{"title":"Honeywell","description":"\u003cp data-start=\"106\" data-end=\"407\" class=\"PDq2pG_selectionAnchorContainer\"\u003eHoneywell is a global leader in industrial automation, process control, and advanced technology solutions, providing reliable products for monitoring, control, and operational efficiency. Its solutions are widely used in oil \u0026amp; gas, manufacturing, energy, aerospace, and building automation industries.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"409\" data-end=\"554\"\u003eKnown for innovation, safety, and high performance, Honeywell products help improve productivity, process reliability, and industrial operations.\u003c\/p\u003e","products":[{"product_id":"honeywell-slg700-radar-level-transmitter","title":"Honeywell SLG700 Guided Wave Radar Level Transmitter","description":"\u003ch1 data-section-id=\"621vkf\" data-start=\"532\" data-end=\"573\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"608\" data-end=\"870\"\u003eThe \u003cstrong data-start=\"612\" data-end=\"678\"\u003eHoneywell SmartLine SLG700 Guided Wave Radar Level Transmitter\u003c\/strong\u003e is a high-performance industrial \u003cstrong data-start=\"712\" data-end=\"739\"\u003eradar level transmitter\u003c\/strong\u003e designed for accurate and stable \u003cstrong data-start=\"773\" data-end=\"799\"\u003etank level measurement\u003c\/strong\u003e and \u003cstrong data-start=\"804\" data-end=\"835\"\u003einterface level measurement\u003c\/strong\u003e in demanding process environments.\u003c\/p\u003e\n\u003cp data-start=\"872\" data-end=\"1073\"\u003eIt uses guided wave radar technology to provide continuous and reliable level detection even under challenging conditions such as vapor, turbulence, foam, pressure changes, or temperature fluctuations.\u003c\/p\u003e\n\u003cp data-start=\"1075\" data-end=\"1275\"\u003eThe SLG700 is widely used in industrial automation systems where high reliability and accuracy are required, including chemical processing, oil \u0026amp; gas, power generation, and water treatment industries.\u003c\/p\u003e\n\u003cp data-start=\"1277\" data-end=\"1403\"\u003eIt is a trusted solution for applications requiring long-term stability in \u003cstrong data-start=\"1352\" data-end=\"1394\"\u003eindustrial level transmitter Honeywell\u003c\/strong\u003e systems.\u003c\/p\u003e\n\u003chr data-start=\"1405\" data-end=\"1408\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1410\" data-end=\"1426\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1428\" data-end=\"1810\"\u003e• High-accuracy guided wave radar measurement\u003cbr data-start=\"1473\" data-end=\"1476\"\u003e• Stable tank level measurement in harsh conditions\u003cbr data-start=\"1527\" data-end=\"1530\"\u003e• Supports interface level measurement applications\u003cbr data-start=\"1581\" data-end=\"1584\"\u003e• Reliable performance in vapor, foam, and pressure variation\u003cbr data-start=\"1645\" data-end=\"1648\"\u003e• Flexible probe configurations for different applications\u003cbr data-start=\"1706\" data-end=\"1709\"\u003e• Low-maintenance design with no moving parts\u003cbr data-start=\"1754\" data-end=\"1757\"\u003e• Continuous industrial-grade operation reliability\u003c\/p\u003e\n\u003chr data-start=\"1812\" data-end=\"1815\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1817\" data-end=\"1843\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1845\" data-end=\"2140\"\u003e\n\u003cli data-section-id=\"1a7u4jh\" data-start=\"1845\" data-end=\"1879\"\u003eStorage tank level measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1tpgrr8\" data-start=\"1880\" data-end=\"1909\"\u003eChemical processing tanks\u003c\/li\u003e\n\u003cli data-section-id=\"11agh3g\" data-start=\"1910\" data-end=\"1942\"\u003eOil \u0026amp; gas processing systems\u003c\/li\u003e\n\u003cli data-section-id=\"hcl0oj\" data-start=\"1943\" data-end=\"1977\"\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"79zscl\" data-start=\"1978\" data-end=\"2005\"\u003ePower generation plants\u003c\/li\u003e\n\u003cli