safety instrumented systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43318877388861,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/ejx120a-differential-pressure-transmitter-product-view.png?v=1783064713"},{"product_id":"yokogawa-ejx310a-absolute-pressure-transmitter","title":"Yokogawa EJX310A Absolute Pressure Transmitter","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"707\" data-start=\"671\" data-section-id=\"1vevt5w\"\u003eProduct Description\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-end=\"902\" data-start=\"709\"\u003eThe \u003cstrong data-end=\"763\" data-start=\"713\"\u003eYokogawa EJX310A Absolute Pressure Transmitter\u003c\/strong\u003e is a high-performance industrial pressure measurement device designed for continuous monitoring of gases, liquids, and steam applications.\u003c\/p\u003e\n\u003cp data-end=\"1299\" data-start=\"904\"\u003eBuilt with Yokogawa's advanced \u003cstrong data-end=\"980\" data-start=\"935\"\u003eDPharp digital resonant sensor technology\u003c\/strong\u003e, the EJX310A provides excellent long-term stability, fast response time, and high measurement accuracy. The transmitter is commonly used in chemical processing plants, oil and gas facilities, power generation systems, and industrial automation applications where reliable \u003cstrong data-end=\"1286\" data-start=\"1253\"\u003eabsolute pressure measurement\u003c\/strong\u003e is critical.\u003c\/p\u003e\n\u003cp data-end=\"1441\" data-start=\"1301\"\u003eIts rugged construction and intelligent diagnostics help reduce maintenance costs while improving process safety and operational efficiency.\u003c\/p\u003e\n\u003cp data-end=\"1625\" data-start=\"1443\"\u003eNatural SEO keywords included: \u003cstrong data-end=\"1507\" data-start=\"1474\"\u003eabsolute pressure transmitter\u003c\/strong\u003e, \u003cstrong data-end=\"1533\" data-start=\"1509\"\u003epressure transmitter\u003c\/strong\u003e, \u003cstrong data-end=\"1565\" data-start=\"1535\"\u003eindustrial pressure sensor\u003c\/strong\u003e, \u003cstrong data-end=\"1600\" data-start=\"1567\"\u003eYokogawa pressure transmitter\u003c\/strong\u003e, \u003cstrong data-end=\"1624\" data-start=\"1602\"\u003eDPharp transmitter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-end=\"1630\" data-start=\"1627\"\u003e\n\u003ch1 data-end=\"1648\" data-start=\"1632\" data-section-id=\"1vrrhye\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-end=\"2086\" data-start=\"1650\"\u003e• DPharp digital sensor technology\u003cbr data-end=\"1687\" data-start=\"1684\"\u003e• Accuracy up to ±0.04–0.075% of span\u003cbr data-end=\"1727\" data-start=\"1724\"\u003e• Response time as fast as 90 ms\u003cbr data-end=\"1762\" data-start=\"1759\"\u003e• Long-term stability up to ±0.2% per 10–15 years\u003cbr data-end=\"1814\" data-start=\"1811\"\u003e• Supports liquid, gas, and steam applications\u003cbr data-end=\"1863\" data-start=\"1860\"\u003e• HART \/ FOUNDATION Fieldbus \/ PROFIBUS PA options\u003cbr data-end=\"1916\" data-start=\"1913\"\u003e• Advanced self-diagnostic functions\u003cbr data-end=\"1955\" data-start=\"1952\"\u003e• SIL2 \/ SIL3 safety certification\u003cbr data-end=\"1992\" data-start=\"1989\"\u003e• Rugged industrial construction for harsh environments \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"2091\" data-start=\"2088\"\u003e\n\u003ch1 data-end=\"2119\" data-start=\"2093\" data-section-id=\"l5ozhv\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-end=\"2372\" data-start=\"2121\"\u003e\n\u003cli data-end=\"2155\" data-start=\"2121\" data-section-id=\"eg6nxd\"\u003eOil and gas processing systems\u003c\/li\u003e\n\u003cli data-end=\"2183\" data-start=\"2156\" data-section-id=\"q1alyr\"\u003eChemical process plants\u003c\/li\u003e\n\u003cli data-end=\"2212\" data-start=\"2184\" data-section-id=\"1x31490\"\u003eSteam and boiler systems\u003c\/li\u003e\n\u003cli data-end=\"2244\" data-start=\"2213\" data-section-id=\"1jhjfua\"\u003ePower generation facilities\u003c\/li\u003e\n\u003cli data-end=\"2278\" data-start=\"2245\" data-section-id=\"xwcxty\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli data-end=\"2310\" data-start=\"2279\" data-section-id=\"1yqxz07\"\u003ePressure monitoring systems\u003c\/li\u003e\n\u003cli data-end=\"2343\" data-start=\"2311\" data-section-id=\"ab88nh\"\u003eProcess control applications\u003c\/li\u003e\n\u003cli data-end=\"2372\" data-start=\"2344\" data-section-id=\"rk091t\"\u003eTank pressure monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2377\" data-start=\"2374\"\u003e\n\u003ch1 data-end=\"2412\" data-start=\"2379\" data-section-id=\"6p5k8g\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-end=\"2448\" data-start=\"2414\"\u003eBefore selecting EJX310A, confirm:\u003c\/p\u003e\n\u003cul data-end=\"2749\" data-start=\"2450\"\u003e\n\u003cli data-end=\"2494\" data-start=\"2450\" data-section-id=\"1fep4tx\"\u003eRequired pressure range and capsule type\u003c\/li\u003e\n\u003cli data-end=\"2534\" data-start=\"2495\" data-section-id=\"1kubua0\"\u003eProcess medium (liquid, gas, steam)\u003c\/li\u003e\n\u003cli data-end=\"2566\" data-start=\"2535\" data-section-id=\"vo2y1y\"\u003eProcess pressure conditions\u003c\/li\u003e\n\u003cli data-end=\"2610\" data-start=\"2567\" data-section-id=\"knp034\"\u003eMounting requirements and manifold type\u003c\/li\u003e\n\u003cli data-end=\"2657\" data-start=\"2611\" data-section-id=\"59mkdc\"\u003eOutput protocol (4–20mA \/ HART \/ Fieldbus)\u003c\/li\u003e\n\u003cli data-end=\"2703\" data-start=\"2658\" data-section-id=\"3is4jq\"\u003eHazardous area certification requirements\u003c\/li\u003e\n\u003cli data-end=\"2749\" data-start=\"2704\" data-section-id=\"wne047\"\u003eRequired response time and accuracy level\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2754\" data-start=\"2751\"\u003e\n\u003ch1 data-end=\"2770\" data-start=\"2756\" data-section-id=\"a0z7dm\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-end=\"2937\" data-start=\"2772\"\u003e\u003cstrong data-end=\"2813\" data-start=\"2772\"\u003eQ: What is Yokogawa EJX310A used for?\u003c\/strong\u003e\u003cbr data-end=\"2816\" data-start=\"2813\"\u003eA: It is used for absolute pressure measurement in industrial process applications. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3089\" data-start=\"2939\"\u003e\u003cstrong data-end=\"2986\" data-start=\"2939\"\u003eQ: What sensor technology does EJX310A use?\u003c\/strong\u003e\u003cbr data-end=\"2989\" data-start=\"2986\"\u003eA: It uses Yokogawa DPharp digital resonant sensor technology. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3237\" data-start=\"3091\"\u003e\u003cstrong data-end=\"3130\" data-start=\"3091\"\u003eQ: What is the accuracy of EJX310A?\u003c\/strong\u003e\u003cbr data-end=\"3133\" data-start=\"3130\"\u003eA: Accuracy can reach ±0.04–0.075% depending on capsule selection. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3402\" data-start=\"3239\"\u003e\u003cstrong data-end=\"3286\" data-start=\"3239\"\u003eQ: Does EJX310A support HART communication?\u003c\/strong\u003e\u003cbr data-end=\"3289\" data-start=\"3286\"\u003eA: Yes. HART and multiple industrial communication protocols are available. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3547\" data-start=\"3404\"\u003e\u003cstrong data-end=\"3449\" data-start=\"3404\"\u003eQ: Can EJX310A be used in safety systems?\u003c\/strong\u003e\u003cbr data-end=\"3452\" data-start=\"3449\"\u003eA: Yes. SIL2\/SIL3 certification is available as standard. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3834\" data-start=\"3549\"\u003e\u003cstrong data-end=\"3620\" data-start=\"3549\"\u003eQ: Is Yokogawa pressure technology considered reliable in industry?\u003c\/strong\u003e\u003cbr data-end=\"3623\" data-start=\"3620\"\u003eA: Instrumentation professionals frequently describe Yokogawa pressure transmitters as highly stable and widely used in process industries, particularly the DPharp platform.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43325695000637,"sku":null,"price":1400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/ejx310a-absolute-pressure-transmitter-reference-product.png?v=1783305358"},{"product_id":"yokogawa-ejx310e-absolute-pressure-transmitter","title":"Yokogawa EJX310E Absolute Pressure Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"591\" data-end=\"627\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"629\" data-end=\"811\"\u003eThe \u003cstrong data-start=\"633\" data-end=\"683\"\u003eYokogawa EJX310E Absolute Pressure Transmitter\u003c\/strong\u003e is a high-performance field instrument designed for precise absolute pressure measurement in demanding industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"813\" data-end=\"1173\"\u003eIt utilizes Yokogawa’s advanced \u003cstrong data-start=\"845\" data-end=\"890\"\u003eDPharp digital resonant sensor technology\u003c\/strong\u003e, ensuring exceptional measurement stability, fast response, and long-term reliability. The EJX310E is widely used in oil \u0026amp; gas, chemical processing, power generation, and other process industries where accurate \u003cstrong data-start=\"1102\" data-end=\"1134\"\u003eabsolute pressure monitoring\u003c\/strong\u003e is critical for safety and efficiency.\u003c\/p\u003e\n\u003cp data-start=\"1175\" data-end=\"1327\"\u003eWith robust construction and intelligent diagnostics, the EJX310E helps reduce maintenance downtime while improving overall process control performance.