{"title":"Endress+Hauser","description":"\u003cp data-start=\"120\" data-end=\"463\" class=\"PDq2pG_selectionAnchorContainer\"\u003eEndress+Hauser is a global leader in process automation and industrial measurement technology, specializing in high-precision instrumentation for level, flow, pressure, and temperature monitoring. Its solutions are widely used across industries such as oil \u0026amp; gas, chemical processing, water \u0026amp; wastewater, food \u0026amp; beverage, and power generation.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"465\" data-end=\"660\"\u003eKnown for accuracy, reliability, and advanced sensor technology, Endress+Hauser products help improve process safety, efficiency, and operational performance in demanding industrial environments.\u003c\/p\u003e","products":[{"product_id":"endress-hauser-smartec-cld18-conductivity-measurement-system","title":"Endress Hauser Smartec CLD18 Conductivity Measurement System","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"693\" data-start=\"669\" data-section-id=\"k5tk9i\"\u003eProduct Description\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-end=\"1010\" data-start=\"695\"\u003eThe \u003cstrong data-end=\"760\" data-start=\"699\"\u003eEndress+Hauser Smartec CLD18 Conductivity Measurement System\u003c\/strong\u003e is designed for accurate and reliable conductivity monitoring in hygienic process applications. Its compact design makes it suitable for installations where space is limited while maintaining stable performance in continuous production environments.\u003c\/p\u003e\n\u003cp data-end=\"1223\" data-start=\"1012\"\u003eBuilt for industries requiring efficient cleaning and process monitoring, the Smartec CLD18 supports conductivity measurement for product quality control, CIP process management, and liquid monitoring applications.\u003c\/p\u003e\n\u003cp data-end=\"1385\" data-start=\"1225\"\u003eIts hygienic design and reliable operation make it a practical choice for production systems where process stability and contamination prevention are important.\u003c\/p\u003e\n\u003cp data-end=\"1561\" data-start=\"1387\"\u003eGoogle SEO keywords naturally included: \u003cstrong data-end=\"1462\" data-start=\"1427\"\u003econductivity measurement system\u003c\/strong\u003e, \u003cstrong data-end=\"1487\" data-start=\"1464\"\u003econductivity sensor\u003c\/strong\u003e, \u003cstrong data-end=\"1520\" data-start=\"1489\"\u003eCIP conductivity monitoring\u003c\/strong\u003e, \u003cstrong data-end=\"1561\" data-start=\"1522\"\u003eindustrial conductivity transmitter\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-end=\"1566\" data-start=\"1563\"\u003e\n\u003ch1 data-end=\"1584\" data-start=\"1568\" data-section-id=\"1vrrhye\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-end=\"1983\" data-start=\"1586\"\u003e• Compact design for installations with limited space\u003cbr data-end=\"1642\" data-start=\"1639\"\u003e• Reliable conductivity monitoring for hygienic processes\u003cbr data-end=\"1702\" data-start=\"1699\"\u003e• Supports CIP process control and liquid monitoring\u003cbr data-end=\"1757\" data-start=\"1754\"\u003e• Stable measurement performance during continuous operation\u003cbr data-end=\"1820\" data-start=\"1817\"\u003e• Hygienic design helps reduce contamination risks\u003cbr data-end=\"1873\" data-start=\"1870\"\u003e• Easy integration into industrial process systems\u003cbr data-end=\"1926\" data-start=\"1923\"\u003e• Suitable for demanding food and beverage applications\u003c\/p\u003e\n\u003chr data-end=\"1988\" data-start=\"1985\"\u003e\n\u003ch1 data-end=\"2007\" data-start=\"1990\" data-section-id=\"18oyf1a\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-end=\"2268\" data-start=\"2009\"\u003e\n\u003cli data-end=\"2035\" data-start=\"2009\" data-section-id=\"t8sjlh\"\u003eCIP process monitoring\u003c\/li\u003e\n\u003cli data-end=\"2067\" data-start=\"2036\" data-section-id=\"10ti09k\"\u003eBeverage production systems\u003c\/li\u003e\n\u003cli data-end=\"2093\" data-start=\"2068\" data-section-id=\"1bfue0s\"\u003eFood processing lines\u003c\/li\u003e\n\u003cli data-end=\"2129\" data-start=\"2094\" data-section-id=\"1okylax\"\u003eLiquid concentration monitoring\u003c\/li\u003e\n\u003cli data-end=\"2172\" data-start=\"2130\" data-section-id=\"1sj70mg\"\u003eProduct and water separation processes\u003c\/li\u003e\n\u003cli data-end=\"2193\" data-start=\"2173\" data-section-id=\"1a3397j\"\u003eBottling systems\u003c\/li\u003e\n\u003cli data-end=\"2228\" data-start=\"2194\" data-section-id=\"5o6zou\"\u003eLeakage detection applications\u003c\/li\u003e\n\u003cli data-end=\"2268\" data-start=\"2229\" data-section-id=\"owo4p8\"\u003eIndustrial hygienic process systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2273\" data-start=\"2270\"\u003e\n\u003ch1 data-end=\"2295\" data-start=\"2275\" data-section-id=\"17qep6b\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-end=\"2334\" data-start=\"2297\"\u003eBefore selecting Smartec CLD18, confirm:\u003c\/p\u003e\n\u003cul data-end=\"2680\" data-start=\"2336\"\u003e\n\u003cli data-end=\"2379\" data-start=\"2336\" data-section-id=\"1rpoytn\"\u003eRequired conductivity measurement range\u003c\/li\u003e\n\u003cli data-end=\"2422\" data-start=\"2380\" data-section-id=\"1yaryxw\"\u003eMedium type and liquid characteristics\u003c\/li\u003e\n\u003cli data-end=\"2466\" data-start=\"2423\" data-section-id=\"3tw3fe\"\u003ePipe size and installation requirements\u003c\/li\u003e\n\u003cli data-end=\"2500\" data-start=\"2467\" data-section-id=\"1zw14h\"\u003eHygienic process requirements\u003c\/li\u003e\n\u003cli data-end=\"2548\" data-start=\"2501\" data-section-id=\"17lrozl\"\u003eProcess temperature and pressure conditions\u003c\/li\u003e\n\u003cli data-end=\"2619\" data-start=\"2549\" data-section-id=\"3pu8xv\"\u003eCommunication and output compatibility with PLC or control systems\u003c\/li\u003e\n\u003cli data-end=\"2680\" data-start=\"2620\" data-section-id=\"1kiaalc\"\u003eCleaning process requirements including CIP applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2685\" data-start=\"2682\"\u003e\n\u003ch1 data-end=\"2694\" data-start=\"2687\" data-section-id=\"1lxd8kj\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-end=\"2844\" data-start=\"2696\"\u003e\u003cstrong data-end=\"2739\" data-start=\"2696\"\u003eQ: What is the E+H Smartec CLD18 used for?\u003c\/strong\u003e\u003cbr data-end=\"2742\" data-start=\"2739\"\u003eA: It is used for conductivity measurement and process monitoring in hygienic industrial applications.\u003c\/p\u003e\n\u003cp data-end=\"3049\" data-start=\"2846\"\u003e\u003cstrong data-end=\"2895\" data-start=\"2846\"\u003eQ: Can it be used for CIP process monitoring?\u003c\/strong\u003e\u003cbr data-end=\"2898\" data-start=\"2895\"\u003eA: Yes. It is commonly used to monitor cleaning processes and liquid concentration control in production systems. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3242\" data-start=\"3051\"\u003e\u003cstrong data-end=\"3099\" data-start=\"3051\"\u003eQ: What industries commonly use this system?\u003c\/strong\u003e\u003cbr data-end=\"3102\" data-start=\"3099\"\u003eA: It is widely used in beverage production, food processing, and hygienic manufacturing environments. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3425\" data-start=\"3244\"\u003e\u003cstrong data-end=\"3292\" data-start=\"3244\"\u003eQ: Is it suitable for compact installations?\u003c\/strong\u003e\u003cbr data-end=\"3295\" data-start=\"3292\"\u003eA: Yes. Its compact design allows installation in applications with limited available space. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3615\" data-start=\"3427\"\u003e\u003cstrong data-end=\"3483\" data-start=\"3427\"\u003eQ: Can it integrate with industrial control systems?\u003c\/strong\u003e\u003cbr data-end=\"3486\" data-start=\"3483\"\u003eA: Yes. Configuration options may support integration with PLC and process control systems. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3807\" data-start=\"3617\"\u003e\u003cstrong data-end=\"3678\" data-start=\"3617\"\u003eQ: Why use conductivity monitoring in production systems?\u003c\/strong\u003e\u003cbr data-end=\"3681\" data-start=\"3678\"\u003eA: Conductivity measurement helps improve process consistency, monitor liquid conditions, and support product quality control.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311147778109,"sku":null,"price":1100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/cld18-conductivity-system-product-view.png?v=1782875980"},{"product_id":"endress-hauser-cerabar-pmc71b-pressure-transmitter","title":"Endress Hauser Cerabar PMC71B Pressure Transmitter","description":"\u003ch1 data-section-id=\"k5tk9i\" data-start=\"618\" data-end=\"642\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"644\" data-end=\"960\"\u003eThe \u003cstrong data-start=\"648\" data-end=\"702\"\u003eEndress+Hauser Cerabar PMC71B Pressure Transmitter\u003c\/strong\u003e is designed for reliable and accurate pressure monitoring in industrial process applications. Built with advanced sensing technology and a robust ceramic process diaphragm, it provides stable measurement performance even in demanding operating environments.\u003c\/p\u003e\n\u003cp data-start=\"962\" data-end=\"1233\"\u003eThe PMC71B supports continuous pressure monitoring across a wide range of applications where process accuracy and system reliability are essential. Its flexible configuration options allow integration into industrial automation systems for process control and monitoring.\u003c\/p\u003e\n\u003cp data-start=\"1235\" data-end=\"1482\"\u003eThe device is widely used in industries requiring dependable \u003cstrong data-start=\"1296\" data-end=\"1331\"\u003eindustrial pressure transmitter\u003c\/strong\u003e performance, including chemical processing, oil \u0026amp; gas operations, water treatment, and manufacturing facilities. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1484\" data-end=\"1655\"\u003eGoogle SEO keywords naturally included: \u003cstrong data-start=\"1524\" data-end=\"1548\"\u003epressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1550\" data-end=\"1580\"\u003eindustrial pressure sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1582\" data-end=\"1614\"\u003eprocess pressure measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1616\" data-end=\"1655\"\u003eEndress+Hauser pressure transmitter\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1657\" data-end=\"1660\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1662\" data-end=\"1678\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1680\" data-end=\"2060\"\u003e• High-accuracy industrial pressure measurement\u003cbr data-start=\"1727\" data-end=\"1730\"\u003e• Ceramic process diaphragm for demanding applications\u003cbr data-start=\"1784\" data-end=\"1787\"\u003e• Reliable performance in corrosive and vacuum conditions\u003cbr data-start=\"1844\" data-end=\"1847\"\u003e• Supports HART communication integration\u003cbr data-start=\"1888\" data-end=\"1891\"\u003e• Stable operation under changing process conditions\u003cbr data-start=\"1943\" data-end=\"1946\"\u003e• Multiple installation and configuration options\u003cbr data-start=\"1995\" data-end=\"1998\"\u003e• Suitable for continuous industrial monitoring environments\u003c\/p\u003e\n\u003chr data-start=\"2062\" data-end=\"2065\"\u003e\n\u003ch1 data-section-id=\"18oyf1a\" data-start=\"2067\" data-end=\"2084\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2086\" data-end=\"2342\"\u003e\n\u003cli data-section-id=\"180zpbe\" data-start=\"2086\" data-end=\"2117\"\u003eProcess pressure monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1gmems1\" data-start=\"2118\" data-end=\"2149\"\u003eChemical processing systems\u003c\/li\u003e\n\u003cli data-section-id=\"dufud4\" data-start=\"2150\" data-end=\"2176\"\u003eOil \u0026amp; gas applications\u003c\/li\u003e\n\u003cli data-section-id=\"hcl0oj\" data-start=\"2177\" data-end=\"2211\"\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"10q3r02\" data-start=\"2212\" data-end=\"2250\"\u003eIndustrial manufacturing processes\u003c\/li\u003e\n\u003cli data-section-id=\"18zzdpi\" data-start=\"2251\" data-end=\"2291\"\u003eTank and vessel pressure measurement\u003c\/li\u003e\n\u003cli data-section-id=\"d7taym\" data-start=\"2292\" data-end=\"2311\"\u003eUtility systems\u003c\/li\u003e\n\u003cli data-section-id=\"pdmsga\" data-start=\"2312\" data-end=\"2342\"\u003eProcess automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2344\" data-end=\"2347\"\u003e\n\u003ch1 data-section-id=\"17qep6b\" data-start=\"2349\" data-end=\"2369\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2371\" data-end=\"2404\"\u003eBefore selecting PMC71B, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2406\" data-end=\"2703\"\u003e\n\u003cli data-section-id=\"n5stmj\" data-start=\"2406\" data-end=\"2433\"\u003eRequired pressure range\u003c\/li\u003e\n\u003cli data-section-id=\"d39kk6\" data-start=\"2434\" data-end=\"2480\"\u003ePressure type (gauge, absolute, or vacuum)\u003c\/li\u003e\n\u003cli data-section-id=\"ztmafk\" data-start=\"2481\" data-end=\"2513\"\u003eProcess medium compatibility\u003c\/li\u003e\n\u003cli data-section-id=\"1lbu3lv\" data-start=\"2514\" data-end=\"2550\"\u003eProcess temperature requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1jy2ajr\" data-start=\"2551\" data-end=\"2604\"\u003eProcess connection type and mounting requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1x2syez\" data-start=\"2605\" data-end=\"2653\"\u003eOutput compatibility with PLC or DCS systems\u003c\/li\u003e\n\u003cli data-section-id=\"cshpwt\" data-start=\"2654\" data-end=\"2703\"\u003eEnvironmental and hazardous area requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2705\" data-end=\"2708\"\u003e\n\u003ch1 data-section-id=\"1lxd8kj\" data-start=\"2710\" data-end=\"2717\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2719\" data-end=\"2893\"\u003e\u003cstrong data-start=\"2719\" data-end=\"2766\"\u003eQ: What is the E+H Cerabar PMC71B used for?\u003c\/strong\u003e\u003cbr data-start=\"2766\" data-end=\"2769\"\u003eA: It is used for industrial pressure measurement and process monitoring applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2895\" data-end=\"3103\"\u003e\u003cstrong data-start=\"2895\" data-end=\"2950\"\u003eQ: What type of sensing technology does PMC71B use?\u003c\/strong\u003e\u003cbr data-start=\"2950\" data-end=\"2953\"\u003eA: The device uses a ceramic process diaphragm designed for stable measurement and reliable long-term operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3105\" data-end=\"3297\"\u003e\u003cstrong data-start=\"3105\" data-end=\"3156\"\u003eQ: Can PMC71B work with PLC or control systems?\u003c\/strong\u003e\u003cbr data-start=\"3156\" data-end=\"3159\"\u003eA: Yes. It supports integration with industrial process systems and HART communication environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3299\" data-end=\"3496\"\u003e\u003cstrong data-start=\"3299\" data-end=\"3348\"\u003eQ: Is it suitable for corrosive applications?\u003c\/strong\u003e\u003cbr data-start=\"3348\" data-end=\"3351\"\u003eA: Yes. The ceramic sensing technology is commonly selected for demanding and corrosive process conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3498\" data-end=\"3646\"\u003e\u003cstrong data-start=\"3498\" data-end=\"3541\"\u003eQ: What industries commonly use PMC71B?\u003c\/strong\u003e\u003cbr data-start=\"3541\" data-end=\"3544\"\u003eA: It is widely used in chemical processing, oil \u0026amp; gas, manufacturing, and water treatment industries.\u003c\/p\u003e\n\u003cp data-start=\"3648\" data-end=\"3838\"\u003e\u003cstrong data-start=\"3648\" data-end=\"3692\"\u003eQ: Does it support remote configuration?\u003c\/strong\u003e\u003cbr data-start=\"3692\" data-end=\"3695\"\u003eA: Depending on the selected configuration, communication and remote operation features may be available.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311154167869,"sku":null,"price":680.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/pmc71b-pressure-transmitter-product-view.png?v=1782876566"},{"product_id":"endress-hauser-css50d-conductivity-sensor","title":"Endress+Hauser CSS50D Conductivity Sensor","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"552\" data-end=\"588\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"590\" data-end=\"750\"\u003eThe \u003cstrong data-start=\"594\" data-end=\"639\"\u003eEndress+Hauser CSS50D Conductivity Sensor\u003c\/strong\u003e is designed for reliable and precise conductivity measurement in hygienic and industrial process applications.\u003c\/p\u003e\n\u003cp data-start=\"752\" data-end=\"935\"\u003eIt delivers stable measurement performance for process monitoring, liquid quality control, and cleaning process supervision in systems requiring high accuracy and long-term stability.\u003c\/p\u003e\n\u003cp data-start=\"937\" data-end=\"1130\"\u003eThe CSS50D is commonly used in industries where consistent conductivity measurement is critical for product quality and process safety, including food, beverage, and general process industries.\u003c\/p\u003e\n\u003cp data-start=\"1132\" data-end=\"1291\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1163\" data-end=\"1186\"\u003econductivity sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1188\" data-end=\"1216\"\u003econductivity measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1218\" data-end=\"1257\"\u003eindustrial conductivity transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1259\" data-end=\"1291\"\u003ehygienic conductivity sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1293\" data-end=\"1296\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1298\" data-end=\"1314\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1316\" data-end=\"1626\"\u003e• High-accuracy conductivity measurement\u003cbr data-start=\"1356\" data-end=\"1359\"\u003e• Stable performance in hygienic process environments\u003cbr data-start=\"1412\" data-end=\"1415\"\u003e• Suitable for continuous industrial monitoring\u003cbr data-start=\"1462\" data-end=\"1465\"\u003e• Reliable long-term measurement stability\u003cbr data-start=\"1507\" data-end=\"1510\"\u003e• Easy integration into process control systems\u003cbr data-start=\"1557\" data-end=\"1560\"\u003e• Low maintenance design\u003cbr data-start=\"1584\" data-end=\"1587\"\u003e• Optimized for industrial automation\u003c\/p\u003e\n\u003chr data-start=\"1628\" data-end=\"1631\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1633\" data-end=\"1659\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1661\" data-end=\"1921\"\u003e\n\u003cli data-section-id=\"1nq9ht9\" data-start=\"1661\" data-end=\"1696\"\u003eConductivity monitoring systems\u003c\/li\u003e\n\u003cli data-section-id=\"1j15hkx\" data-start=\"1697\" data-end=\"1728\"\u003eHygienic process industries\u003c\/li\u003e\n\u003cli data-section-id=\"1h1anvy\" data-start=\"1729\" data-end=\"1755\"\u003eLiquid quality control\u003c\/li\u003e\n\u003cli data-section-id=\"lehwno\" data-start=\"1756\" data-end=\"1797\"\u003eCleaning process (CIP\/SIP) monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1u082fb\" data-start=\"1798\" data-end=\"1830\"\u003eFood and beverage production\u003c\/li\u003e\n\u003cli data-section-id=\"1820j57\" data-start=\"1831\" data-end=\"1862\"\u003eChemical process monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1t3ua27\" data-start=\"1863\" data-end=\"1890\"\u003eWater treatment systems\u003c\/li\u003e\n\u003cli data-section-id=\"m89x5v\" data-start=\"1891\" data-end=\"1921\"\u003eIndustrial process control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1923\" data-end=\"1926\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"1928\" data-end=\"1961\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"1963\" data-end=\"1996\"\u003eBefore selecting CSS50D, confirm:\u003c\/p\u003e\n\u003cul data-start=\"1998\" data-end=\"2307\"\u003e\n\u003cli data-section-id=\"1rpoytn\" data-start=\"1998\" data-end=\"2041\"\u003eRequired conductivity measurement range\u003c\/li\u003e\n\u003cli data-section-id=\"m99tq3\" data-start=\"2042\" data-end=\"2103\"\u003eMedium type (clean water, process liquid, chemical media)\u003c\/li\u003e\n\u003cli data-section-id=\"t709r3\" data-start=\"2104\" data-end=\"2134\"\u003eHygienic requirement level\u003c\/li\u003e\n\u003cli data-section-id=\"1lemnbh\" data-start=\"2135\" data-end=\"2169\"\u003ePipe or tank installation type\u003c\/li\u003e\n\u003cli data-section-id=\"17lrozl\" data-start=\"2170\" data-end=\"2217\"\u003eProcess temperature and pressure conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1xigqo9\" data-start=\"2218\" data-end=\"2263\"\u003eOutput compatibility with PLC\/DCS systems\u003c\/li\u003e\n\u003cli data-section-id=\"ccfs4x\" data-start=\"2264\" data-end=\"2307\"\u003eCleaning and sterilization requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2309\" data-end=\"2312\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2314\" data-end=\"2328\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2330\" data-end=\"2485\"\u003e\u003cstrong data-start=\"2330\" data-end=\"2376\"\u003eQ: What is Endress+Hauser CSS50D used for?\u003c\/strong\u003e\u003cbr data-start=\"2376\" data-end=\"2379\"\u003eA: It is used for conductivity measurement and process monitoring in industrial and hygienic applications.\u003c\/p\u003e\n\u003cp data-start=\"2487\" data-end=\"2640\"\u003e\u003cstrong data-start=\"2487\" data-end=\"2539\"\u003eQ: Is CSS50D suitable for hygienic applications?\u003c\/strong\u003e\u003cbr data-start=\"2539\" data-end=\"2542\"\u003eA: Yes, it is designed for hygienic process environments requiring stable measurement performance.\u003c\/p\u003e\n\u003cp data-start=\"2642\" data-end=\"2760\"\u003e\u003cstrong data-start=\"2642\" data-end=\"2676\"\u003eQ: What industries use CSS50D?\u003c\/strong\u003e\u003cbr data-start=\"2676\" data-end=\"2679\"\u003eA: It is widely used in food, beverage, chemical, and water treatment industries.\u003c\/p\u003e\n\u003cp data-start=\"2762\" data-end=\"2892\"\u003e\u003cstrong data-start=\"2762\" data-end=\"2810\"\u003eQ: Can it be used for continuous monitoring?\u003c\/strong\u003e\u003cbr data-start=\"2810\" data-end=\"2813\"\u003eA: Yes, it supports continuous conductivity monitoring in industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"2894\" data-end=\"3014\"\u003e\u003cstrong data-start=\"2894\" data-end=\"2938\"\u003eQ: Does it require frequent maintenance?\u003c\/strong\u003e\u003cbr data-start=\"2938\" data-end=\"2941\"\u003eA: No, it is designed for low maintenance and long-term stable operation.\u003c\/p\u003e\n\u003cp data-start=\"3016\" data-end=\"3136\"\u003e\u003cstrong data-start=\"3016\" data-end=\"3057\"\u003eQ: Can it integrate with PLC systems?\u003c\/strong\u003e\u003cbr data-start=\"3057\" data-end=\"3060\"\u003eA: Yes, it can be integrated into industrial automation and control systems.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311232090173,"sku":null,"price":1370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/css50d-conductivity-sensor-product-view.png?v=1782878381"},{"product_id":"endress-hauser-liquiline-cm442-transmitter","title":"Endress+Hauser Liquiline CM442 Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"532\" data-end=\"568\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"570\" data-end=\"737\"\u003eThe \u003cstrong data-start=\"574\" data-end=\"620\"\u003eEndress+Hauser Liquiline CM442 Transmitter\u003c\/strong\u003e is a modular multiparameter field device designed for continuous liquid analysis in industrial process applications.\u003c\/p\u003e\n\u003cp data-start=\"739\" data-end=\"924\"\u003eIt supports multiple measurement parameters including pH, ORP, conductivity, oxygen, and other liquid analysis signals, making it a flexible solution for modern process control systems.\u003c\/p\u003e\n\u003cp data-start=\"926\" data-end=\"1162\"\u003eWith its expandable design and industrial communication capabilities, CM442 is widely used in water treatment, chemical processing, and general industrial automation where stable and reliable \u003cstrong data-start=\"1118\" data-end=\"1149\"\u003eliquid analysis measurement\u003c\/strong\u003e is required.\u003c\/p\u003e\n\u003cp data-start=\"1164\" data-end=\"1332\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1195\" data-end=\"1225\"\u003emultiparameter transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1227\" data-end=\"1253\"\u003eliquid analysis system\u003c\/strong\u003e, \u003cstrong data-start=\"1255\" data-end=\"1273\"\u003epH transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1275\" data-end=\"1306\"\u003eindustrial process analyzer\u003c\/strong\u003e, \u003cstrong data-start=\"1308\" data-end=\"1332\"\u003eEndress+Hauser CM442\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1334\" data-end=\"1337\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1339\" data-end=\"1355\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1357\" data-end=\"1739\"\u003e• Multiparameter liquid analysis platform\u003cbr data-start=\"1398\" data-end=\"1401\"\u003e• Supports pH, ORP, conductivity and more\u003cbr data-start=\"1442\" data-end=\"1445\"\u003e• Modular design with expandable functionality\u003cbr data-start=\"1491\" data-end=\"1494\"\u003e• Stable and reliable industrial performance\u003cbr data-start=\"1538\" data-end=\"1541\"\u003e• Easy integration into process control systems\u003cbr data-start=\"1588\" data-end=\"1591\"\u003e• Supports industrial communication protocols\u003cbr data-start=\"1636\" data-end=\"1639\"\u003e• Designed for continuous monitoring applications\u003cbr data-start=\"1688\" data-end=\"1691\"\u003e• Flexible configuration for different sensors\u003c\/p\u003e\n\u003chr data-start=\"1741\" data-end=\"1744\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1746\" data-end=\"1772\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1774\" data-end=\"2060\"\u003e\n\u003cli data-section-id=\"hcl0oj\" data-start=\"1774\" data-end=\"1808\"\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"1820j57\" data-start=\"1809\" data-end=\"1840\"\u003eChemical process monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1u082fb\" data-start=\"1841\" data-end=\"1873\"\u003eFood and beverage production\u003c\/li\u003e\n\u003cli data-section-id=\"16f47vv\" data-start=\"1874\" data-end=\"1919\"\u003ePharmaceutical and life science processes\u003c\/li\u003e\n\u003cli data-section-id=\"11rynon\" data-start=\"1920\" data-end=\"1958\"\u003eIndustrial liquid analysis systems\u003c\/li\u003e\n\u003cli data-section-id=\"1l9ayu6\" data-start=\"1959\" data-end=\"1987\"\u003eCooling water monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"pdmsga\" data-start=\"1988\" data-end=\"2018\"\u003eProcess automation systems\u003c\/li\u003e\n\u003cli data-section-id=\"19zli51\" data-start=\"2019\" data-end=\"2060\"\u003eEnvironmental monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2062\" data-end=\"2065\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2067\" data-end=\"2100\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2102\" data-end=\"2134\"\u003eBefore selecting CM442, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2136\" data-end=\"2511\"\u003e\n\u003cli data-section-id=\"8hl296\" data-start=\"2136\" data-end=\"2201\"\u003eRequired measurement parameters (pH, ORP, conductivity, etc.)\u003c\/li\u003e\n\u003cli data-section-id=\"14cz41s\" data-start=\"2202\" data-end=\"2256\"\u003eNumber of sensor channels needed (1 or 2 channels)\u003c\/li\u003e\n\u003cli data-section-id=\"1rpm149\" data-start=\"2257\" data-end=\"2330\"\u003eCommunication protocol requirements (HART, Modbus, Ethernet\/IP, etc.)