data-section-id=\"lfaiut\" data-start=\"2006\" data-end=\"2044\"\u003eIndustrial process control systems\u003c\/li\u003e\n\u003cli data-section-id=\"cx30j4\" data-start=\"2045\" data-end=\"2103\"\u003eInterface level measurement (oil\/water, liquid layers)\u003c\/li\u003e\n\u003cli data-section-id=\"14ezqe2\" data-start=\"2104\" data-end=\"2140\"\u003eSilo and vessel level monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2142\" data-end=\"2145\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2147\" data-end=\"2180\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2182\" data-end=\"2215\"\u003eBefore selecting SLG700, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2217\" data-end=\"2582\"\u003e\n\u003cli data-section-id=\"tqnskn\" data-start=\"2217\" data-end=\"2266\"\u003eRequired measurement type: level or interface\u003c\/li\u003e\n\u003cli data-section-id=\"uvvsz9\" data-start=\"2267\" data-end=\"2304\"\u003eTank size and installation height\u003c\/li\u003e\n\u003cli data-section-id=\"18vank4\" data-start=\"2305\" data-end=\"2358\"\u003eMedium type (liquid, corrosive, conductive, etc.)\u003c\/li\u003e\n\u003cli data-section-id=\"otlfd4\" data-start=\"2359\" data-end=\"2421\"\u003eProcess conditions (temperature, pressure, vapor presence)\u003c\/li\u003e\n\u003cli data-section-id=\"pdw1ns\" data-start=\"2422\" data-end=\"2467\"\u003eProbe selection and mounting requirements\u003c\/li\u003e\n\u003cli data-section-id=\"5jaq70\" data-start=\"2468\" data-end=\"2522\"\u003eOutput compatibility with control system (PLC\/DCS)\u003c\/li\u003e\n\u003cli data-section-id=\"1vm4zgc\" data-start=\"2523\" data-end=\"2582\"\u003eRequired installation environment and space limitations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2584\" data-end=\"2587\"\u003e\n\u003ch1 data-section-id=\"gzgpio\" data-start=\"2589\" data-end=\"2610\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2612\" data-end=\"2776\"\u003e\u003cstrong data-start=\"2612\" data-end=\"2657\"\u003eQ: What is the Honeywell SLG700 used for?\u003c\/strong\u003e\u003cbr data-start=\"2657\" data-end=\"2660\"\u003eA: It is used for accurate \u003cstrong data-start=\"2687\" data-end=\"2745\"\u003etank level measurement and interface level measurement\u003c\/strong\u003e in industrial process systems.\u003c\/p\u003e\n\u003cp data-start=\"2778\" data-end=\"2932\"\u003e\u003cstrong data-start=\"2778\" data-end=\"2810\"\u003eQ: How does the SLG700 work?\u003c\/strong\u003e\u003cbr data-start=\"2810\" data-end=\"2813\"\u003eA: It uses \u003cstrong data-start=\"2824\" data-end=\"2856\"\u003eguided wave radar technology\u003c\/strong\u003e to send signals along a probe and measure level based on signal reflection.\u003c\/p\u003e\n\u003cp data-start=\"2934\" data-end=\"3078\"\u003e\u003cstrong data-start=\"2934\" data-end=\"2973\"\u003eQ: Can it measure interface levels?\u003c\/strong\u003e\u003cbr data-start=\"2973\" data-end=\"2976\"\u003eA: Yes, it can measure both liquid level and \u003cstrong data-start=\"3021\" data-end=\"3054\"\u003einterface between two liquids\u003c\/strong\u003e, such as oil and water.\u003c\/p\u003e\n\u003cp data-start=\"3080\" data-end=\"3236\"\u003e\u003cstrong data-start=\"3080\" data-end=\"3125\"\u003eQ: Is it suitable for harsh environments?\u003c\/strong\u003e\u003cbr data-start=\"3125\" data-end=\"3128\"\u003eA: Yes, it performs reliably in conditions with vapor, foam, pressure changes, and temperature fluctuations.\u003c\/p\u003e\n\u003cp data-start=\"3238\" data-end=\"3386\"\u003e\u003cstrong data-start=\"3238\" data-end=\"3282\"\u003eQ: What industries use this transmitter?\u003c\/strong\u003e\u003cbr data-start=\"3282\" data-end=\"3285\"\u003eA: It is widely used in oil \u0026amp; gas, chemical processing, power plants, and water treatment industries.\u003c\/p\u003e\n\u003cp data-start=\"3388\" data-end=\"3524\"\u003e\u003cstrong data-start=\"3388\" data-end=\"3431\"\u003eQ: Does it require regular maintenance?