\u003c\/p\u003e\n\u003cp data-start=\"1329\" data-end=\"1519\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1360\" data-end=\"1393\"\u003eabsolute pressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1395\" data-end=\"1428\"\u003eYokogawa pressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1430\" data-end=\"1460\"\u003eindustrial pressure sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1462\" data-end=\"1484\"\u003eDPharp transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1486\" data-end=\"1518\"\u003eprocess pressure measurement\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1521\" data-end=\"1524\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1526\" data-end=\"1542\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1544\" data-end=\"2013\"\u003e• Advanced DPharp digital resonant sensor technology\u003cbr data-start=\"1596\" data-end=\"1599\"\u003e• High accuracy up to ±0.04–0.075% of span\u003cbr data-start=\"1641\" data-end=\"1644\"\u003e• Fast response time for dynamic process conditions\u003cbr data-start=\"1695\" data-end=\"1698\"\u003e• Long-term stability for reduced recalibration needs\u003cbr data-start=\"1751\" data-end=\"1754\"\u003e• Suitable for gas, liquid, and steam applications\u003cbr data-start=\"1804\" data-end=\"1807\"\u003e• HART \/ FOUNDATION Fieldbus \/ PROFIBUS PA support\u003cbr data-start=\"1857\" data-end=\"1860\"\u003e• Built-in self-diagnostics for predictive maintenance\u003cbr data-start=\"1914\" data-end=\"1917\"\u003e• SIL2 \/ SIL3 safety certification options\u003cbr data-start=\"1959\" data-end=\"1962\"\u003e• Rugged design for harsh industrial environments\u003c\/p\u003e\n\u003chr data-start=\"2015\" data-end=\"2018\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"2020\" data-end=\"2046\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2048\" data-end=\"2350\"\u003e\n\u003cli data-section-id=\"9syr4f\" data-start=\"2048\" data-end=\"2085\"\u003eOil \u0026amp; gas production and refining\u003c\/li\u003e\n\u003cli data-section-id=\"8vm30r\" data-start=\"2086\" data-end=\"2123\"\u003eChemical and petrochemical plants\u003c\/li\u003e\n\u003cli data-section-id=\"1sm2t9j\" data-start=\"2124\" data-end=\"2152\"\u003ePower generation systems\u003c\/li\u003e\n\u003cli data-section-id=\"du75dn\" data-start=\"2153\" data-end=\"2193\"\u003eBoiler and steam pressure monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"xwcxty\" data-start=\"2194\" data-end=\"2227\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli data-section-id=\"18zzdpi\" data-start=\"2228\" data-end=\"2268\"\u003eTank and vessel pressure measurement\u003c\/li\u003e\n\u003cli data-section-id=\"v87o5h\" data-start=\"2269\" data-end=\"2307\"\u003eProcess control and safety systems\u003c\/li\u003e\n\u003cli data-section-id=\"77ljm8\" data-start=\"2308\" data-end=\"2350\"\u003eGeneral industrial pressure monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2352\" data-end=\"2355\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2357\" data-end=\"2390\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2392\" data-end=\"2426\"\u003eBefore selecting EJX310E, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2428\" data-end=\"2758\"\u003e\n\u003cli data-section-id=\"18dq38i\" data-start=\"2428\" data-end=\"2476\"\u003eRequired pressure range and measurement type\u003c\/li\u003e\n\u003cli data-section-id=\"1ri3mzs\" data-start=\"2477\" data-end=\"2518\"\u003eProcess medium (gas \/ liquid \/ steam)\u003c\/li\u003e\n\u003cli data-section-id=\"mb9wt9\" data-start=\"2519\" data-end=\"2568\"\u003eInstallation type and connection requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1jlmr1s\" data-start=\"2569\" data-end=\"2618\"\u003eOutput signal type (4–20mA \/ HART \/ Fieldbus)\u003c\/li\u003e\n\u003cli data-section-id=\"3is4jq\" data-start=\"2619\" data-end=\"2664\"\u003eHazardous area certification requirements\u003c\/li\u003e\n\u003cli data-section-id=\"10myop8\" data-start=\"2665\" data-end=\"2711\"\u003eRequired accuracy and response performance\u003c\/li\u003e\n\u003cli data-section-id=\"10d7sof\" data-start=\"2712\" data-end=\"2758\"\u003eSystem compatibility and integration needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2760\" data-end=\"2763\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2765\" data-end=\"2779\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2781\" data-end=\"2917\"\u003e\u003cstrong data-start=\"2781\" data-end=\"2822\"\u003eQ: What is Yokogawa EJX310E used for?\u003c\/strong\u003e\u003cbr data-start=\"2822\" data-end=\"2825\"\u003eA: It is used for accurate absolute pressure measurement in industrial process applications.\u003c\/p\u003e\n\u003cp data-start=\"2919\" data-end=\"3058\"\u003e\u003cstrong data-start=\"2919\" data-end=\"2959\"\u003eQ: What technology does EJX310E use?\u003c\/strong\u003e\u003cbr data-start=\"2959\" data-end=\"2962\"\u003eA: It uses Yokogawa’s DPharp digital resonant sensor technology for high stability and accuracy.\u003c\/p\u003e\n\u003cp data-start=\"3060\" data-end=\"3194\"\u003e\u003cstrong data-start=\"3060\" data-end=\"3095\"\u003eQ: What industries use EJX310E?\u003c\/strong\u003e\u003cbr data-start=\"3095\" data-end=\"3098\"\u003eA: It is widely used in oil \u0026amp; gas, chemical plants, power generation, and industrial automation.\u003c\/p\u003e\n\u003cp data-start=\"3196\" data-end=\"3316\"\u003e\u003cstrong data-start=\"3196\" data-end=\"3243\"\u003eQ: Does EJX310E support HART communication?\u003c\/strong\u003e\u003cbr data-start=\"3243\" data-end=\"3246\"\u003eA: Yes, it supports HART and other industrial communication protocols.\u003c\/p\u003e\n\u003cp data-start=\"3318\" data-end=\"3448\"\u003e\u003cstrong data-start=\"3318\" data-end=\"3364\"\u003eQ: Is EJX310E suitable for safety systems?\u003c\/strong\u003e\u003cbr data-start=\"3364\" data-end=\"3367\"\u003eA: Yes, SIL2\/SIL3 certification options are available depending on configuration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43325698375741,"sku":null,"price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/ejx310e-absolute-pressure-transmitter-product-view.png?v=1783305979"},{"product_id":"yokogawa-yta610-essential-temperature-transmitter","title":"Yokogawa YTA610 Essential Temperature Transmitter","description":"\u003cp data-start=\"256\" data-end=\"624\"\u003eThe Yokogawa YTA610 Essential Temperature Transmitter is a reliable field temperature transmitter designed for stable and accurate temperature measurement in industrial process environments. It supports common temperature sensors such as RTDs and thermocouples and provides standard 4–20 mA or digital communication outputs for integration with modern control systems.\u003c\/p\u003e\n\u003cp data-start=\"626\" data-end=\"852\"\u003eTypical Applications:\u003cbr data-start=\"647\" data-end=\"650\"\u003e• Process industry temperature monitoring\u003cbr data-start=\"691\" data-end=\"694\"\u003e• Chemical and petrochemical plants\u003cbr data-start=\"729\" data-end=\"732\"\u003e• Power generation and energy facilities\u003cbr data-start=\"772\" data-end=\"775\"\u003e• Oil \u0026amp; gas processing systems\u003cbr data-start=\"805\" data-end=\"808\"\u003e• General industrial temperature measurement\u003c\/p\u003e\n\u003cp data-start=\"854\" data-end=\"1001\"\u003eNot Recommended For:\u003cbr data-start=\"874\" data-end=\"877\"\u003e• Simple local temperature indication without transmitter output\u003cbr data-start=\"941\" data-end=\"944\"\u003e• Ultra-high-accuracy laboratory calibration applications\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/GS01C50C01-00EN.pdf?_gl=1*1t8lu8t*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003e General Specifications - YTA50 Temperature Transmitter \u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"1165\" data-end=\"1183\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1185\" data-end=\"1559\"\u003e• Confirm sensor type — supports common RTDs (Pt100 etc.) and thermocouples.\u003cbr data-start=\"1261\" data-end=\"1264\"\u003e• Determine installation style — available for field mount or DIN rail installation depending on configuration.\u003cbr data-start=\"1375\" data-end=\"1378\"\u003e• Select communication protocol — standard 4–20 mA with optional digital communication such as HART.\u003cbr data-start=\"1478\" data-end=\"1481\"\u003e• Verify housing and environmental protection level for your plant conditions.\u003c\/p\u003e\n\u003ch2 data-start=\"1593\" data-end=\"1650\"\u003eWhy Choose the Yokogawa YTA610 Temperature Transmitter\u003c\/h2\u003e\n\u003cp data-start=\"1652\" data-end=\"1775\"\u003e• Stable Industrial Performance\u003cbr data-start=\"1687\" data-end=\"1690\"\u003eEngineered for reliable temperature measurement in demanding industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"1777\" data-end=\"1898\"\u003e• Wide Sensor Compatibility\u003cbr data-start=\"1808\" data-end=\"1811\"\u003eSupports multiple RTD and thermocouple input types for flexible instrumentation design.\u003c\/p\u003e\n\u003cp data-start=\"1900\" data-end=\"2033\"\u003e• Standard Industrial Outputs\u003cbr data-start=\"1933\" data-end=\"1936\"\u003e4–20 mA analog output with optional HART communication for easy integration with control systems.