\u003c\/li\u003e\n\u003cli data-section-id=\"a96eza\" data-start=\"2331\" data-end=\"2365\"\u003eProcess environment conditions\u003c\/li\u003e\n\u003cli data-section-id=\"ev2huv\" data-start=\"2366\" data-end=\"2411\"\u003eSensor compatibility (Memosens or analog)\u003c\/li\u003e\n\u003cli data-section-id=\"udujzd\" data-start=\"2412\" data-end=\"2461\"\u003eInstallation type (field or cabinet mounting)\u003c\/li\u003e\n\u003cli data-section-id=\"17am4ui\" data-start=\"2462\" data-end=\"2511\"\u003eIntegration requirements with PLC\/DCS systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2513\" data-end=\"2516\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2518\" data-end=\"2532\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2534\" data-end=\"2681\"\u003e\u003cstrong data-start=\"2534\" data-end=\"2583\"\u003eQ: What is the Endress+Hauser CM442 used for?\u003c\/strong\u003e\u003cbr data-start=\"2583\" data-end=\"2586\"\u003eA: It is used for multiparameter liquid analysis in industrial process monitoring applications.\u003c\/p\u003e\n\u003cp data-start=\"2683\" data-end=\"2830\"\u003e\u003cstrong data-start=\"2683\" data-end=\"2725\"\u003eQ: Which parameters can CM442 measure?\u003c\/strong\u003e\u003cbr data-start=\"2725\" data-end=\"2728\"\u003eA: It can be used with sensors for pH, ORP, conductivity, oxygen and other liquid analysis parameters.\u003c\/p\u003e\n\u003cp data-start=\"2832\" data-end=\"2957\"\u003e\u003cstrong data-start=\"2832\" data-end=\"2874\"\u003eQ: How many sensors can CM442 support?\u003c\/strong\u003e\u003cbr data-start=\"2874\" data-end=\"2877\"\u003eA: It supports up to 1 or 2 Memosens digital sensors depending on configuration.\u003c\/p\u003e\n\u003cp data-start=\"2959\" data-end=\"3115\"\u003e\u003cstrong data-start=\"2959\" data-end=\"3018\"\u003eQ: Is CM442 suitable for industrial automation systems?\u003c\/strong\u003e\u003cbr data-start=\"3018\" data-end=\"3021\"\u003eA: Yes, it supports multiple communication protocols for integration into PLC and DCS systems.\u003c\/p\u003e\n\u003cp data-start=\"3117\" data-end=\"3273\"\u003e\u003cstrong data-start=\"3117\" data-end=\"3160\"\u003eQ: What industries use Liquiline CM442?\u003c\/strong\u003e\u003cbr data-start=\"3160\" data-end=\"3163\"\u003eA: It is widely used in water treatment, chemical processing, food and beverage, and industrial manufacturing.\u003c\/p\u003e\n\u003cp data-start=\"3275\" data-end=\"3421\"\u003e\u003cstrong data-start=\"3275\" data-end=\"3316\"\u003eQ: Does it support modular expansion?\u003c\/strong\u003e\u003cbr data-start=\"3316\" data-end=\"3319\"\u003eA: Yes, the system is modular and can be expanded with additional functions and communication modules.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311521005629,"sku":null,"price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/cm442-multiparameter-transmitter-product-view.png?v=1782887482"},{"product_id":"endress-hauser-proline-promag-d-10-flowmeter-5dbb","title":"Endress+Hauser Proline Promag D 10 Flowmeter 5DBB-","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"528\" data-end=\"564\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"566\" data-end=\"732\"\u003eThe \u003cstrong data-start=\"570\" data-end=\"618\"\u003eEndress+Hauser Proline Promag D 10 Flowmeter\u003c\/strong\u003e is a cost-effective electromagnetic flowmeter designed for basic water and utility flow measurement applications.\u003c\/p\u003e\n\u003cp data-start=\"734\" data-end=\"918\"\u003eIt provides reliable and stable volume flow measurement with a compact wafer-style design, making it suitable for installations where space is limited and cost efficiency is important.\u003c\/p\u003e\n\u003cp data-start=\"920\" data-end=\"1126\"\u003eThe Promag D 10 is widely used in water distribution, utility systems, and general industrial applications where accurate \u003cstrong data-start=\"1042\" data-end=\"1078\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e is required for process monitoring and control.\u003c\/p\u003e\n\u003cp data-start=\"1128\" data-end=\"1274\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1159\" data-end=\"1188\"\u003eelectromagnetic flowmeter\u003c\/strong\u003e, \u003cstrong data-start=\"1190\" data-end=\"1216\"\u003ewater flow measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1218\" data-end=\"1244\"\u003eindustrial flow sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1246\" data-end=\"1274\"\u003eEndress+Hauser flowmeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1276\" data-end=\"1279\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1281\" data-end=\"1297\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1299\" data-end=\"1675\"\u003e• Cost-effective electromagnetic flow measurement\u003cbr data-start=\"1348\" data-end=\"1351\"\u003e• Suitable for basic water applications\u003cbr data-start=\"1390\" data-end=\"1393\"\u003e• Compact wafer-style installation design\u003cbr data-start=\"1434\" data-end=\"1437\"\u003e• Maintenance-free operation with no moving parts\u003cbr data-start=\"1486\" data-end=\"1489\"\u003e• Stable and reliable flow reading performance\u003cbr data-start=\"1535\" data-end=\"1538\"\u003e• Easy installation and commissioning\u003cbr data-start=\"1575\" data-end=\"1578\"\u003e• Integrated diagnostic and verification functions\u003cbr data-start=\"1628\" data-end=\"1631\"\u003e• Industrial-grade measurement reliability\u003c\/p\u003e\n\u003chr data-start=\"1677\" data-end=\"1680\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1682\" data-end=\"1708\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1710\" data-end=\"1962\"\u003e\n\u003cli data-section-id=\"wbqg1d\" data-start=\"1710\" data-end=\"1740\"\u003eWater distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1l8to4r\" data-start=\"1741\" data-end=\"1770\"\u003eDrinking water monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"3a4m9u\" data-start=\"1771\" data-end=\"1816\"\u003eIndustrial utility water flow measurement\u003c\/li\u003e\n\u003cli data-section-id=\"2bp7yc\" data-start=\"1817\" data-end=\"1842\"\u003eCooling water systems\u003c\/li\u003e\n\u003cli data-section-id=\"1ts7iec\" data-start=\"1843\" data-end=\"1865\"\u003eIrrigation systems\u003c\/li\u003e\n\u003cli data-section-id=\"1frnop8\" data-start=\"1866\" data-end=\"1902\"\u003eGeneral process water monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"gpou55\" data-start=\"1903\" data-end=\"1923\"\u003ePumping stations\u003c\/li\u003e\n\u003cli data-section-id=\"1me6cwe\" data-start=\"1924\" data-end=\"1962\"\u003eBasic industrial flow applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1964\" data-end=\"1967\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"1969\" data-end=\"2002\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2004\" data-end=\"2042\"\u003eBefore selecting Promag D 10, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2044\" data-end=\"2336\"\u003e\n\u003cli data-section-id=\"fid98x\" data-start=\"2044\" data-end=\"2084\"\u003ePipe size and DN range compatibility\u003c\/li\u003e\n\u003cli data-section-id=\"1daeri7\" data-start=\"2085\" data-end=\"2131\"\u003eMedium type (clean water or process water)\u003c\/li\u003e\n\u003cli data-section-id=\"66nm18\" data-start=\"2132\" data-end=\"2155\"\u003eRequired flow range\u003c\/li\u003e\n\u003cli data-section-id=\"di5fxk\" data-start=\"2156\" data-end=\"2209\"\u003eInstallation space and wafer mounting suitability\u003c\/li\u003e\n\u003cli data-section-id=\"1mocoiy\" data-start=\"2210\" data-end=\"2249\"\u003ePressure and temperature conditions\u003c\/li\u003e\n\u003cli data-section-id=\"6hk2kg\" data-start=\"2250\" data-end=\"2306\"\u003eOutput signal requirements (4–20 mA \/ HART \/ Modbus)\u003c\/li\u003e\n\u003cli data-section-id=\"yx319x\" data-start=\"2307\" data-end=\"2336\"\u003ePower supply availability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2338\" data-end=\"2341\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2343\" data-end=\"2357\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2359\" data-end=\"2504\"\u003e\u003cstrong data-start=\"2359\" data-end=\"2410\"\u003eQ: What is Endress+Hauser Promag D 10 used for?\u003c\/strong\u003e\u003cbr data-start=\"2410\" data-end=\"2413\"\u003eA: It is used for electromagnetic flow measurement in basic water and utility applications.\u003c\/p\u003e\n\u003cp data-start=\"2506\" data-end=\"2636\"\u003e\u003cstrong data-start=\"2506\" data-end=\"2556\"\u003eQ: Is Promag D 10 suitable for drinking water?\u003c\/strong\u003e\u003cbr data-start=\"2556\" data-end=\"2559\"\u003eA: Yes, it is commonly used in water distribution and drinking water systems.\u003c\/p\u003e\n\u003cp data-start=\"2638\" data-end=\"2737\"\u003e\u003cstrong data-start=\"2638\" data-end=\"2673\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-start=\"2673\" data-end=\"2676\"\u003eA: No, it has a maintenance-free design with no moving parts.\u003c\/p\u003e\n\u003cp data-start=\"2739\" data-end=\"2851\"\u003e\u003cstrong data-start=\"2739\" data-end=\"2773\"\u003eQ: What principle does it use?\u003c\/strong\u003e\u003cbr data-start=\"2773\" data-end=\"2776\"\u003eA: It uses electromagnetic induction to measure flow of conductive liquids.\u003c\/p\u003e\n\u003cp data-start=\"2853\" data-end=\"2981\"\u003e\u003cstrong data-start=\"2853\" data-end=\"2892\"\u003eQ: What industries use Promag D 10?\u003c\/strong\u003e\u003cbr data-start=\"2892\" data-end=\"2895\"\u003eA: It is used in water treatment, utilities, irrigation, and industrial water systems.\u003c\/p\u003e\n\u003cp data-start=\"2983\" data-end=\"3136\"\u003e\u003cstrong data-start=\"2983\" data-end=\"3046\"\u003eQ: Is it suitable for high-precision chemical applications?\u003c\/strong\u003e\u003cbr data-start=\"3046\" data-end=\"3049\"\u003eA: No, it is designed for basic water applications, not high-precision chemical dosing.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311526936637,"sku":null,"price":1380.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-d10-flowmeter-product-view.png?v=1782887857"},{"product_id":"endress-hauser-proline-promag-h-100-electromagnetic-flowmeter-5h1b","title":"Endress+Hauser Proline Promag H 100 Electromagnetic Flowmeter 5H1B-","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"547\" data-end=\"583\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"585\" data-end=\"769\"\u003eThe \u003cstrong data-start=\"589\" data-end=\"645\"\u003eEndress+Hauser Proline Promag H 100 (5H1B) Flowmeter\u003c\/strong\u003e is a compact electromagnetic flowmeter designed for hygienic applications requiring high accuracy and reliable performance.\u003c\/p\u003e\n\u003cp data-start=\"771\" data-end=\"931\"\u003eIt is widely used in food, beverage, and life science industries where precise \u003cstrong data-start=\"850\" data-end=\"886\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e is required under strict hygienic standards.\u003c\/p\u003e\n\u003cp data-start=\"933\" data-end=\"1202\"\u003eWith its ultra-compact transmitter design, the Promag H 100 enables easy system integration while maintaining full measurement performance. It supports stable flow monitoring even under varying process conditions such as pressure, temperature, and conductivity changes.\u003c\/p\u003e\n\u003cp data-start=\"1204\" data-end=\"1378\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1235\" data-end=\"1264\"\u003eelectromagnetic flowmeter\u003c\/strong\u003e, \u003cstrong data-start=\"1266\" data-end=\"1288\"\u003ehygienic flowmeter\u003c\/strong\u003e, \u003cstrong data-start=\"1290\" data-end=\"1316\"\u003ewater flow measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1318\" data-end=\"1348\"\u003eEndress+Hauser flow sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1350\" data-end=\"1378\"\u003eprocess flow transmitter\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1380\" data-end=\"1383\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1385\" data-end=\"1401\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1403\" data-end=\"1778\"\u003e• Electromagnetic flow measurement technology\u003cbr data-start=\"1448\" data-end=\"1451\"\u003e• Designed for hygienic process applications\u003cbr data-start=\"1495\" data-end=\"1498\"\u003e• Ultra-compact transmitter for easy installation\u003cbr data-start=\"1547\" data-end=\"1550\"\u003e• Maintenance-free design with no moving parts\u003cbr data-start=\"1596\" data-end=\"1599\"\u003e• High measurement accuracy and stability\u003cbr data-start=\"1640\" data-end=\"1643\"\u003e• Supports CIP\/SIP cleaning processes\u003cbr data-start=\"1680\" data-end=\"1683\"\u003e• Integrated diagnostics and Heartbeat Technology\u003cbr data-start=\"1732\" data-end=\"1735\"\u003e• Suitable for compact system integration\u003c\/p\u003e\n\u003chr data-start=\"1780\" data-end=\"1783\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1785\" data-end=\"1811\"\u003e Applications\u003c\/h1\u003e\n\u003cul data-start=\"1813\" data-end=\"2085\"\u003e\n\u003cli data-section-id=\"1u082fb\" data-start=\"1813\" data-end=\"1845\"\u003eFood and beverage production\u003c\/li\u003e\n\u003cli data-section-id=\"1cw5vd6\" data-start=\"1846\" data-end=\"1892\"\u003ePharmaceutical and life science industries\u003c\/li\u003e\n\u003cli data-section-id=\"75a3mz\" data-start=\"1893\" data-end=\"1921\"\u003eHygienic process systems\u003c\/li\u003e\n\u003cli data-section-id=\"ozn7ba\" data-start=\"1922\" data-end=\"1956\"\u003eWater-based process monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1jud3hg\" data-start=\"1957\" data-end=\"1985\"\u003eCIP\/SIP cleaning systems\u003c\/li\u003e\n\u003cli data-section-id=\"1tgr8jf\" data-start=\"1986\" data-end=\"2024\"\u003eIndustrial liquid flow measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1lcfxnl\" data-start=\"2025\" data-end=\"2057\"\u003eSkid-mounted process systems\u003c\/li\u003e\n\u003cli data-section-id=\"1mhwjg6\" data-start=\"2058\" data-end=\"2085\"\u003eUtility flow monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2087\" data-end=\"2090\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2092\" data-end=\"2125\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2127\" data-end=\"2166\"\u003eBefore selecting Promag H 100, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2168\" data-end=\"2474\"\u003e\n\u003cli data-section-id=\"1i5hotm\" data-start=\"2168\" data-end=\"2204\"\u003ePipe size (DN range requirement)\u003c\/li\u003e\n\u003cli data-section-id=\"1hvo8j7\" data-start=\"2205\" data-end=\"2240\"\u003eMedium conductivity suitability\u003c\/li\u003e\n\u003cli data-section-id=\"1ta8rmc\" data-start=\"2241\" data-end=\"2279\"\u003eHygienic process requirement level\u003c\/li\u003e\n\u003cli data-section-id=\"evuou6\" data-start=\"2280\" data-end=\"2322\"\u003eProcess temperature and pressure range\u003c\/li\u003e\n\u003cli data-section-id=\"1m3x82s\" data-start=\"2323\" data-end=\"2381\"\u003eOutput signal requirements (4–20 mA \/ HART \/ fieldbus)\u003c\/li\u003e\n\u003cli data-section-id=\"ytg2i3\" data-start=\"2382\" data-end=\"2416\"\u003eInstallation space limitations\u003c\/li\u003e\n\u003cli data-section-id=\"xl72ca\" data-start=\"2417\" data-end=\"2474\"\u003eCleaning process requirements (CIP\/SIP compatibility)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2476\" data-end=\"2479\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2481\" data-end=\"2495\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2497\" data-end=\"2639\"\u003e\u003cstrong data-start=\"2497\" data-end=\"2549\"\u003eQ: What is Endress+Hauser Promag H 100 used for?\u003c\/strong\u003e\u003cbr data-start=\"2549\" data-end=\"2552\"\u003eA: It is used for electromagnetic flow measurement in hygienic industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"2641\" data-end=\"2768\"\u003e\u003cstrong data-start=\"2641\" data-end=\"2681\"\u003eQ: What industries use Promag H 100?\u003c\/strong\u003e\u003cbr data-start=\"2681\" data-end=\"2684\"\u003eA: It is widely used in food, beverage, pharmaceutical, and life science industries.\u003c\/p\u003e\n\u003cp data-start=\"2770\" data-end=\"2914\"\u003e\u003cstrong data-start=\"2770\" data-end=\"2828\"\u003eQ: Is Promag H 100 suitable for hygienic applications?\u003c\/strong\u003e\u003cbr data-start=\"2828\" data-end=\"2831\"\u003eA: Yes, it is specifically designed for hygienic and sanitary process requirements.\u003c\/p\u003e\n\u003cp data-start=\"2916\" data-end=\"3018\"\u003e\u003cstrong data-start=\"2916\" data-end=\"2951\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-start=\"2951\" data-end=\"2954\"\u003eA: No, it is maintenance-free due to its non-moving-part design.\u003c\/p\u003e\n\u003cp data-start=\"3020\" data-end=\"3126\"\u003e\u003cstrong data-start=\"3020\" data-end=\"3058\"\u003eQ: Can it handle CIP\/SIP cleaning?\u003c\/strong\u003e\u003cbr data-start=\"3058\" data-end=\"3061\"\u003eA: Yes, it is designed to support CIP and SIP cleaning processes.\u003c\/p\u003e\n\u003cp data-start=\"3128\" data-end=\"3256\"\u003e\u003cstrong data-start=\"3128\" data-end=\"3174\"\u003eQ: What measurement principle does it use?\u003c\/strong\u003e\u003cbr data-start=\"3174\" data-end=\"3177\"\u003eA: It uses electromagnetic induction to measure the flow of conductive liquids.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311551217725,"sku":null,"price":2420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-h100-5h1b-flowmeter-product-view.png?v=1782888195"},{"product_id":"endress-hauser-proline-promag-p-300-electromagnetic-flowmeter-5p3b","title":"Endress+Hauser Proline Promag P 300 Electromagnetic Flowmeter 5P3B-","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"607\" data-end=\"643\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"645\" data-end=\"862\"\u003eThe \u003cstrong data-start=\"649\" data-end=\"698\"\u003eEndress+Hauser Proline Promag P 300 Flowmeter\u003c\/strong\u003e is a high-performance electromagnetic flowmeter designed for demanding chemical and process applications involving corrosive liquids and high process temperatures.\u003c\/p\u003e\n\u003cp data-start=\"864\" data-end=\"1047\"\u003eIt delivers reliable and maintenance-free flow measurement based on electromagnetic induction, making it ideal for continuous monitoring of conductive liquids in industrial pipelines.\u003c\/p\u003e\n\u003cp data-start=\"1049\" data-end=\"1264\"\u003eThe Promag P 300 supports advanced diagnostics and flexible system integration, allowing seamless connection to modern automation systems while ensuring long-term measurement stability in harsh operating conditions.\u003c\/p\u003e\n\u003cp data-start=\"1266\" data-end=\"1446\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1297\" data-end=\"1326\"\u003eelectromagnetic flowmeter\u003c\/strong\u003e, \u003cstrong data-start=\"1328\" data-end=\"1353\"\u003eindustrial flow meter\u003c\/strong\u003e, \u003cstrong data-start=\"1355\" data-end=\"1384\"\u003echemical flow measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1386\" data-end=\"1416\"\u003eEndress+Hauser flow sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1418\" data-end=\"1446\"\u003eprocess flow transmitter\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1448\" data-end=\"1451\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1453\" data-end=\"1469\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1471\" data-end=\"1860\"\u003e• Electromagnetic flow measurement technology\u003cbr data-start=\"1516\" data-end=\"1519\"\u003e• Designed for corrosive and high-temperature media\u003cbr data-start=\"1570\" data-end=\"1573\"\u003e• Maintenance-free design with no moving parts\u003cbr data-start=\"1619\" data-end=\"1622\"\u003e• High measurement accuracy and stability\u003cbr data-start=\"1663\" data-end=\"1666\"\u003e• Compact transmitter with flexible installation\u003cbr data-start=\"1714\" data-end=\"1717\"\u003e• Advanced diagnostics and Heartbeat Technology\u003cbr data-start=\"1764\" data-end=\"1767\"\u003e• Suitable for chemical and process industries\u003cbr data-start=\"1813\" data-end=\"1816\"\u003e• Easy integration into automation systems\u003c\/p\u003e\n\u003chr data-start=\"1862\" data-end=\"1865\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1867\" data-end=\"1893\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1895\" data-end=\"2179\"\u003e\n\u003cli data-section-id=\"1gmems1\" data-start=\"1895\" data-end=\"1926\"\u003eChemical processing systems\u003c\/li\u003e\n\u003cli data-section-id=\"1xc1wxi\" data-start=\"1927\" data-end=\"1964\"\u003eCorrosive liquid flow measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1b6xjet\" data-start=\"1965\" data-end=\"2006\"\u003eHigh-temperature process applications\u003c\/li\u003e\n\u003cli data-section-id=\"xmb7p7\" data-start=\"2007\" data-end=\"2042\"\u003eIndustrial manufacturing plants\u003c\/li\u003e\n\u003cli data-section-id=\"hcl0oj\" data-start=\"2043\" data-end=\"2077\"\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"1ku1kop\" data-start=\"2078\" data-end=\"2111\"\u003eUtility and process pipelines\u003c\/li\u003e\n\u003cli data-section-id=\"1sm2t9j\" data-start=\"2112\" data-end=\"2140\"\u003ePower generation systems\u003c\/li\u003e\n\u003cli data-section-id=\"srn18n\" data-start=\"2141\" data-end=\"2179\"\u003eGeneral industrial flow monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2181\" data-end=\"2184\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2186\" data-end=\"2219\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2221\" data-end=\"2260\"\u003eBefore selecting Promag P 300, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2262\" data-end=\"2585\"\u003e\n\u003cli data-section-id=\"1i5hotm\" data-start=\"2262\" data-end=\"2298\"\u003ePipe size (DN range requirement)\u003c\/li\u003e\n\u003cli data-section-id=\"1hvo8j7\" data-start=\"2299\" data-end=\"2334\"\u003eMedium conductivity suitability\u003c\/li\u003e\n\u003cli data-section-id=\"uhjob1\" data-start=\"2335\" data-end=\"2372\"\u003eCorrosive resistance requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1yexrsq\" data-start=\"2373\" data-end=\"2434\"\u003eProcess temperature range (high temperature applications)\u003c\/li\u003e\n\u003cli data-section-id=\"1c8ckpy\" data-start=\"2435\" data-end=\"2467\"\u003ePressure rating requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1xxwmpq\" data-start=\"2468\" data-end=\"2537\"\u003eOutput communication protocol (HART, Profibus, Ethernet\/IP, etc.)\u003c\/li\u003e\n\u003cli data-section-id=\"qzw1ci\" data-start=\"2538\" data-end=\"2585\"\u003eInstallation space and flange compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2587\" data-end=\"2590\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2592\" data-end=\"2606\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2608\" data-end=\"2771\"\u003e\u003cstrong data-start=\"2608\" data-end=\"2660\"\u003eQ: What is Endress+Hauser Promag P 300 used for?\u003c\/strong\u003e\u003cbr data-start=\"2660\" data-end=\"2663\"\u003eA: It is used for electromagnetic flow measurement in chemical and high-temperature industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"2773\" data-end=\"2909\"\u003e\u003cstrong data-start=\"2773\" data-end=\"2827\"\u003eQ: Is Promag P 300 suitable for corrosive liquids?\u003c\/strong\u003e\u003cbr data-start=\"2827\" data-end=\"2830\"\u003eA: Yes, it is specifically designed for corrosive and aggressive process media.\u003c\/p\u003e\n\u003cp data-start=\"2911\" data-end=\"3013\"\u003e\u003cstrong data-start=\"2911\" data-end=\"2946\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-start=\"2946\" data-end=\"2949\"\u003eA: No, it is maintenance-free due to its non-moving-part design.\u003c\/p\u003e\n\u003cp data-start=\"3015\" data-end=\"3139\"\u003e\u003cstrong data-start=\"3015\" data-end=\"3061\"\u003eQ: What measurement principle does it use?\u003c\/strong\u003e\u003cbr data-start=\"3061\" data-end=\"3064\"\u003eA: It uses electromagnetic induction to measure flow of conductive liquids.\u003c\/p\u003e\n\u003cp data-start=\"3141\" data-end=\"3276\"\u003e\u003cstrong data-start=\"3141\" data-end=\"3181\"\u003eQ: What industries use Promag P 300?\u003c\/strong\u003e\u003cbr data-start=\"3181\" data-end=\"3184\"\u003eA: It is widely used in chemical processing, power generation, and industrial manufacturing.\u003c\/p\u003e\n\u003cp data-start=\"3278\" data-end=\"3413\"\u003e\u003cstrong data-start=\"3278\" data-end=\"3319\"\u003eQ: Can it integrate with PLC systems?\u003c\/strong\u003e\u003cbr data-start=\"3319\" data-end=\"3322\"\u003eA: Yes, it supports multiple industrial communication protocols for automation integration.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311583887421,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-p300-flowmeter-product-view.png?v=1782889116"},{"product_id":"endress-hauser-proline-promag-w-10-electromagnetic-flowmeter-5wbb","title":"Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter 5WBB-","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"609\" data-end=\"645\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"647\" data-end=\"840\" class=\"\"\u003eThe \u003cstrong data-start=\"651\" data-end=\"699\"\u003eEndress+Hauser Proline Promag W 10 Flowmeter\u003c\/strong\u003e is an electromagnetic flowmeter designed for basic water and wastewater applications requiring reliable and cost-efficient flow measurement.\u003c\/p\u003e\n\u003cp data-start=\"842\" data-end=\"1048\"\u003eIt provides stable volumetric flow measurement of conductive liquids using electromagnetic induction technology, ensuring accurate performance without moving parts and with minimal maintenance requirements.\u003c\/p\u003e\n\u003cp data-start=\"1050\" data-end=\"1268\"\u003eThe Promag W 10 is widely used in water supply systems, wastewater treatment, and utility flow monitoring where dependable \u003cstrong data-start=\"1173\" data-end=\"1209\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e is required for operational control and system efficiency.