\u003c\/strong\u003e\u003cbr data-start=\"3431\" data-end=\"3434\"\u003eA: No, it has a low-maintenance design with no moving parts, ensuring long-term stability.\u003c\/p\u003e\n\u003cp data-start=\"3526\" data-end=\"3662\"\u003e\u003cstrong data-start=\"3526\" data-end=\"3574\"\u003eQ: Is it compatible with PLC or DCS systems?\u003c\/strong\u003e\u003cbr data-start=\"3574\" data-end=\"3577\"\u003eA: Yes, it can integrate with PLC and DCS control systems depending on configuration.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43309059473469,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/slg700-level-transmitter.png?v=1782801927"},{"product_id":"honeywell-smartline-stg700-pressure-transmitter","title":"Honeywell SmartLine STG700 Pressure Transmitter","description":"\u003ch1 data-section-id=\"k5tk9i\" data-start=\"698\" data-end=\"722\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"724\" data-end=\"1001\"\u003eThe \u003cstrong data-start=\"728\" data-end=\"779\"\u003eHoneywell SmartLine STG700 Pressure Transmitter\u003c\/strong\u003e is designed for reliable and accurate industrial pressure measurement in demanding process environments. Built for continuous process monitoring, it delivers stable performance across a wide range of operating conditions.\u003c\/p\u003e\n\u003cp data-start=\"1003\" data-end=\"1326\"\u003eThe STG700 supports accurate \u003cstrong data-start=\"1032\" data-end=\"1064\"\u003eprocess pressure measurement\u003c\/strong\u003e for liquids and gases while allowing easy integration into automation systems through industrial communication options. Its robust construction and flexible configuration capabilities help improve process efficiency and maintain long-term operational stability.\u003c\/p\u003e\n\u003cp data-start=\"1328\" data-end=\"1738\"\u003eThe transmitter is widely used in industries where dependable \u003cstrong data-start=\"1390\" data-end=\"1420\"\u003eindustrial pressure sensor\u003c\/strong\u003e performance is required, including oil \u0026amp; gas, chemical processing, power generation, manufacturing, and utility systems. Natural SEO keywords included: \u003cstrong data-start=\"1573\" data-end=\"1597\"\u003epressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1599\" data-end=\"1629\"\u003eindustrial pressure sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1631\" data-end=\"1663\"\u003eprocess pressure measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1665\" data-end=\"1699\"\u003eHoneywell pressure transmitter\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1740\" data-end=\"1743\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1745\" data-end=\"1761\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1763\" data-end=\"2174\"\u003e• High-accuracy pressure measurement\u003cbr data-start=\"1799\" data-end=\"1802\"\u003e• Long-term measurement stability\u003cbr data-start=\"1835\" data-end=\"1838\"\u003e• Supports HART and industrial communication protocols\u003cbr data-start=\"1892\" data-end=\"1895\"\u003e• Wide pressure range options available\u003cbr data-start=\"1934\" data-end=\"1937\"\u003e• Fast response time for process monitoring\u003cbr data-start=\"1980\" data-end=\"1983\"\u003e• Robust industrial design for harsh environments\u003cbr data-start=\"2032\" data-end=\"2035\"\u003e• Flexible configuration and installation options\u003cbr data-start=\"2084\" data-end=\"2087\"\u003e• Suitable for continuous operation applications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2176\" data-end=\"2179\"\u003e\n\u003ch1 data-section-id=\"18oyf1a\" data-start=\"2181\" data-end=\"2198\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2200\" data-end=\"2478\"\u003e\n\u003cli data-section-id=\"180zpbe\" data-start=\"2200\" data-end=\"2231\"\u003eProcess pressure monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"eg6nxd\" data-start=\"2232\" data-end=\"2266\"\u003eOil and gas processing systems\u003c\/li\u003e\n\u003cli data-section-id=\"buhxms\" data-start=\"2267\" data-end=\"2301\"\u003eChemical