\u003c\/p\u003e\n\u003cp data-start=\"2035\" data-end=\"2172\"\u003e• Proven Yokogawa Reliability\u003cbr data-start=\"2068\" data-end=\"2071\"\u003eDesigned using Yokogawa’s long-established expertise in industrial instrumentation and field devices.\u003c\/p\u003e\n\u003cp data-start=\"2174\" data-end=\"2302\"\u003e• Flexible Installation Options\u003cbr data-start=\"2209\" data-end=\"2212\"\u003eCompact transmitter design allows easy installation in field housings or control cabinets.\u003c\/p\u003e\n\u003ch2 data-start=\"2339\" data-end=\"2345\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2347\" data-end=\"2502\"\u003eQ: What sensors can the YTA610 accept?\u003cbr data-start=\"2389\" data-end=\"2392\"\u003eA: It supports a wide range of temperature sensors including RTDs such as Pt100 and common thermocouple types.\u003c\/p\u003e\n\u003cp data-start=\"2504\" data-end=\"2649\"\u003eQ: What output signals are available?\u003cbr data-start=\"2545\" data-end=\"2548\"\u003eA: The transmitter typically provides 4–20 mA analog output with optional HART digital communication.\u003c\/p\u003e\n\u003cp data-start=\"2651\" data-end=\"2848\"\u003eQ: Is the YTA610 suitable for harsh industrial environments?\u003cbr data-start=\"2715\" data-end=\"2718\"\u003eA: Yes — it is designed for stable operation in industrial plants with strong resistance to vibration and electrical interference.\u003c\/p\u003e\n\u003cp data-start=\"2850\" data-end=\"3036\"\u003eQ: Can this transmitter be integrated into existing PLC or DCS systems?\u003cbr data-start=\"2925\" data-end=\"2928\"\u003eA: Yes — the standard 4–20 mA signal and HART protocol allow seamless integration with most control systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43329368195133,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-yta610-temperature-transmitter.webp?v=1783478365"},{"product_id":"yokogawa-yta70-temperature-transmitter","title":"Yokogawa YTA70 Temperature Transmitter","description":"\u003cp data-start=\"219\" data-end=\"556\"\u003eThe Yokogawa YTA70 is a smart temperature transmitter designed for precise and reliable temperature measurement in demanding industrial environments. It supports a wide range of RTD and thermocouple sensors and provides 4–20 mA output with digital communication options, enabling seamless integration into modern process control systems.\u003c\/p\u003e\n\u003cp data-start=\"558\" data-end=\"776\"\u003eTypical Applications:\u003cbr data-start=\"579\" data-end=\"582\"\u003e• Oil \u0026amp; gas processing plants\u003cbr data-start=\"611\" data-end=\"614\"\u003e• Petrochemical and chemical industries\u003cbr data-start=\"653\" data-end=\"656\"\u003e• Power generation facilities\u003cbr data-start=\"685\" data-end=\"688\"\u003e• Refining and pipeline temperature monitoring\u003cbr data-start=\"734\" data-end=\"737\"\u003e• Industrial process automation systems\u003c\/p\u003e\n\u003cp data-start=\"778\" data-end=\"941\"\u003eNot Recommended For:\u003cbr data-start=\"798\" data-end=\"801\"\u003e• Simple local temperature indication without transmitter output\u003cbr data-start=\"865\" data-end=\"868\"\u003e• Basic low-cost OEM equipment where advanced diagnostics are unnecessary\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/2\/8551\/files\/GS01C50G01-01EN_036.pdf?_gl=1*1p2xrnd*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003eYTA70 Temperature Transmitter\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"1082\" data-end=\"1100\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1102\" data-end=\"1485\"\u003e• Confirm sensor type — supports RTDs such as Pt100 and common thermocouple types.\u003cbr data-start=\"1184\" data-end=\"1187\"\u003e• Determine mounting configuration — typically installed in field instrument housings or control cabinets.\u003cbr data-start=\"1293\" data-end=\"1296\"\u003e• Select communication protocol — available with standard 4–20 mA output and digital communication options.\u003cbr data-start=\"1403\" data-end=\"1406\"\u003e• Verify environmental protection and hazardous area certification if required.\u003c\/p\u003e\n\u003ch2 data-start=\"1519\" data-end=\"1575\"\u003eWhy Choose the Yokogawa YTA70 Temperature Transmitter\u003c\/h2\u003e\n\u003cp data-start=\"1577\" data-end=\"1699\"\u003e• High Measurement Stability\u003cbr data-start=\"1609\" data-end=\"1612\"\u003eProvides accurate and stable temperature measurement for critical industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"1701\" data-end=\"1816\"\u003e• Wide Sensor Compatibility\u003cbr data-start=\"1732\" data-end=\"1735\"\u003eSupports various RTD and thermocouple inputs for flexible instrumentation setups.\u003c\/p\u003e\n\u003cp data-start=\"1818\" data-end=\"1958\"\u003e• Advanced Communication Capability\u003cbr data-start=\"1857\" data-end=\"1860\"\u003eOffers 4–20 mA output with digital communication support for integration with PLC and DCS systems.\u003c\/p\u003e\n\u003cp data-start=\"1960\" data-end=\"2100\"\u003e• Industrial-Grade Reliability\u003cbr data-start=\"1994\" data-end=\"1997\"\u003eDesigned for continuous operation in harsh environments including vibration and temperature variations.\u003c\/p\u003e\n\u003cp data-start=\"2102\" data-end=\"2230\"\u003e• Flexible System Integration\u003cbr data-start=\"2135\" data-end=\"2138\"\u003eEasily integrated into existing process control systems used in large industrial facilities.\u003c\/p\u003e\n\u003ch2 data-start=\"2267\" data-end=\"2273\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2275\" data-end=\"2451\"\u003eQ: What types of sensors can the YTA70 work with?\u003cbr data-start=\"2328\" data-end=\"2331\"\u003eA: It supports a wide range of RTD sensors (such as Pt100) and thermocouples used in industrial temperature measurement.\u003c\/p\u003e\n\u003cp data-start=\"2453\" data-end=\"2624\"\u003eQ: What output signals are available?\u003cbr data-start=\"2494\" data-end=\"2497\"\u003eA: The transmitter typically provides a 4–20 mA analog signal with digital communication capability depending on configuration.\u003c\/p\u003e\n\u003cp data-start=\"2626\" data-end=\"2784\"\u003eQ: Is the YTA70 suitable for process industries?\u003cbr data-start=\"2678\" data-end=\"2681\"\u003eA: Yes — it is widely used in oil \u0026amp; gas, petrochemical, power generation, and other process industries.\u003c\/p\u003e\n\u003cp data-start=\"2786\" data-end=\"2942\"\u003eQ: Can it be integrated into PLC or DCS systems?\u003cbr data-start=\"2838\" data-end=\"2841\"\u003eA: Yes — the standard industrial output and communication protocols make integration straightforward.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43329369669693,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-yta70-temperature-transmitter.webp?v=1783478603"},{"product_id":"yokogawa-yta710-ultimate-temperature-transmitter","title":"Yokogawa YTA710 Ultimate Temperature Transmitter","description":"\u003cp data-start=\"287\" data-end=\"712\"\u003eThe \u003cstrong data-start=\"291\" data-end=\"343\"\u003eYokogawa YTA710 Ultimate Temperature Transmitter\u003c\/strong\u003e is a high-performance field-mount temperature transmitter designed for precise and stable temperature measurement in demanding industrial environments. With advanced digital signal processing, dual-sensor capability and support for HART® communication, the YTA710 ensures reliable temperature monitoring and seamless integration into modern process automation systems.\u003c\/p\u003e\n\u003cp data-start=\"714\" data-end=\"919\"\u003eTypical Applications:\u003cbr data-start=\"735\" data-end=\"738\"\u003e• Oil \u0026amp; gas processing facilities\u003cbr data-start=\"771\" data-end=\"774\"\u003e• Chemical and petrochemical plants\u003cbr data-start=\"809\" data-end=\"812\"\u003e• Power generation and utilities\u003cbr data-start=\"844\" data-end=\"847\"\u003e• Industrial process automation\u003cbr data-start=\"878\" data-end=\"881\"\u003e• General plant temperature monitoring\u003c\/p\u003e\n\u003cp data-start=\"921\" data-end=\"1077\"\u003eNot Recommended For:\u003cbr data-start=\"941\" data-end=\"944\"\u003e• Simple local temperature indication without signal output\u003cbr data-start=\"1003\" data-end=\"1006\"\u003e• Low-cost OEM equipment where a basic temperature sensor is sufficient\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/2\/8551\/files\/GS01C50G01-01EN_036.pdf?_gl=1*1p2xrnd*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003e General Specifications - YTA710 Temperature Transmitter\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1350\" data-end=\"1368\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1370\" data-end=\"1784\"\u003e• Confirm the \u003cstrong data-start=\"1384\" data-end=\"1399\"\u003esensor type\u003c\/strong\u003e required (RTD or thermocouple).\u003cbr data-start=\"1431\" data-end=\"1434\"\u003e• Verify the suitable \u003cstrong data-start=\"1456\" data-end=\"1477\"\u003etemperature range\u003c\/strong\u003e for the process application.\u003cbr data-start=\"1506\" data-end=\"1509\"\u003e• Select the required \u003cstrong data-start=\"1531\" data-end=\"1548\"\u003eoutput signal\u003c\/strong\u003e, typically 4–20 mA with HART® communication.\u003cbr data-start=\"1593\" data-end=\"1596\"\u003e• Ensure compatibility with the required \u003cstrong data-start=\"1637\" data-end=\"1654\"\u003emounting type\u003c\/strong\u003e (field mount or head mount).