\u003c\/p\u003e\n\u003cp data-start=\"1270\" data-end=\"1450\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1301\" data-end=\"1330\"\u003eelectromagnetic flowmeter\u003c\/strong\u003e, \u003cstrong data-start=\"1332\" data-end=\"1352\"\u003ewater flow meter\u003c\/strong\u003e, \u003cstrong data-start=\"1354\" data-end=\"1385\"\u003ewastewater flow measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1387\" data-end=\"1417\"\u003eEndress+Hauser flow sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1419\" data-end=\"1450\"\u003eindustrial flow measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1452\" data-end=\"1455\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1457\" data-end=\"1473\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1475\" data-end=\"1882\"\u003e• Electromagnetic flow measurement technology\u003cbr data-start=\"1520\" data-end=\"1523\"\u003e• Designed for water and wastewater applications\u003cbr data-start=\"1571\" data-end=\"1574\"\u003e• Maintenance-free design with no moving parts\u003cbr data-start=\"1620\" data-end=\"1623\"\u003e• High measurement reliability and stability\u003cbr data-start=\"1667\" data-end=\"1670\"\u003e• Compact and cost-effective solution\u003cbr data-start=\"1707\" data-end=\"1710\"\u003e• IP68 protection for harsh environments\u003cbr data-start=\"1750\" data-end=\"1753\"\u003e• Easy installation and commissioning\u003cbr data-start=\"1790\" data-end=\"1793\"\u003e• Integrated diagnostics and Heartbeat Technology \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1884\" data-end=\"1887\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1889\" data-end=\"1915\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1917\" data-end=\"2150\"\u003e\n\u003cli data-section-id=\"wbqg1d\" data-start=\"1917\" data-end=\"1947\"\u003eWater distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1cbb0k9\" data-start=\"1948\" data-end=\"1979\"\u003eWastewater treatment plants\u003c\/li\u003e\n\u003cli data-section-id=\"1l8to4r\" data-start=\"1980\" data-end=\"2009\"\u003eDrinking water monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"175f8wg\" data-start=\"2010\" data-end=\"2038\"\u003eUtility flow measurement\u003c\/li\u003e\n\u003cli data-section-id=\"gpou55\" data-start=\"2039\" data-end=\"2059\"\u003ePumping stations\u003c\/li\u003e\n\u003cli data-section-id=\"1ts7iec\" data-start=\"2060\" data-end=\"2082\"\u003eIrrigation systems\u003c\/li\u003e\n\u003cli data-section-id=\"2bp7yc\" data-start=\"2083\" data-end=\"2108\"\u003eCooling water systems\u003c\/li\u003e\n\u003cli data-section-id=\"92aa79\" data-start=\"2109\" data-end=\"2150\"\u003eGeneral industrial water applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2152\" data-end=\"2155\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2157\" data-end=\"2190\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2192\" data-end=\"2230\"\u003eBefore selecting Promag W 10, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2232\" data-end=\"2535\"\u003e\n\u003cli data-section-id=\"1i5hotm\" data-start=\"2232\" data-end=\"2268\"\u003ePipe size (DN range requirement)\u003c\/li\u003e\n\u003cli data-section-id=\"1hvo8j7\" data-start=\"2269\" data-end=\"2304\"\u003eMedium conductivity suitability\u003c\/li\u003e\n\u003cli data-section-id=\"mc68lf\" data-start=\"2305\" data-end=\"2345\"\u003eWater or wastewater application type\u003c\/li\u003e\n\u003cli data-section-id=\"526zko\" data-start=\"2346\" data-end=\"2405\"\u003eInstallation environment (buried, underground, outdoor)\u003c\/li\u003e\n\u003cli data-section-id=\"1mypmdq\" data-start=\"2406\" data-end=\"2465\"\u003eRequired output signals (4–20 mA \/ HART \/ Modbus RS485)\u003c\/li\u003e\n\u003cli data-section-id=\"yx319x\" data-start=\"2466\" data-end=\"2495\"\u003ePower supply availability\u003c\/li\u003e\n\u003cli data-section-id=\"1mocoiy\" data-start=\"2496\" data-end=\"2535\"\u003ePressure and temperature conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2537\" data-end=\"2540\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2542\" data-end=\"2556\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2558\" data-end=\"2700\"\u003e\u003cstrong data-start=\"2558\" data-end=\"2609\"\u003eQ: What is Endress+Hauser Promag W 10 used for?\u003c\/strong\u003e\u003cbr data-start=\"2609\" data-end=\"2612\"\u003eA: It is used for electromagnetic flow measurement in water and wastewater applications.\u003c\/p\u003e\n\u003cp data-start=\"2702\" data-end=\"2826\"\u003e\u003cstrong data-start=\"2702\" data-end=\"2752\"\u003eQ: Is Promag W 10 suitable for drinking water?\u003c\/strong\u003e\u003cbr data-start=\"2752\" data-end=\"2755\"\u003eA: Yes, it is commonly used in water supply and drinking water systems.\u003c\/p\u003e\n\u003cp data-start=\"2828\" data-end=\"2927\"\u003e\u003cstrong data-start=\"2828\" data-end=\"2863\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-start=\"2863\" data-end=\"2866\"\u003eA: No, it has a maintenance-free design with no moving parts.\u003c\/p\u003e\n\u003cp data-start=\"2929\" data-end=\"3050\"\u003e\u003cstrong data-start=\"2929\" data-end=\"2968\"\u003eQ: What is the measuring principle?\u003c\/strong\u003e\u003cbr data-start=\"2968\" data-end=\"2971\"\u003eA: It uses electromagnetic induction to measure the flow of conductive liquids.\u003c\/p\u003e\n\u003cp data-start=\"3052\" data-end=\"3206\"\u003e\u003cstrong data-start=\"3052\" data-end=\"3091\"\u003eQ: Can it be installed underground?\u003c\/strong\u003e\u003cbr data-start=\"3091\" data-end=\"3094\"\u003eA: Yes, it supports IP68 protection for harsh installation environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3208\" data-end=\"3330\"\u003e\u003cstrong data-start=\"3208\" data-end=\"3247\"\u003eQ: What industries use Promag W 10?\u003c\/strong\u003e\u003cbr data-start=\"3247\" data-end=\"3250\"\u003eA: Water treatment, utilities, wastewater, and general industrial water systems.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311685107773,"sku":null,"price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-w10-flowmeter-product-view.png?v=1782889472"},{"product_id":"endress-hauser-proline-promag-w-300-electromagnetic-flowmeter-5w3b","title":"Endress+Hauser Proline Promag W 300 Electromagnetic Flowmeter 5W3B-","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"580\" data-start=\"544\" data-section-id=\"1vevt5w\"\u003eProduct Description\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-end=\"748\" data-start=\"582\"\u003eThe \u003cstrong data-end=\"642\" data-start=\"586\"\u003eEndress+Hauser Proline Promag W 300 (5W3B) Flowmeter\u003c\/strong\u003e is a high-performance electromagnetic flowmeter designed for demanding water and wastewater applications.\u003c\/p\u003e\n\u003cp data-end=\"960\" data-start=\"750\"\u003eIt provides reliable and accurate volumetric flow measurement of conductive liquids using electromagnetic induction technology, ensuring stable performance even under harsh environmental and process conditions.\u003c\/p\u003e\n\u003cp data-end=\"1170\" data-start=\"962\"\u003eThe Promag W 300 is optimized for utility and municipal water systems, offering advanced diagnostics, flexible system integration, and long-term operational stability for modern industrial automation systems.\u003c\/p\u003e\n\u003cp data-end=\"1352\" data-start=\"1172\"\u003eNatural SEO keywords included: \u003cstrong data-end=\"1232\" data-start=\"1203\"\u003eelectromagnetic flowmeter\u003c\/strong\u003e, \u003cstrong data-end=\"1254\" data-start=\"1234\"\u003ewater flow meter\u003c\/strong\u003e, \u003cstrong data-end=\"1287\" data-start=\"1256\"\u003ewastewater flow measurement\u003c\/strong\u003e, \u003cstrong data-end=\"1319\" data-start=\"1289\"\u003eEndress+Hauser flow sensor\u003c\/strong\u003e, \u003cstrong data-end=\"1352\" data-start=\"1321\"\u003eindustrial flow transmitter\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-end=\"1357\" data-start=\"1354\"\u003e\n\u003ch1 data-end=\"1375\" data-start=\"1359\" data-section-id=\"1vrrhye\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-end=\"1766\" data-start=\"1377\"\u003e• Electromagnetic flow measurement technology\u003cbr data-end=\"1425\" data-start=\"1422\"\u003e• Designed for water and wastewater applications\u003cbr data-end=\"1476\" data-start=\"1473\"\u003e• High accuracy and long-term stability\u003cbr data-end=\"1518\" data-start=\"1515\"\u003e• Maintenance-free design with no moving parts\u003cbr data-end=\"1567\" data-start=\"1564\"\u003e• Compact transmitter with flexible integration\u003cbr data-end=\"1617\" data-start=\"1614\"\u003e• Heartbeat Technology for diagnostics and verification\u003cbr data-end=\"1675\" data-start=\"1672\"\u003e• IP protection for harsh environments\u003cbr data-end=\"1716\" data-start=\"1713\"\u003e• Advanced communication and system connectivity\u003c\/p\u003e\n\u003chr data-end=\"1771\" data-start=\"1768\"\u003e\n\u003ch1 data-end=\"1799\" data-start=\"1773\" data-section-id=\"l5ozhv\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-end=\"2038\" data-start=\"1801\"\u003e\n\u003cli data-end=\"1828\" data-start=\"1801\" data-section-id=\"6p8cpv\"\u003eMunicipal water systems\u003c\/li\u003e\n\u003cli data-end=\"1860\" data-start=\"1829\" data-section-id=\"1cbb0k9\"\u003eWastewater treatment plants\u003c\/li\u003e\n\u003cli data-end=\"1892\" data-start=\"1861\" data-section-id=\"112r9b1\"\u003eDrinking water distribution\u003c\/li\u003e\n\u003cli data-end=\"1932\" data-start=\"1893\" data-section-id=\"1a9pss6\"\u003eIndustrial utility water monitoring\u003c\/li\u003e\n\u003cli data-end=\"1953\" data-start=\"1933\" data-section-id=\"gpou55\"\u003ePumping stations\u003c\/li\u003e\n\u003cli data-end=\"1976\" data-start=\"1954\" data-section-id=\"1ts7iec\"\u003eIrrigation systems\u003c\/li\u003e\n\u003cli data-end=\"2003\" data-start=\"1977\" data-section-id=\"1rzazoy\"\u003eCooling water circuits\u003c\/li\u003e\n\u003cli data-end=\"2038\" data-start=\"2004\" data-section-id=\"1f8j4lv\"\u003eGeneral water flow measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2043\" data-start=\"2040\"\u003e\n\u003ch1 data-end=\"2078\" data-start=\"2045\" data-section-id=\"6p5k8g\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-end=\"2119\" data-start=\"2080\"\u003eBefore selecting Promag W 300, confirm:\u003c\/p\u003e\n\u003cul data-end=\"2446\" data-start=\"2121\"\u003e\n\u003cli data-end=\"2157\" data-start=\"2121\" data-section-id=\"1i5hotm\"\u003ePipe size (DN range requirement)\u003c\/li\u003e\n\u003cli data-end=\"2193\" data-start=\"2158\" data-section-id=\"1hvo8j7\"\u003eMedium conductivity suitability\u003c\/li\u003e\n\u003cli data-end=\"2234\" data-start=\"2194\" data-section-id=\"mc68lf\"\u003eWater or wastewater application type\u003c\/li\u003e\n\u003cli data-end=\"2302\" data-start=\"2235\" data-section-id=\"12agbcf\"\u003eInstallation environment (outdoor, underground, hazardous area)\u003c\/li\u003e\n\u003cli data-end=\"2330\" data-start=\"2303\" data-section-id=\"1fh7rre\"\u003eRequired accuracy level\u003c\/li\u003e\n\u003cli data-end=\"2393\" data-start=\"2331\" data-section-id=\"1ki8ldi\"\u003eOutput communication (HART, Profibus, Ethernet\/IP, Modbus)\u003c\/li\u003e\n\u003cli data-end=\"2446\" data-start=\"2394\" data-section-id=\"1gjkbdk\"\u003ePower supply and system integration requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2451\" data-start=\"2448\"\u003e\n\u003ch1 data-end=\"2467\" data-start=\"2453\" data-section-id=\"a0z7dm\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-end=\"2612\" data-start=\"2469\"\u003e\u003cstrong data-end=\"2521\" data-start=\"2469\"\u003eQ: What is Endress+Hauser Promag W 300 used for?\u003c\/strong\u003e\u003cbr data-end=\"2524\" data-start=\"2521\"\u003eA: It is used for electromagnetic flow measurement in water and wastewater applications.\u003c\/p\u003e\n\u003cp data-end=\"2748\" data-start=\"2614\"\u003e\u003cstrong data-end=\"2661\" data-start=\"2614\"\u003eQ: Is Promag W 300 suitable for wastewater?\u003c\/strong\u003e\u003cbr data-end=\"2664\" data-start=\"2661\"\u003eA: Yes, it is specifically designed for municipal and industrial wastewater systems.\u003c\/p\u003e\n\u003cp data-end=\"2849\" data-start=\"2750\"\u003e\u003cstrong data-end=\"2785\" data-start=\"2750\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-end=\"2788\" data-start=\"2785\"\u003eA: No, it has a maintenance-free design with no moving parts.\u003c\/p\u003e\n\u003cp data-end=\"2975\" data-start=\"2851\"\u003e\u003cstrong data-end=\"2897\" data-start=\"2851\"\u003eQ: What measurement principle does it use?\u003c\/strong\u003e\u003cbr data-end=\"2900\" data-start=\"2897\"\u003eA: It uses electromagnetic induction to measure flow of conductive liquids.\u003c\/p\u003e\n\u003cp data-end=\"3075\" data-start=\"2977\"\u003e\u003cstrong data-end=\"2997\" data-start=\"2977\"\u003eQ: What is 5W3B?\u003c\/strong\u003e\u003cbr data-end=\"3000\" data-start=\"2997\"\u003eA: 5W3B is a specific order code variant of the Promag W 300 configuration.\u003c\/p\u003e\n\u003cp data-end=\"3216\" data-start=\"3077\"\u003e\u003cstrong data-end=\"3122\" data-start=\"3077\"\u003eQ: Can it be integrated into PLC systems?\u003c\/strong\u003e\u003cbr data-end=\"3125\" data-start=\"3122\"\u003eA: Yes, it supports multiple industrial communication protocols for automation integration.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311742287933,"sku":null,"price":1600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-w300-5w3b-flowmeter-product-view.png?v=1782889792"},{"product_id":"endress-hauser-proline-promag-w-400-electromagnetic-flowmeter-5w4c","title":"Endress+Hauser Proline Promag W 400 Electromagnetic Flowmeter 5W4C-","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"550\" data-end=\"586\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"588\" data-end=\"771\"\u003eThe \u003cstrong data-start=\"592\" data-end=\"648\"\u003eEndress+Hauser Proline Promag W 400 (5W4C) Flowmeter\u003c\/strong\u003e is a high-performance electromagnetic flowmeter designed for water, wastewater, and utility flow measurement applications.\u003c\/p\u003e\n\u003cp data-start=\"773\" data-end=\"1030\"\u003eIt provides accurate and stable volumetric flow measurement of conductive liquids using electromagnetic induction technology. The device is optimized for modern water infrastructure where reliability, low maintenance, and digital connectivity are essential.\u003c\/p\u003e\n\u003cp data-start=\"1032\" data-end=\"1203\"\u003ePromag W 400 supports advanced diagnostics and verification functions, enabling improved operational safety and reduced downtime in industrial and municipal water systems.\u003c\/p\u003e\n\u003cp data-start=\"1205\" data-end=\"1385\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1236\" data-end=\"1265\"\u003eelectromagnetic flowmeter\u003c\/strong\u003e, \u003cstrong data-start=\"1267\" data-end=\"1287\"\u003ewater flow meter\u003c\/strong\u003e, \u003cstrong data-start=\"1289\" data-end=\"1320\"\u003ewastewater flow measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1322\" data-end=\"1352\"\u003eEndress+Hauser flow sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1354\" data-end=\"1385\"\u003eindustrial flow transmitter\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1387\" data-end=\"1390\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1392\" data-end=\"1408\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1410\" data-end=\"1824\"\u003e• Electromagnetic flow measurement technology\u003cbr data-start=\"1455\" data-end=\"1458\"\u003e• Designed for water and wastewater applications\u003cbr data-start=\"1506\" data-end=\"1509\"\u003e• High measurement accuracy and long-term stability\u003cbr data-start=\"1560\" data-end=\"1563\"\u003e• Maintenance-free design with no moving parts\u003cbr data-start=\"1609\" data-end=\"1612\"\u003e• Heartbeat Technology for diagnostics and verification\u003cbr data-start=\"1667\" data-end=\"1670\"\u003e• IP68 protection for harsh environments\u003cbr data-start=\"1710\" data-end=\"1713\"\u003e• Integrated web server for easy configuration\u003cbr data-start=\"1759\" data-end=\"1762\"\u003e• Advanced communication options (HART, Modbus, Ethernet\/IP)\u003c\/p\u003e\n\u003chr data-start=\"1826\" data-end=\"1829\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1831\" data-end=\"1857\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1859\" data-end=\"2126\"\u003e\n\u003cli data-section-id=\"g73vcp\" data-start=\"1859\" data-end=\"1899\"\u003eMunicipal water distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1cbb0k9\" data-start=\"1900\" data-end=\"1931\"\u003eWastewater treatment plants\u003c\/li\u003e\n\u003cli data-section-id=\"1l8to4r\" data-start=\"1932\" data-end=\"1961\"\u003eDrinking water monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"3a4m9u\" data-start=\"1962\" data-end=\"2007\"\u003eIndustrial utility water flow measurement\u003c\/li\u003e\n\u003cli data-section-id=\"gpou55\" data-start=\"2008\" data-end=\"2028\"\u003ePumping stations\u003c\/li\u003e\n\u003cli data-section-id=\"mblim\" data-start=\"2029\" data-end=\"2061\"\u003eIrrigation and canal systems\u003c\/li\u003e\n\u003cli data-section-id=\"2bp7yc\" data-start=\"2062\" data-end=\"2087\"\u003eCooling water systems\u003c\/li\u003e\n\u003cli data-section-id=\"srn18n\" data-start=\"2088\" data-end=\"2126\"\u003eGeneral industrial flow monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2128\" data-end=\"2131\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2133\" data-end=\"2166\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2168\" data-end=\"2207\"\u003eBefore selecting Promag W 400, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2209\" data-end=\"2507\"\u003e\n\u003cli data-section-id=\"7puzmw\" data-start=\"2209\" data-end=\"2249\"\u003ePipe diameter (DN range requirement)\u003c\/li\u003e\n\u003cli data-section-id=\"1hvo8j7\" data-start=\"2250\" data-end=\"2285\"\u003eMedium conductivity suitability\u003c\/li\u003e\n\u003cli data-section-id=\"1eh5j9p\" data-start=\"2286\" data-end=\"2343\"\u003eInstallation environment (buried, submerged, outdoor)\u003c\/li\u003e\n\u003cli data-section-id=\"98ni1o\" data-start=\"2344\" data-end=\"2409\"\u003eRequired communication protocol (HART \/ Modbus \/ Ethernet\/IP)\u003c\/li\u003e\n\u003cli data-section-id=\"1qp802k\" data-start=\"2410\" data-end=\"2440\"\u003eAccuracy level requirement\u003c\/li\u003e\n\u003cli data-section-id=\"t1yrlg\" data-start=\"2441\" data-end=\"2471\"\u003ePower supply configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1vqjw6k\" data-start=\"2472\" data-end=\"2507\"\u003ePressure and temperature limits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2509\" data-end=\"2512\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2514\" data-end=\"2528\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2530\" data-end=\"2673\"\u003e\u003cstrong data-start=\"2530\" data-end=\"2582\"\u003eQ: What is Endress+Hauser Promag W 400 used for?\u003c\/strong\u003e\u003cbr data-start=\"2582\" data-end=\"2585\"\u003eA: It is used for electromagnetic flow measurement in water and wastewater applications.\u003c\/p\u003e\n\u003cp data-start=\"2675\" data-end=\"2808\"\u003e\u003cstrong data-start=\"2675\" data-end=\"2732\"\u003eQ: Is Promag W 400 suitable for wastewater treatment?\u003c\/strong\u003e\u003cbr data-start=\"2732\" data-end=\"2735\"\u003eA: Yes, it is widely used in municipal and industrial wastewater systems.\u003c\/p\u003e\n\u003cp data-start=\"2810\" data-end=\"2911\"\u003e\u003cstrong data-start=\"2810\" data-end=\"2845\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-start=\"2845\" data-end=\"2848\"\u003eA: No, it is a maintenance-free flowmeter with no moving parts.\u003c\/p\u003e\n\u003cp data-start=\"2913\" data-end=\"3062\"\u003e\u003cstrong data-start=\"2913\" data-end=\"2949\"\u003eQ: What is Heartbeat Technology?\u003c\/strong\u003e\u003cbr data-start=\"2949\" data-end=\"2952\"\u003eA: It is a built-in diagnostic and verification system that ensures measurement reliability and device health.\u003c\/p\u003e\n\u003cp data-start=\"3064\" data-end=\"3178\"\u003e\u003cstrong data-start=\"3064\" data-end=\"3103\"\u003eQ: Can it be installed underground?\u003c\/strong\u003e\u003cbr data-start=\"3103\" data-end=\"3106\"\u003eA: Yes, it supports IP68 protection for harsh installation environments.\u003c\/p\u003e\n\u003cp data-start=\"3180\" data-end=\"3306\"\u003e\u003cstrong data-start=\"3180\" data-end=\"3230\"\u003eQ: What communication protocols are supported?\u003c\/strong\u003e\u003cbr data-start=\"3230\" data-end=\"3233\"\u003eA: Depending on configuration, it supports HART, Modbus, and Ethernet\/IP.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311789506621,"sku":null,"price":1600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-w400-5w4c-flowmeter-product-view.png?v=1782890027"},{"product_id":"endress-hauser-proline-prowirl-d-200-vortex-flowmeter-7d2b","title":"Endress+Hauser Proline Prowirl D 200 Vortex Flowmeter 7D2B-","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"573\" data-end=\"609\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"611\" data-end=\"805\" class=\"\"\u003eThe \u003cstrong data-start=\"615\" data-end=\"672\"\u003eEndress+Hauser Proline Prowirl D 200 Vortex Flowmeter\u003c\/strong\u003e is a cost-effective wafer-type vortex flowmeter designed for measuring steam, gases, and liquids in industrial process applications.\u003c\/p\u003e\n\u003cp data-start=\"807\" data-end=\"1086\"\u003eIt is optimized for basic flow measurement tasks and 1-to-1 replacement of orifice plate systems, offering improved accuracy and reduced pressure loss. The compact wafer design allows easy installation between flanges, making it suitable for space-constrained industrial systems.\u003c\/p\u003e\n\u003cp data-start=\"1088\" data-end=\"1308\"\u003eProwirl D 200 supports reliable flow and energy measurement, including saturated steam applications, and integrates seamlessly into modern industrial automation systems with advanced diagnostics and Heartbeat Technology.\u003c\/p\u003e\n\u003cp data-start=\"1310\" data-end=\"1474\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1341\" data-end=\"1361\"\u003evortex flowmeter\u003c\/strong\u003e, \u003cstrong data-start=\"1363\" data-end=\"1383\"\u003esteam flow meter\u003c\/strong\u003e, \u003cstrong data-start=\"1385\" data-end=\"1409\"\u003egas flow measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1411\" data-end=\"1442\"\u003eindustrial flow transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1444\" data-end=\"1474\"\u003eEndress+Hauser flow sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1476\" data-end=\"1479\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1481\" data-end=\"1497\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1499\" data-end=\"1890\"\u003e• Vortex flow measurement technology\u003cbr data-start=\"1535\" data-end=\"1538\"\u003e• Suitable for steam, gas, and liquid applications\u003cbr data-start=\"1588\" data-end=\"1591\"\u003e• Wafer design for easy installation\u003cbr data-start=\"1627\" data-end=\"1630\"\u003e• Compact and cost-effective solution\u003cbr data-start=\"1667\" data-end=\"1670\"\u003e• Integrated temperature measurement for steam energy flow\u003cbr data-start=\"1728\" data-end=\"1731\"\u003e• Heartbeat Technology for diagnostics and verification\u003cbr data-start=\"1786\" data-end=\"1789\"\u003e• High operational safety in industrial environments\u003cbr data-start=\"1841\" data-end=\"1844\"\u003e• Suitable for replacement of orifice plates\u003c\/p\u003e\n\u003chr data-start=\"1892\" data-end=\"1895\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1897\" data-end=\"1923\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1925\" data-end=\"2197\"\u003e\n\u003cli data-section-id=\"a5j4o8\" data-start=\"1925\" data-end=\"1959\"\u003eSteam flow measurement systems\u003c\/li\u003e\n\u003cli data-section-id=\"oede0m\" data-start=\"1960\" data-end=\"1989\"\u003eCompressed gas monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"17wd9ev\" data-start=\"1990\" data-end=\"2023\"\u003eIndustrial energy measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1a2tvd9\" data-start=\"2024\" data-end=\"2055\"\u003eHeating and utility systems\u003c\/li\u003e\n\u003cli data-section-id=\"e7vaxt\" data-start=\"2056\" data-end=\"2086\"\u003eChemical process utilities\u003c\/li\u003e\n\u003cli data-section-id=\"150o6tc\" data-start=\"2087\" data-end=\"2120\"\u003eOil and gas auxiliary systems\u003c\/li\u003e\n\u003cli data-section-id=\"1v63fnb\" data-start=\"2121\" data-end=\"2158\"\u003eHVAC and district heating systems\u003c\/li\u003e\n\u003cli data-section-id=\"srn18n\" data-start=\"2159\" data-end=\"2197\"\u003eGeneral industrial flow monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2199\" data-end=\"2202\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2204\" data-end=\"2237\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2239\" data-end=\"2279\"\u003eBefore selecting Prowirl D 200, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2281\" data-end=\"2604\"\u003e\n\u003cli data-section-id=\"285una\" data-start=\"2281\" data-end=\"2320\"\u003eMedium type (steam, gas, or liquid)\u003c\/li\u003e\n\u003cli data-section-id=\"1uku6zt\" data-start=\"2321\" data-end=\"2348\"\u003eFlow range requirements\u003c\/li\u003e\n\u003cli data-section-id=\"mcbaqs\" data-start=\"2349\" data-end=\"2381\"\u003ePipe size (DN compatibility)\u003c\/li\u003e\n\u003cli data-section-id=\"1zt8bl\" data-start=\"2382\" data-end=\"2429\"\u003eProcess pressure and temperature conditions\u003c\/li\u003e\n\u003cli data-section-id=\"12a6cvt\" data-start=\"2430\" data-end=\"2484\"\u003eInstallation type (wafer mounting between flanges)\u003c\/li\u003e\n\u003cli data-section-id=\"1xhp63w\" data-start=\"2485\" data-end=\"2548\"\u003eOutput communication requirements (HART \/ fieldbus options)\u003c\/li\u003e\n\u003cli data-section-id=\"1b8did5\" data-start=\"2549\" data-end=\"2604\"\u003eEnergy measurement requirement (steam applications)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2606\" data-end=\"2609\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2611\" data-end=\"2625\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2627\" data-end=\"2781\"\u003e\u003cstrong data-start=\"2627\" data-end=\"2680\"\u003eQ: What is Endress+Hauser Prowirl D 200 used for?\u003c\/strong\u003e\u003cbr data-start=\"2680\" data-end=\"2683\"\u003eA: It is used for vortex flow measurement of steam, gases, and liquids in industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"2783\" data-end=\"2895\"\u003e\u003cstrong data-start=\"2783\" data-end=\"2816\"\u003eQ: Can it measure steam flow?\u003c\/strong\u003e\u003cbr data-start=\"2816\" data-end=\"2819\"\u003eA: Yes, it is commonly used for saturated and superheated steam measurement.\u003c\/p\u003e\n\u003cp data-start=\"2897\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2897\" data-end=\"2936\"\u003eQ: What is the measuring principle?\u003c\/strong\u003e\u003cbr data-start=\"2936\" data-end=\"2939\"\u003eA: It uses vortex shedding technology to measure flow rate.\u003c\/p\u003e\n\u003cp data-start=\"3000\" data-end=\"3113\"\u003e\u003cstrong data-start=\"3000\" data-end=\"3043\"\u003eQ: Is it suitable for gas applications?\u003c\/strong\u003e\u003cbr data-start=\"3043\" data-end=\"3046\"\u003eA: Yes, it can measure compressed gases and process gases reliably.\u003c\/p\u003e\n\u003cp data-start=\"3115\" data-end=\"3246\"\u003e\u003cstrong data-start=\"3115\" data-end=\"3151\"\u003eQ: What is Heartbeat Technology?\u003c\/strong\u003e\u003cbr data-start=\"3151\" data-end=\"3154\"\u003eA: It is a built-in diagnostic and verification system for device health and process safety.\u003c\/p\u003e\n\u003cp data-start=\"3248\" data-end=\"3355\"\u003e\u003cstrong data-start=\"3248\" data-end=\"3283\"\u003eQ: Is installation complicated?\u003c\/strong\u003e\u003cbr data-start=\"3283\" data-end=\"3286\"\u003eA: No, it uses a wafer design that installs directly between flanges.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43311873589309,"sku":null,"price":1750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/prowirl-d200-vortex-flowmeter-product-view.png?v=1782890422"},{"product_id":"endress-hauser-proline-prowirl-f-200-flowmeter-7f2c50","title":"Endress+Hauser Proline Prowirl F 200 Flowmeter 7F2C50-","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"725\" data-start=\"689\" data-section-id=\"1vevt5w\"\u003eProduct Description\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-end=\"899\" data-start=\"727\"\u003eThe \u003cstrong data-end=\"797\" data-start=\"731\"\u003eEndress+Hauser Proline Prowirl F 200 (7F2C50) Vortex Flowmeter\u003c\/strong\u003e is designed for reliable measurement of steam, gases, and liquids in industrial process applications.\u003c\/p\u003e\n\u003cp data-end=\"1203\" data-start=\"901\"\u003eUsing vortex shedding technology, the flowmeter delivers stable and accurate flow measurement while minimizing maintenance requirements due to its no-moving-parts design. The integrated temperature measurement capability allows additional energy monitoring functions, especially for steam applications.\u003c\/p\u003e\n\u003cp data-end=\"1423\" data-start=\"1205\"\u003eProwirl F 200 is widely used in utility systems, process industries, and energy monitoring applications where continuous and dependable \u003cstrong data-end=\"1372\" data-start=\"1341\"\u003eindustrial flow measurement\u003c\/strong\u003e is required. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1589\" data-start=\"1425\"\u003eNatural SEO keywords included: \u003cstrong data-end=\"1476\" data-start=\"1456\"\u003evortex flowmeter\u003c\/strong\u003e, \u003cstrong data-end=\"1498\" data-start=\"1478\"\u003esteam flow meter\u003c\/strong\u003e, \u003cstrong data-end=\"1524\" data-start=\"1500\"\u003egas flow measurement\u003c\/strong\u003e, \u003cstrong data-end=\"1557\" data-start=\"1526\"\u003eindustrial flow transmitter\u003c\/strong\u003e, \u003cstrong data-end=\"1589\" data-start=\"1559\"\u003eEndress+Hauser flow sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-end=\"1594\" data-start=\"1591\"\u003e\n\u003ch1 data-end=\"1612\" data-start=\"1596\" data-section-id=\"1vrrhye\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-end=\"1960\" data-start=\"1614\"\u003e• Vortex flow measurement technology\u003cbr data-end=\"1653\" data-start=\"1650\"\u003e• Suitable for steam, gas and liquid applications\u003cbr data-end=\"1705\" data-start=\"1702\"\u003e• Integrated temperature measurement capability\u003cbr data-end=\"1755\" data-start=\"1752\"\u003e• Maintenance-free design with no moving parts\u003cbr data-end=\"1804\" data-start=\"1801\"\u003e• High measurement stability\u003cbr data-end=\"1835\" data-start=\"1832\"\u003e• Heartbeat Technology diagnostics\u003cbr data-end=\"1872\" data-start=\"1869\"\u003e• Multiple communication options available\u003cbr data-end=\"1917\" data-start=\"1914\"\u003e• Suitable for industrial utility systems\u003c\/p\u003e\n\u003chr data-end=\"1965\" data-start=\"1962\"\u003e\n\u003ch1 data-end=\"1993\" data-start=\"1967\" data-section-id=\"l5ozhv\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-end=\"2257\" data-start=\"1995\"\u003e\n\u003cli data-end=\"2029\" data-start=\"1995\" data-section-id=\"a5j4o8\"\u003eSteam flow measurement systems\u003c\/li\u003e\n\u003cli data-end=\"2063\" data-start=\"2030\" data-section-id=\"1wzi2tf\"\u003eIndustrial utility monitoring\u003c\/li\u003e\n\u003cli data-end=\"2090\" data-start=\"2064\" data-section-id=\"l7hwrn\"\u003eCompressed air systems\u003c\/li\u003e\n\u003cli data-end=\"2121\" data-start=\"2091\" data-section-id=\"m04w6y\"\u003eGas distribution processes\u003c\/li\u003e\n\u003cli data-end=\"2155\" data-start=\"2122\" data-section-id=\"f3t2kj\"\u003eEnergy consumption monitoring\u003c\/li\u003e\n\u003cli data-end=\"2186\" data-start=\"2156\" data-section-id=\"6gyw6r\"\u003eChemical processing plants\u003c\/li\u003e\n\u003cli data-end=\"2218\" data-start=\"2187\" data-section-id=\"1jhjfua\"\u003ePower generation facilities\u003c\/li\u003e\n\u003cli data-end=\"2257\" data-start=\"2219\" data-section-id=\"xh4ves\"\u003eGeneral industrial process systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2262\" data-start=\"2259\"\u003e\n\u003ch1 data-end=\"2297\" data-start=\"2264\" data-section-id=\"6p5k8g\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-end=\"2339\" data-start=\"2299\"\u003eBefore selecting Prowirl F 200, confirm:\u003c\/p\u003e\n\u003cul data-end=\"2657\" data-start=\"2341\"\u003e\n\u003cli data-end=\"2380\" data-start=\"2341\" data-section-id=\"285una\"\u003eMedium type (steam, gas, or liquid)\u003c\/li\u003e\n\u003cli data-end=\"2426\" data-start=\"2381\" data-section-id=\"11i5so8\"\u003ePipe size requirements (DN compatibility)\u003c\/li\u003e\n\u003cli data-end=\"2458\" data-start=\"2427\" data-section-id=\"vo2y1y\"\u003eProcess pressure conditions\u003c\/li\u003e\n\u003cli data-end=\"2488\" data-start=\"2459\" data-section-id=\"1a1xn0w\"\u003eProcess temperature range\u003c\/li\u003e\n\u003cli data-end=\"2553\" data-start=\"2489\" data-section-id=\"1sbu2xl\"\u003eRequired communication protocol (HART \/ Fieldbus \/ PROFIBUS)\u003c\/li\u003e\n\u003cli data-end=\"2599\" data-start=\"2554\" data-section-id=\"1bhcjt8\"\u003eInstallation type and flange requirements\u003c\/li\u003e\n\u003cli data-end=\"2657\" data-start=\"2600\" data-section-id=\"1ift3fa\"\u003eEnergy monitoring requirements for steam applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2662\" data-start=\"2659\"\u003e\n\u003ch1 data-end=\"2678\" data-start=\"2664\" data-section-id=\"a0z7dm\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-end=\"2872\" data-start=\"2680\"\u003e\u003cstrong data-end=\"2733\" data-start=\"2680\"\u003eQ: What is Endress+Hauser Prowirl F 200 used for?\u003c\/strong\u003e\u003cbr data-end=\"2736\" data-start=\"2733\"\u003eA: It is used for vortex flow measurement of steam, gases, and liquids in industrial applications. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3030\" data-start=\"2874\"\u003e\u003cstrong data-end=\"2913\" data-start=\"2874\"\u003eQ: Can Prowirl F 200 measure steam?\u003c\/strong\u003e\u003cbr data-end=\"2916\" data-start=\"2913\"\u003eA: Yes. It is commonly used for saturated and superheated steam measurement. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3139\" data-start=\"3032\"\u003e\u003cstrong data-end=\"3067\" data-start=\"3032\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-end=\"3070\" data-start=\"3067\"\u003eA: No. Its no-moving-parts design minimizes maintenance requirements.\u003c\/p\u003e\n\u003cp data-end=\"3316\" data-start=\"3141\"\u003e\u003cstrong data-end=\"3189\" data-start=\"3141\"\u003eQ: What communication options are available?\u003c\/strong\u003e\u003cbr data-end=\"3192\" data-start=\"3189\"\u003eA: Depending on configuration, it supports HART, PROFIBUS PA, and FOUNDATION Fieldbus. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3500\" data-start=\"3318\"\u003e\u003cstrong data-end=\"3340\" data-start=\"3318\"\u003eQ: What is 7F2C50?\u003c\/strong\u003e\u003cbr data-end=\"3343\" data-start=\"3340\"\u003eA: 7F2C50 is a configuration\/order code within the Prowirl F 200 product family rather than a standalone product model. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3638\" data-start=\"3502\"\u003e\u003cstrong data-end=\"3554\" data-start=\"3502\"\u003eQ: Is it suitable for energy monitoring systems?\u003c\/strong\u003e\u003cbr data-end=\"3557\" data-start=\"3554\"\u003eA: Yes. It is commonly used for steam and utility energy management applications.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43312170074173,"sku":null,"price":3420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/prowirl-f200-7f2c50-product-view.png?v=1782892406"},{"product_id":"endress-hauser-liquisys-clm223-conductivity-transmitter","title":"Endress+Hauser Liquisys CLM223 Conductivity Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"630\" data-end=\"666\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"668\" data-end=\"832\"\u003eThe \u003cstrong data-start=\"672\" data-end=\"718\"\u003eEndress+Hauser Liquisys CLM223 Transmitter\u003c\/strong\u003e is a reliable conductivity transmitter designed for continuous liquid analysis and industrial process monitoring.\u003c\/p\u003e\n\u003cp data-start=\"834\" data-end=\"1123\"\u003eIt supports analog conductivity sensors and provides stable measurement performance for conductivity, resistivity, and concentration monitoring applications. The modular design allows flexible adaptation to different process requirements while simplifying maintenance and system expansion.\u003c\/p\u003e\n\u003cp data-start=\"1125\" data-end=\"1308\"\u003eCLM223 is widely used in water treatment, chemical processing, and industrial utilities where dependable \u003cstrong data-start=\"1230\" data-end=\"1258\"\u003econductivity measurement\u003c\/strong\u003e and long-term operational stability are required.\u003c\/p\u003e\n\u003cp data-start=\"1310\" data-end=\"1522\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1341\" data-end=\"1369\"\u003econductivity transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1371\" data-end=\"1410\"\u003eindustrial conductivity measurement\u003c\/strong\u003e, \u003cstrong data-start=\"1412\" data-end=\"1443\"\u003eliquid analysis transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1445\" data-end=\"1484\"\u003eEndress+Hauser conductivity monitor\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1524\" data-end=\"1527\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1529\" data-end=\"1545\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1547\" data-end=\"1906\"\u003e• Supports conductivity and resistivity measurement\u003cbr data-start=\"1598\" data-end=\"1601\"\u003e• Compatible with analog conductivity sensors\u003cbr data-start=\"1646\" data-end=\"1649\"\u003e• Modular design for flexible configuration\u003cbr data-start=\"1692\" data-end=\"1695\"\u003e• Continuous process and sensor monitoring\u003cbr data-start=\"1737\" data-end=\"1740\"\u003e• Supports 4–20 mA output communication\u003cbr data-start=\"1779\" data-end=\"1782\"\u003e• Available with HART and PROFIBUS options\u003cbr data-start=\"1824\" data-end=\"1827\"\u003e• User-friendly operation and calibration\u003cbr data-start=\"1868\" data-end=\"1871\"\u003e• Reliable industrial performance\u003c\/p\u003e\n\u003chr data-start=\"1908\" data-end=\"1911\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1913\" data-end=\"1939\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1941\" data-end=\"2203\"\u003e\n\u003cli data-section-id=\"hcl0oj\" data-start=\"1941\" data-end=\"1975\"\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"1820j57\" data-start=\"1976\" data-end=\"2007\"\u003eChemical process monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1u082fb\" data-start=\"2008\" data-end=\"2040\"\u003eFood and beverage production\u003c\/li\u003e\n\u003cli data-section-id=\"1sm2t9j\" data-start=\"2041\" data-end=\"2069\"\u003ePower generation systems\u003c\/li\u003e\n\u003cli data-section-id=\"pw3g4v\" data-start=\"2070\" data-end=\"2102\"\u003ePharmaceutical manufacturing\u003c\/li\u003e\n\u003cli data-section-id=\"1wzi2tf\" data-start=\"2103\" data-end=\"2136\"\u003eIndustrial utility monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"ixvkvb\" data-start=\"2137\" data-end=\"2164\"\u003eUltrapure water systems\u003c\/li\u003e\n\u003cli data-section-id=\"hday4t\" data-start=\"2165\" data-end=\"2203\"\u003eContinuous liquid analysis systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2205\" data-end=\"2208\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2210\" data-end=\"2243\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2245\" data-end=\"2278\"\u003eBefore selecting CLM223, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2280\" data-end=\"2614\"\u003e\n\u003cli data-section-id=\"88y4q5\" data-start=\"2280\" data-end=\"2352\"\u003eRequired measurement type (conductivity, resistivity, concentration)\u003c\/li\u003e\n\u003cli data-section-id=\"1cz1wje\" data-start=\"2353\" data-end=\"2384\"\u003eAnalog sensor compatibility\u003c\/li\u003e\n\u003cli data-section-id=\"13offp6\" data-start=\"2385\" data-end=\"2450\"\u003eOutput communication requirements (4–20 mA \/ HART \/ PROFIBUS)\u003c\/li\u003e\n\u003cli data-section-id=\"1vvz65e\" data-start=\"2451\" data-end=\"2497\"\u003eInstallation requirements (panel mounting)\u003c\/li\u003e\n\u003cli data-section-id=\"1t7vsbs\" data-start=\"2498\" data-end=\"2527\"\u003ePower supply requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1ayxe9b\" data-start=\"2528\" data-end=\"2562\"\u003eProcess temperature conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1scvcg6\" data-start=\"2563\" data-end=\"2614\"\u003eIndustrial control system compatibility (PLC\/DCS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2616\" data-end=\"2619\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2621\" data-end=\"2635\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2637\" data-end=\"2825\"\u003e\u003cstrong data-start=\"2637\" data-end=\"2683\"\u003eQ: What is Endress+Hauser CLM223 used for?\u003c\/strong\u003e\u003cbr data-start=\"2683\" data-end=\"2686\"\u003eA: It is used for conductivity measurement and continuous liquid analysis in industrial applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2827\" data-end=\"2985\"\u003e\u003cstrong data-start=\"2827\" data-end=\"2867\"\u003eQ: Which sensors can CLM223 support?\u003c\/strong\u003e\u003cbr data-start=\"2867\" data-end=\"2870\"\u003eA: It supports analog conductivity sensors for industrial process monitoring. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2987\" data-end=\"3164\"\u003e\u003cstrong data-start=\"2987\" data-end=\"3033\"\u003eQ: Does CLM223 support HART communication?\u003c\/strong\u003e\u003cbr data-start=\"3033\" data-end=\"3036\"\u003eA: Yes. Depending on configuration, HART and PROFIBUS communication options are available. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3166\" data-end=\"3328\"\u003e\u003cstrong data-start=\"3166\" data-end=\"3206\"\u003eQ: Can CLM223 measure concentration?\u003c\/strong\u003e\u003cbr data-start=\"3206\" data-end=\"3209\"\u003eA: Yes. It can support conductivity, resistivity, and concentration measurements. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3330\" data-end=\"3522\"\u003e\u003cstrong data-start=\"3330\" data-end=\"3373\"\u003eQ: What industries commonly use CLM223?\u003c\/strong\u003e\u003cbr data-start=\"3373\" data-end=\"3376\"\u003eA: Water treatment, chemical processing, power generation, food and beverage, and pharmaceutical industries. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3524\" data-end=\"3684\"\u003e\u003cstrong data-start=\"3524\" data-end=\"3559\"\u003eQ: Is CLM223 easy to configure?\u003c\/strong\u003e\u003cbr data-start=\"3559\" data-end=\"3562\"\u003eA: Yes. It features a simple menu structure and straightforward calibration process. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43312185573437,"sku":null,"price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/clm223-conductivity-transmitter-product-view.png?v=1782892924"},{"product_id":"endress-hauser-soliphant-ftm51-level-switch","title":"Endress+Hauser Soliphant FTM51 Level Switch","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"566\" data-end=\"602\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"604\" data-end=\"781\"\u003eThe \u003cstrong data-start=\"608\" data-end=\"655\"\u003eEndress+Hauser Soliphant FTM51 Level Switch\u003c\/strong\u003e is a vibronic point level switch designed for reliable detection of bulk solids in industrial storage and processing systems.\u003c\/p\u003e\n\u003cp data-start=\"783\" data-end=\"1032\"\u003eUsing vibration fork technology, the FTM51 provides dependable level detection without requiring calibration and maintains stable performance even in applications involving low bulk density materials, dust generation, or changing process conditions.\u003c\/p\u003e\n\u003cp data-start=\"1034\" data-end=\"1208\"\u003eThe robust construction and maintenance-free operating principle help reduce downtime and improve process reliability, making it suitable for continuous industrial operation.\u003c\/p\u003e\n\u003cp data-start=\"1210\" data-end=\"1389\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1241\" data-end=\"1266\"\u003evibronic level switch\u003c\/strong\u003e, \u003cstrong data-start=\"1268\" data-end=\"1299\"\u003ebulk solids level detection\u003c\/strong\u003e, \u003cstrong data-start=\"1301\" data-end=\"1323\"\u003epoint level switch\u003c\/strong\u003e, \u003cstrong data-start=\"1325\" data-end=\"1356\"\u003eindustrial level monitoring\u003c\/strong\u003e, \u003cstrong data-start=\"1358\" data-end=\"1389\"\u003eEndress+Hauser level sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1391\" data-end=\"1394\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1396\" data-end=\"1412\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1414\" data-end=\"1745\"\u003e• Vibronic fork measurement technology\u003cbr data-start=\"1452\" data-end=\"1455\"\u003e• Reliable point level detection for bulk solids\u003cbr data-start=\"1503\" data-end=\"1506\"\u003e• Calibration-free operation\u003cbr data-start=\"1534\" data-end=\"1537\"\u003e• Stable performance in dusty environments\u003cbr data-start=\"1579\" data-end=\"1582\"\u003e• Maintenance-free design\u003cbr data-start=\"1607\" data-end=\"1610\"\u003e• High resistance to buildup and vibration\u003cbr data-start=\"1652\" data-end=\"1655\"\u003e• Suitable for low bulk density materials\u003cbr data-start=\"1696\" data-end=\"1699\"\u003e• Compact and robust industrial construction\u003c\/p\u003e\n\u003chr data-start=\"1747\" data-end=\"1750\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1752\" data-end=\"1778\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1780\" data-end=\"2069\"\u003e\n\u003cli data-section-id=\"wl3rk3\" data-start=\"1780\" data-end=\"1822\"\u003eCement and building materials industry\u003c\/li\u003e\n\u003cli data-section-id=\"16l55r4\" data-start=\"1823\" data-end=\"1847\"\u003ePowder storage silos\u003c\/li\u003e\n\u003cli data-section-id=\"83kzuq\" data-start=\"1848\" data-end=\"1885\"\u003eGrain and agricultural processing\u003c\/li\u003e\n\u003cli data-section-id=\"272zse\" data-start=\"1886\" data-end=\"1922\"\u003eChemical powder handling systems\u003c\/li\u003e\n\u003cli data-section-id=\"ru0aj7\" data-start=\"1923\" data-end=\"1957\"\u003ePlastic pellet storage systems\u003c\/li\u003e\n\u003cli data-section-id=\"wqzvn4\" data-start=\"1958\" data-end=\"1994\"\u003eMining and aggregates processing\u003c\/li\u003e\n\u003cli data-section-id=\"1spnpwt\" data-start=\"1995\" data-end=\"2030\"\u003eBulk material conveying systems\u003c\/li\u003e\n\u003cli data-section-id=\"8n0as4\" data-start=\"2031\" data-end=\"2069\"\u003eIndustrial process storage vessels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2071\" data-end=\"2074\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2076\" data-end=\"2109\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2111\" data-end=\"2143\"\u003eBefore selecting FTM51, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2145\" data-end=\"2454\"\u003e\n\u003cli data-section-id=\"w92xup\" data-start=\"2145\" data-end=\"2198\"\u003eMaterial type (powder, granules, pellets, solids)\u003c\/li\u003e\n\u003cli data-section-id=\"c3udrg\" data-start=\"2199\" data-end=\"2228\"\u003eBulk density requirements\u003c\/li\u003e\n\u003cli data-section-id=\"q9mmxg\" data-start=\"2229\" data-end=\"2274\"\u003eMounting position and installation method\u003c\/li\u003e\n\u003cli data-section-id=\"17lrozl\" data-start=\"2275\" data-end=\"2322\"\u003eProcess temperature and pressure conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1m0y5fm\" data-start=\"2323\" data-end=\"2372\"\u003eOutput requirements (relay, PNP, NAMUR, etc.)\u003c\/li\u003e\n\u003cli data-section-id=\"1w7hpax\" data-start=\"2373\" data-end=\"2413\"\u003eHazardous area approval requirements\u003c\/li\u003e\n\u003cli data-section-id=\"98ftr5\" data-start=\"2414\" data-end=\"2454\"\u003eControl system compatibility (PLC\/DCS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2456\" data-end=\"2459\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2461\" data-end=\"2475\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2477\" data-end=\"2607\"\u003e\u003cstrong data-start=\"2477\" data-end=\"2522\"\u003eQ: What is Endress+Hauser FTM51 used for?\u003c\/strong\u003e\u003cbr data-start=\"2522\" data-end=\"2525\"\u003eA: It is used for point level detection of bulk solids in industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"2609\" data-end=\"2738\"\u003e\u003cstrong data-start=\"2609\" data-end=\"2652\"\u003eQ: Does FTM51 measure continuous level?\u003c\/strong\u003e\u003cbr data-start=\"2652\" data-end=\"2655\"\u003eA: No. It is a point level switch designed to detect predefined high or low levels.\u003c\/p\u003e\n\u003cp data-start=\"2740\" data-end=\"2874\"\u003e\u003cstrong data-start=\"2740\" data-end=\"2788\"\u003eQ: Can FTM51 work with powders and granules?\u003c\/strong\u003e\u003cbr data-start=\"2788\" data-end=\"2791\"\u003eA: Yes. It is suitable for powders, pellets, grains, and many bulk solid materials.\u003c\/p\u003e\n\u003cp data-start=\"2876\" data-end=\"2985\"\u003e\u003cstrong data-start=\"2876\" data-end=\"2911\"\u003eQ: Does it require calibration?\u003c\/strong\u003e\u003cbr data-start=\"2911\" data-end=\"2914\"\u003eA: No. The vibration fork technology allows calibration-free operation.\u003c\/p\u003e\n\u003cp data-start=\"2987\" data-end=\"3105\"\u003e\u003cstrong data-start=\"2987\" data-end=\"3028\"\u003eQ: Can it work in dusty environments?\u003c\/strong\u003e\u003cbr data-start=\"3028\" data-end=\"3031\"\u003eA: Yes. It is designed for reliable operation in dusty process conditions.\u003c\/p\u003e\n\u003cp data-start=\"3107\" data-end=\"3240\"\u003e\u003cstrong data-start=\"3107\" data-end=\"3149\"\u003eQ: What industries commonly use FTM51?\u003c\/strong\u003e\u003cbr data-start=\"3149\" data-end=\"3152\"\u003eA: Cement, chemical, food processing, agriculture, mining, and bulk material industries.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43312237969469,"sku":null,"price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/ftm51-level-switch-product-view.png?v=1782893555"},{"product_id":"endress-hauser-deltabar-pmd55-pressure-transmitter","title":"Endress+Hauser Deltabar PMD55 Pressure Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"622\" data-end=\"658\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"660\" data-end=\"844\"\u003eThe \u003cstrong data-start=\"664\" data-end=\"718\"\u003eEndress+Hauser Deltabar PMD55 Pressure Transmitter\u003c\/strong\u003e is a differential pressure instrument designed for reliable measurement of pressure differences in liquids, gases, and steam.\u003c\/p\u003e\n\u003cp data-start=\"846\" data-end=\"1127\"\u003eIt is commonly used for \u003cstrong data-start=\"870\" data-end=\"907\"\u003elevel measurement in closed tanks\u003c\/strong\u003e, \u003cstrong data-start=\"909\" data-end=\"930\"\u003efilter monitoring\u003c\/strong\u003e, and \u003cstrong data-start=\"936\" data-end=\"995\"\u003eflow measurement using differential pressure principles\u003c\/strong\u003e. The device features a robust metal sensor with high long-term stability, making it suitable for demanding industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"1129\" data-end=\"1327\"\u003eWith stable signal output and flexible configuration, PMD55 is widely applied in process industries where accurate \u003cstrong data-start=\"1244\" data-end=\"1281\"\u003edifferential pressure measurement\u003c\/strong\u003e is required for safe and efficient operation.\u003c\/p\u003e\n\u003cp data-start=\"1329\" data-end=\"1523\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1360\" data-end=\"1397\"\u003edifferential pressure transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1399\" data-end=\"1429\"\u003eindustrial pressure sensor\u003c\/strong\u003e, \u003cstrong data-start=\"1431\" data-end=\"1464\"\u003elevel measurement transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1466\" data-end=\"1490\"\u003eEndress+Hauser PMD55\u003c\/strong\u003e, \u003cstrong data-start=\"1492\" data-end=\"1523\"\u003eprocess pressure monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1525\" data-end=\"1528\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1530\" data-end=\"1546\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1548\" data-end=\"1879\"\u003e• Differential pressure measurement technology\u003cbr data-start=\"1594\" data-end=\"1597\"\u003e• Suitable for liquids, gases, and steam\u003cbr data-start=\"1637\" data-end=\"1640\"\u003e• High accuracy and long-term stability\u003cbr data-start=\"1679\" data-end=\"1682\"\u003e• Metal diaphragm sensor design\u003cbr data-start=\"1713\" data-end=\"1716\"\u003e• Supports level, flow, and pressure applications\u003cbr data-start=\"1765\" data-end=\"1768\"\u003e• SIL safety compliance options\u003cbr data-start=\"1799\" data-end=\"1802\"\u003e• Easy commissioning and configuration\u003cbr data-start=\"1840\" data-end=\"1843\"\u003e• Robust industrial housing design\u003c\/p\u003e\n\u003chr data-start=\"1881\" data-end=\"1884\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"1886\" data-end=\"1912\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"1914\" data-end=\"2175\"\u003e\n\u003cli data-section-id=\"14d0512\" data-start=\"1914\" data-end=\"1947\"\u003eClosed tank level measurement\u003c\/li\u003e\n\u003cli data-section-id=\"11unjsn\" data-start=\"1948\" data-end=\"1978\"\u003eFilter and pump monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1vo6cj7\" data-start=\"1979\" data-end=\"2021\"\u003eFlow measurement with primary elements\u003c\/li\u003e\n\u003cli data-section-id=\"1gmems1\" data-start=\"2022\" data-end=\"2053\"\u003eChemical processing systems\u003c\/li\u003e\n\u003cli data-section-id=\"6sf1za\" data-start=\"2054\" data-end=\"2078\"\u003eOil and gas industry\u003c\/li\u003e\n\u003cli data-section-id=\"1pgs5r5\" data-start=\"2079\" data-end=\"2111\"\u003eWater and wastewater systems\u003c\/li\u003e\n\u003cli data-section-id=\"1w6tdy9\" data-start=\"2112\" data-end=\"2144\"\u003eSteam and utility monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"m89x5v\" data-start=\"2145\" data-end=\"2175\"\u003eIndustrial process control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2177\" data-end=\"2180\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2182\" data-end=\"2215\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2217\" data-end=\"2249\"\u003eBefore selecting PMD55, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2251\" data-end=\"2598\"\u003e\n\u003cli data-section-id=\"18qwyuz\" data-start=\"2251\" data-end=\"2310\"\u003eMeasurement type (differential pressure \/ level \/ flow)\u003c\/li\u003e\n\u003cli data-section-id=\"1togz1p\" data-start=\"2311\" data-end=\"2341\"\u003ePressure range requirement\u003c\/li\u003e\n\u003cli data-section-id=\"1kubua0\" data-start=\"2342\" data-end=\"2381\"\u003eProcess medium (liquid, gas, steam)\u003c\/li\u003e\n\u003cli data-section-id=\"9mdjxp\" data-start=\"2382\" data-end=\"2439\"\u003eWet part material compatibility (316L, Alloy C, etc.)\u003c\/li\u003e\n\u003cli data-section-id=\"7fc48f\" data-start=\"2440\" data-end=\"2496\"\u003eInstallation type (remote seal \/ impulse line setup)\u003c\/li\u003e\n\u003cli data-section-id=\"1u5ytns\" data-start=\"2497\" data-end=\"2542\"\u003eOutput signal (4–20 mA \/ HART \/ fieldbus)\u003c\/li\u003e\n\u003cli data-section-id=\"yfnkfx\" data-start=\"2543\" data-end=\"2598\"\u003eSafety requirements (SIL \/ hazardous area approval)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2600\" data-end=\"2603\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2605\" data-end=\"2619\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2621\" data-end=\"2763\"\u003e\u003cstrong data-start=\"2621\" data-end=\"2666\"\u003eQ: What is Endress+Hauser PMD55 used for?\u003c\/strong\u003e\u003cbr data-start=\"2666\" data-end=\"2669\"\u003eA: It is used for differential pressure measurement in level, flow, and pressure applications.\u003c\/p\u003e\n\u003cp data-start=\"2765\" data-end=\"2894\"\u003e\u003cstrong data-start=\"2765\" data-end=\"2801\"\u003eQ: Can PMD55 measure tank level?\u003c\/strong\u003e\u003cbr data-start=\"2801\" data-end=\"2804\"\u003eA: Yes, it is commonly used for closed tank level measurement using differential pressure.\u003c\/p\u003e\n\u003cp data-start=\"2896\" data-end=\"3027\"\u003e\u003cstrong data-start=\"2896\" data-end=\"2944\"\u003eQ: Is PMD55 suitable for steam applications?\u003c\/strong\u003e\u003cbr data-start=\"2944\" data-end=\"2947\"\u003eA: Yes, it can measure pressure differences in steam, gas, and liquid processes.\u003c\/p\u003e\n\u003cp data-start=\"3029\" data-end=\"3163\"\u003e\u003cstrong data-start=\"3029\" data-end=\"3067\"\u003eQ: Does PMD55 require calibration?\u003c\/strong\u003e\u003cbr data-start=\"3067\" data-end=\"3070\"\u003eA: It is factory-calibrated and supports stable long-term operation with minimal maintenance.\u003c\/p\u003e\n\u003cp data-start=\"3165\" data-end=\"3287\"\u003e\u003cstrong data-start=\"3165\" data-end=\"3198\"\u003eQ: What industries use PMD55?