processing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"14yrykg\" data-start=\"2302\" data-end=\"2341\"\u003eTank and vessel pressure monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"79zscl\" data-start=\"2342\" data-end=\"2369\"\u003ePower generation plants\u003c\/li\u003e\n\u003cli data-section-id=\"hcl0oj\" data-start=\"2370\" data-end=\"2404\"\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"10q3r02\" data-start=\"2405\" data-end=\"2443\"\u003eIndustrial manufacturing processes\u003c\/li\u003e\n\u003cli data-section-id=\"134gg7e\" data-start=\"2444\" data-end=\"2478\"\u003eUtility and automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2480\" data-end=\"2483\"\u003e\n\u003ch1 data-section-id=\"17qep6b\" data-start=\"2485\" data-end=\"2505\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2507\" data-end=\"2540\"\u003eBefore selecting STG700, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2542\" data-end=\"2842\"\u003e\n\u003cli data-section-id=\"n5stmj\" data-start=\"2542\" data-end=\"2569\"\u003eRequired pressure range\u003c\/li\u003e\n\u003cli data-section-id=\"175qydg\" data-start=\"2570\" data-end=\"2631\"\u003ePressure type (gauge, vacuum, or application requirement)\u003c\/li\u003e\n\u003cli data-section-id=\"ztmafk\" data-start=\"2632\" data-end=\"2664\"\u003eProcess medium compatibility\u003c\/li\u003e\n\u003cli data-section-id=\"ztcfq1\" data-start=\"2665\" data-end=\"2700\"\u003eProcess connection requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1x2syez\" data-start=\"2701\" data-end=\"2749\"\u003eOutput compatibility with PLC or DCS systems\u003c\/li\u003e\n\u003cli data-section-id=\"cshpwt\" data-start=\"2750\" data-end=\"2799\"\u003eEnvironmental and hazardous area requirements\u003c\/li\u003e\n\u003cli data-section-id=\"mcf79a\" data-start=\"2800\" data-end=\"2842\"\u003eInstallation and mounting requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2844\" data-end=\"2847\"\u003e\n\u003ch1 data-section-id=\"1lxd8kj\" data-start=\"2849\" data-end=\"2856\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2858\" data-end=\"3058\"\u003e\u003cstrong data-start=\"2858\" data-end=\"2903\"\u003eQ: What is the Honeywell STG700 used for?\u003c\/strong\u003e\u003cbr data-start=\"2903\" data-end=\"2906\"\u003eA: It is used for industrial pressure monitoring and process measurement applications involving liquids and gases. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3060\" data-end=\"3280\"\u003e\u003cstrong data-start=\"3060\" data-end=\"3122\"\u003eQ: Does STG700 support industrial communication protocols?\u003c\/strong\u003e\u003cbr data-start=\"3122\" data-end=\"3125\"\u003eA: Yes. Depending on configuration, it supports communication options including HART and standard industrial outputs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3282\" data-end=\"3439\"\u003e\u003cstrong data-start=\"3282\" data-end=\"3323\"\u003eQ: Can it integrate with PLC systems?\u003c\/strong\u003e\u003cbr data-start=\"3323\" data-end=\"3326\"\u003eA: Yes, it can be integrated into PLC and DCS process control environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3441\" data-end=\"3651\"\u003e\u003cstrong data-start=\"3441\" data-end=\"3501\"\u003eQ: Is STG700 suitable for harsh industrial environments?\u003c\/strong\u003e\u003cbr data-start=\"3501\" data-end=\"3504\"\u003eA: Yes. It is designed for demanding process conditions requiring long-term reliability and stable operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3653\" data-end=\"3813\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3696\"\u003eQ: What industries commonly use STG700?\u003c\/strong\u003e\u003cbr data-start=\"3696\" data-end=\"3699\"\u003eA: Common industries include oil \u0026amp; gas, chemical processing, manufacturing, utility systems, and power generation.\u003c\/p\u003e\n\u003cp data-start=\"3815\" data-end=\"3992\"\u003e\u003cstrong data-start=\"3815\" data-end=\"3865\"\u003eQ: Does it support long-term stable operation?