\u003cbr data-start=\"1683\" data-end=\"1686\"\u003e• Consider environmental conditions such as \u003cstrong data-start=\"1730\" data-end=\"1783\"\u003ehazardous-area approvals and enclosure protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"5pjzc3\" data-start=\"1818\" data-end=\"1884\"\u003eWhy Choose the Yokogawa YTA710 Ultimate Temperature Transmitter\u003c\/h2\u003e\n\u003cp data-start=\"1886\" data-end=\"2081\"\u003e• \u003cstrong data-start=\"1888\" data-end=\"1931\"\u003eHigh Measurement Accuracy and Stability\u003c\/strong\u003e\u003cbr data-start=\"1931\" data-end=\"1934\"\u003eAdvanced signal processing technology ensures reliable temperature measurement with excellent long-term stability in critical process applications.\u003c\/p\u003e\n\u003cp data-start=\"2083\" data-end=\"2256\"\u003e• \u003cstrong data-start=\"2085\" data-end=\"2111\"\u003eDual-Sensor Capability\u003c\/strong\u003e\u003cbr data-start=\"2111\" data-end=\"2114\"\u003eThe transmitter can support \u003cstrong data-start=\"2142\" data-end=\"2177\"\u003edual RTD or thermocouple inputs\u003c\/strong\u003e, enabling sensor redundancy or temperature averaging for improved reliability.\u003c\/p\u003e\n\u003cp data-start=\"2258\" data-end=\"2434\"\u003e• \u003cstrong data-start=\"2260\" data-end=\"2291\"\u003eHART® Digital Communication\u003c\/strong\u003e\u003cbr data-start=\"2291\" data-end=\"2294\"\u003eStandard \u003cstrong data-start=\"2303\" data-end=\"2340\"\u003e4-20 mA output with HART protocol\u003c\/strong\u003e allows easy integration into distributed control systems (DCS) and plant automation networks.\u003c\/p\u003e\n\u003cp data-start=\"2436\" data-end=\"2610\"\u003e• \u003cstrong data-start=\"2438\" data-end=\"2471\"\u003eFlexible Sensor Compatibility\u003c\/strong\u003e\u003cbr data-start=\"2471\" data-end=\"2474\"\u003eSupports a wide range of \u003cstrong data-start=\"2499\" data-end=\"2536\"\u003eRTD and thermocouple sensor types\u003c\/strong\u003e, making it suitable for diverse industrial temperature measurement tasks.\u003c\/p\u003e\n\u003cp data-start=\"2612\" data-end=\"2784\"\u003e• \u003cstrong data-start=\"2614\" data-end=\"2642\"\u003eRobust Industrial Design\u003c\/strong\u003e\u003cbr data-start=\"2642\" data-end=\"2645\"\u003eEngineered for harsh environments, the YTA710 features a durable enclosure designed for reliable operation in demanding process industries.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2821\" data-end=\"2827\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2829\" data-end=\"3018\"\u003e\u003cstrong data-start=\"2829\" data-end=\"2892\"\u003eQ: What sensors are compatible with the YTA710 transmitter?\u003c\/strong\u003e\u003cbr data-start=\"2892\" data-end=\"2895\"\u003eA: The transmitter supports multiple RTD and thermocouple sensor types commonly used in industrial temperature measurement.\u003c\/p\u003e\n\u003cp data-start=\"3020\" data-end=\"3216\"\u003e\u003cstrong data-start=\"3020\" data-end=\"3073\"\u003eQ: Does the YTA710 support digital communication?\u003c\/strong\u003e\u003cbr data-start=\"3073\" data-end=\"3076\"\u003eA: Yes. It provides a standard \u003cstrong data-start=\"3107\" data-end=\"3157\"\u003e4–20 mA analog signal with HART® communication\u003c\/strong\u003e, allowing integration with modern process control systems.\u003c\/p\u003e\n\u003cp data-start=\"3218\" data-end=\"3429\"\u003e\u003cstrong data-start=\"3218\" data-end=\"3281\"\u003eQ: Can the YTA710 operate in harsh industrial environments?\u003c\/strong\u003e\u003cbr data-start=\"3281\" data-end=\"3284\"\u003eA: Yes. The transmitter is designed with a rugged enclosure suitable for demanding industrial environments such as oil \u0026amp; gas and chemical plants.\u003c\/p\u003e\n\u003cp data-start=\"3431\" data-end=\"3632\"\u003e\u003cstrong data-start=\"3431\" data-end=\"3502\"\u003eQ: What industries commonly use the YTA710 temperature transmitter?\u003c\/strong\u003e\u003cbr data-start=\"3502\" data-end=\"3505\"\u003eA: It is widely used in oil \u0026amp; gas processing, petrochemical plants, power generation and general industrial automation systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43329372061757,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-yta710-temperature-transmitter.webp?v=1783478805"},{"product_id":"yokogawa-yta610-essential-temperature-transmitter-1","title":"Yokogawa  YTA610 Essential Temperature Transmitter","description":"\u003cp data-start=\"275\" data-end=\"716\"\u003eThe \u003cstrong data-start=\"279\" data-end=\"320\"\u003eYokogawa EJA115E Low Flow Transmitter\u003c\/strong\u003e is a differential pressure transmitter designed specifically for accurate measurement of very low flow rates in industrial processes. It combines an integral flow orifice with Yokogawa’s advanced DPharp digital sensor to deliver stable and reliable flow measurement. In addition, the transmitter supports multiple digital communication protocols for easy integration into modern control systems.\u003c\/p\u003e\n\u003cp data-start=\"718\" data-end=\"970\"\u003eTypical Applications:\u003cbr data-start=\"739\" data-end=\"742\"\u003e• Low flow measurement in chemical processing\u003cbr data-start=\"787\" data-end=\"790\"\u003e• Gas flow monitoring in pipelines\u003cbr data-start=\"824\" data-end=\"827\"\u003e• Pilot plants and laboratory process systems\u003cbr data-start=\"872\" data-end=\"875\"\u003e• Utility flow monitoring in industrial facilities\u003cbr data-start=\"925\" data-end=\"928\"\u003e• Process optimization and control systems\u003c\/p\u003e\n\u003cp data-start=\"972\" data-end=\"1133\"\u003eNot Recommended For:\u003cbr data-start=\"992\" data-end=\"995\"\u003e• Applications requiring standard high-flow measurement\u003cbr data-start=\"1050\" data-end=\"1053\"\u003e• Installations where a dedicated flow meter is already used for large pipelines\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/GS01C31K01-01EN.pdf?_gl=1*8tbirb*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003e EJA115E Low Flow Transmitter\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1374\" data-end=\"1392\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1394\" data-end=\"1853\"\u003e• Confirm the expected \u003cstrong data-start=\"1417\" data-end=\"1431\"\u003eflow range\u003c\/strong\u003e to ensure the transmitter is suitable for low-flow measurement.\u003cbr data-start=\"1495\" data-end=\"1498\"\u003e• Select the appropriate \u003cstrong data-start=\"1523\" data-end=\"1544\"\u003eorifice bore size\u003c\/strong\u003e based on process conditions and pipe dimensions.\u003cbr data-start=\"1593\" data-end=\"1596\"\u003e• Choose the required \u003cstrong data-start=\"1618\" data-end=\"1635\"\u003eoutput signal\u003c\/strong\u003e, such as 4–20 mA with HART® communication.\u003cbr data-start=\"1678\" data-end=\"1681\"\u003e• Verify compatibility with the plant \u003cstrong data-start=\"1719\" data-end=\"1754\"\u003econtrol system or flow computer\u003c\/strong\u003e.\u003cbr data-start=\"1755\" data-end=\"1758\"\u003e• In addition, confirm that pressure ratings and certifications meet installation requirements.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1evb89g\" data-start=\"1887\" data-end=\"1942\"\u003eWhy Choose the Yokogawa EJA115E Low Flow Transmitter\u003c\/h2\u003e\n\u003cp data-start=\"1944\" data-end=\"2199\"\u003e• \u003cstrong data-start=\"1946\" data-end=\"1984\"\u003eOptimized for Low Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"1984\" data-end=\"1987\"\u003eThe EJA115E integrates an \u003cstrong data-start=\"2013\" data-end=\"2044\"\u003eintegral flow orifice (IFO)\u003c\/strong\u003e with a differential pressure transmitter. This design improves measurement accuracy in very low flow applications.\u003c\/p\u003e\n\u003cp data-start=\"2201\" data-end=\"2423\"\u003e• \u003cstrong data-start=\"2203\" data-end=\"2232\"\u003eHigh Measurement Accuracy\u003c\/strong\u003e\u003cbr data-start=\"2232\" data-end=\"2235\"\u003eThe transmitter offers approximately \u003cstrong data-start=\"2272\" data-end=\"2311\"\u003e±0.055% square-root output accuracy\u003c\/strong\u003e, ensuring reliable flow measurement for demanding industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"2425\" data-end=\"2673\"\u003e• \u003cstrong data-start=\"2427\" data-end=\"2461\"\u003eAdvanced DPharp Digital Sensor\u003c\/strong\u003e\u003cbr data-start=\"2461\" data-end=\"2464\"\u003eYokogawa’s DPharp sensor technology delivers excellent stability and repeatability. As a result, the transmitter maintains accurate readings over long operating periods.\u003c\/p\u003e\n\u003cp data-start=\"2675\" data-end=\"2920\"\u003e• \u003cstrong data-start=\"2677\" data-end=\"2718\"\u003eFast Response and Long-Term Stability\u003c\/strong\u003e\u003cbr data-start=\"2718\" data-end=\"2721\"\u003eWith response times as low as \u003cstrong data-start=\"2751\" data-end=\"2760\"\u003e90 ms\u003c\/strong\u003e and stability of about \u003cstrong data-start=\"2784\" data-end=\"2806\"\u003e±0.1% per 10 years\u003c\/strong\u003e, the transmitter supports reliable long-term operation in process plants.\u003c\/p\u003e\n\u003cp data-start=\"2922\" data-end=\"3118\"\u003e• \u003cstrong data-start=\"2924\" data-end=\"2958\"\u003eMultiple Communication Options\u003c\/strong\u003e\u003cbr data-start=\"2958\" data-end=\"2961\"\u003eThe device supports \u003cstrong data-start=\"2981\" data-end=\"3044\"\u003eHART®, FOUNDATION Fieldbus, PROFIBUS PA and BRAIN protocols\u003c\/strong\u003e. Therefore, it integrates easily with modern distributed control systems.