\u003c\/strong\u003e\u003cbr data-start=\"3198\" data-end=\"3201\"\u003eA: Oil and gas, chemical processing, water treatment, and power generation industries.\u003c\/p\u003e\n\u003cp data-start=\"3289\" data-end=\"3422\"\u003e\u003cstrong data-start=\"3289\" data-end=\"3328\"\u003eQ: What is the measuring principle?\u003c\/strong\u003e\u003cbr data-start=\"3328\" data-end=\"3331\"\u003eA: It measures the difference between high and low pressure using a metal diaphragm sensor.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43312240263229,"sku":null,"price":950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/pmd55-differential-pressure-transmitter-product-view.png?v=1782894760"},{"product_id":"liquiline-cm42-liquid-analysis-transmitter","title":"Endress+Hauser Liquiline M CM42 Liquid Analysis Transmitter","description":"\u003ch1 data-section-id=\"1vevt5w\" data-start=\"715\" data-end=\"751\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"753\" data-end=\"972\"\u003eThe \u003cstrong data-start=\"757\" data-end=\"804\"\u003eEndress+Hauser Liquiline M CM42 Transmitter\u003c\/strong\u003e is a high-performance industrial liquid analysis device designed for continuous measurement of \u003cstrong data-start=\"900\" data-end=\"947\"\u003epH, ORP, conductivity, and dissolved oxygen\u003c\/strong\u003e in process applications.\u003c\/p\u003e\n\u003cp data-start=\"974\" data-end=\"1354\"\u003eThe transmitter supports both \u003cstrong data-start=\"1004\" data-end=\"1032\"\u003eMemosens digital sensors\u003c\/strong\u003e and conventional analog sensors, enabling flexible integration into existing industrial systems. Designed for both hazardous and non-hazardous environments, CM42 provides stable signal processing and simplified operation for demanding industries including chemicals, pharmaceuticals, food processing, and water treatment.\u003c\/p\u003e\n\u003cp data-start=\"1356\" data-end=\"1506\"\u003eIts intuitive configuration and multiple communication protocols help improve process efficiency while reducing maintenance requirements and downtime.\u003c\/p\u003e\n\u003cp data-start=\"1508\" data-end=\"1728\"\u003eNatural SEO keywords included: \u003cstrong data-start=\"1539\" data-end=\"1570\"\u003eliquid analysis transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1572\" data-end=\"1590\"\u003epH transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1592\" data-end=\"1620\"\u003econductivity transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1622\" data-end=\"1653\"\u003eoxygen analyzer transmitter\u003c\/strong\u003e, \u003cstrong data-start=\"1655\" data-end=\"1689\"\u003eindustrial process transmitter\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1730\" data-end=\"1733\"\u003e\n\u003ch1 data-section-id=\"1vrrhye\" data-start=\"1735\" data-end=\"1751\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1753\" data-end=\"2217\"\u003e• Supports pH, ORP, conductivity, and oxygen measurement\u003cbr data-start=\"1809\" data-end=\"1812\"\u003e• Compatible with Memosens and analog sensors\u003cbr data-start=\"1857\" data-end=\"1860\"\u003e• One-channel transmitter design\u003cbr data-start=\"1892\" data-end=\"1895\"\u003e• HART \/ PROFIBUS PA \/ FOUNDATION Fieldbus support\u003cbr data-start=\"1945\" data-end=\"1948\"\u003e• Suitable for hazardous and non-hazardous areas\u003cbr data-start=\"1996\" data-end=\"1999\"\u003e• IP66\/IP67 protection rating\u003cbr data-start=\"2028\" data-end=\"2031\"\u003e• Stainless steel or plastic housing options\u003cbr data-start=\"2075\" data-end=\"2078\"\u003e• Simplified operation and maintenance\u003cbr data-start=\"2116\" data-end=\"2119\"\u003e• Suitable for process industries and hygienic applications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2219\" data-end=\"2222\"\u003e\n\u003ch1 data-section-id=\"l5ozhv\" data-start=\"2224\" data-end=\"2250\"\u003eApplications\u003c\/h1\u003e\n\u003cul data-start=\"2252\" data-end=\"2502\"\u003e\n\u003cli data-section-id=\"s8kosx\" data-start=\"2252\" data-end=\"2280\"\u003eChemical process systems\u003c\/li\u003e\n\u003cli data-section-id=\"xtkpik\" data-start=\"2281\" data-end=\"2310\"\u003ePharmaceutical production\u003c\/li\u003e\n\u003cli data-section-id=\"1chdoi7\" data-start=\"2311\" data-end=\"2343\"\u003eFood and beverage processing\u003c\/li\u003e\n\u003cli data-section-id=\"hcl0oj\" data-start=\"2344\" data-end=\"2378\"\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"79zscl\" data-start=\"2379\" data-end=\"2406\"\u003ePower generation plants\u003c\/li\u003e\n\u003cli data-section-id=\"wsgffl\" data-start=\"2407\" data-end=\"2438\"\u003eOil and gas process systems\u003c\/li\u003e\n\u003cli data-section-id=\"199upxr\" data-start=\"2439\" data-end=\"2471\"\u003eIndustrial liquid monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"pdmsga\" data-start=\"2472\" data-end=\"2502\"\u003eProcess automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2504\" data-end=\"2507\"\u003e\n\u003ch1 data-section-id=\"6p5k8g\" data-start=\"2509\" data-end=\"2542\"\u003eSelection Notes\u003c\/h1\u003e\n\u003cp data-start=\"2544\" data-end=\"2587\"\u003eBefore selecting Liquiline M CM42, confirm:\u003c\/p\u003e\n\u003cul data-start=\"2589\" data-end=\"2937\"\u003e\n\u003cli data-section-id=\"6nrgpw\" data-start=\"2589\" data-end=\"2658\"\u003eRequired measurement parameter (pH \/ ORP \/ conductivity \/ oxygen)\u003c\/li\u003e\n\u003cli data-section-id=\"16fno35\" data-start=\"2659\" data-end=\"2695\"\u003eSensor type (Memosens or analog)\u003c\/li\u003e\n\u003cli data-section-id=\"1clxqch\" data-start=\"2696\" data-end=\"2739\"\u003eCommunication protocol (HART \/ FF \/ PA)\u003c\/li\u003e\n\u003cli data-section-id=\"iopnlq\" data-start=\"2740\" data-end=\"2771\"\u003eHazardous area requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1cus2za\" data-start=\"2772\" data-end=\"2832\"\u003eHousing material preference (plastic or stainless steel)\u003c\/li\u003e\n\u003cli data-section-id=\"19m0bnj\" data-start=\"2833\" data-end=\"2882\"\u003eInstallation environment and protection level\u003c\/li\u003e\n\u003cli data-section-id=\"1j6u5c6\" data-start=\"2883\" data-end=\"2937\"\u003eOutput requirements (4–20mA \/ digital communication)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2939\" data-end=\"2942\"\u003e\n\u003ch1 data-section-id=\"a0z7dm\" data-start=\"2944\" data-end=\"2958\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"2960\" data-end=\"3143\"\u003e\u003cstrong data-start=\"2960\" data-end=\"3001\"\u003eQ: What is Liquiline M CM42 used for?\u003c\/strong\u003e\u003cbr data-start=\"3001\" data-end=\"3004\"\u003eA: It is used for industrial liquid analysis including pH, ORP, conductivity, and oxygen measurement. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3145\" data-end=\"3297\"\u003e\u003cstrong data-start=\"3145\" data-end=\"3187\"\u003eQ: Does CM42 support Memosens sensors?\u003c\/strong\u003e\u003cbr data-start=\"3187\" data-end=\"3190\"\u003eA: Yes. It supports both Memosens digital sensors and analog sensors. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3299\" data-end=\"3458\"\u003e\u003cstrong data-start=\"3299\" data-end=\"3340\"\u003eQ: Can it be used in hazardous areas?\u003c\/strong\u003e\u003cbr data-start=\"3340\" data-end=\"3343\"\u003eA: Yes. It includes multiple hazardous area approvals such as ATEX and IECEx. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3460\" data-end=\"3612\"\u003e\u003cstrong data-start=\"3460\" data-end=\"3511\"\u003eQ: Which communication protocols are available?\u003c\/strong\u003e\u003cbr data-start=\"3511\" data-end=\"3514\"\u003eA: HART, PROFIBUS PA, and FOUNDATION Fieldbus are supported. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3614\" data-end=\"3777\"\u003e\u003cstrong data-start=\"3614\" data-end=\"3677\"\u003eQ: Is it suitable for food and pharmaceutical applications?\u003c\/strong\u003e\u003cbr data-start=\"3677\" data-end=\"3680\"\u003eA: Yes. It is widely used in hygienic process environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3779\" data-end=\"3917\"\u003e\u003cstrong data-start=\"3779\" data-end=\"3826\"\u003eQ: What protection level does CM42 provide?\u003c\/strong\u003e\u003cbr data-start=\"3826\" data-end=\"3829\"\u003eA: IP66\/IP67 and NEMA 4X protection are available. \u003cspan class=\"\" data-state=\"delayed-open\" aria-describedby=\"radix-_r_ap_\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325678026813,"sku":null,"price":1450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/liquiline-cm42-liquid-analysis-transmitter-product-view.png?v=1783304252"},{"product_id":"e-h-itherm-surfaceline-tm611-surface-thermometer","title":"Endress+Hauser iTHERM SurfaceLine TM611 Surface Thermometer","description":"\u003cp data-start=\"974\" data-end=\"989\"\u003eSelection Notes\u003c\/p\u003e\n\u003cp data-start=\"991\" data-end=\"1372\"\u003e• Confirm if a non‑invasive surface thermometer is preferable to an invasive thermowell solution\u003cbr data-start=\"1087\" data-end=\"1090\"\u003e• Evaluate pipe material and insulation requirements for optimal thermal coupling\u003cbr data-start=\"1171\" data-end=\"1174\"\u003e• Understand that advanced thermal coupling element ensures high accuracy similar to invasive devices\u003cbr data-start=\"1275\" data-end=\"1278\"\u003e• Ideal for standard and demanding industrial environments with external pipe surface mounting\u003c\/p\u003e\n\u003cp data-start=\"1470\" data-end=\"1505\"\u003eWhy Choose iTHERM SurfaceLine TM611\u003c\/p\u003e\n\u003cp data-start=\"1507\" data-end=\"1990\"\u003e• Accurate and fast temperature measurement without process penetration\u003cbr data-start=\"1578\" data-end=\"1581\"\u003e• Eliminates leakage risk and flow disruption from thermowell installations\u003cbr data-start=\"1656\" data-end=\"1659\"\u003e• Cost and time savings in engineering, installation and certification\u003cbr data-start=\"1729\" data-end=\"1732\"\u003e• Easy subsequent installation on existing pipes with minimal plant downtime\u003cbr data-start=\"1808\" data-end=\"1811\"\u003e• Compatible with standard iTEMP temperature transmitters and communication protocols\u003cbr data-start=\"1896\" data-end=\"1899\"\u003e• Suitable across heavy industries including chemical, energy, hydrogen, HVAC and utilities\u003c\/p\u003e\n\u003cp data-start=\"2126\" data-end=\"2129\"\u003eFAQ\u003c\/p\u003e\n\u003cp data-start=\"2131\" data-end=\"2379\"\u003eQ: How does a non‑invasive thermometer compare to an invasive sensor?\u003cbr data-start=\"2200\" data-end=\"2203\"\u003eA: iTHERM SurfaceLine TM611 offers accuracy and response time comparable to invasive thermometers without the need for process penetration.\u003c\/p\u003e\n\u003cp data-start=\"2381\" data-end=\"2574\"\u003eQ: Does TM611 require insulation on the pipe surface?\u003cbr data-start=\"2434\" data-end=\"2437\"\u003eA: Proper insulation of the measuring point helps minimize ambient influences and improves accuracy.\u003c\/p\u003e\n\u003cp data-start=\"2576\" data-end=\"2746\"\u003eQ: Can this thermometer be used on any pipe size?\u003cbr data-start=\"2625\" data-end=\"2628\"\u003eA: Yes — versions are available for a wide range of pipe diameters and materials.\u003c\/p\u003e\n\u003cp data-start=\"2748\" data-end=\"2961\"\u003eQ: Is this suitable for retrofitting existing installations?\u003cbr data-start=\"2808\" data-end=\"2811\"\u003eA: Yes — it’s designed specifically to allow temperature measurement without cutting or opening the process line.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325717643325,"sku":null,"price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/tm611-surfaceline-product.webp?v=1783307514"},{"product_id":"endress-hauser-dosimag-5bh-successor-dosimag-d5ab-electromagnetic-flowmeter","title":"Endress Hauser Dosimag 5BH (successor-Dosimag D5AB) electromagnetic flowmeter","description":"\u003ch3 data-section-id=\"uztocl\" data-start=\"1153\" data-end=\"1172\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1174\" data-end=\"1762\"\u003e• Confirm that the \u003cstrong data-start=\"1193\" data-end=\"1230\"\u003eliquid is electrically conductive\u003c\/strong\u003e, which is required for electromagnetic measurement\u003cbr data-start=\"1281\" data-end=\"1284\"\u003e• Verify the \u003cstrong data-start=\"1297\" data-end=\"1311\"\u003eflow range\u003c\/strong\u003e, typically from \u003cstrong data-start=\"1328\" data-end=\"1348\"\u003e0.14 to 1.66 l\/s\u003c\/strong\u003e depending on configuration \u003cbr data-start=\"1413\" data-end=\"1416\"\u003e• Choose the correct \u003cstrong data-start=\"1437\" data-end=\"1460\"\u003ehygienic connection\u003c\/strong\u003e, such as Tri-Clamp or threaded fittings\u003cbr data-start=\"1500\" data-end=\"1503\"\u003e• Check the \u003cstrong data-start=\"1515\" data-end=\"1538\"\u003eprocess temperature\u003c\/strong\u003e, up to \u003cstrong data-start=\"1546\" data-end=\"1588\"\u003e130 °C (or 150 °C with specific seals)\u003c\/strong\u003e \u003cbr data-start=\"1626\" data-end=\"1629\"\u003e• In addition, ensure compliance with \u003cstrong data-start=\"1667\" data-end=\"1689\"\u003ehygienic standards\u003c\/strong\u003e such as EHEDG or 3-A if required\u003c\/p\u003e\n\u003ch3 data-section-id=\"1i6n91o\" data-start=\"1797\" data-end=\"1828\"\u003eWhy Choose the Dosimag D5AB\u003c\/h3\u003e\n\u003cp data-start=\"1830\" data-end=\"2055\"\u003e• \u003cstrong data-start=\"1832\" data-end=\"1876\"\u003eHigh Repeatability for Filling Processes\u003c\/strong\u003e\u003cbr data-start=\"1876\" data-end=\"1879\"\u003eThe sensor delivers repeatability up to \u003cstrong data-start=\"1919\" data-end=\"1940\"\u003e±0.25% of reading\u003c\/strong\u003e. Therefore, it ensures consistent filling accuracy in dosing applications.\u003c\/p\u003e\n\u003cp data-start=\"2057\" data-end=\"2274\"\u003e• \u003cstrong data-start=\"2059\" data-end=\"2101\"\u003eHygienic Design with Full Cleanability\u003c\/strong\u003e\u003cbr data-start=\"2101\" data-end=\"2104\"\u003eThe fully welded housing and smooth surfaces support \u003cstrong data-start=\"2157\" data-end=\"2181\"\u003eCIP and SIP cleaning\u003c\/strong\u003e. As a result, it meets strict hygienic requirements.\u003c\/p\u003e\n\u003cp data-start=\"2276\" data-end=\"2476\"\u003e• \u003cstrong data-start=\"2278\" data-end=\"2319\"\u003eCompact and Space-Saving Construction\u003c\/strong\u003e\u003cbr data-start=\"2319\" data-end=\"2322\"\u003eIts ultra-compact design reduces installation space. Consequently, it is ideal for skid systems and OEM equipment.\u003c\/p\u003e\n\u003cp data-start=\"2478\" data-end=\"2701\"\u003e• \u003cstrong data-start=\"2480\" data-end=\"2531\"\u003eNo Pressure Loss and Maintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"2531\" data-end=\"2534\"\u003eThe flowmeter has no internal obstructions or moving parts. This design eliminates pressure loss and reduces maintenance needs.\u003c\/p\u003e\n\u003cp data-start=\"2703\" data-end=\"2951\"\u003e• \u003cstrong data-start=\"2705\" data-end=\"2754\"\u003eIntegrated Batching and Digital Communication\u003c\/strong\u003e\u003cbr data-start=\"2754\" data-end=\"2757\"\u003eOptional features include \u003cstrong data-start=\"2783\" data-end=\"2819\"\u003eIO-Link and Modbus communication\u003c\/strong\u003e. In addition, integrated batching functions improve filling control and process efficiency.\u003c\/p\u003e\n\u003cp data-start=\"2953\" data-end=\"3143\"\u003e• \u003cstrong data-start=\"2955\" data-end=\"2993\"\u003eHigh Chemical Resistance Materials\u003c\/strong\u003e\u003cbr data-start=\"2993\" data-end=\"2996\"\u003eWith \u003cstrong data-start=\"3001\" data-end=\"3050\"\u003ePFA lining and corrosion-resistant electrodes\u003c\/strong\u003e, the device performs reliably in aggressive media.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3181\" data-end=\"3188\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3190\" data-end=\"3423\"\u003e\u003cstrong data-start=\"3190\" data-end=\"3247\"\u003eQ: What applications is Dosimag D5AB best suited for?\u003c\/strong\u003e\u003cbr data-start=\"3247\" data-end=\"3250\"\u003eA: It is designed for \u003cstrong data-start=\"3272\" data-end=\"3314\"\u003efilling, dosing and bottling processes\u003c\/strong\u003e in hygienic industries such as food, beverage and pharmaceuticals.\u003c\/p\u003e\n\u003cp data-start=\"3425\" data-end=\"3593\"\u003e\u003cstrong data-start=\"3425\" data-end=\"3466\"\u003eQ: What is the measurement principle?\u003c\/strong\u003e\u003cbr data-start=\"3466\" data-end=\"3469\"\u003eA: It uses \u003cstrong data-start=\"3480\" data-end=\"3539\"\u003eelectromagnetic flow measurement based on Faraday’s law\u003c\/strong\u003e, ensuring accuracy independent of fluid properties.\u003c\/p\u003e\n\u003cp data-start=\"3595\" data-end=\"3782\"\u003e\u003cstrong data-start=\"3595\" data-end=\"3637\"\u003eQ: Does it support hygienic standards?\u003c\/strong\u003e\u003cbr data-start=\"3637\" data-end=\"3640\"\u003eA: Yes. The device complies with \u003cstrong data-start=\"3673\" data-end=\"3708\"\u003eEHEDG, 3-A and FDA requirements\u003c\/strong\u003e, and supports CIP\/SIP cleaning.\u003c\/p\u003e\n\u003cp data-start=\"3784\" data-end=\"3963\"\u003e\u003cstrong data-start=\"3784\" data-end=\"3832\"\u003eQ: What communication options are available?\u003c\/strong\u003e\u003cbr data-start=\"3832\" data-end=\"3835\"\u003eA: It supports \u003cstrong data-start=\"3850\" data-end=\"3892\"\u003epulse output, IO-Link and Modbus RS485\u003c\/strong\u003e, depending on configuration.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325721870397,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/dosimag-5bh-flowmeter-overview.webp?v=1783308015"},{"product_id":"e-h-55s-proline-promag-55s-electromagnetic-flowmeter","title":"Endress+Hauser 55S Proline Promag 55S electromagnetic flowmeter","description":"\u003ch3 data-section-id=\"uztocl\" data-start=\"1148\" data-end=\"1167\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1169\" data-end=\"1833\"\u003e• Confirm that the \u003cstrong data-start=\"1188\" data-end=\"1232\"\u003emedium is conductive and contains solids\u003c\/strong\u003e, as this model is optimized for such conditions\u003cbr data-start=\"1280\" data-end=\"1283\"\u003e• Verify the \u003cstrong data-start=\"1296\" data-end=\"1310\"\u003eflow range\u003c\/strong\u003e, typically from \u003cstrong data-start=\"1327\" data-end=\"1355\"\u003e0.06 dm³\/min to 600 m³\/h\u003c\/strong\u003e \u003cbr data-start=\"1393\" data-end=\"1396\"\u003e• Choose the correct \u003cstrong data-start=\"1417\" data-end=\"1435\"\u003eliner material\u003c\/strong\u003e (e.g., polyurethane, rubber, PTFE) based on abrasion and chemical resistance \u003cbr data-start=\"1550\" data-end=\"1553\"\u003e• Check the \u003cstrong data-start=\"1565\" data-end=\"1588\"\u003eprocess temperature\u003c\/strong\u003e, which can reach up to \u003cstrong data-start=\"1612\" data-end=\"1622\"\u003e180 °C\u003c\/strong\u003e depending on configuration \u003cbr data-start=\"1687\" data-end=\"1690\"\u003e• In addition, ensure the \u003cstrong data-start=\"1716\" data-end=\"1735\"\u003epressure rating\u003c\/strong\u003e (up to PN40 \/ Class 300) matches your system requirements\u003c\/p\u003e\n\u003ch3 data-section-id=\"16zb9td\" data-start=\"1868\" data-end=\"1897\"\u003eWhy Choose the Promag 55S\u003c\/h3\u003e\n\u003cp data-start=\"1899\" data-end=\"2128\"\u003e• \u003cstrong data-start=\"1901\" data-end=\"1948\"\u003eDesigned for Abrasive and High-Solids Media\u003c\/strong\u003e\u003cbr data-start=\"1948\" data-end=\"1951\"\u003eThis model is specifically built for \u003cstrong data-start=\"1988\" data-end=\"2023\"\u003eslurry and solids-laden liquids\u003c\/strong\u003e. Therefore, it performs reliably where standard flowmeters fail.\u003c\/p\u003e\n\u003cp data-start=\"2130\" data-end=\"2347\"\u003e• \u003cstrong data-start=\"2132\" data-end=\"2173\"\u003eIntegrated Solids Content Measurement\u003c\/strong\u003e\u003cbr data-start=\"2173\" data-end=\"2176\"\u003eThe transmitter can calculate \u003cstrong data-start=\"2206\" data-end=\"2230\"\u003esolids concentration\u003c\/strong\u003e in addition to flow. As a result, process monitoring becomes more efficient.\u003c\/p\u003e\n\u003cp data-start=\"2349\" data-end=\"2578\"\u003e• \u003cstrong data-start=\"2351\" data-end=\"2399\"\u003eExcellent Durability with Specialized Liners\u003c\/strong\u003e\u003cbr data-start=\"2399\" data-end=\"2402\"\u003eA wide range of liner materials improves resistance to wear and corrosion. Consequently, service life is extended in harsh environments.\u003c\/p\u003e\n\u003cp data-start=\"2580\" data-end=\"2822\"\u003e• \u003cstrong data-start=\"2582\" data-end=\"2637\"\u003eStable Measurement \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2580\" data-end=\"2822\"\u003e\u003cstrong data-start=\"2582\" data-end=\"2637\"\u003eIndependent of Process Variables\u003c\/strong\u003e\u003cbr data-start=\"2637\" data-end=\"2640\"\u003eThe electromagnetic principle is unaffected by density, viscosity or pressure. Therefore, measurement remains stable under varying conditions.\u003c\/p\u003e\n\u003cp data-start=\"2824\" data-end=\"3001\"\u003e• \u003cstrong data-start=\"2826\" data-end=\"2856\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"2856\" data-end=\"2859\"\u003eThere are no moving parts inside the sensor. This design reduces maintenance and minimizes downtime.\u003c\/p\u003e\n\u003cp data-start=\"3003\" data-end=\"3215\"\u003e• \u003cstrong data-start=\"3005\" data-end=\"3047\"\u003eAdvanced Communication and Diagnostics\u003c\/strong\u003e\u003cbr data-start=\"3047\" data-end=\"3050\"\u003eIt supports \u003cstrong data-start=\"3062\" data-end=\"3110\"\u003eHART, PROFIBUS PA\/DP and FOUNDATION Fieldbus\u003c\/strong\u003e. In addition, built-in diagnostics improve operational safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3253\" data-end=\"3260\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3262\" data-end=\"3505\"\u003e\u003cstrong data-start=\"3262\" data-end=\"3330\"\u003eQ: What makes Promag 55S different from standard mag flowmeters?\u003c\/strong\u003e\u003cbr data-start=\"3330\" data-end=\"3333\"\u003eA: It is specifically designed for \u003cstrong data-start=\"3368\" data-end=\"3402\"\u003eabrasive and high-solids media\u003c\/strong\u003e, with enhanced durability and solids measurement capability.\u003c\/p\u003e\n\u003cp data-start=\"3507\" data-end=\"3699\"\u003e\u003cstrong data-start=\"3507\" data-end=\"3558\"\u003eQ: What industries commonly use this flowmeter?\u003c\/strong\u003e\u003cbr data-start=\"3558\" data-end=\"3561\"\u003eA: It is widely used in \u003cstrong data-start=\"3585\" data-end=\"3656\"\u003emining, wastewater treatment, pulp and paper, and metals processing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3701\" data-end=\"3872\"\u003e\u003cstrong data-start=\"3701\" data-end=\"3741\"\u003eQ: What is the measurement accuracy?\u003c\/strong\u003e\u003cbr data-start=\"3741\" data-end=\"3744\"\u003eA: Standard accuracy is \u003cstrong data-start=\"3768\" data-end=\"3788\"\u003e±0.5% of reading\u003c\/strong\u003e, with optional higher accuracy available.\u003c\/p\u003e\n\u003cp data-start=\"3874\" data-end=\"4034\"\u003e\u003cstrong data-start=\"3874\" data-end=\"3909\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-start=\"3909\" data-end=\"3912\"\u003eA: No. Because it has \u003cstrong data-start=\"3934\" data-end=\"3953\"\u003eno moving parts\u003c\/strong\u003e, maintenance requirements are minimal.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325742940221,"sku":null,"price":1350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-55s-electromagnetic-flowmeter1.webp?v=1783407998"},{"product_id":"e-h-dma-picomag-inline-electromagnetic-flowmeter","title":"Endress+Hauser DMA Picomag Inline electromagnetic flowmeter","description":"\u003cp data-start=\"250\" data-end=\"616\"\u003eThe \u003cstrong data-start=\"254\" data-end=\"326\"\u003eEndress+Hauser Picomag Inline electromagnetic flowmeter (DMA series)\u003c\/strong\u003e is a compact and versatile flowmeter designed for \u003cstrong data-start=\"377\" data-end=\"448\"\u003eprocess monitoring and utility applications with conductive liquids\u003c\/strong\u003e. It combines \u003cstrong data-start=\"462\" data-end=\"512\"\u003eflow, temperature and conductivity measurement\u003c\/strong\u003e in a single device, reducing the need for multiple instruments.\u003c\/p\u003e\n\u003cp data-start=\"618\" data-end=\"892\"\u003eThis device features a fully integrated design with sensor and transmitter in one housing. In addition, it supports \u003cstrong data-start=\"734\" data-end=\"783\"\u003eBluetooth configuration via the SmartBlue app\u003c\/strong\u003e, allowing fast and convenient setup even in hard-to-reach locations.\u003c\/p\u003e\n\u003cp data-start=\"894\" data-end=\"1006\"\u003eTypical applications include cooling water circuits, skid systems, utilities and general industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"1008\" data-end=\"1136\"\u003eNot Recommended For:\u003cbr data-start=\"1028\" data-end=\"1031\"\u003e• Non-conductive liquids such as oil or gas\u003cbr data-start=\"1074\" data-end=\"1077\"\u003e• High-temperature or high-pressure primary process lines\u003c\/p\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1171\" data-end=\"1190\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1192\" data-end=\"1788\"\u003e• Confirm that the \u003cstrong data-start=\"1211\" data-end=\"1248\"\u003emedium is electrically conductive\u003c\/strong\u003e, as required for electromagnetic measurement\u003cbr data-start=\"1293\" data-end=\"1296\"\u003e• Verify the \u003cstrong data-start=\"1309\" data-end=\"1323\"\u003eflow range\u003c\/strong\u003e, which can reach up to \u003cstrong data-start=\"1347\" data-end=\"1360\"\u003e750 L\/min\u003c\/strong\u003e depending on size \u003cbr data-start=\"1416\" data-end=\"1419\"\u003e• Check the \u003cstrong data-start=\"1431\" data-end=\"1454\"\u003eprocess temperature\u003c\/strong\u003e, typically \u003cstrong data-start=\"1466\" data-end=\"1486\"\u003e-10 °C to +70 °C\u003c\/strong\u003e (short-term up to 85 °C) \u003cbr data-start=\"1549\" data-end=\"1552\"\u003e• Ensure the \u003cstrong data-start=\"1565\" data-end=\"1585\"\u003eprocess pressure\u003c\/strong\u003e does not exceed \u003cstrong data-start=\"1602\" data-end=\"1612\"\u003e16 bar\u003c\/strong\u003e \u003cbr data-start=\"1650\" data-end=\"1653\"\u003e• In addition, confirm compatibility with \u003cstrong data-start=\"1695\" data-end=\"1725\"\u003eIO-Link or digital outputs\u003c\/strong\u003e for system integration\u003c\/p\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1171\" data-end=\"1190\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1192\" data-end=\"1788\"\u003e• Confirm that the \u003cstrong data-start=\"1211\" data-end=\"1248\"\u003emedium is electrically conductive\u003c\/strong\u003e, as required for electromagnetic measurement\u003cbr data-start=\"1293\" data-end=\"1296\"\u003e• Verify the \u003cstrong data-start=\"1309\" data-end=\"1323\"\u003eflow range\u003c\/strong\u003e, which can reach up to \u003cstrong data-start=\"1347\" data-end=\"1360\"\u003e750 L\/min\u003c\/strong\u003e depending on size \u003cbr data-start=\"1416\" data-end=\"1419\"\u003e• Check the \u003cstrong data-start=\"1431\" data-end=\"1454\"\u003eprocess temperature\u003c\/strong\u003e, typically \u003cstrong data-start=\"1466\" data-end=\"1486\"\u003e-10 °C to +70 °C\u003c\/strong\u003e (short-term up to 85 °C) \u003cbr data-start=\"1549\" data-end=\"1552\"\u003e• Ensure the \u003cstrong data-start=\"1565\" data-end=\"1585\"\u003eprocess pressure\u003c\/strong\u003e does not exceed \u003cstrong data-start=\"1602\" data-end=\"1612\"\u003e16 bar\u003c\/strong\u003e \u003cbr data-start=\"1650\" data-end=\"1653\"\u003e• In addition, confirm compatibility with \u003cstrong data-start=\"1695\" data-end=\"1725\"\u003eIO-Link or digital outputs\u003c\/strong\u003e for system integration\u003c\/p\u003e\n\u003ch3 data-section-id=\"f42xgj\" data-start=\"1823\" data-end=\"1859\"\u003eWhy Choose the Picomag Flowmeter\u003c\/h3\u003e\n\u003cp data-start=\"1861\" data-end=\"2070\"\u003e• \u003cstrong data-start=\"1863\" data-end=\"1896\"\u003e3-in-1 Measurement Capability\u003c\/strong\u003e\u003cbr data-start=\"1896\" data-end=\"1899\"\u003eThe device measures \u003cstrong data-start=\"1919\" data-end=\"1972\"\u003eflow, temperature and conductivity simultaneously\u003c\/strong\u003e. Therefore, fewer instruments are required in the system.