\u003c\/strong\u003e\u003cbr data-start=\"3865\" data-end=\"3868\"\u003eA: Yes. The SmartLine series is designed for long-term stability and process accuracy.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43311177400381,"sku":null,"price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/stg700-pressure-transmitter-product-view.png?v=1782876953"},{"product_id":"honeywell-sensepoint-xcd-gas-detector","title":"Honeywell Sensepoint XCD Gas Detector","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"662\" data-end=\"698\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"700\" data-end=\"902\"\u003eThe \u003cstrong data-start=\"704\" data-end=\"745\"\u003eHoneywell Sensepoint XCD Gas Detector\u003c\/strong\u003e is a fixed-point industrial gas detection system designed to continuously monitor flammable gases, toxic gases, and oxygen levels in hazardous environments.\u003c\/p\u003e\n\u003cp data-start=\"904\" data-end=\"1206\"\u003eIt integrates a transmitter and sensor into a single platform, providing real-time gas concentration monitoring with visual, audible, and relay alarms. The system supports remote sensor mounting, making it suitable for hard-to-access installation areas while maintaining reliable detection performance.\u003c\/p\u003e\n\u003cp data-start=\"1208\" data-end=\"1425\"\u003eWith support for catalytic, infrared, and electrochemical sensing technologies, Sensepoint XCD is widely used in industrial safety systems where continuous \u003cstrong data-start=\"1364\" data-end=\"1386\"\u003egas leak detection\u003c\/strong\u003e and personnel protection are critical.\u003c\/p\u003e\n\u003cp data-start=\"1427\" data-end=\"1595\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1458\" data-end=\"1474\"\u003egas detector\u003c\/strong\u003e, \u003cstrong data-start=\"1476\" data-end=\"1506\"\u003efixed gas detection system\u003c\/strong\u003e, \u003cstrong data-start=\"1508\" data-end=\"1534\"\u003eindustrial gas monitor\u003c\/strong\u003e, \u003cstrong data-start=\"1536\" data-end=\"1557\"\u003eoxygen gas sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1559\" data-end=\"1595\"\u003eflammable gas detector Honeywell\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1597\" data-end=\"1600\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1602\" data-end=\"1618\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1620\" data-end=\"2010\"\u003e• Detects flammable, toxic gases and oxygen levels\u003cbr data-start=\"1670\" data-end=\"1673\"\u003e• Supports catalytic, IR, and electrochemical sensors\u003cbr data-start=\"1726\" data-end=\"1729\"\u003e• 4–20 mA and Modbus RTU communication output\u003cbr data-start=\"1774\" data-end=\"1777\"\u003e• Integrated tri-color LCD status display\u003cbr data-start=\"1818\" data-end=\"1821\"\u003e• IP66 protection for industrial environments\u003cbr data-start=\"1866\" data-end=\"1869\"\u003e• Remote sensor mounting up to 30m\u003cbr data-start=\"1903\" data-end=\"1906\"\u003e• Three relay alarm outputs for safety control\u003cbr data-start=\"1952\" data-end=\"1955\"\u003e• Non-intrusive configuration using magnetic switches\u003c\/p\u003e\n\u003chr data-start=\"2012\" data-end=\"2015\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"2017\" data-end=\"2043\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2045\" data-end=\"2315\"\u003e\n\u003cli data-section-id=\"66hwpr\" data-start=\"2045\" data-end=\"2071\"\u003eOil and gas facilities\u003c\/li\u003e\n\u003cli data-section-id=\"6gyw6r\" data-start=\"2072\" data-end=\"2102\"\u003eChemical processing plants\u003c\/li\u003e\n\u003cli data-section-id=\"jerwvl\" data-start=\"2103\" data-end=\"2142\"\u003eRefineries and petrochemical plants\u003c\/li\u003e\n\u003cli data-section-id=\"nmhpvr\" data-start=\"2143\" data-end=\"2184\"\u003eWater and wastewater treatment plants\u003c\/li\u003e\n\u003cli data-section-id=\"1y4z0ss\" data-start=\"2185\" data-end=\"2224\"\u003eIndustrial manufacturing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"1qawct4\" data-start=\"2225\" data-end=\"2254\"\u003ePower generation stations\u003c\/li\u003e\n\u003cli