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"3155\" data-end=\"3161\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"3163\" data-end=\"3381\"\u003e\u003cstrong data-start=\"3163\" data-end=\"3227\"\u003eQ: What makes the EJA115E suitable for low flow measurement?\u003c\/strong\u003e\u003cbr data-start=\"3227\" data-end=\"3230\"\u003eA: The transmitter integrates a differential pressure sensor with an \u003cstrong data-start=\"3299\" data-end=\"3324\"\u003eintegral flow orifice\u003c\/strong\u003e, allowing accurate measurement of very small flow rates.\u003c\/p\u003e\n\u003cp data-start=\"3383\" data-end=\"3591\"\u003e\u003cstrong data-start=\"3383\" data-end=\"3424\"\u003eQ: What output signals are available?\u003c\/strong\u003e\u003cbr data-start=\"3424\" data-end=\"3427\"\u003eA: The EJA115E typically provides \u003cstrong data-start=\"3461\" data-end=\"3503\"\u003e4–20 mA output with HART communication\u003c\/strong\u003e, and it can also support digital protocols such as FOUNDATION Fieldbus and PROFIBUS PA.\u003c\/p\u003e\n\u003cp data-start=\"3593\" data-end=\"3804\"\u003e\u003cstrong data-start=\"3593\" data-end=\"3654\"\u003eQ: Can the transmitter measure variables other than flow?\u003c\/strong\u003e\u003cbr data-start=\"3654\" data-end=\"3657\"\u003eA: Yes. In addition to flow derived from differential pressure, the transmitter can also monitor \u003cstrong data-start=\"3754\" data-end=\"3773\"\u003estatic pressure\u003c\/strong\u003e through digital communication.\u003c\/p\u003e\n\u003cp data-start=\"3806\" data-end=\"4026\"\u003e\u003cstrong data-start=\"3806\" data-end=\"3855\"\u003eQ: Which industries commonly use the EJA115E?\u003c\/strong\u003e\u003cbr data-start=\"3855\" data-end=\"3858\"\u003eA: The transmitter is widely used in chemical plants, gas processing facilities, research plants and other industrial processes requiring accurate low-flow measurement.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43329376092221,"sku":null,"price":480.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-eja115e-low-flow-transmitter..webp?v=1783479907"},{"product_id":"yokogawa-ragk-short-rotameter","title":"Yokogawa RAGK Short Rotameter","description":"\u003cp data-start=\"264\" data-end=\"638\"\u003eThe \u003cstrong data-start=\"268\" data-end=\"301\"\u003eYokogawa RAGK Short Rotameter\u003c\/strong\u003e is a compact variable area flow meter designed for accurate measurement of low liquid and gas flow rates. It features a conical glass metering tube with a free-moving float that provides direct visual indication of flow. Because of its simple mechanical design, the RAGK offers reliable flow monitoring without requiring external power.\u003c\/p\u003e\n\u003cp data-start=\"640\" data-end=\"832\"\u003eTypical Applications:\u003cbr data-start=\"661\" data-end=\"664\"\u003e• Gas sampling and analyzer systems\u003cbr data-start=\"699\" data-end=\"702\"\u003e• Laboratory flow measurement\u003cbr data-start=\"731\" data-end=\"734\"\u003e• Purging and dosing systems\u003cbr data-start=\"762\" data-end=\"765\"\u003e• Machinery and equipment monitoring\u003cbr data-start=\"801\" data-end=\"804\"\u003e• Small process flow control\u003c\/p\u003e\n\u003cp data-start=\"834\" data-end=\"958\"\u003eNot Recommended For:\u003cbr data-start=\"854\" data-end=\"857\"\u003e• Large pipeline flow measurement\u003cbr data-start=\"890\" data-end=\"893\"\u003e• Applications requiring high-precision digital flow transmitters\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/2\/798\/files\/RAGK_GS_GS01R01B07-00E-E_ed15_pub01042020.pdf?_gl=1*1rvo1f5*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003e RAGK Small Glass Rotameter \u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1232\" data-end=\"1250\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1252\" data-end=\"1646\"\u003e• Confirm the \u003cstrong data-start=\"1266\" data-end=\"1284\"\u003eprocess medium\u003c\/strong\u003e, such as liquid or gas.\u003cbr data-start=\"1308\" data-end=\"1311\"\u003e• Verify the required \u003cstrong data-start=\"1333\" data-end=\"1359\"\u003eflow measurement range\u003c\/strong\u003e for the application.\u003cbr data-start=\"1380\" data-end=\"1383\"\u003e• Select the suitable \u003cstrong data-start=\"1405\" data-end=\"1427\"\u003eprocess connection\u003c\/strong\u003e, including threaded or compression fittings.\u003cbr data-start=\"1472\" data-end=\"1475\"\u003e• Consider optional \u003cstrong data-start=\"1495\" data-end=\"1512\"\u003eneedle valves\u003c\/strong\u003e for precise flow adjustment.\u003cbr data-start=\"1541\" data-end=\"1544\"\u003e• In addition, check whether \u003cstrong data-start=\"1573\" data-end=\"1601\"\u003elimit switches or alarms\u003c\/strong\u003e are required for monitoring flow conditions.\u003c\/p\u003e\n\u003ch2 data-section-id=\"k2l823\" data-start=\"1680\" data-end=\"1727\"\u003eWhy Choose the Yokogawa RAGK Short Rotameter\u003c\/h2\u003e\n\u003cp data-start=\"1729\" data-end=\"1949\"\u003e• \u003cstrong data-start=\"1731\" data-end=\"1764\"\u003eAccurate Low Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"1764\" data-end=\"1767\"\u003eThe RAGK is designed for measuring small liquid or gas flow rates. Its tapered glass tube and float design allow stable and repeatable readings.\u003c\/p\u003e\n\u003cp data-start=\"1951\" data-end=\"2178\"\u003e• \u003cstrong data-start=\"1953\" data-end=\"1986\"\u003eDirect Visual Flow Indication\u003c\/strong\u003e\u003cbr data-start=\"1986\" data-end=\"1989\"\u003eFlow is indicated by the position of the float in the tube. Therefore, operators can quickly verify flow conditions without additional instrumentation.\u003c\/p\u003e\n\u003cp data-start=\"2180\" data-end=\"2403\"\u003e• \u003cstrong data-start=\"2182\" data-end=\"2208\"\u003eWide Measurement Range\u003c\/strong\u003e\u003cbr data-start=\"2208\" data-end=\"2211\"\u003eTypical measuring ranges include \u003cstrong data-start=\"2244\" data-end=\"2271\"\u003e0.002–600 L\/h for water\u003c\/strong\u003e and \u003cstrong data-start=\"2276\" data-end=\"2300\"\u003e0.2–6300 L\/h for air\u003c\/strong\u003e, making the rotameter suitable for many small-flow applications.\u003c\/p\u003e\n\u003cp data-start=\"2405\" data-end=\"2542\"\u003e• \u003cstrong data-start=\"2407\" data-end=\"2442\"\u003eCompact and Space-Saving Design\u003c\/strong\u003e\u003cbr data-start=\"2442\" data-end=\"2445\"\u003eThe short rotameter structure allows installation in equipment panels or compact process systems.\u003c\/p\u003e\n\u003cp data-start=\"2544\" data-end=\"2745\"\u003e• \u003cstrong data-start=\"2546\" data-end=\"2582\"\u003eOptional Flow Control and Alarms\u003c\/strong\u003e\u003cbr data-start=\"2582\" data-end=\"2585\"\u003eNeedle valves and limit switches can be integrated. As a result, the device can both monitor and regulate flow conditions.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2782\" data-end=\"2788\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2790\" data-end=\"2994\"\u003e\u003cstrong data-start=\"2790\" data-end=\"2838\"\u003eQ: How does the RAGK rotameter measure flow?\u003c\/strong\u003e\u003cbr data-start=\"2838\" data-end=\"2841\"\u003eA: The device uses a tapered glass tube with a floating element. The flow pushes the float upward, and the position of the float indicates the flow rate.\u003c\/p\u003e\n\u003cp data-start=\"2996\" data-end=\"3139\"\u003e\u003cstrong data-start=\"2996\" data-end=\"3047\"\u003eQ: Can the RAGK measure both liquids and gases?\u003c\/strong\u003e\u003cbr data-start=\"3047\" data-end=\"3050\"\u003eA: Yes. The rotameter is designed for measuring low flow rates of both liquids and gases.\u003c\/p\u003e\n\u003cp data-start=\"3141\" data-end=\"3294\"\u003e\u003cstrong data-start=\"3141\" data-end=\"3187\"\u003eQ: Does the RAGK require electrical power?\u003c\/strong\u003e\u003cbr data-start=\"3187\" data-end=\"3190\"\u003eA: No. The device provides mechanical flow indication, so it operates without any external power supply.\u003c\/p\u003e\n\u003cp data-start=\"3296\" data-end=\"3473\"\u003e\u003cstrong data-start=\"3296\" data-end=\"3345\"\u003eQ: Where is the RAGK rotameter commonly used?\u003c\/strong\u003e\u003cbr data-start=\"3345\" data-end=\"3348\"\u003eA: It is widely used in laboratory systems, analyzer panels, gas sampling units and small industrial flow monitoring systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43329376714813,"sku":null,"price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-ragk-short-rotameter.webp?v=1783480158"},{"product_id":"yokogawa-vortex-flowmeters-vy-series","title":"Yokogawa Vortex Flowmeters VY series","description":"\u003cp data-start=\"267\" data-end=\"735\"\u003eThe \u003cstrong data-start=\"271\" data-end=\"311\"\u003eYokogawa VY Series Vortex Flowmeters\u003c\/strong\u003e are advanced flow measurement instruments designed for accurate monitoring of liquids, gases and steam in industrial processes. Using vortex shedding technology and Yokogawa’s digital signal processing, the VY series delivers stable measurement even under vibration or fluctuating flow conditions. In addition, the flowmeter supports multiple communication protocols for seamless integration into modern automation systems.