\u003c\/p\u003e\n\u003cp data-start=\"2072\" data-end=\"2268\"\u003e• \u003cstrong data-start=\"2074\" data-end=\"2103\"\u003eCompact All-in-One Design\u003c\/strong\u003e\u003cbr data-start=\"2103\" data-end=\"2106\"\u003eSensor and transmitter are integrated into one housing. As a result, installation space and wiring complexity are reduced.\u003c\/p\u003e\n\u003cp data-start=\"2270\" data-end=\"2489\"\u003e• \u003cstrong data-start=\"2272\" data-end=\"2308\"\u003eEasy Commissioning via Bluetooth\u003c\/strong\u003e\u003cbr data-start=\"2308\" data-end=\"2311\"\u003eConfiguration can be completed using the SmartBlue app. In addition, wireless access simplifies setup in difficult installation positions.\u003c\/p\u003e\n\u003cp data-start=\"2491\" data-end=\"2739\"\u003e• \u003cstrong data-start=\"2493\" data-end=\"2551\"\u003eReliable Measurement Independent of Process Conditions\u003c\/strong\u003e\u003cbr data-start=\"2551\" data-end=\"2554\"\u003eThe electromagnetic principle is unaffected by density, viscosity or pressure. Consequently, measurement remains stable under varying conditions.\u003c\/p\u003e\n\u003cp data-start=\"2741\" data-end=\"2959\"\u003e• \u003cstrong data-start=\"2743\" data-end=\"2780\"\u003eFlexible Integration with IO-Link\u003c\/strong\u003e\u003cbr data-start=\"2780\" data-end=\"2783\"\u003eThe flowmeter supports \u003cstrong data-start=\"2806\" data-end=\"2842\"\u003eIO-Link and multiple I\/O options\u003c\/strong\u003e. Therefore, integration into modern automation systems is straightforward.\u003c\/p\u003e\n\u003cp data-start=\"2961\" data-end=\"3165\"\u003e• \u003cstrong data-start=\"2963\" data-end=\"2991\"\u003eRobust Industrial Design\u003c\/strong\u003e\u003cbr data-start=\"2991\" data-end=\"2994\"\u003eIt offers \u003cstrong data-start=\"3004\" data-end=\"3028\"\u003eIP65\/IP67 protection\u003c\/strong\u003e and strong vibration resistance. This ensures reliable performance in industrial environments.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325752737853,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/picomag-dma-inline-flowmeter.webp?v=1783309621"},{"product_id":"e-h-d5ab-dosimag-electromagnetic-flowmeter","title":"Endress+Hauser D5AB Dosimag electromagnetic flowmeter","description":"\u003cp data-start=\"275\" data-end=\"602\"\u003eThe \u003cstrong data-start=\"279\" data-end=\"310\"\u003eEndress+Hauser Dosimag D5AB\u003c\/strong\u003e is a compact electromagnetic flowmeter designed for \u003cstrong data-start=\"363\" data-end=\"413\"\u003ehigh-precision filling and dosing applications\u003c\/strong\u003e in hygienic industries. It features a \u003cstrong data-start=\"452\" data-end=\"492\"\u003efully welded stainless-steel housing\u003c\/strong\u003e, which ensures durability and easy cleaning in sanitary environments.\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"881\"\u003eThis flowmeter provides \u003cstrong data-start=\"628\" data-end=\"675\"\u003eexceptional repeatability and fast response\u003c\/strong\u003e, making it ideal for bottling, batching and dosing processes. In addition, the electromagnetic measuring principle is independent of pressure, density and viscosity.\u003c\/p\u003e\n\u003cp data-start=\"883\" data-end=\"995\"\u003eTypical applications include food \u0026amp; beverage production, pharmaceuticals and life sciences processing systems.\u003c\/p\u003e\n\u003cp data-start=\"997\" data-end=\"1118\"\u003eNot Recommended For:\u003cbr data-start=\"1017\" data-end=\"1020\"\u003e• Non-conductive liquids such as oils or gases\u003cbr data-start=\"1066\" data-end=\"1069\"\u003e• Large pipe systems requiring high flow ranges\u003c\/p\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1153\" data-end=\"1172\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1174\" data-end=\"1762\"\u003e• Confirm that the \u003cstrong data-start=\"1193\" data-end=\"1230\"\u003eliquid is electrically conductive\u003c\/strong\u003e, which is required for electromagnetic measurement\u003cbr data-start=\"1281\" data-end=\"1284\"\u003e• Verify the \u003cstrong data-start=\"1297\" data-end=\"1311\"\u003eflow range\u003c\/strong\u003e, typically from \u003cstrong data-start=\"1328\" data-end=\"1348\"\u003e0.14 to 1.66 l\/s\u003c\/strong\u003e depending on configuration\u003cbr data-start=\"1413\" data-end=\"1416\"\u003e• Choose the correct \u003cstrong data-start=\"1437\" data-end=\"1460\"\u003ehygienic connection\u003c\/strong\u003e, such as Tri-Clamp or threaded fittings\u003cbr data-start=\"1500\" data-end=\"1503\"\u003e• Check the \u003cstrong data-start=\"1515\" data-end=\"1538\"\u003eprocess temperature\u003c\/strong\u003e, up to \u003cstrong data-start=\"1546\" data-end=\"1588\"\u003e130 °C (or 150 °C with specific seals)\u003c\/strong\u003e\u003cbr data-start=\"1626\" data-end=\"1629\"\u003e• In addition, ensure compliance with \u003cstrong data-start=\"1667\" data-end=\"1689\"\u003ehygienic standards\u003c\/strong\u003e such as EHEDG or 3-A if required\u003c\/p\u003e\n\u003ch3 data-section-id=\"1i6n91o\" data-start=\"1797\" data-end=\"1828\"\u003eWhy Choose the Dosimag D5AB\u003c\/h3\u003e\n\u003cp data-start=\"1830\" data-end=\"2055\"\u003e• \u003cstrong data-start=\"1832\" data-end=\"1876\"\u003eHigh Repeatability for Filling Processes\u003c\/strong\u003e\u003cbr data-start=\"1876\" data-end=\"1879\"\u003eThe sensor delivers repeatability up to \u003cstrong data-start=\"1919\" data-end=\"1940\"\u003e±0.25% of reading\u003c\/strong\u003e. Therefore, it ensures consistent filling accuracy in dosing applications.\u003c\/p\u003e\n\u003cp data-start=\"2057\" data-end=\"2274\"\u003e• \u003cstrong data-start=\"2059\" data-end=\"2101\"\u003eHygienic Design with Full Cleanability\u003c\/strong\u003e\u003cbr data-start=\"2101\" data-end=\"2104\"\u003eThe fully welded housing and smooth surfaces support \u003cstrong data-start=\"2157\" data-end=\"2181\"\u003eCIP and SIP cleaning\u003c\/strong\u003e. As a result, it meets strict hygienic requirements.\u003c\/p\u003e\n\u003cp data-start=\"2276\" data-end=\"2476\"\u003e• \u003cstrong data-start=\"2278\" data-end=\"2319\"\u003eCompact and Space-Saving Construction\u003c\/strong\u003e\u003cbr data-start=\"2319\" data-end=\"2322\"\u003eIts ultra-compact design reduces installation space. Consequently, it is ideal for skid systems and OEM equipment.\u003c\/p\u003e\n\u003cp data-start=\"2478\" data-end=\"2701\"\u003e• \u003cstrong data-start=\"2480\" data-end=\"2531\"\u003eNo Pressure Loss and Maintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"2531\" data-end=\"2534\"\u003eThe flowmeter has no internal obstructions or moving parts. This design eliminates pressure loss and reduces maintenance needs.\u003c\/p\u003e\n\u003cp data-start=\"2703\" data-end=\"2951\"\u003e• \u003cstrong data-start=\"2705\" data-end=\"2754\"\u003eIntegrated Batching and Digital Communication\u003c\/strong\u003e\u003cbr data-start=\"2754\" data-end=\"2757\"\u003eOptional features include \u003cstrong data-start=\"2783\" data-end=\"2819\"\u003eIO-Link and Modbus communication\u003c\/strong\u003e. In addition, integrated batching functions improve filling control and process efficiency.\u003c\/p\u003e\n\u003cp data-start=\"2953\" data-end=\"3143\"\u003e• \u003cstrong data-start=\"2955\" data-end=\"2993\"\u003eHigh Chemical Resistance Materials\u003c\/strong\u003e\u003cbr data-start=\"2993\" data-end=\"2996\"\u003eWith \u003cstrong data-start=\"3001\" data-end=\"3050\"\u003ePFA lining and corrosion-resistant electrodes\u003c\/strong\u003e, the device performs reliably in aggressive media.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3181\" data-end=\"3188\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3190\" data-end=\"3423\"\u003e\u003cstrong data-start=\"3190\" data-end=\"3247\"\u003eQ: What applications is Dosimag D5AB best suited for?\u003c\/strong\u003e\u003cbr data-start=\"3247\" data-end=\"3250\"\u003eA: It is designed for \u003cstrong data-start=\"3272\" data-end=\"3314\"\u003efilling, dosing and bottling processes\u003c\/strong\u003e in hygienic industries such as food, beverage and pharmaceuticals.\u003c\/p\u003e\n\u003cp data-start=\"3425\" data-end=\"3593\"\u003e\u003cstrong data-start=\"3425\" data-end=\"3466\"\u003eQ: What is the measurement principle?\u003c\/strong\u003e\u003cbr data-start=\"3466\" data-end=\"3469\"\u003eA: It uses \u003cstrong data-start=\"3480\" data-end=\"3539\"\u003eelectromagnetic flow measurement based on Faraday’s law\u003c\/strong\u003e, ensuring accuracy independent of fluid properties.\u003c\/p\u003e\n\u003cp data-start=\"3595\" data-end=\"3782\"\u003e\u003cstrong data-start=\"3595\" data-end=\"3637\"\u003eQ: Does it support hygienic standards?\u003c\/strong\u003e\u003cbr data-start=\"3637\" data-end=\"3640\"\u003eA: Yes. The device complies with \u003cstrong data-start=\"3673\" data-end=\"3708\"\u003eEHEDG, 3-A and FDA requirements\u003c\/strong\u003e, and supports CIP\/SIP cleaning.\u003c\/p\u003e\n\u003cp data-start=\"3784\" data-end=\"3963\"\u003e\u003cstrong data-start=\"3784\" data-end=\"3832\"\u003eQ: What communication options are available?\u003c\/strong\u003e\u003cbr data-start=\"3832\" data-end=\"3835\"\u003eA: It supports \u003cstrong data-start=\"3850\" data-end=\"3892\"\u003epulse output, IO-Link and Modbus RS485\u003c\/strong\u003e, depending on configuration.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325754507325,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/dosimag-d5ab-flowmeter-overview.webp?v=1783309954"},{"product_id":"e-h-proline-promag-w-10-5wbb-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag W 10 5WBB electromagnetic flowmeter","description":"\u003cp data-start=\"361\" data-end=\"620\"\u003eThe \u003cstrong data-start=\"365\" data-end=\"421\"\u003eProline Promag W 10 (5WBB) Electromagnetic Flowmeter\u003c\/strong\u003e provides reliable and accurate \u003cstrong data-start=\"453\" data-end=\"511\"\u003eflow measurement for water and wastewater applications\u003c\/strong\u003e. It uses \u003cstrong data-start=\"521\" data-end=\"563\"\u003eelectromagnetic measurement technology\u003c\/strong\u003e, which ensures stable performance without pressure loss.\u003c\/p\u003e\n\u003cp data-start=\"622\" data-end=\"938\"\u003eThis flowmeter is ideal for \u003cstrong data-start=\"650\" data-end=\"728\"\u003emunicipal water supply, wastewater treatment, and industrial water systems\u003c\/strong\u003e. In addition, it performs well in applications with varying flow conditions and suspended solids. Thanks to its \u003cstrong data-start=\"841\" data-end=\"879\"\u003erobust design and simple operation\u003c\/strong\u003e, it offers long-term reliability with minimal maintenance.\u003c\/p\u003e\n\u003cp data-start=\"940\" data-end=\"1041\"\u003eNot Recommended For:\u003cbr data-start=\"960\" data-end=\"963\"\u003e• Non-conductive liquids (e.g., oils, gases)\u003cbr data-start=\"1007\" data-end=\"1010\"\u003e• Very low conductivity media\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1089\" data-end=\"1107\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1109\" data-end=\"1275\"\u003e• \u003cstrong data-start=\"1111\" data-end=\"1136\"\u003eMeasurement Principle\u003c\/strong\u003e: The device uses \u003cstrong data-start=\"1154\" data-end=\"1190\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e, which requires conductive liquids. Ensure the medium has sufficient conductivity.\u003c\/p\u003e\n\u003cp data-start=\"1277\" data-end=\"1406\"\u003e• \u003cstrong data-start=\"1279\" data-end=\"1299\"\u003eApplication Type\u003c\/strong\u003e: It is designed for \u003cstrong data-start=\"1320\" data-end=\"1357\"\u003ewater and wastewater applications\u003c\/strong\u003e, including drinking water, sewage, and sludge.\u003c\/p\u003e\n\u003cp data-start=\"1408\" data-end=\"1546\"\u003e• \u003cstrong data-start=\"1410\" data-end=\"1440\"\u003ePipe Size and Installation\u003c\/strong\u003e: Select the correct \u003cstrong data-start=\"1461\" data-end=\"1486\"\u003enominal diameter (DN)\u003c\/strong\u003e and confirm installation conditions for optimal accuracy.\u003c\/p\u003e\n\u003cp data-start=\"1548\" data-end=\"1666\"\u003e• \u003cstrong data-start=\"1550\" data-end=\"1572\"\u003eProcess Conditions\u003c\/strong\u003e: Verify \u003cstrong data-start=\"1581\" data-end=\"1641\"\u003etemperature, pressure, and lining material compatibility\u003c\/strong\u003e with your application.\u003c\/p\u003e\n\u003cp data-start=\"1668\" data-end=\"1789\"\u003e• \u003cstrong data-start=\"1670\" data-end=\"1698\"\u003eOutput and Communication\u003c\/strong\u003e: Ensure compatibility with your system, including \u003cstrong data-start=\"1749\" data-end=\"1786\"\u003epulse, analog, or digital outputs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1f7uvjo\" data-start=\"1835\" data-end=\"1872\"\u003eWhy Choose the Proline Promag W 10\u003c\/h2\u003e\n\u003cp data-start=\"1874\" data-end=\"2102\"\u003e• \u003cstrong data-start=\"1876\" data-end=\"1916\"\u003eAccurate Electromagnetic Measurement\u003c\/strong\u003e\u003cbr data-start=\"1916\" data-end=\"1919\"\u003eThe flowmeter uses \u003cstrong data-start=\"1938\" data-end=\"1984\"\u003eFaraday’s law of electromagnetic induction\u003c\/strong\u003e to measure flow. Therefore, it provides accurate readings independent of pressure, temperature, or density changes.\u003c\/p\u003e\n\u003cp data-start=\"2104\" data-end=\"2297\"\u003e• \u003cstrong data-start=\"2106\" data-end=\"2142\"\u003eOptimized for Water Applications\u003c\/strong\u003e\u003cbr data-start=\"2142\" data-end=\"2145\"\u003eIt is specifically designed for \u003cstrong data-start=\"2177\" data-end=\"2212\"\u003ewater and wastewater industries\u003c\/strong\u003e. As a result, it ensures reliable performance in municipal and industrial systems.\u003c\/p\u003e\n\u003cp data-start=\"2299\" data-end=\"2470\"\u003e• \u003cstrong data-start=\"2301\" data-end=\"2321\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-start=\"2321\" data-end=\"2324\"\u003eThe sensor has \u003cstrong data-start=\"2339\" data-end=\"2367\"\u003eno internal obstructions\u003c\/strong\u003e, so it does not cause pressure drop. This improves system efficiency and reduces energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"2472\" data-end=\"2652\"\u003e• \u003cstrong data-start=\"2474\" data-end=\"2503\"\u003eRobust and Durable Design\u003c\/strong\u003e\u003cbr data-start=\"2503\" data-end=\"2506\"\u003eThe device withstands \u003cstrong data-start=\"2528\" data-end=\"2550\"\u003eharsh environments\u003c\/strong\u003e, including corrosion, moisture, and outdoor installations. Therefore, it ensures long service life.\u003c\/p\u003e\n\u003cp data-start=\"2654\" data-end=\"2812\"\u003e• \u003cstrong data-start=\"2656\" data-end=\"2690\"\u003eEasy Operation and Maintenance\u003c\/strong\u003e\u003cbr data-start=\"2690\" data-end=\"2693\"\u003eSimple configuration and stable performance reduce maintenance needs. In addition, it lowers overall operating costs.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2872\" data-end=\"2878\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2880\" data-end=\"3060\"\u003e\u003cstrong data-start=\"2880\" data-end=\"2937\"\u003eQ: What types of liquids can the Promag W 10 measure?\u003c\/strong\u003e\u003cbr data-start=\"2937\" data-end=\"2940\"\u003eA: It measures \u003cstrong data-start=\"2955\" data-end=\"2977\"\u003econductive liquids\u003c\/strong\u003e, especially water, wastewater, and sludge. It is not suitable for oils or gases.\u003c\/p\u003e\n\u003cp data-start=\"3062\" data-end=\"3215\"\u003e\u003cstrong data-start=\"3062\" data-end=\"3113\"\u003eQ: Does it cause pressure loss in the pipeline?\u003c\/strong\u003e\u003cbr data-start=\"3113\" data-end=\"3116\"\u003eA: No. The electromagnetic measurement principle ensures \u003cstrong data-start=\"3173\" data-end=\"3212\"\u003eno obstruction and no pressure drop\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3217\" data-end=\"3376\"\u003e\u003cstrong data-start=\"3217\" data-end=\"3267\"\u003eQ: Is it suitable for wastewater applications?\u003c\/strong\u003e\u003cbr data-start=\"3267\" data-end=\"3270\"\u003eA: Yes. It is specifically designed for \u003cstrong data-start=\"3310\" data-end=\"3347\"\u003ewastewater and sludge measurement\u003c\/strong\u003e, even with solids present.\u003c\/p\u003e\n\u003cp data-start=\"3378\" data-end=\"3526\"\u003e\u003cstrong data-start=\"3378\" data-end=\"3417\"\u003eQ: How accurate is the measurement?\u003c\/strong\u003e\u003cbr data-start=\"3417\" data-end=\"3420\"\u003eA: The device provides \u003cstrong data-start=\"3443\" data-end=\"3483\"\u003ehigh accuracy and stable performance\u003c\/strong\u003e, even under fluctuating flow conditions.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43325763813437,"sku":null,"price":1000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-w10-5wbb-electromagnetic-flowmeter.webp?v=1783310406"},{"product_id":"e-h-proline-promag-w-800-5w8c-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag W 800 5W8C electromagnetic flowmeter","description":"\u003cp data-start=\"363\" data-end=\"666\"\u003eThe \u003cstrong data-start=\"367\" data-end=\"424\"\u003eProline Promag W 800 (5W8C) Electromagnetic Flowmeter\u003c\/strong\u003e is designed for \u003cstrong data-start=\"441\" data-end=\"503\"\u003ereliable flow measurement in water and wastewater networks\u003c\/strong\u003e, especially in \u003cstrong data-start=\"519\" data-end=\"562\"\u003eremote or difficult-to-access locations\u003c\/strong\u003e. It uses \u003cstrong data-start=\"572\" data-end=\"614\"\u003eelectromagnetic measurement technology\u003c\/strong\u003e, ensuring stable performance without pressure loss.\u003c\/p\u003e\n\u003cp data-start=\"668\" data-end=\"941\"\u003eThis model features \u003cstrong data-start=\"688\" data-end=\"753\"\u003ebattery-powered operation with optional GSM\/LTE communication\u003c\/strong\u003e, making it ideal for \u003cstrong data-start=\"775\" data-end=\"852\"\u003edistrict metering areas (DMA), leakage detection, and pipeline monitoring\u003c\/strong\u003e. In addition, its robust design supports long-term outdoor use with minimal maintenance.\u003c\/p\u003e\n\u003cp data-start=\"943\" data-end=\"1074\"\u003eNot Recommended For:\u003cbr data-start=\"963\" data-end=\"966\"\u003e• Non-conductive liquids (e.g., oils, gases)\u003cbr data-start=\"1010\" data-end=\"1013\"\u003e• Applications requiring continuous wired power supply only\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1122\" data-end=\"1140\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1142\" data-end=\"1278\"\u003e• \u003cstrong data-start=\"1144\" data-end=\"1169\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-start=\"1176\" data-end=\"1212\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e, which requires conductive liquids such as water or wastewater.\u003c\/p\u003e\n\u003cp data-start=\"1280\" data-end=\"1397\"\u003e• \u003cstrong data-start=\"1282\" data-end=\"1298\"\u003ePower Supply\u003c\/strong\u003e: Designed for \u003cstrong data-start=\"1313\" data-end=\"1342\"\u003ebattery-powered operation\u003c\/strong\u003e, ideal for remote installations without mains power.\u003c\/p\u003e\n\u003cp data-start=\"1399\" data-end=\"1524\"\u003e• \u003cstrong data-start=\"1401\" data-end=\"1426\"\u003eCommunication Options\u003c\/strong\u003e: Supports \u003cstrong data-start=\"1437\" data-end=\"1473\"\u003eGSM\/LTE remote data transmission\u003c\/strong\u003e, enabling real-time monitoring and data logging.\u003c\/p\u003e\n\u003cp data-start=\"1526\" data-end=\"1647\"\u003e• \u003cstrong data-start=\"1528\" data-end=\"1548\"\u003eApplication Type\u003c\/strong\u003e: Best suited for \u003cstrong data-start=\"1566\" data-end=\"1644\"\u003ewater distribution networks, leakage detection, and remote flow monitoring\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1649\" data-end=\"1778\"\u003e• \u003cstrong data-start=\"1651\" data-end=\"1680\"\u003eInstallation Requirements\u003c\/strong\u003e: Select the correct \u003cstrong data-start=\"1701\" data-end=\"1719\"\u003epipe size (DN)\u003c\/strong\u003e and ensure proper installation for accurate measurement.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1khpthp\" data-start=\"1824\" data-end=\"1862\"\u003eWhy Choose the Proline Promag W 800\u003c\/h2\u003e\n\u003cp data-start=\"1864\" data-end=\"2071\"\u003e• \u003cstrong data-start=\"1866\" data-end=\"1909\"\u003eBattery-Powered for Remote Applications\u003c\/strong\u003e\u003cbr data-start=\"1909\" data-end=\"1912\"\u003eThe device operates on \u003cstrong data-start=\"1935\" data-end=\"1958\"\u003elong-life batteries\u003c\/strong\u003e, making it perfect for locations without power supply. Therefore, it reduces installation complexity and cost.\u003c\/p\u003e\n\u003cp data-start=\"2073\" data-end=\"2281\"\u003e• \u003cstrong data-start=\"2075\" data-end=\"2123\"\u003eRemote Monitoring via Wireless Communication\u003c\/strong\u003e\u003cbr data-start=\"2123\" data-end=\"2126\"\u003eWith \u003cstrong data-start=\"2131\" data-end=\"2155\"\u003eGSM\/LTE connectivity\u003c\/strong\u003e, the flowmeter enables remote data access. As a result, operators can monitor flow and detect issues without onsite visits.\u003c\/p\u003e\n\u003cp data-start=\"2283\" data-end=\"2452\"\u003e• \u003cstrong data-start=\"2285\" data-end=\"2325\"\u003eAccurate Electromagnetic Measurement\u003c\/strong\u003e\u003cbr data-start=\"2325\" data-end=\"2328\"\u003eBased on \u003cstrong data-start=\"2337\" data-end=\"2354\"\u003eFaraday’s law\u003c\/strong\u003e, it provides precise flow measurement independent of pressure, temperature, or density changes.\u003c\/p\u003e\n\u003cp data-start=\"2454\" data-end=\"2613\"\u003e• \u003cstrong data-start=\"2456\" data-end=\"2476\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-start=\"2476\" data-end=\"2479\"\u003eThe sensor has \u003cstrong data-start=\"2494\" data-end=\"2521\"\u003eno internal obstruction\u003c\/strong\u003e, so it does not create pressure drop. This improves system efficiency and energy savings.\u003c\/p\u003e\n\u003cp data-start=\"2615\" data-end=\"2779\"\u003e• \u003cstrong data-start=\"2617\" data-end=\"2648\"\u003eDesigned for Water Networks\u003c\/strong\u003e\u003cbr data-start=\"2648\" data-end=\"2651\"\u003eIt is optimized for \u003cstrong data-start=\"2671\" data-end=\"2720\"\u003emunicipal water supply and wastewater systems\u003c\/strong\u003e, including DMA zones and leakage detection applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2839\" data-end=\"2845\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2847\" data-end=\"3017\"\u003e\u003cstrong data-start=\"2847\" data-end=\"2901\"\u003eQ: What is the main advantage of the Promag W 800?\u003c\/strong\u003e\u003cbr data-start=\"2901\" data-end=\"2904\"\u003eA: Its \u003cstrong data-start=\"2911\" data-end=\"2964\"\u003ebattery-powered design and wireless communication\u003c\/strong\u003e make it ideal for remote water network monitoring.\u003c\/p\u003e\n\u003cp data-start=\"3019\" data-end=\"3186\"\u003e\u003cstrong data-start=\"3019\" data-end=\"3068\"\u003eQ: Can it be used for wastewater measurement?\u003c\/strong\u003e\u003cbr data-start=\"3068\" data-end=\"3071\"\u003eA: Yes. It is suitable for \u003cstrong data-start=\"3098\" data-end=\"3140\"\u003eboth water and wastewater applications\u003c\/strong\u003e, including pipelines with suspended solids.\u003c\/p\u003e\n\u003cp data-start=\"3188\" data-end=\"3325\"\u003e\u003cstrong data-start=\"3188\" data-end=\"3226\"\u003eQ: Does it require external power?\u003c\/strong\u003e\u003cbr data-start=\"3226\" data-end=\"3229\"\u003eA: No. It operates on \u003cstrong data-start=\"3251\" data-end=\"3273\"\u003einternal batteries\u003c\/strong\u003e, which makes it perfect for remote installations.\u003c\/p\u003e\n\u003cp data-start=\"3327\" data-end=\"3452\"\u003e\u003cstrong data-start=\"3327\" data-end=\"3362\"\u003eQ: Does it cause pressure loss?\u003c\/strong\u003e\u003cbr data-start=\"3362\" data-end=\"3365\"\u003eA: No. The electromagnetic principle ensures \u003cstrong data-start=\"3410\" data-end=\"3449\"\u003eno obstruction and no pressure drop\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327796150333,"sku":null,"price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-w800-battery-powered-flowmeter.webp?v=1783408380"},{"product_id":"e-h-proline-promag-w-500-5w5b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag W 500 5W5B electromagnetic flowmeter","description":"\u003cp data-start=\"363\" data-end=\"610\"\u003eThe \u003cstrong data-start=\"367\" data-end=\"424\"\u003eProline Promag W 500 (5W5B) Electromagnetic Flowmeter\u003c\/strong\u003e provides high-accuracy \u003cstrong data-start=\"448\" data-end=\"506\"\u003eflow measurement for water and wastewater applications\u003c\/strong\u003e. It uses \u003cstrong data-start=\"516\" data-end=\"558\"\u003eelectromagnetic measurement technology\u003c\/strong\u003e, ensuring stable performance without pressure loss.\u003c\/p\u003e\n\u003cp data-start=\"612\" data-end=\"870\"\u003eThis model features a \u003cstrong data-start=\"634\" data-end=\"663\"\u003eremote transmitter design\u003c\/strong\u003e, which allows flexible installation in harsh environments. In addition, it supports advanced diagnostics and reliable communication, making it suitable for \u003cstrong data-start=\"820\" data-end=\"869\"\u003eindustrial plants and municipal water systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"872\" data-end=\"973\"\u003eNot Recommended For:\u003cbr data-start=\"892\" data-end=\"895\"\u003e• Non-conductive liquids (e.g., oils, gases)\u003cbr data-start=\"939\" data-end=\"942\"\u003e• Very low conductivity media\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1021\" data-end=\"1039\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1041\" data-end=\"1177\"\u003e• \u003cstrong data-start=\"1043\" data-end=\"1068\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-start=\"1075\" data-end=\"1111\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e, which requires conductive liquids such as water or wastewater.\u003c\/p\u003e\n\u003cp data-start=\"1179\" data-end=\"1316\"\u003e• \u003cstrong data-start=\"1181\" data-end=\"1202\"\u003eInstallation Type\u003c\/strong\u003e: Features a \u003cstrong data-start=\"1215\" data-end=\"1245\"\u003eremote-mounted transmitter\u003c\/strong\u003e, ideal for environments with vibration, flooding, or limited access.\u003c\/p\u003e\n\u003cp data-start=\"1318\" data-end=\"1436\"\u003e• \u003cstrong data-start=\"1320\" data-end=\"1340\"\u003eApplication Type\u003c\/strong\u003e: Designed for \u003cstrong data-start=\"1355\" data-end=\"1433\"\u003emunicipal water supply, wastewater treatment, and industrial water systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1438\" data-end=\"1555\"\u003e• \u003cstrong data-start=\"1440\" data-end=\"1462\"\u003eProcess Conditions\u003c\/strong\u003e: Verify \u003cstrong data-start=\"1471\" data-end=\"1531\"\u003etemperature, pressure, and lining material compatibility\u003c\/strong\u003e for your application.