data-section-id=\"7eslb9\" data-start=\"2255\" data-end=\"2277\"\u003eStorage tank areas\u003c\/li\u003e\n\u003cli data-section-id=\"102fmc\" data-start=\"2278\" data-end=\"2315\"\u003eConfined space monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2317\" data-end=\"2320\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2322\" data-end=\"2355\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2357\" data-end=\"2398\"\u003eBefore selecting Sensepoint XCD, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2400\" data-end=\"2761\"\u003e\n\u003cli data-section-id=\"f910ov\" data-start=\"2400\" data-end=\"2448\"\u003eTarget gas type (flammable \/ toxic \/ oxygen)\u003c\/li\u003e\n\u003cli data-section-id=\"1s0waxf\" data-start=\"2449\" data-end=\"2495\"\u003eDetection range (0–100% LEL, ppm, or % O₂)\u003c\/li\u003e\n\u003cli data-section-id=\"ybny0m\" data-start=\"2496\" data-end=\"2557\"\u003eInstallation environment (Zone 1 \/ Zone 2 hazardous area)\u003c\/li\u003e\n\u003cli data-section-id=\"422dib\" data-start=\"2558\" data-end=\"2626\"\u003eSensor technology requirement (IR \/ catalytic \/ electrochemical)\u003c\/li\u003e\n\u003cli data-section-id=\"1kjmhbt\" data-start=\"2627\" data-end=\"2665\"\u003eOutput type (4–20 mA \/ Modbus RTU)\u003c\/li\u003e\n\u003cli data-section-id=\"fcwkaz\" data-start=\"2666\" data-end=\"2722\"\u003eMounting location (local or remote sensor up to 30m)\u003c\/li\u003e\n\u003cli data-section-id=\"unr329\" data-start=\"2723\" data-end=\"2761\"\u003eRequired relay alarm configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2763\" data-end=\"2766\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2768\" data-end=\"2782\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2784\" data-end=\"2954\"\u003e\u003cstrong data-start=\"2784\" data-end=\"2833\"\u003eQ: What is Honeywell Sensepoint XCD used for?\u003c\/strong\u003e\u003cbr data-start=\"2833\" data-end=\"2836\"\u003eA: It is used for continuous monitoring of flammable gases, toxic gases, and oxygen levels in industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"2956\" data-end=\"3085\"\u003e\u003cstrong data-start=\"2956\" data-end=\"2988\"\u003eQ: What gases can it detect?\u003c\/strong\u003e\u003cbr data-start=\"2988\" data-end=\"2991\"\u003eA: It can detect combustible gases, toxic gases, and oxygen depending on sensor configuration.\u003c\/p\u003e\n\u003cp data-start=\"3087\" data-end=\"3204\"\u003e\u003cstrong data-start=\"3087\" data-end=\"3125\"\u003eQ: Does it support remote sensors?\u003c\/strong\u003e\u003cbr data-start=\"3125\" data-end=\"3128\"\u003eA: Yes, the sensor can be mounted up to 30 meters away from the transmitter.\u003c\/p\u003e\n\u003cp data-start=\"3206\" data-end=\"3325\"\u003e\u003cstrong data-start=\"3206\" data-end=\"3256\"\u003eQ: What communication outputs does it support?\u003c\/strong\u003e\u003cbr data-start=\"3256\" data-end=\"3259\"\u003eA: It supports 4–20 mA analog output and Modbus RTU communication.\u003c\/p\u003e\n\u003cp data-start=\"3327\" data-end=\"3444\"\u003e\u003cstrong data-start=\"3327\" data-end=\"3369\"\u003eQ: Is it suitable for hazardous areas?\u003c\/strong\u003e\u003cbr data-start=\"3369\" data-end=\"3372\"\u003eA: Yes, it is designed for Zone 1 and industrial hazardous environments.\u003c\/p\u003e\n\u003cp data-start=\"3446\" data-end=\"3578\"\u003e\u003cstrong data-start=\"3446\" data-end=\"3488\"\u003eQ: What industries use Sensepoint XCD?\u003c\/strong\u003e\u003cbr data-start=\"3488\" data-end=\"3491\"\u003eA: Oil \u0026amp; gas, chemical plants, refineries, power plants, and industrial safety systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43315716849725,"sku":null,"price":1300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/sensepoint-xcd-gas-detector-product-view.png?v=1782974813"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/collections\/7.png?v=1782963317","url":"https:\/\/proinstru.com\/collections\/honeywell.oembed","provider":"Process Instrument","version":"1.0","type":"link"}