\u003c\/p\u003e\n\u003cp data-start=\"737\" data-end=\"999\"\u003eTypical Applications:\u003cbr data-start=\"758\" data-end=\"761\"\u003e• Steam flow measurement in power plants\u003cbr data-start=\"801\" data-end=\"804\"\u003e• Gas flow monitoring in industrial pipelines\u003cbr data-start=\"849\" data-end=\"852\"\u003e• Liquid flow measurement in chemical processing\u003cbr data-start=\"900\" data-end=\"903\"\u003e• Utility flow monitoring in manufacturing plants\u003cbr data-start=\"952\" data-end=\"955\"\u003e• Energy management and process optimization\u003c\/p\u003e\n\u003cp data-start=\"1001\" data-end=\"1147\"\u003eNot Recommended For:\u003cbr data-start=\"1021\" data-end=\"1024\"\u003e• Multiphase flows containing large amounts of solids\u003cbr data-start=\"1077\" data-end=\"1080\"\u003e• Highly viscous or sticky fluids that may affect vortex generation\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/GS01F07A00-01EN.pdf?_gl=1*1o4ja24*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003e Vortex Flowmeter VY Series\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1426\" data-end=\"1444\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1446\" data-end=\"1881\"\u003e• Confirm the \u003cstrong data-start=\"1460\" data-end=\"1482\"\u003eprocess fluid type\u003c\/strong\u003e, such as steam, gas or liquid.\u003cbr data-start=\"1513\" data-end=\"1516\"\u003e• Verify the required \u003cstrong data-start=\"1538\" data-end=\"1566\"\u003epipe size and flow range\u003c\/strong\u003e for the application.\u003cbr data-start=\"1587\" data-end=\"1590\"\u003e• Check the \u003cstrong data-start=\"1602\" data-end=\"1645\"\u003eprocess temperature and pressure limits\u003c\/strong\u003e before installation.\u003cbr data-start=\"1666\" data-end=\"1669\"\u003e• Choose the required \u003cstrong data-start=\"1691\" data-end=\"1717\"\u003ecommunication protocol\u003c\/strong\u003e, such as HART®, Modbus or FOUNDATION Fieldbus.\u003cbr data-start=\"1764\" data-end=\"1767\"\u003e• In addition, ensure the installation allows sufficient \u003cstrong data-start=\"1824\" data-end=\"1848\"\u003estraight pipe length\u003c\/strong\u003e for accurate vortex measurement.\u003c\/p\u003e\n\u003ch2 data-section-id=\"7p33hc\" data-start=\"1915\" data-end=\"1965\"\u003eWhy Choose Yokogawa Vortex Flowmeters VY Series\u003c\/h2\u003e\n\u003cp data-start=\"1967\" data-end=\"2243\"\u003e• \u003cstrong data-start=\"1969\" data-end=\"2020\"\u003eReliable Measurement for Steam, Gas and Liquids\u003c\/strong\u003e\u003cbr data-start=\"2020\" data-end=\"2023\"\u003eThe VY series can measure the flow of liquids, gases, saturated steam and superheated steam in industrial pipelines. This flexibility makes it suitable for many process industries.\u003c\/p\u003e\n\u003cp data-start=\"2245\" data-end=\"2516\"\u003e• \u003cstrong data-start=\"2247\" data-end=\"2271\"\u003eWide Operating Range\u003c\/strong\u003e\u003cbr data-start=\"2271\" data-end=\"2274\"\u003eThe flowmeter supports connection sizes from \u003cstrong data-start=\"2319\" data-end=\"2338\"\u003e15 mm to 400 mm\u003c\/strong\u003e and can operate at process temperatures up to \u003cstrong data-start=\"2385\" data-end=\"2395\"\u003e450 °C\u003c\/strong\u003e depending on the model. Therefore, it can handle demanding process environments.\u003c\/p\u003e\n\u003cp data-start=\"2518\" data-end=\"2748\"\u003e• \u003cstrong data-start=\"2520\" data-end=\"2550\"\u003eNo Moving Mechanical Parts\u003c\/strong\u003e\u003cbr data-start=\"2550\" data-end=\"2553\"\u003eVortex flowmeters use a simple sensing structure without moving components. As a result, they provide excellent durability and require minimal maintenance.\u003c\/p\u003e\n\u003cp data-start=\"2750\" data-end=\"3034\"\u003e• \u003cstrong data-start=\"2752\" data-end=\"2790\"\u003eAdvanced Digital Signal Processing\u003c\/strong\u003e\u003cbr data-start=\"2790\" data-end=\"2793\"\u003eYokogawa’s proprietary signal processing technology removes vibration noise and extracts the correct vortex signal. Consequently, measurement remains stable even in pipelines with mechanical vibration.\u003c\/p\u003e\n\u003cp data-start=\"3036\" data-end=\"3295\"\u003e• \u003cstrong data-start=\"3038\" data-end=\"3087\"\u003eIntegrated Diagnostics and Remote Maintenance\u003c\/strong\u003e\u003cbr data-start=\"3087\" data-end=\"3090\"\u003eThe VY series includes self-diagnostic functions and predictive maintenance features. These capabilities help reduce downtime and support efficient plant operations.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"3332\" data-end=\"3338\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"3340\" data-end=\"3501\"\u003e\u003cstrong data-start=\"3340\" data-end=\"3402\"\u003eQ: What fluids can the VY series vortex flowmeter measure?\u003c\/strong\u003e\u003cbr data-start=\"3402\" data-end=\"3405\"\u003eA: It can measure liquids, gases, saturated steam and superheated steam in industrial pipelines.\u003c\/p\u003e\n\u003cp data-start=\"3503\" data-end=\"3702\"\u003e\u003cstrong data-start=\"3503\" data-end=\"3569\"\u003eQ: Why are vortex flowmeters often used for steam measurement?\u003c\/strong\u003e\u003cbr data-start=\"3569\" data-end=\"3572\"\u003eA: Vortex meters handle high temperatures and pressures well. In addition, they maintain good accuracy for steam flow measurement.\u003c\/p\u003e\n\u003cp data-start=\"3704\" data-end=\"3902\"\u003e\u003cstrong data-start=\"3704\" data-end=\"3760\"\u003eQ: Does the VY series support digital communication?\u003c\/strong\u003e\u003cbr data-start=\"3760\" data-end=\"3763\"\u003eA: Yes. The flowmeter supports multiple protocols such as HART®, FOUNDATION Fieldbus and Modbus for integration with plant control systems.\u003c\/p\u003e\n\u003cp data-start=\"3904\" data-end=\"4078\"\u003e\u003cstrong data-start=\"3904\" data-end=\"3954\"\u003eQ: What industries commonly use the VY series?\u003c\/strong\u003e\u003cbr data-start=\"3954\" data-end=\"3957\"\u003eA: Typical industries include power generation, chemical processing, oil and gas, and manufacturing utilities management.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43329379303485,"sku":null,"price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-vy-series-vortex-flowmeter.webp?v=1783480620"},{"product_id":"yokogawa-rotamass-total-insight-coriolis-mass-flow-and-density-meters","title":"Yokogawa ROTAMASS Total Insight Coriolis Mass Flow and Density Meters","description":"\u003cp data-start=\"334\" data-end=\"751\"\u003eThe \u003cstrong data-start=\"338\" data-end=\"411\"\u003eYokogawa ROTAMASS Total Insight Coriolis Mass Flow and Density Meters\u003c\/strong\u003e provide highly accurate mass flow, density and temperature measurement for liquids and gases in industrial processes. Built on Yokogawa’s Total Insight concept, the ROTAMASS series delivers advanced diagnostics, flexible configuration and lifecycle support. As a result, it enables precise process monitoring and improved plant efficiency.\u003c\/p\u003e\n\u003cp data-start=\"753\" data-end=\"985\"\u003eTypical Applications:\u003cbr data-start=\"774\" data-end=\"777\"\u003e• Chemical and petrochemical processing\u003cbr data-start=\"816\" data-end=\"819\"\u003e• Oil and gas production and refining\u003cbr data-start=\"856\" data-end=\"859\"\u003e• Food and beverage manufacturing\u003cbr data-start=\"892\" data-end=\"895\"\u003e• Pharmaceutical and biotechnology processes\u003cbr data-start=\"939\" data-end=\"942\"\u003e• High-accuracy batching and dosing systems\u003c\/p\u003e\n\u003cp data-start=\"987\" data-end=\"1145\"\u003eNot Recommended For:\u003cbr data-start=\"1007\" data-end=\"1010\"\u003e• Applications where only volumetric flow measurement is required\u003cbr data-start=\"1075\" data-end=\"1078\"\u003e• Large pipelines where lower-cost flow technologies are sufficient\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/FY2_GS01U10B00-00EN-R_2_0_284564.pdf?_gl=1*s8xy5q*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003e ROTAMASS TI, Coriolis Mass Flow Meter, Specification Overview\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1475\" data-end=\"1493\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1495\" data-end=\"1907\"\u003e• Confirm the \u003cstrong data-start=\"1509\" data-end=\"1531\"\u003eprocess fluid type\u003c\/strong\u003e, including liquid or gas applications.\u003cbr data-start=\"1570\" data-end=\"1573\"\u003e• Verify the required \u003cstrong data-start=\"1595\" data-end=\"1628\"\u003emass flow range and pipe size\u003c\/strong\u003e.\u003cbr data-start=\"1629\" data-end=\"1632\"\u003e• Check the expected \u003cstrong data-start=\"1653\" data-end=\"1700\"\u003eprocess temperature and pressure conditions\u003c\/strong\u003e.\u003cbr data-start=\"1701\" data-end=\"1704\"\u003e• Select the appropriate \u003cstrong data-start=\"1729\" data-end=\"1755\"\u003ecommunication protocol\u003c\/strong\u003e, such as HART®, Modbus or PROFINET.\u003cbr data-start=\"1791\" data-end=\"1794\"\u003e• In addition, consider whether advanced functions such as \u003cstrong data-start=\"1853\" data-end=\"1893\"\u003edensity or concentration measurement\u003c\/strong\u003e are required.