\u003c\/p\u003e\n\u003cp data-start=\"1557\" data-end=\"1683\"\u003e• \u003cstrong data-start=\"1559\" data-end=\"1587\"\u003eOutput and Communication\u003c\/strong\u003e: Supports \u003cstrong data-start=\"1598\" data-end=\"1657\"\u003e4–20 mA, pulse, HART, and digital communication options\u003c\/strong\u003e for system integration.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1khpk74\" data-start=\"1729\" data-end=\"1767\"\u003eWhy Choose the Proline Promag W 500\u003c\/h2\u003e\n\u003cp data-start=\"1769\" data-end=\"1967\"\u003e• \u003cstrong data-start=\"1771\" data-end=\"1811\"\u003eAccurate Electromagnetic Measurement\u003c\/strong\u003e\u003cbr data-start=\"1811\" data-end=\"1814\"\u003eThe device uses \u003cstrong data-start=\"1830\" data-end=\"1847\"\u003eFaraday’s law\u003c\/strong\u003e to measure flow accurately. Therefore, results remain stable regardless of pressure, temperature, or density changes.\u003c\/p\u003e\n\u003cp data-start=\"1969\" data-end=\"2164\"\u003e• \u003cstrong data-start=\"1971\" data-end=\"2019\"\u003eRemote Transmitter for Flexible Installation\u003c\/strong\u003e\u003cbr data-start=\"2019\" data-end=\"2022\"\u003eThe \u003cstrong data-start=\"2026\" data-end=\"2043\"\u003eremote design\u003c\/strong\u003e separates the sensor and transmitter. As a result, it allows installation in \u003cstrong data-start=\"2121\" data-end=\"2161\"\u003eharsh or hard-to-access environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2166\" data-end=\"2331\"\u003e• \u003cstrong data-start=\"2168\" data-end=\"2188\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-start=\"2188\" data-end=\"2191\"\u003eThe sensor has \u003cstrong data-start=\"2206\" data-end=\"2233\"\u003eno internal obstruction\u003c\/strong\u003e, so it does not create pressure drop. This improves system efficiency and reduces energy costs.\u003c\/p\u003e\n\u003cp data-start=\"2333\" data-end=\"2504\"\u003e• \u003cstrong data-start=\"2335\" data-end=\"2359\"\u003eAdvanced Diagnostics\u003c\/strong\u003e\u003cbr data-start=\"2359\" data-end=\"2362\"\u003eBuilt-in diagnostics help monitor device status and detect issues early. In addition, this improves system reliability and reduces downtime.\u003c\/p\u003e\n\u003cp data-start=\"2506\" data-end=\"2663\"\u003e• \u003cstrong data-start=\"2508\" data-end=\"2539\"\u003eDesigned for Water Industry\u003c\/strong\u003e\u003cbr data-start=\"2539\" data-end=\"2542\"\u003eIt is optimized for \u003cstrong data-start=\"2562\" data-end=\"2599\"\u003ewater and wastewater applications\u003c\/strong\u003e, including pipelines with solids and varying flow conditions.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2723\" data-end=\"2729\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2731\" data-end=\"2907\"\u003e\u003cstrong data-start=\"2731\" data-end=\"2780\"\u003eQ: What is the advantage of the Promag W 500?\u003c\/strong\u003e\u003cbr data-start=\"2780\" data-end=\"2783\"\u003eA: Its \u003cstrong data-start=\"2790\" data-end=\"2819\"\u003eremote transmitter design\u003c\/strong\u003e allows flexible installation in difficult environments, improving system reliability.\u003c\/p\u003e\n\u003cp data-start=\"2909\" data-end=\"3064\"\u003e\u003cstrong data-start=\"2909\" data-end=\"2954\"\u003eQ: Can it measure wastewater with solids?\u003c\/strong\u003e\u003cbr data-start=\"2954\" data-end=\"2957\"\u003eA: Yes. It is designed for \u003cstrong data-start=\"2984\" data-end=\"3021\"\u003ewater and wastewater applications\u003c\/strong\u003e, including fluids with suspended solids.\u003c\/p\u003e\n\u003cp data-start=\"3066\" data-end=\"3198\"\u003e\u003cstrong data-start=\"3066\" data-end=\"3104\"\u003eQ: Does it require a power supply?\u003c\/strong\u003e\u003cbr data-start=\"3104\" data-end=\"3107\"\u003eA: Yes. It operates with a \u003cstrong data-start=\"3134\" data-end=\"3168\"\u003estandard external power supply\u003c\/strong\u003e for continuous measurement.\u003c\/p\u003e\n\u003cp data-start=\"3200\" data-end=\"3325\"\u003e\u003cstrong data-start=\"3200\" data-end=\"3235\"\u003eQ: Does it cause pressure loss?\u003c\/strong\u003e\u003cbr data-start=\"3235\" data-end=\"3238\"\u003eA: No. The electromagnetic principle ensures \u003cstrong data-start=\"3283\" data-end=\"3322\"\u003eno obstruction and no pressure drop\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327854215229,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-w500-5w5b-electromagnetic-flowmeter.webp?v=1783408882"},{"product_id":"e-h-proline-promag-p-10-5pbb-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag P 10 5PBB electromagnetic flowmeter","description":"\u003cp data-start=\"361\" data-end=\"628\"\u003eThe \u003cstrong data-start=\"365\" data-end=\"421\"\u003eProline Promag P 10 (5PBB) Electromagnetic Flowmeter\u003c\/strong\u003e is designed for accurate \u003cstrong data-start=\"447\" data-end=\"524\"\u003eflow measurement of conductive liquids in chemical and process industries\u003c\/strong\u003e. It uses \u003cstrong data-start=\"534\" data-end=\"576\"\u003eelectromagnetic measurement technology\u003c\/strong\u003e, ensuring stable performance without pressure loss.\u003c\/p\u003e\n\u003cp data-start=\"630\" data-end=\"870\"\u003eThis model is ideal for \u003cstrong data-start=\"654\" data-end=\"688\"\u003ecorrosive and aggressive media\u003c\/strong\u003e, such as acids, alkalis, and chemical solutions. In addition, it offers \u003cstrong data-start=\"761\" data-end=\"811\"\u003erobust lining materials and reliable operation\u003c\/strong\u003e, making it suitable for demanding industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"872\" data-end=\"985\"\u003eNot Recommended For:\u003cbr data-start=\"892\" data-end=\"895\"\u003e• Non-conductive liquids (e.g., oils, gases)\u003cbr data-start=\"939\" data-end=\"942\"\u003e• Applications with very low conductivity\u003c\/p\u003e\n\u003ch2 data-end=\"1051\" data-start=\"1033\" data-section-id=\"92cgsm\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-end=\"1213\" data-start=\"1053\"\u003e• \u003cstrong data-end=\"1080\" data-start=\"1055\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-end=\"1123\" data-start=\"1087\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e, which requires conductive liquids. Ensure your medium meets conductivity requirements.\u003c\/p\u003e\n\u003cp data-end=\"1349\" data-start=\"1215\"\u003e• \u003cstrong data-end=\"1237\" data-start=\"1217\"\u003eApplication Type\u003c\/strong\u003e: Designed for \u003cstrong data-end=\"1287\" data-start=\"1252\"\u003echemical and process industries\u003c\/strong\u003e, especially for corrosive fluids such as acids and alkalis.\u003c\/p\u003e\n\u003cp data-end=\"1495\" data-start=\"1351\"\u003e• \u003cstrong data-end=\"1386\" data-start=\"1353\"\u003eLining and Electrode Material\u003c\/strong\u003e: Select appropriate \u003cstrong data-end=\"1445\" data-start=\"1407\"\u003elining materials (e.g., PTFE, PFA)\u003c\/strong\u003e and electrodes based on chemical compatibility.\u003c\/p\u003e\n\u003cp data-end=\"1613\" data-start=\"1497\"\u003e• \u003cstrong data-end=\"1521\" data-start=\"1499\"\u003eProcess Conditions\u003c\/strong\u003e: Verify \u003cstrong data-end=\"1580\" data-start=\"1530\"\u003etemperature, pressure, and chemical resistance\u003c\/strong\u003e to ensure long-term stability.\u003c\/p\u003e\n\u003cp data-end=\"1734\" data-start=\"1615\"\u003e• \u003cstrong data-end=\"1645\" data-start=\"1617\"\u003eOutput and Communication\u003c\/strong\u003e: Supports \u003cstrong data-end=\"1715\" data-start=\"1656\"\u003e4–20 mA, pulse, HART, and digital communication options\u003c\/strong\u003e for integration.\u003c\/p\u003e\n\u003ch2 data-end=\"1817\" data-start=\"1780\" data-section-id=\"1f7u24z\"\u003eWhy Choose the Proline Promag P 10\u003c\/h2\u003e\n\u003cp data-end=\"2025\" data-start=\"1819\"\u003e• \u003cstrong data-end=\"1864\" data-start=\"1821\"\u003eAccurate Measurement for Chemical Media\u003c\/strong\u003e\u003cbr data-end=\"1867\" data-start=\"1864\"\u003eThe device uses \u003cstrong data-end=\"1900\" data-start=\"1883\"\u003eFaraday’s law\u003c\/strong\u003e to measure flow accurately. Therefore, it provides stable results regardless of pressure, temperature, or density changes.\u003c\/p\u003e\n\u003cp data-end=\"2232\" data-start=\"2027\"\u003e• \u003cstrong data-end=\"2062\" data-start=\"2029\"\u003eExcellent Chemical Resistance\u003c\/strong\u003e\u003cbr data-end=\"2065\" data-start=\"2062\"\u003eWith \u003cstrong data-end=\"2103\" data-start=\"2070\"\u003ehigh-quality lining materials\u003c\/strong\u003e, the flowmeter resists \u003cstrong data-end=\"2161\" data-start=\"2127\"\u003ecorrosive and aggressive media\u003c\/strong\u003e. As a result, it ensures long service life in chemical environments.\u003c\/p\u003e\n\u003cp data-end=\"2406\" data-start=\"2234\"\u003e• \u003cstrong data-end=\"2256\" data-start=\"2236\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-end=\"2259\" data-start=\"2256\"\u003eThe sensor has \u003cstrong data-end=\"2301\" data-start=\"2274\"\u003eno internal obstruction\u003c\/strong\u003e, so it does not create pressure drop. This improves process efficiency and reduces energy consumption.\u003c\/p\u003e\n\u003cp data-end=\"2567\" data-start=\"2408\"\u003e• \u003cstrong data-end=\"2452\" data-start=\"2410\"\u003eReliable Operation in Harsh Conditions\u003c\/strong\u003e\u003cbr data-end=\"2455\" data-start=\"2452\"\u003eIt performs well under \u003cstrong data-end=\"2512\" data-start=\"2478\"\u003echallenging process conditions\u003c\/strong\u003e, including chemical exposure and varying flow rates.\u003c\/p\u003e\n\u003cp data-end=\"2725\" data-start=\"2569\"\u003e• \u003cstrong data-end=\"2609\" data-start=\"2571\"\u003eSimple and Cost-Effective Solution\u003c\/strong\u003e\u003cbr data-end=\"2612\" data-start=\"2609\"\u003eThe Promag P 10 offers a \u003cstrong data-end=\"2670\" data-start=\"2637\"\u003ecompact and economical design\u003c\/strong\u003e, making it ideal for standard chemical applications.\u003c\/p\u003e\n\u003ch2 data-end=\"2791\" data-start=\"2785\" data-section-id=\"1hryhf7\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-end=\"2986\" data-start=\"2793\"\u003e\u003cstrong data-end=\"2850\" data-start=\"2793\"\u003eQ: What types of liquids can the Promag P 10 measure?\u003c\/strong\u003e\u003cbr data-end=\"2853\" data-start=\"2850\"\u003eA: It measures \u003cstrong data-end=\"2890\" data-start=\"2868\"\u003econductive liquids\u003c\/strong\u003e, especially \u003cstrong data-end=\"2945\" data-start=\"2903\"\u003eacids, alkalis, and chemical solutions\u003c\/strong\u003e. It is not suitable for oils or gases.\u003c\/p\u003e\n\u003cp data-end=\"3150\" data-start=\"2988\"\u003e\u003cstrong data-end=\"3026\" data-start=\"2988\"\u003eQ: Does it handle corrosive media?\u003c\/strong\u003e\u003cbr data-end=\"3029\" data-start=\"3026\"\u003eA: Yes. It is specifically designed for \u003cstrong data-end=\"3105\" data-start=\"3069\"\u003ecorrosive and aggressive liquids\u003c\/strong\u003e, thanks to its resistant lining materials.\u003c\/p\u003e\n\u003cp data-end=\"3277\" data-start=\"3152\"\u003e\u003cstrong data-end=\"3187\" data-start=\"3152\"\u003eQ: Does it cause pressure loss?\u003c\/strong\u003e\u003cbr data-end=\"3190\" data-start=\"3187\"\u003eA: No. The electromagnetic principle ensures \u003cstrong data-end=\"3274\" data-start=\"3235\"\u003eno obstruction and no pressure drop\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"3454\" data-start=\"3279\"\u003e\u003cstrong data-end=\"3332\" data-start=\"3279\"\u003eQ: Is it suitable for industrial chemical plants?\u003c\/strong\u003e\u003cbr data-end=\"3335\" data-start=\"3332\"\u003eA: Yes. It is widely used in \u003cstrong data-end=\"3415\" data-start=\"3364\"\u003echemical processing and industrial applications\u003c\/strong\u003e requiring reliable flow measurement.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327884853309,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-p10-5pbb-electromagnetic-flowmeter.webp?v=1783411511"},{"product_id":"e-h-proline-prosonic-flow-w-400-ultrasonic-clamp-on-flowmeter","title":"Endress+Hauser Proline Prosonic Flow W 400 ultrasonic clamp-on flowmeter","description":"\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003cp data-start=\"371\" data-end=\"636\"\u003eThe \u003cstrong data-start=\"375\" data-end=\"436\"\u003eProline Prosonic Flow W 400 Ultrasonic Clamp-On Flowmeter\u003c\/strong\u003e provides accurate \u003cstrong data-start=\"455\" data-end=\"526\"\u003enon-invasive flow measurement for water and wastewater applications\u003c\/strong\u003e. It uses \u003cstrong data-start=\"536\" data-end=\"574\"\u003eultrasonic transit-time technology\u003c\/strong\u003e, allowing measurement without direct contact with the medium.\u003c\/p\u003e\n\u003cp data-start=\"638\" data-end=\"945\"\u003eBecause of its \u003cstrong data-start=\"653\" data-end=\"672\"\u003eclamp-on design\u003c\/strong\u003e, installation is quick and does not require pipe cutting or process shutdown. In addition, the device delivers reliable performance for \u003cstrong data-start=\"809\" data-end=\"867\"\u003elarge pipelines, retrofits, and temporary measurements\u003c\/strong\u003e. This makes it ideal for municipal water systems and industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"947\" data-end=\"1092\"\u003eNot Recommended For:\u003cbr data-start=\"967\" data-end=\"970\"\u003e• Liquids with very high gas content or heavy solids\u003cbr data-start=\"1022\" data-end=\"1025\"\u003e• Applications requiring inline measurement with maximum accuracy\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1140\" data-end=\"1158\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1160\" data-end=\"1294\"\u003e• \u003cstrong data-start=\"1162\" data-end=\"1187\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-start=\"1194\" data-end=\"1232\"\u003eultrasonic transit-time technology\u003c\/strong\u003e. It is suitable for clean or slightly contaminated liquids.\u003c\/p\u003e\n\u003cp data-start=\"1296\" data-end=\"1414\"\u003e• \u003cstrong data-start=\"1298\" data-end=\"1319\"\u003eInstallation Type\u003c\/strong\u003e: Features a \u003cstrong data-start=\"1332\" data-end=\"1351\"\u003eclamp-on design\u003c\/strong\u003e, mounted outside the pipe. No pipe modification is required.\u003c\/p\u003e\n\u003cp data-start=\"1416\" data-end=\"1512\"\u003e• \u003cstrong data-start=\"1418\" data-end=\"1438\"\u003eApplication Type\u003c\/strong\u003e: Ideal for \u003cstrong data-start=\"1450\" data-end=\"1509\"\u003ewater supply, wastewater, and large pipeline monitoring\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1514\" data-end=\"1637\"\u003e• \u003cstrong data-start=\"1516\" data-end=\"1535\"\u003ePipe Conditions\u003c\/strong\u003e: Ensure proper \u003cstrong data-start=\"1551\" data-end=\"1601\"\u003epipe material, diameter, and surface condition\u003c\/strong\u003e for accurate signal transmission.\u003c\/p\u003e\n\u003cp data-start=\"1639\" data-end=\"1742\"\u003e• \u003cstrong data-start=\"1641\" data-end=\"1669\"\u003eOutput and Communication\u003c\/strong\u003e: Supports \u003cstrong data-start=\"1680\" data-end=\"1739\"\u003e4–20 mA, pulse, HART, and digital communication options\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"136j4zn\" data-start=\"1788\" data-end=\"1825\"\u003eWhy Choose the Prosonic Flow W 400\u003c\/h2\u003e\n\u003cp data-start=\"1827\" data-end=\"2006\"\u003e• \u003cstrong data-start=\"1829\" data-end=\"1857\"\u003eNon-Invasive Measurement\u003c\/strong\u003e\u003cbr data-start=\"1857\" data-end=\"1860\"\u003eThe clamp-on sensors are installed \u003cstrong data-start=\"1895\" data-end=\"1915\"\u003eoutside the pipe\u003c\/strong\u003e. Therefore, there is no contact with the medium and no risk of leakage or contamination.\u003c\/p\u003e\n\u003cp data-start=\"2008\" data-end=\"2159\"\u003e• \u003cstrong data-start=\"2010\" data-end=\"2030\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-start=\"2030\" data-end=\"2033\"\u003eSince there is \u003cstrong data-start=\"2048\" data-end=\"2078\"\u003eno intrusion into the pipe\u003c\/strong\u003e, the flowmeter does not create pressure drop. This improves system efficiency.\u003c\/p\u003e\n\u003cp data-start=\"2161\" data-end=\"2333\"\u003e• \u003cstrong data-start=\"2163\" data-end=\"2197\"\u003eFast and Flexible Installation\u003c\/strong\u003e\u003cbr data-start=\"2197\" data-end=\"2200\"\u003eInstallation requires \u003cstrong data-start=\"2222\" data-end=\"2253\"\u003eno pipe cutting or shutdown\u003c\/strong\u003e. As a result, it is ideal for retrofits and temporary flow measurement tasks.\u003c\/p\u003e\n\u003cp data-start=\"2335\" data-end=\"2477\"\u003e• \u003cstrong data-start=\"2337\" data-end=\"2371\"\u003eReliable Ultrasonic Technology\u003c\/strong\u003e\u003cbr data-start=\"2371\" data-end=\"2374\"\u003eThe device uses \u003cstrong data-start=\"2390\" data-end=\"2418\"\u003etransit-time measurement\u003c\/strong\u003e, providing stable results for water and similar liquids.\u003c\/p\u003e\n\u003cp data-start=\"2479\" data-end=\"2625\"\u003e• \u003cstrong data-start=\"2481\" data-end=\"2508\"\u003ePerfect for Large Pipes\u003c\/strong\u003e\u003cbr data-start=\"2508\" data-end=\"2511\"\u003eIt performs well in \u003cstrong data-start=\"2531\" data-end=\"2559\"\u003elarge-diameter pipelines\u003c\/strong\u003e, where inline flowmeters may be difficult or costly to install.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2685\" data-end=\"2691\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2693\" data-end=\"2873\"\u003e\u003cstrong data-start=\"2693\" data-end=\"2751\"\u003eQ: What is the main advantage of a clamp-on flowmeter?\u003c\/strong\u003e\u003cbr data-start=\"2751\" data-end=\"2754\"\u003eA: It allows \u003cstrong data-start=\"2767\" data-end=\"2796\"\u003enon-invasive installation\u003c\/strong\u003e, meaning no pipe cutting, no process interruption, and no risk of leakage.\u003c\/p\u003e\n\u003cp data-start=\"2875\" data-end=\"3009\"\u003e\u003cstrong data-start=\"2875\" data-end=\"2919\"\u003eQ: What types of liquids can it measure?\u003c\/strong\u003e\u003cbr data-start=\"2919\" data-end=\"2922\"\u003eA: It is best suited for \u003cstrong data-start=\"2947\" data-end=\"2976\"\u003ewater and similar liquids\u003c\/strong\u003e with low gas or solid content.\u003c\/p\u003e\n\u003cp data-start=\"3011\" data-end=\"3129\"\u003e\u003cstrong data-start=\"3011\" data-end=\"3051\"\u003eQ: Does it affect pipeline pressure?\u003c\/strong\u003e\u003cbr data-start=\"3051\" data-end=\"3054\"\u003eA: No. Since it is installed externally, it creates \u003cstrong data-start=\"3106\" data-end=\"3126\"\u003eno pressure loss\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3131\" data-end=\"3293\"\u003e\u003cstrong data-start=\"3131\" data-end=\"3180\"\u003eQ: Is it suitable for permanent installation?\u003c\/strong\u003e\u003cbr data-start=\"3180\" data-end=\"3183\"\u003eA: Yes. It can be used for both \u003cstrong data-start=\"3215\" data-end=\"3258\"\u003etemporary and permanent flow monitoring\u003c\/strong\u003e, depending on application needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327887081533,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/prosonic-flow-w400-ultrasonic-clamp-on-flowmeter.webp?v=1783411729"},{"product_id":"e-h-proline-promag-p-500-5p5b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag P 500 5P5B electromagnetic flowmeter","description":"\u003cp data-start=\"363\" data-end=\"630\"\u003eThe \u003cstrong data-start=\"367\" data-end=\"424\"\u003eProline Promag P 500 (5P5B) Electromagnetic Flowmeter\u003c\/strong\u003e delivers high-accuracy \u003cstrong data-start=\"448\" data-end=\"526\"\u003eflow measurement for conductive liquids in chemical and process industries\u003c\/strong\u003e. It uses \u003cstrong data-start=\"536\" data-end=\"578\"\u003eelectromagnetic measurement technology\u003c\/strong\u003e, ensuring stable performance without pressure loss.\u003c\/p\u003e\n\u003cp data-start=\"632\" data-end=\"905\"\u003eThis model features a \u003cstrong data-start=\"654\" data-end=\"683\"\u003eremote transmitter design\u003c\/strong\u003e, which enables flexible installation in harsh environments. In addition, it offers \u003cstrong data-start=\"767\" data-end=\"822\"\u003eadvanced diagnostics and robust chemical resistance\u003c\/strong\u003e, making it ideal for \u003cstrong data-start=\"844\" data-end=\"878\"\u003ecorrosive and aggressive media\u003c\/strong\u003e such as acids and alkalis.\u003c\/p\u003e\n\u003cp data-start=\"907\" data-end=\"1020\"\u003eNot Recommended For:\u003cbr data-start=\"927\" data-end=\"930\"\u003e• Non-conductive liquids (e.g., oils, gases)\u003cbr data-start=\"974\" data-end=\"977\"\u003e• Applications with very low conductivity\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv data-cs-tracking-ps-name=\"PS.RichText\" class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\"\u003e\n\u003ch2 data-end=\"1086\" data-start=\"1068\" data-section-id=\"92cgsm\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-end=\"1254\" data-start=\"1088\"\u003e• \u003cstrong data-end=\"1115\" data-start=\"1090\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-end=\"1158\" data-start=\"1122\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e, which requires conductive liquids. Confirm that your medium meets conductivity requirements.\u003c\/p\u003e\n\u003cp data-end=\"1390\" data-start=\"1256\"\u003e• \u003cstrong data-end=\"1278\" data-start=\"1258\"\u003eApplication Type\u003c\/strong\u003e: Designed for \u003cstrong data-end=\"1328\" data-start=\"1293\"\u003echemical and process industries\u003c\/strong\u003e, especially for corrosive fluids such as acids and alkalis.\u003c\/p\u003e\n\u003cp data-end=\"1531\" data-start=\"1392\"\u003e• \u003cstrong data-end=\"1415\" data-start=\"1394\"\u003eInstallation Type\u003c\/strong\u003e: Features a \u003cstrong data-end=\"1458\" data-start=\"1428\"\u003eremote-mounted transmitter\u003c\/strong\u003e, suitable for harsh environments or difficult installation conditions.\u003c\/p\u003e\n\u003cp data-end=\"1659\" data-start=\"1533\"\u003e• \u003cstrong data-end=\"1557\" data-start=\"1535\"\u003eMaterial Selection\u003c\/strong\u003e: Choose appropriate \u003cstrong data-end=\"1600\" data-start=\"1578\"\u003elining (PTFE, PFA)\u003c\/strong\u003e and electrode materials based on chemical compatibility.\u003c\/p\u003e\n\u003cp data-end=\"1787\" data-start=\"1661\"\u003e• \u003cstrong data-end=\"1691\" data-start=\"1663\"\u003eOutput and Communication\u003c\/strong\u003e: Supports \u003cstrong data-end=\"1761\" data-start=\"1702\"\u003e4–20 mA, pulse, HART, and digital communication options\u003c\/strong\u003e for system integration.\u003c\/p\u003e\n\u003ch2 data-end=\"1871\" data-start=\"1833\" data-section-id=\"1kgysg7\"\u003eWhy Choose the Proline Promag P 500\u003c\/h2\u003e\n\u003cp data-end=\"2077\" data-start=\"1873\"\u003e• \u003cstrong data-end=\"1922\" data-start=\"1875\"\u003eAccurate Measurement for Chemical Processes\u003c\/strong\u003e\u003cbr data-end=\"1925\" data-start=\"1922\"\u003eThe device uses \u003cstrong data-end=\"1958\" data-start=\"1941\"\u003eFaraday’s law\u003c\/strong\u003e to measure flow precisely. Therefore, results remain stable regardless of pressure, temperature, or density changes.\u003c\/p\u003e\n\u003cp data-end=\"2271\" data-start=\"2079\"\u003e• \u003cstrong data-end=\"2126\" data-start=\"2081\"\u003eRemote Transmitter for Harsh Environments\u003c\/strong\u003e\u003cbr data-end=\"2129\" data-start=\"2126\"\u003eThe \u003cstrong data-end=\"2150\" data-start=\"2133\"\u003eremote design\u003c\/strong\u003e allows installation in \u003cstrong data-end=\"2226\" data-start=\"2174\"\u003ehigh-temperature, vibration, or restricted areas\u003c\/strong\u003e. As a result, system reliability improves.\u003c\/p\u003e\n\u003cp data-end=\"2460\" data-start=\"2273\"\u003e• \u003cstrong data-end=\"2308\" data-start=\"2275\"\u003eExcellent Chemical Resistance\u003c\/strong\u003e\u003cbr data-end=\"2311\" data-start=\"2308\"\u003eWith \u003cstrong data-end=\"2367\" data-start=\"2316\"\u003ehigh-performance lining and electrode materials\u003c\/strong\u003e, the flowmeter resists \u003cstrong data-end=\"2425\" data-start=\"2391\"\u003ecorrosive and aggressive media\u003c\/strong\u003e. This ensures long service life.\u003c\/p\u003e\n\u003cp data-end=\"2634\" data-start=\"2462\"\u003e• \u003cstrong data-end=\"2484\" data-start=\"2464\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-end=\"2487\" data-start=\"2484\"\u003eThe sensor has \u003cstrong data-end=\"2529\" data-start=\"2502\"\u003eno internal obstruction\u003c\/strong\u003e, so it does not create pressure drop. This improves process efficiency and reduces energy consumption.\u003c\/p\u003e\n\u003cp data-end=\"2813\" data-start=\"2636\"\u003e• \u003cstrong data-end=\"2678\" data-start=\"2638\"\u003eAdvanced Diagnostics and Reliability\u003c\/strong\u003e\u003cbr data-end=\"2681\" data-start=\"2678\"\u003eBuilt-in diagnostics help monitor device health and detect issues early. In addition, this reduces downtime and maintenance costs.\u003c\/p\u003e\n\u003ch2 data-end=\"2879\" data-start=\"2873\" data-section-id=\"1hryhf7\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-end=\"3050\" data-start=\"2881\"\u003e\u003cstrong data-end=\"2939\" data-start=\"2881\"\u003eQ: What applications is the Promag P 500 suitable for?\u003c\/strong\u003e\u003cbr data-end=\"2942\" data-start=\"2939\"\u003eA: It is ideal for \u003cstrong data-end=\"3047\" data-start=\"2961\"\u003echemical processing, acid and alkali measurement, and industrial flow applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"3239\" data-start=\"3052\"\u003e\u003cstrong data-end=\"3114\" data-start=\"3052\"\u003eQ: What is the advantage of the remote transmitter design?\u003c\/strong\u003e\u003cbr data-end=\"3117\" data-start=\"3114\"\u003eA: It allows flexible installation in \u003cstrong data-end=\"3195\" data-start=\"3155\"\u003eharsh or hard-to-access environments\u003c\/strong\u003e, improving system reliability and safety.\u003c\/p\u003e\n\u003cp data-end=\"3396\" data-start=\"3241\"\u003e\u003cstrong data-end=\"3281\" data-start=\"3241\"\u003eQ: Can it measure corrosive liquids?\u003c\/strong\u003e\u003cbr data-end=\"3284\" data-start=\"3281\"\u003eA: Yes. It is specifically designed for \u003cstrong data-end=\"3358\" data-start=\"3324\"\u003ecorrosive and aggressive media\u003c\/strong\u003e, thanks to its resistant materials.\u003c\/p\u003e\n\u003cp data-end=\"3523\" data-start=\"3398\"\u003e\u003cstrong data-end=\"3433\" data-start=\"3398\"\u003eQ: Does it cause pressure loss?\u003c\/strong\u003e\u003cbr data-end=\"3436\" data-start=\"3433\"\u003eA: No. The electromagnetic principle ensures \u003cstrong data-end=\"3520\" data-start=\"3481\"\u003eno obstruction and no pressure drop\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327888982077,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-p500-5p5b-electromagnetic-flowmeter.webp?v=1783412039"},{"product_id":"e-h-proline-promag-p-100-5e1b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag P 100 5E1B electromagnetic flowmeter","description":"\u003cp data-start=\"349\" data-end=\"611\"\u003eThe \u003cstrong data-start=\"353\" data-end=\"399\"\u003eEndress+Hauser Proline Promag E 100 (5E1B)\u003c\/strong\u003e is a reliable electromagnetic flowmeter designed for \u003cstrong data-start=\"453\" data-end=\"507\"\u003estandard applications involving conductive liquids\u003c\/strong\u003e. It provides stable and accurate flow measurement while maintaining a compact and lightweight design.\u003c\/p\u003e\n\u003cp data-start=\"613\" data-end=\"840\"\u003eThis device is ideal for basic process monitoring where cost efficiency and dependable performance are essential. In addition, it supports seamless integration into automation systems through digital communication interfaces.