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1grz320\" data-start=\"1941\" data-end=\"2006\"\u003eWhy Choose Yokogawa ROTAMASS Total Insight Coriolis Flowmeters\u003c\/h2\u003e\n\u003cp data-start=\"2008\" data-end=\"2280\"\u003e• \u003cstrong data-start=\"2010\" data-end=\"2042\"\u003eDirect Mass Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"2042\" data-end=\"2045\"\u003eROTAMASS meters measure \u003cstrong data-start=\"2069\" data-end=\"2091\"\u003emass flow directly\u003c\/strong\u003e, eliminating the need for pressure or temperature compensation. Consequently, measurement accuracy remains stable even when process conditions change.\u003c\/p\u003e\n\u003cp data-start=\"2282\" data-end=\"2560\"\u003e• \u003cstrong data-start=\"2284\" data-end=\"2325\"\u003eMulti-Variable Measurement Capability\u003c\/strong\u003e\u003cbr data-start=\"2325\" data-end=\"2328\"\u003eThe meter can simultaneously measure \u003cstrong data-start=\"2365\" data-end=\"2403\"\u003emass flow, density and temperature\u003c\/strong\u003e. In addition, these values allow calculation of volume flow, concentration or viscosity for many industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"2562\" data-end=\"2780\"\u003e• \u003cstrong data-start=\"2564\" data-end=\"2593\"\u003eHigh Measurement Accuracy\u003c\/strong\u003e\u003cbr data-start=\"2593\" data-end=\"2596\"\u003eTypical accuracy reaches about \u003cstrong data-start=\"2627\" data-end=\"2673\"\u003e±0.1% for liquids and ±0.35–0.5% for gases\u003c\/strong\u003e, ensuring reliable measurement for critical industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"2782\" data-end=\"3009\"\u003e• \u003cstrong data-start=\"2784\" data-end=\"2806\"\u003eWide Process Range\u003c\/strong\u003e\u003cbr data-start=\"2806\" data-end=\"2809\"\u003eThe ROTAMASS family supports temperatures from \u003cstrong data-start=\"2856\" data-end=\"2886\"\u003e−70 °C up to around 350 °C\u003c\/strong\u003e depending on the model. Therefore, it can operate in demanding process environments.\u003c\/p\u003e\n\u003cp data-start=\"3011\" data-end=\"3272\"\u003e• \u003cstrong data-start=\"3013\" data-end=\"3040\"\u003eFlexible Product Family\u003c\/strong\u003e\u003cbr data-start=\"3040\" data-end=\"3043\"\u003eThe Total Insight platform includes multiple sensor series such as \u003cstrong data-start=\"3110\" data-end=\"3162\"\u003eNano, Prime, Hygienic, Supreme, Intense and Giga\u003c\/strong\u003e, allowing optimized solutions for different industries and flow ranges.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"3309\" data-end=\"3315\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"3317\" data-end=\"3534\"\u003e\u003cstrong data-start=\"3317\" data-end=\"3383\"\u003eQ: What variables can the ROTAMASS Coriolis flowmeter measure?\u003c\/strong\u003e\u003cbr data-start=\"3383\" data-end=\"3386\"\u003eA: The meter can measure mass flow, density and temperature simultaneously. These values can also be used to calculate volume flow or concentration.\u003c\/p\u003e\n\u003cp data-start=\"3536\" data-end=\"3718\"\u003e\u003cstrong data-start=\"3536\" data-end=\"3592\"\u003eQ: What industries commonly use ROTAMASS flowmeters?\u003c\/strong\u003e\u003cbr data-start=\"3592\" data-end=\"3595\"\u003eA: They are widely used in chemical processing, oil and gas, food and beverage production and pharmaceutical manufacturing.\u003c\/p\u003e\n\u003cp data-start=\"3720\" data-end=\"3914\"\u003e\u003cstrong data-start=\"3720\" data-end=\"3789\"\u003eQ: Does the ROTAMASS Total Insight support digital communication?\u003c\/strong\u003e\u003cbr data-start=\"3789\" data-end=\"3792\"\u003eA: Yes. The system supports multiple communication protocols including HART®, Modbus and industrial Ethernet technologies.\u003c\/p\u003e\n\u003cp data-start=\"3916\" data-end=\"4094\"\u003e\u003cstrong data-start=\"3916\" data-end=\"3974\"\u003eQ: What is the advantage of Coriolis flow measurement?\u003c\/strong\u003e\u003cbr data-start=\"3974\" data-end=\"3977\"\u003eA: Coriolis meters measure \u003cstrong data-start=\"4004\" data-end=\"4026\"\u003emass flow directly\u003c\/strong\u003e, which reduces errors caused by temperature or pressure variations.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43329379663933,"sku":null,"price":4500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-rotamass-total-insight-coriolis-flowmeter.webp?v=1783480838"},{"product_id":"yokogawa-ejxc40a-digital-remote-sensor-drs-differential-pressure-system","title":"Yokogawa EJXC40A Digital Remote Sensor (DRS) Differential Pressure System","description":"\u003cp data-start=\"244\" data-end=\"471\"\u003eThe \u003cstrong data-start=\"248\" data-end=\"287\"\u003eEJXC40A Digital Remote Sensor (DRS)\u003c\/strong\u003e is a high-performance differential pressure measurement system from Yokogawa. It is designed for \u003cstrong data-start=\"385\" data-end=\"421\"\u003eaccurate and reliable monitoring\u003c\/strong\u003e of differential pressure in industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"473\" data-end=\"642\"\u003eThe system integrates a \u003cstrong data-start=\"497\" data-end=\"543\"\u003edigital sensor with remote diaphragm seals\u003c\/strong\u003e, allowing stable measurement in harsh conditions, such as corrosive or high-temperature processes.\u003c\/p\u003e\n\u003cp data-start=\"644\" data-end=\"667\"\u003eKey features include:\u003c\/p\u003e\n\u003cp data-start=\"669\" data-end=\"869\"\u003e• ±0.075% span accuracy\u003cbr data-start=\"692\" data-end=\"695\"\u003e• Remote diaphragm seals for challenging media\u003cbr data-start=\"741\" data-end=\"744\"\u003e• Fast response time for process control\u003cbr data-start=\"784\" data-end=\"787\"\u003e• HART communication compatibility\u003cbr data-start=\"821\" data-end=\"824\"\u003e• SIL2\/SIL3 functional safety certification\u003c\/p\u003e\n\u003cp data-start=\"871\" data-end=\"1067\"\u003eApplications include flow measurement, filter monitoring, level measurement in closed tanks, and pressure drop detection in chemical, petrochemical, and water treatment industries.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/GS01C25W05-01EN.pdf?_gl=1*huhytd*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003e EJXC40A Digital Remote Sensor \u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1074\" data-end=\"1092\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1094\" data-end=\"1295\"\u003eWhen selecting the EJXC40A system, first identify the \u003cstrong data-start=\"1148\" data-end=\"1179\"\u003edifferential pressure range\u003c\/strong\u003e and the \u003cstrong data-start=\"1188\" data-end=\"1206\"\u003eprocess medium\u003c\/strong\u003e. Different diaphragm seals and fill fluids are available to match specific applications.\u003c\/p\u003e\n\u003cp data-start=\"1297\" data-end=\"1468\"\u003eNext, check the \u003cstrong data-start=\"1313\" data-end=\"1341\"\u003eremote mounting distance\u003c\/strong\u003e and installation configuration. The sensor can be installed away from the process, which reduces exposure to harsh conditions.\u003c\/p\u003e\n\u003cp data-start=\"1470\" data-end=\"1595\"\u003eAdditionally, confirm the \u003cstrong data-start=\"1496\" data-end=\"1522\"\u003ecommunication protocol\u003c\/strong\u003e. The system supports HART for integration with existing control systems.\u003c\/p\u003e\n\u003cp data-start=\"1597\" data-end=\"1728\"\u003eFinally, ensure that the device meets \u003cstrong data-start=\"1635\" data-end=\"1690\"\u003ehazardous area and functional safety certifications\u003c\/strong\u003e, according to your site requirements.\u003c\/p\u003e\n\u003chr data-start=\"1730\" data-end=\"1733\"\u003e\n\u003ch2 data-section-id=\"r59jil\" data-start=\"1735\" data-end=\"1765\"\u003eWhy Choose Yokogawa EJXC40A\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1igmvpb\" data-start=\"1767\" data-end=\"1796\"\u003eHigh Measurement Accuracy\u003c\/h3\u003e\n\u003cp data-start=\"1798\" data-end=\"1939\"\u003eThe EJXC40A delivers \u003cstrong data-start=\"1819\" data-end=\"1853\"\u003eup to ±0.075% of span accuracy\u003c\/strong\u003e, providing precise differential pressure data for critical processes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"apb8tl\" data-start=\"1941\" data-end=\"1978\"\u003eRemote Diaphragm Seal Flexibility\u003c\/h3\u003e\n\u003cp data-start=\"1980\" data-end=\"2187\"\u003eThe system allows \u003cstrong data-start=\"1998\" data-end=\"2038\"\u003eremote mounting up to several meters\u003c\/strong\u003e. This design protects the transmitter from extreme temperatures, corrosive fluids, or clogging, improving longevity and reliability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nyeqer\" data-start=\"2189\" data-end=\"2213\"\u003eFast Sensor Response\u003c\/h3\u003e\n\u003cp data-start=\"2215\" data-end=\"2358\"\u003eThe digital sensor responds quickly to pressure changes, ensuring timely process control and reduced risk of process deviation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13gcn6b\" data-start=\"2360\" data-end=\"2393\"\u003eDigital Communication Support\u003c\/h3\u003e\n\u003cp data-start=\"2395\" data-end=\"2578\"\u003eHART communication enables seamless integration with DCS or SCADA systems. Additionally, the sensor continuously monitors measurement signals for enhanced diagnostics.\u003c\/p\u003e\n\u003ch3 data-section-id=\"6xs52z\" data-start=\"2580\" data-end=\"2611\"\u003eSIL2\/SIL3 Functional Safety\u003c\/h3\u003e\n\u003cp data-start=\"2613\" data-end=\"2762\"\u003eThe EJXC40A supports functional safety standards, making it suitable for applications where safety instrumented systems are required.\u003c\/p\u003e\n\u003chr data-start=\"2764\" data-end=\"2767\"\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2769\" data-end=\"2775\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2777\" data-end=\"2919\"\u003e\u003cstrong data-start=\"2777\" data-end=\"2828\"\u003eWhat type of pressure does the EJXC40A measure?\u003c\/strong\u003e\u003cbr data-start=\"2828\" data-end=\"2831\"\u003eIt measures \u003cstrong data-start=\"2843\" data-end=\"2868\"\u003edifferential pressure\u003c\/strong\u003e, suitable for gas, liquid, and steam applications.\u003c\/p\u003e\n\u003cp data-start=\"2921\" data-end=\"3096\"\u003e\u003cstrong data-start=\"2921\" data-end=\"2967\"\u003eCan the transmitter be installed remotely?\u003c\/strong\u003e\u003cbr data-start=\"2967\" data-end=\"2970\"\u003eYes. The remote diaphragm seal allows mounting at a distance from the process, ideal for high-temperature or corrosive fluids.\u003c\/p\u003e\n\u003cp data-start=\"3098\" data-end=\"3247\"\u003e\u003cstrong data-start=\"3098\" data-end=\"3144\"\u003eWhat industries typically use this system?\u003c\/strong\u003e\u003cbr data-start=\"3144\" data-end=\"3147\"\u003eCommon industries include chemical, petrochemical, water treatment, oil \u0026amp; gas, and power generation.\u003c\/p\u003e\n\u003cp data-start=\"3249\" data-end=\"3399\"\u003e\u003cstrong data-start=\"3249\" data-end=\"3297\"\u003eWhich communication protocols are supported?\u003c\/strong\u003e\u003cbr data-start=\"3297\" data-end=\"3300\"\u003eHART protocol is supported, allowing easy integration with process control systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43329379729469,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-ejxc40a-digital-remote-sensor-drs.webp?v=1783481011"},{"product_id":"yokogawa-ejx120a-draft-range-differential-pressure-transmitter","title":"Yokogawa EJX120A Draft Range Differential Pressure Transmitter","description":"\u003cp data-start=\"306\" data-end=\"631\"\u003eThe \u003cstrong data-start=\"310\" data-end=\"367\"\u003eEJX120A draft range differential pressure transmitter\u003c\/strong\u003e is designed for high‑accuracy low differential pressure measurement in industrial processes. It is part of Yokogawa’s EJX‑A series and uses a \u003cstrong data-start=\"510\" data-end=\"544\"\u003edigital DPharp pressure sensor\u003c\/strong\u003e for improved performance and long‑term stability.\u003c\/p\u003e\n\u003cp data-start=\"633\" data-end=\"1014\"\u003eIn addition, the transmitter supports advanced diagnostics and digital communication. These features help users monitor process conditions more reliably and reduce unscheduled maintenance. Typical applications include low‑flow measurement, draft measurement, and critical process control loops in chemical, power and water treatment facilities.\u003c\/p\u003e\n\u003cp data-start=\"1016\" data-end=\"1049\"\u003eKey performance features include:\u003c\/p\u003e\n\u003cp data-start=\"1051\" data-end=\"1236\"\u003e• ±0.09% of span reference accuracy\u003cbr data-start=\"1086\" data-end=\"1089\"\u003e• 150 ms response time\u003cbr data-start=\"1111\" data-end=\"1114\"\u003e• Excellent long‑term stability\u003cbr data-start=\"1145\" data-end=\"1148\"\u003e• Digital diagnostics and communications\u003cbr data-start=\"1188\" data-end=\"1191\"\u003e• SIL2\/SIL3 functional safety certification\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/web-material3.yokogawa.com\/GS01C25B03-01EN.pdf?_gl=1*11z2t7d*_gcl_aw*R0NMLjE3NTgwOTIyNzcuQ2p3S0NBandsYVRHQmhBTkVpd0FvUmdYQmNHLU8tRXJDZXFSRHVOaVNGOHVCMlhJLUpYUG15aHdTRWp4c1dOSHlPWG92Q3JydkczTHRob0NSSTRRQXZEX0J3RQ..*_gcl_au*MTM5ODAzMDEwMi4xNzU4MDE2MTAx\"\u003e EJX120A Differential Pressure Transmitter \u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1243\" data-end=\"1261\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1263\" data-end=\"1432\"\u003eBefore selecting the EJX120A transmitter, first confirm the \u003cstrong data-start=\"1323\" data-end=\"1354\"\u003edifferential pressure range\u003c\/strong\u003e you need to measure, especially if you are handling very low draft pressures.\u003c\/p\u003e\n\u003cp data-start=\"1434\" data-end=\"1561\"\u003eNext, check the \u003cstrong data-start=\"1450\" data-end=\"1491\"\u003eprocess connection and mounting style\u003c\/strong\u003e to ensure compatibility with your existing manifolds or piping setup.\u003c\/p\u003e\n\u003cp data-start=\"1563\" data-end=\"1716\"\u003eThen, choose the appropriate \u003cstrong data-start=\"1592\" data-end=\"1618\"\u003ecommunication protocol\u003c\/strong\u003e, such as HART, FOUNDATION Fieldbus or PROFIBUS PA, depending on your control system requirements.\u003c\/p\u003e\n\u003cp data-start=\"1718\" data-end=\"1884\"\u003eFinally, verify that the transmitter’s \u003cstrong data-start=\"1757\" data-end=\"1792\"\u003efunctional safety certification\u003c\/strong\u003e and environmental ratings match the hazardous area classification of the installation site.\u003c\/p\u003e\n\u003chr data-start=\"1886\" data-end=\"1889\"\u003e\n\u003ch2 data-section-id=\"r4wg1l\" data-start=\"1891\" data-end=\"1921\"\u003eWhy Choose Yokogawa EJX120A\u003c\/h2\u003e\n\u003ch3 data-section-id=\"10zxdnz\" data-start=\"1923\" data-end=\"1965\"\u003eHigh‑Accuracy Differential Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1967\" data-end=\"2147\"\u003eThe EJX120A delivers \u003cstrong data-start=\"1988\" data-end=\"2015\"\u003e±0.09% of span accuracy\u003c\/strong\u003e, suitable for precise measurement where low differential pressures must be tracked accurately.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nyeqer\" data-start=\"2149\" data-end=\"2173\"\u003eFast Sensor Response\u003c\/h3\u003e\n\u003cp data-start=\"2175\" data-end=\"2371\"\u003eWith a \u003cstrong data-start=\"2182\" data-end=\"2206\"\u003e150 ms response time\u003c\/strong\u003e, this transmitter quickly reflects changes in process conditions, which is essential for responsive control and safety systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1njgbly\" data-start=\"2373\" data-end=\"2405\"\u003eStable Long‑Term Performance\u003c\/h3\u003e\n\u003cp data-start=\"2407\" data-end=\"2586\"\u003eThe transmitter provides excellent stability over time, which helps \u003cstrong data-start=\"2475\" data-end=\"2509\"\u003eextend recalibration intervals\u003c\/strong\u003e and reduce lifecycle maintenance costs.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1w7uzkc\" data-start=\"2588\" data-end=\"2612\"\u003eAdvanced Diagnostics\u003c\/h3\u003e\n\u003cp data-start=\"2614\" data-end=\"2797\"\u003eBuilt‑in diagnostics constantly monitor sensor health and measurement integrity, enabling easier troubleshooting and fewer surprises in operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"f3i8se\" data-start=\"2799\" data-end=\"2835\"\u003eFunctional Safety Certifications\u003c\/h3\u003e\n\u003cp data-start=\"2837\" data-end=\"3014\"\u003eThe EJX120A meets \u003cstrong data-start=\"2855\" data-end=\"2885\"\u003eSIL2\/SIL3 safety standards\u003c\/strong\u003e without requiring special options, making it suitable for use in safety instrumented loops.\u003c\/p\u003e\n\u003chr data-start=\"3016\" data-end=\"3019\"\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"3021\" data-end=\"3027\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"3029\" data-end=\"3250\"\u003e\u003cstrong data-start=\"3029\" data-end=\"3080\"\u003eWhat type of pressure does the EJX120A measure?\u003c\/strong\u003e\u003cbr data-start=\"3080\" data-end=\"3083\"\u003eIt measures \u003cstrong data-start=\"3095\" data-end=\"3148\"\u003edifferential pressure in draft range applications\u003c\/strong\u003e, making it suitable for low‑pressure measurements such as flow, level or filter condition monitoring.\u003c\/p\u003e\n\u003cp data-start=\"3252\" data-end=\"3431\"\u003e\u003cstrong data-start=\"3252\" data-end=\"3300\"\u003eWhich communication protocols are supported?\u003c\/strong\u003e\u003cbr data-start=\"3300\" data-end=\"3303\"\u003eAvailable protocols include HART, FOUNDATION Fieldbus and PROFIBUS PA (depending on model).\u003c\/p\u003e\n\u003cp data-start=\"3433\" data-end=\"3618\"\u003e\u003cstrong data-start=\"3433\" data-end=\"3489\"\u003eCan this transmitter handle different process media?\u003c\/strong\u003e\u003cbr data-start=\"3489\" data-end=\"3492\"\u003eYes. EJX120A can measure differential pressure in \u003cstrong data-start=\"3542\" data-end=\"3580\"\u003egas, liquid and steam applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3620\" data-end=\"3865\"\u003e\u003cstrong data-start=\"3620\" data-end=\"3665\"\u003eWhere is this transmitter typically used?\u003c\/strong\u003e\u003cbr data-start=\"3665\" data-end=\"3668\"\u003eTypical industries include \u003cstrong data-start=\"3695\" data-end=\"3827\"\u003echemical processing, power generation, water treatment, and any facility requiring precise low differential pressure measurement\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43330056159293,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/yokogawa-ejx120a-draft-range-differential-pressure-transmitter.png?v=1783493549"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/collections\/yokogawa.png?v=1782963163","url":"https:\/\/proinstru.com\/collections\/yokogawa.oembed","provider":"Process Instrument","version":"1.0","type":"link"}