\u003c\/p\u003e\n\u003cp data-start=\"842\" data-end=\"939\"\u003eTypical applications include water treatment, utility systems and general industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"941\" data-end=\"1066\"\u003eNot Recommended For:\u003cbr data-start=\"961\" data-end=\"964\"\u003e• Non-conductive liquids such as oil or gas\u003cbr data-start=\"1007\" data-end=\"1010\"\u003e• Highly corrosive or extreme temperature environments\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1101\" data-end=\"1120\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1122\" data-end=\"1564\"\u003e• Confirm that the \u003cstrong data-start=\"1141\" data-end=\"1178\"\u003emedium is electrically conductive\u003c\/strong\u003e, which is required for electromagnetic measurement\u003cbr data-start=\"1229\" data-end=\"1232\"\u003e• Verify the \u003cstrong data-start=\"1245\" data-end=\"1259\"\u003eflow range\u003c\/strong\u003e, depending on pipe size and process conditions\u003cbr data-start=\"1306\" data-end=\"1309\"\u003e• Choose appropriate \u003cstrong data-start=\"1330\" data-end=\"1348\"\u003eliner material\u003c\/strong\u003e, typically PTFE, based on chemical compatibility\u003cbr data-start=\"1397\" data-end=\"1400\"\u003e• Check the \u003cstrong data-start=\"1412\" data-end=\"1435\"\u003eprocess temperature\u003c\/strong\u003e, usually up to around \u003cstrong data-start=\"1458\" data-end=\"1469\"\u003e+130 °C\u003c\/strong\u003e\u003cbr data-start=\"1469\" data-end=\"1472\"\u003e• In addition, ensure the \u003cstrong data-start=\"1498\" data-end=\"1531\"\u003epressure rating and pipe size\u003c\/strong\u003e match your system requirements\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tntlsm\" data-start=\"1599\" data-end=\"1630\"\u003eWhy Choose the Promag E 100\u003c\/h3\u003e\n\u003cp data-start=\"1632\" data-end=\"1805\"\u003e• \u003cstrong data-start=\"1634\" data-end=\"1670\"\u003eReliable Measurement Performance\u003c\/strong\u003e\u003cbr data-start=\"1670\" data-end=\"1673\"\u003eThe device delivers stable and repeatable readings for conductive liquids. Therefore, it is suitable for daily process monitoring.\u003c\/p\u003e\n\u003cp data-start=\"1807\" data-end=\"1968\"\u003e• \u003cstrong data-start=\"1809\" data-end=\"1844\"\u003eCompact and Space-Saving Design\u003c\/strong\u003e\u003cbr data-start=\"1844\" data-end=\"1847\"\u003eIts lightweight construction allows installation in confined spaces. As a result, it fits easily into existing systems.\u003c\/p\u003e\n\u003cp data-start=\"1970\" data-end=\"2116\"\u003e• \u003cstrong data-start=\"1972\" data-end=\"1999\"\u003eCost-Effective Solution\u003c\/strong\u003e\u003cbr data-start=\"1999\" data-end=\"2002\"\u003eThis model focuses on essential functions. Consequently, it offers a good balance between performance and price.\u003c\/p\u003e\n\u003cp data-start=\"2118\" data-end=\"2264\"\u003e• \u003cstrong data-start=\"2120\" data-end=\"2150\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"2150\" data-end=\"2153\"\u003eThere are no moving parts inside the sensor. This design reduces wear and minimizes maintenance requirements.\u003c\/p\u003e\n\u003cp data-start=\"2266\" data-end=\"2427\"\u003e• \u003cstrong data-start=\"2268\" data-end=\"2306\"\u003eFlexible Communication Integration\u003c\/strong\u003e\u003cbr data-start=\"2306\" data-end=\"2309\"\u003eIt supports outputs such as \u003cstrong data-start=\"2337\" data-end=\"2364\"\u003e4–20 mA, HART or Modbus\u003c\/strong\u003e. In addition, integration with PLC or DCS systems is simple.\u003c\/p\u003e\n\u003cp data-start=\"2429\" data-end=\"2639\"\u003e• \u003cstrong data-start=\"2431\" data-end=\"2487\"\u003eStable Measurement Independent of Process Conditions\u003c\/strong\u003e\u003cbr data-start=\"2487\" data-end=\"2490\"\u003eThe electromagnetic principle is unaffected by density, pressure or viscosity. Therefore, measurement remains consistent under changing conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"2677\" data-end=\"2684\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"2686\" data-end=\"2820\"\u003e\u003cstrong data-start=\"2686\" data-end=\"2729\"\u003eQ: What media can Promag E 100 measure?\u003c\/strong\u003e\u003cbr data-start=\"2729\" data-end=\"2732\"\u003eA: It measures \u003cstrong data-start=\"2747\" data-end=\"2769\"\u003econductive liquids\u003c\/strong\u003e, including water, wastewater and process fluids.\u003c\/p\u003e\n\u003cp data-start=\"2822\" data-end=\"2961\"\u003e\u003cstrong data-start=\"2822\" data-end=\"2861\"\u003eQ: What is the measuring principle?\u003c\/strong\u003e\u003cbr data-start=\"2861\" data-end=\"2864\"\u003eA: It uses \u003cstrong data-start=\"2875\" data-end=\"2920\"\u003eelectromagnetic induction (Faraday’s law)\u003c\/strong\u003e to determine flow velocity and volume.\u003c\/p\u003e\n\u003cp data-start=\"2963\" data-end=\"3096\"\u003e\u003cstrong data-start=\"2963\" data-end=\"2997\"\u003eQ: What outputs are available?\u003c\/strong\u003e\u003cbr data-start=\"2997\" data-end=\"3000\"\u003eA: The device supports \u003cstrong data-start=\"3023\" data-end=\"3065\"\u003e4–20 mA, HART and Modbus communication\u003c\/strong\u003e, depending on configuration.\u003c\/p\u003e\n\u003cp data-start=\"3098\" data-end=\"3220\"\u003e\u003cstrong data-start=\"3098\" data-end=\"3141\"\u003eQ: Does it require regular maintenance?\u003c\/strong\u003e\u003cbr data-start=\"3141\" data-end=\"3144\"\u003eA: No. Because it has \u003cstrong data-start=\"3166\" data-end=\"3185\"\u003eno moving parts\u003c\/strong\u003e, maintenance needs are very low.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327890063421,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-e100-5e1b-electromagnetic-flowmeter.webp?v=1783412195"},{"product_id":"e-h-proline-promag-p-100-5e1b-electromagnetic-flowmeter-1","title":"Endress+Hauser Proline Promag P 100 5E1B electromagnetic flowmeter","description":"\u003cp data-start=\"349\" data-end=\"611\"\u003eThe \u003cstrong data-start=\"353\" data-end=\"399\"\u003eEndress+Hauser Proline Promag E 100 (5E1B)\u003c\/strong\u003e is a reliable electromagnetic flowmeter designed for \u003cstrong data-start=\"453\" data-end=\"507\"\u003estandard applications involving conductive liquids\u003c\/strong\u003e. It provides stable and accurate flow measurement while maintaining a compact and lightweight design.\u003c\/p\u003e\n\u003cp data-start=\"613\" data-end=\"840\"\u003eThis device is ideal for basic process monitoring where cost efficiency and dependable performance are essential. In addition, it supports seamless integration into automation systems through digital communication interfaces.\u003c\/p\u003e\n\u003cp data-start=\"842\" data-end=\"939\"\u003eTypical applications include water treatment, utility systems and general industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"941\" data-end=\"1066\"\u003eNot Recommended For:\u003cbr data-start=\"961\" data-end=\"964\"\u003e• Non-conductive liquids such as oil or gas\u003cbr data-start=\"1007\" data-end=\"1010\"\u003e• Highly corrosive or extreme temperature environments\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1101\" data-end=\"1120\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1122\" data-end=\"1564\"\u003e• Confirm that the \u003cstrong data-start=\"1141\" data-end=\"1178\"\u003emedium is electrically conductive\u003c\/strong\u003e, which is required for electromagnetic measurement\u003cbr data-start=\"1229\" data-end=\"1232\"\u003e• Verify the \u003cstrong data-start=\"1245\" data-end=\"1259\"\u003eflow range\u003c\/strong\u003e, depending on pipe size and process conditions\u003cbr data-start=\"1306\" data-end=\"1309\"\u003e• Choose appropriate \u003cstrong data-start=\"1330\" data-end=\"1348\"\u003eliner material\u003c\/strong\u003e, typically PTFE, based on chemical compatibility\u003cbr data-start=\"1397\" data-end=\"1400\"\u003e• Check the \u003cstrong data-start=\"1412\" data-end=\"1435\"\u003eprocess temperature\u003c\/strong\u003e, usually up to around \u003cstrong data-start=\"1458\" data-end=\"1469\"\u003e+130 °C\u003c\/strong\u003e\u003cbr data-start=\"1469\" data-end=\"1472\"\u003e• In addition, ensure the \u003cstrong data-start=\"1498\" data-end=\"1531\"\u003epressure rating and pipe size\u003c\/strong\u003e match your system requirements\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tntlsm\" data-start=\"1599\" data-end=\"1630\"\u003eWhy Choose the Promag E 100\u003c\/h3\u003e\n\u003cp data-start=\"1632\" data-end=\"1805\"\u003e• \u003cstrong data-start=\"1634\" data-end=\"1670\"\u003eReliable Measurement Performance\u003c\/strong\u003e\u003cbr data-start=\"1670\" data-end=\"1673\"\u003eThe device delivers stable and repeatable readings for conductive liquids. Therefore, it is suitable for daily process monitoring.\u003c\/p\u003e\n\u003cp data-start=\"1807\" data-end=\"1968\"\u003e• \u003cstrong data-start=\"1809\" data-end=\"1844\"\u003eCompact and Space-Saving Design\u003c\/strong\u003e\u003cbr data-start=\"1844\" data-end=\"1847\"\u003eIts lightweight construction allows installation in confined spaces. As a result, it fits easily into existing systems.\u003c\/p\u003e\n\u003cp data-start=\"1970\" data-end=\"2116\"\u003e• \u003cstrong data-start=\"1972\" data-end=\"1999\"\u003eCost-Effective Solution\u003c\/strong\u003e\u003cbr data-start=\"1999\" data-end=\"2002\"\u003eThis model focuses on essential functions. Consequently, it offers a good balance between performance and price.\u003c\/p\u003e\n\u003cp data-start=\"2118\" data-end=\"2264\"\u003e• \u003cstrong data-start=\"2120\" data-end=\"2150\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"2150\" data-end=\"2153\"\u003eThere are no moving parts inside the sensor. This design reduces wear and minimizes maintenance requirements.\u003c\/p\u003e\n\u003cp data-start=\"2266\" data-end=\"2427\"\u003e• \u003cstrong data-start=\"2268\" data-end=\"2306\"\u003eFlexible Communication Integration\u003c\/strong\u003e\u003cbr data-start=\"2306\" data-end=\"2309\"\u003eIt supports outputs such as \u003cstrong data-start=\"2337\" data-end=\"2364\"\u003e4–20 mA, HART or Modbus\u003c\/strong\u003e. In addition, integration with PLC or DCS systems is simple.\u003c\/p\u003e\n\u003cp data-start=\"2429\" data-end=\"2639\"\u003e• \u003cstrong data-start=\"2431\" data-end=\"2487\"\u003eStable Measurement Independent of Process Conditions\u003c\/strong\u003e\u003cbr data-start=\"2487\" data-end=\"2490\"\u003eThe electromagnetic principle is unaffected by density, pressure or viscosity. Therefore, measurement remains consistent under changing conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"2677\" data-end=\"2684\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"2686\" data-end=\"2820\"\u003e\u003cstrong data-start=\"2686\" data-end=\"2729\"\u003eQ: What media can Promag E 100 measure?\u003c\/strong\u003e\u003cbr data-start=\"2729\" data-end=\"2732\"\u003eA: It measures \u003cstrong data-start=\"2747\" data-end=\"2769\"\u003econductive liquids\u003c\/strong\u003e, including water, wastewater and process fluids.\u003c\/p\u003e\n\u003cp data-start=\"2822\" data-end=\"2961\"\u003e\u003cstrong data-start=\"2822\" data-end=\"2861\"\u003eQ: What is the measuring principle?\u003c\/strong\u003e\u003cbr data-start=\"2861\" data-end=\"2864\"\u003eA: It uses \u003cstrong data-start=\"2875\" data-end=\"2920\"\u003eelectromagnetic induction (Faraday’s law)\u003c\/strong\u003e to determine flow velocity and volume.\u003c\/p\u003e\n\u003cp data-start=\"2963\" data-end=\"3096\"\u003e\u003cstrong data-start=\"2963\" data-end=\"2997\"\u003eQ: What outputs are available?\u003c\/strong\u003e\u003cbr data-start=\"2997\" data-end=\"3000\"\u003eA: The device supports \u003cstrong data-start=\"3023\" data-end=\"3065\"\u003e4–20 mA, HART and Modbus communication\u003c\/strong\u003e, depending on configuration.\u003c\/p\u003e\n\u003cp data-start=\"3098\" data-end=\"3220\"\u003e\u003cstrong data-start=\"3098\" data-end=\"3141\"\u003eQ: Does it require regular maintenance?\u003c\/strong\u003e\u003cbr data-start=\"3141\" data-end=\"3144\"\u003eA: No. Because it has \u003cstrong data-start=\"3166\" data-end=\"3185\"\u003eno moving parts\u003c\/strong\u003e, maintenance needs are very low.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327892586557,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-e100-5e1b-electromagnetic-flowmeter.webp?v=1783412195"},{"product_id":"e-h-proline-promag-h-10-5hbb-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag H 10 5HBB electromagnetic flowmeter","description":"\u003cp data-start=\"195\" data-end=\"514\"\u003eThe \u003cstrong data-start=\"199\" data-end=\"268\"\u003eEndress+Hauser Proline Promag H 10 5HBB Electromagnetic Flowmeter\u003c\/strong\u003e is designed for \u003cstrong data-start=\"285\" data-end=\"316\"\u003ebasic hygienic applications\u003c\/strong\u003e in the \u003cstrong data-start=\"324\" data-end=\"372\"\u003eFood \u0026amp; Beverage and Life Sciences industries\u003c\/strong\u003e. It provides \u003cstrong data-start=\"386\" data-end=\"451\"\u003eaccurate bidirectional flow measurement of conductive liquids\u003c\/strong\u003e, independent of pressure, temperature, density, and viscosity.\u003c\/p\u003e\n\u003cp data-start=\"516\" data-end=\"792\"\u003eWith its \u003cstrong data-start=\"525\" data-end=\"580\"\u003esimplified design and easy-to-use operation concept\u003c\/strong\u003e, Promag H 10 supports fast commissioning and reliable long-term operation. It is optimized for \u003cstrong data-start=\"676\" data-end=\"719\"\u003esmall line sizes and sanitary processes\u003c\/strong\u003e, making it ideal for system integrators and OEM equipment manufacturers.\u003c\/p\u003e\n\u003cp data-start=\"794\" data-end=\"907\"\u003eTypical applications include \u003cstrong data-start=\"823\" data-end=\"906\"\u003edosing, filling, batching, CIP processes, and hygienic liquid transport systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"909\" data-end=\"1062\"\u003eNot Recommended For:\u003cbr data-start=\"929\" data-end=\"932\"\u003e• Non-conductive liquids such as oils, hydrocarbons, or solvents\u003cbr data-start=\"996\" data-end=\"999\"\u003e• Media with heavy solid content or strong abrasive particles\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv data-cs-tracking-ps-name=\"PS.RichText\" class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\"\u003e\n\u003ch3 data-end=\"1116\" data-start=\"1097\" data-section-id=\"uztocl\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-end=\"1579\" data-start=\"1118\"\u003e• Confirm the \u003cstrong data-end=\"1168\" data-start=\"1132\"\u003efluid is electrically conductive\u003c\/strong\u003e, as electromagnetic measurement requires conductivity\u003cbr data-end=\"1225\" data-start=\"1222\"\u003e• Verify the \u003cstrong data-end=\"1265\" data-start=\"1238\"\u003epipe size (DN 2 to 150)\u003c\/strong\u003e and hygienic process connection type\u003cbr data-end=\"1305\" data-start=\"1302\"\u003e• Select \u003cstrong data-end=\"1336\" data-start=\"1314\"\u003ecommunication type\u003c\/strong\u003e, such as IO-Link, HART, or Modbus RS485\u003cbr data-end=\"1379\" data-start=\"1376\"\u003e• Define whether \u003cstrong data-end=\"1438\" data-start=\"1396\"\u003ebasic operation or digital integration\u003c\/strong\u003e is required (app, display, or automation system)\u003cbr data-end=\"1490\" data-start=\"1487\"\u003e• Ensure \u003cstrong data-end=\"1535\" data-start=\"1499\"\u003ehygienic compliance requirements\u003c\/strong\u003e, such as EHEDG, 3-A, and CIP\/SIP cleaning\u003c\/p\u003e\n\u003ch3 data-end=\"1649\" data-start=\"1614\" data-section-id=\"12v88ba\"\u003eWhy Choose the Promag H 10 5HBB\u003c\/h3\u003e\n\u003cp data-end=\"1845\" data-start=\"1651\"\u003e• \u003cstrong data-end=\"1691\" data-start=\"1653\"\u003eAccurate Hygienic Flow Measurement\u003c\/strong\u003e\u003cbr data-end=\"1694\" data-start=\"1691\"\u003eThe electromagnetic principle ensures stable measurement of conductive liquids. Therefore, results are independent of pressure, density, and viscosity.\u003c\/p\u003e\n\u003cp data-end=\"2024\" data-start=\"1847\"\u003e• \u003cstrong data-end=\"1888\" data-start=\"1849\"\u003eOptimized for Hygienic Applications\u003c\/strong\u003e\u003cbr data-end=\"1891\" data-start=\"1888\"\u003eDesigned for food, beverage, and life sciences. In addition, all wetted materials are \u003cstrong data-end=\"1998\" data-start=\"1977\"\u003eCIP\/SIP cleanable\u003c\/strong\u003e, ensuring safe operation.\u003c\/p\u003e\n\u003cp data-end=\"2186\" data-start=\"2026\"\u003e• \u003cstrong data-end=\"2061\" data-start=\"2028\"\u003eSimple and Fast Commissioning\u003c\/strong\u003e\u003cbr data-end=\"2064\" data-start=\"2061\"\u003eThe simplified hardware and software design reduces setup time. Consequently, installation and startup are more efficient.\u003c\/p\u003e\n\u003cp data-end=\"2320\" data-start=\"2188\"\u003e• \u003cstrong data-end=\"2221\" data-start=\"2190\"\u003eFlexible System Integration\u003c\/strong\u003e\u003cbr data-end=\"2224\" data-start=\"2221\"\u003eSupports \u003cstrong data-end=\"2268\" data-start=\"2233\"\u003eIO-Link, HART, and Modbus RS485\u003c\/strong\u003e, enabling easy integration into automation systems.\u003c\/p\u003e\n\u003cp data-end=\"2465\" data-start=\"2322\"\u003e• \u003cstrong data-end=\"2366\" data-start=\"2324\"\u003eStable Performance in Small Line Sizes\u003c\/strong\u003e\u003cbr data-end=\"2369\" data-start=\"2366\"\u003eOptimized for compact piping systems. As a result, it is widely used in OEM machinery and skids.\u003c\/p\u003e\n\u003cp data-end=\"2584\" data-start=\"2467\"\u003e• \u003cstrong data-end=\"2499\" data-start=\"2469\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-end=\"2502\" data-start=\"2499\"\u003eNo moving parts are required. Therefore, wear and maintenance costs are minimized.\u003c\/p\u003e\n\u003ch3 data-end=\"2629\" data-start=\"2622\" data-section-id=\"1xxf4ds\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-end=\"2793\" data-start=\"2631\"\u003e\u003cstrong data-end=\"2671\" data-start=\"2631\"\u003eQ: What is the Promag H 10 used for?\u003c\/strong\u003e\u003cbr data-end=\"2674\" data-start=\"2671\"\u003eA: It is used for \u003cstrong data-end=\"2743\" data-start=\"2692\"\u003ehygienic flow measurement of conductive liquids\u003c\/strong\u003e in food, beverage, and life science applications.\u003c\/p\u003e\n\u003cp data-end=\"2942\" data-start=\"2795\"\u003e\u003cstrong data-end=\"2839\" data-start=\"2795\"\u003eQ: What types of liquids can it measure?\u003c\/strong\u003e\u003cbr data-end=\"2842\" data-start=\"2839\"\u003eA: It measures \u003cstrong data-end=\"2941\" data-start=\"2857\"\u003econductive liquids such as water, dairy products, juices, and cleaning solutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"3074\" data-start=\"2944\"\u003e\u003cstrong data-end=\"2989\" data-start=\"2944\"\u003eQ: Can it measure non-conductive liquids?\u003c\/strong\u003e\u003cbr data-end=\"2992\" data-start=\"2989\"\u003eA: No. Electromagnetic flowmeters require the fluid to be electrically conductive.\u003c\/p\u003e\n\u003cp data-end=\"3207\" data-start=\"3076\"\u003e\u003cstrong data-end=\"3124\" data-start=\"3076\"\u003eQ: Is it suitable for sanitary applications?\u003c\/strong\u003e\u003cbr data-end=\"3127\" data-start=\"3124\"\u003eA: Yes. It is designed for \u003cstrong data-end=\"3206\" data-start=\"3154\"\u003ehygienic processes and supports CIP\/SIP cleaning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327901794365,"sku":null,"price":1700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-h10-5hbb-electromagnetic-flowmeter.webp?v=1783412939"},{"product_id":"e-h-proline-promag-h-500-5h5b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag H 500 5H5B electromagnetic flowmeter","description":"\u003cp data-start=\"189\" data-end=\"511\"\u003eThe \u003cstrong data-start=\"193\" data-end=\"263\"\u003eEndress+Hauser Proline Promag H 500 5H5B Electromagnetic Flowmeter\u003c\/strong\u003e is a \u003cstrong data-start=\"269\" data-end=\"316\"\u003ehigh-end hygienic flow measurement solution\u003c\/strong\u003e designed for \u003cstrong data-start=\"330\" data-end=\"378\"\u003eFood \u0026amp; Beverage and Life Sciences industries\u003c\/strong\u003e. It is optimized for demanding sanitary applications where \u003cstrong data-start=\"438\" data-end=\"497\"\u003ehigh accuracy, process safety, and advanced diagnostics\u003c\/strong\u003e are required.\u003c\/p\u003e\n\u003cp data-start=\"513\" data-end=\"786\"\u003eBased on the \u003cstrong data-start=\"526\" data-end=\"565\"\u003eelectromagnetic measuring principle\u003c\/strong\u003e, it provides \u003cstrong data-start=\"579\" data-end=\"635\"\u003ebidirectional flow measurement of conductive liquids\u003c\/strong\u003e, fully independent of pressure, density, temperature, and viscosity. This ensures stable and reliable performance even in variable process conditions.\u003c\/p\u003e\n\u003cp data-start=\"788\" data-end=\"952\"\u003eThe \u003cstrong data-start=\"792\" data-end=\"821\"\u003eremote transmitter design\u003c\/strong\u003e maximizes installation flexibility and operational safety, making it suitable for complex plant layouts and hygienic environments.\u003c\/p\u003e\n\u003cp data-start=\"954\" data-end=\"1071\"\u003eTypical applications include \u003cstrong data-start=\"983\" data-end=\"1070\"\u003edosing, filling, batching, CIP\/SIP processes, and hygienic liquid transport systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1073\" data-end=\"1215\"\u003eNot Recommended For:\u003cbr data-start=\"1093\" data-end=\"1096\"\u003e• Non-conductive liquids such as oils or hydrocarbons\u003cbr data-start=\"1149\" data-end=\"1152\"\u003e• Media with heavy solid content or strong abrasive particles\u003c\/p\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1250\" data-end=\"1269\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1271\" data-end=\"1832\"\u003e• Confirm the \u003cstrong data-start=\"1285\" data-end=\"1321\"\u003efluid is electrically conductive\u003c\/strong\u003e, required for electromagnetic measurement\u003cbr data-start=\"1363\" data-end=\"1366\"\u003e• Select appropriate \u003cstrong data-start=\"1387\" data-end=\"1421\"\u003enominal diameter (DN 2 to 150)\u003c\/strong\u003e based on pipeline size\u003cbr data-start=\"1444\" data-end=\"1447\"\u003e• Define required \u003cstrong data-start=\"1465\" data-end=\"1489\"\u003ecommunication system\u003c\/strong\u003e, such as HART, PROFIBUS, PROFINET, Modbus, Ethernet\/IP or OPC-UA\u003cbr data-start=\"1554\" data-end=\"1557\"\u003e• Choose \u003cstrong data-start=\"1566\" data-end=\"1587\"\u003eI\/O configuration\u003c\/strong\u003e, as device supports freely configurable multifunction I\/Os\u003cbr data-start=\"1646\" data-end=\"1649\"\u003e• Ensure \u003cstrong data-start=\"1658\" data-end=\"1683\"\u003ehygienic requirements\u003c\/strong\u003e, including EHEDG, 3-A, CIP\/SIP compatibility\u003cbr data-start=\"1728\" data-end=\"1731\"\u003e• Consider whether \u003cstrong data-start=\"1750\" data-end=\"1787\"\u003eHeartbeat Technology verification\u003c\/strong\u003e is required for compliance and diagnostics\u003c\/p\u003e\n\u003ch3 data-section-id=\"1r3s0lx\" data-start=\"1867\" data-end=\"1903\"\u003eWhy Choose the Promag H 500 5H5B\u003c\/h3\u003e\n\u003cp data-start=\"1905\" data-end=\"2118\"\u003e• \u003cstrong data-start=\"1907\" data-end=\"1951\"\u003eHigh-Precision Hygienic Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"1951\" data-end=\"1954\"\u003eThe electromagnetic principle provides accurate flow measurement for conductive liquids. Therefore, results are stable and independent of physical fluid properties.\u003c\/p\u003e\n\u003cp data-start=\"2120\" data-end=\"2295\"\u003e• \u003cstrong data-start=\"2122\" data-end=\"2160\"\u003eAdvanced Remote Transmitter Design\u003c\/strong\u003e\u003cbr data-start=\"2160\" data-end=\"2163\"\u003eThe separated transmitter improves installation flexibility and increases operational safety in hygienic and demanding environments.\u003c\/p\u003e\n\u003cp data-start=\"2297\" data-end=\"2488\"\u003e• \u003cstrong data-start=\"2299\" data-end=\"2339\"\u003eMultivariable Measurement Capability\u003c\/strong\u003e\u003cbr data-start=\"2339\" data-end=\"2342\"\u003eIt measures \u003cstrong data-start=\"2354\" data-end=\"2422\"\u003eflow, temperature, conductivity, mass flow, and corrected values\u003c\/strong\u003e. As a result, fewer instruments are required in the process line.\u003c\/p\u003e\n\u003cp data-start=\"2490\" data-end=\"2671\"\u003e• \u003cstrong data-start=\"2492\" data-end=\"2542\"\u003eHeartbeat Technology for Built-in Verification\u003c\/strong\u003e\u003cbr data-start=\"2542\" data-end=\"2545\"\u003eIntegrated diagnostics and verification ensure continuous compliance and process transparency without interrupting production.\u003c\/p\u003e\n\u003cp data-start=\"2673\" data-end=\"2840\"\u003e• \u003cstrong data-start=\"2675\" data-end=\"2717\"\u003eFlexible Communication and Integration\u003c\/strong\u003e\u003cbr data-start=\"2717\" data-end=\"2720\"\u003eSupports multiple industrial protocols, enabling seamless integration into modern automation systems and digital plants.\u003c\/p\u003e\n\u003cp data-start=\"2842\" data-end=\"3007\"\u003e• \u003cstrong data-start=\"2844\" data-end=\"2884\"\u003eHygienic and Maintenance-Free Design\u003c\/strong\u003e\u003cbr data-start=\"2884\" data-end=\"2887\"\u003eWith no moving parts and CIP\/SIP-compatible materials, the system ensures long-term reliability and minimal maintenance.\u003c\/p\u003e\n\u003cp data-start=\"3009\" data-end=\"3183\"\u003e• \u003cstrong data-start=\"3011\" data-end=\"3062\"\u003eOptimized for Food \u0026amp; Life Sciences Applications\u003c\/strong\u003e\u003cbr data-start=\"3062\" data-end=\"3065\"\u003eDesigned specifically for hygienic processes with strict regulatory requirements, ensuring safety and product quality.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3221\" data-end=\"3228\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3230\" data-end=\"3392\"\u003e\u003cstrong data-start=\"3230\" data-end=\"3271\"\u003eQ: What is the Promag H 500 used for?\u003c\/strong\u003e\u003cbr data-start=\"3271\" data-end=\"3274\"\u003eA: It is used for \u003cstrong data-start=\"3292\" data-end=\"3343\"\u003ehygienic flow measurement of conductive liquids\u003c\/strong\u003e in food, beverage, and life sciences industries.\u003c\/p\u003e\n\u003cp data-start=\"3394\" data-end=\"3607\"\u003e\u003cstrong data-start=\"3394\" data-end=\"3457\"\u003eQ: What makes Promag H 500 different from basic flowmeters?\u003c\/strong\u003e\u003cbr data-start=\"3457\" data-end=\"3460\"\u003eA: It offers \u003cstrong data-start=\"3473\" data-end=\"3563\"\u003eadvanced diagnostics, multivariable measurement, and Heartbeat Technology verification\u003c\/strong\u003e, making it suitable for critical processes.\u003c\/p\u003e\n\u003cp data-start=\"3609\" data-end=\"3730\"\u003e\u003cstrong data-start=\"3609\" data-end=\"3654\"\u003eQ: Can it measure non-conductive liquids?\u003c\/strong\u003e\u003cbr data-start=\"3654\" data-end=\"3657\"\u003eA: No. Electromagnetic flowmeters require electrically conductive fluids.\u003c\/p\u003e\n\u003cp data-start=\"3732\" data-end=\"3865\"\u003e\u003cstrong data-start=\"3732\" data-end=\"3780\"\u003eQ: Is it suitable for hygienic applications?\u003c\/strong\u003e\u003cbr data-start=\"3780\" data-end=\"3783\"\u003eA: Yes. It is fully compliant with \u003cstrong data-start=\"3818\" data-end=\"3864\"\u003eEHEDG, 3-A, and CIP\/SIP cleaning standards\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327903301693,"sku":null,"price":4000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-h500-5h5b-electromagnetic-flowmeter.webp?v=1783413127"},{"product_id":"e-h-proline-promag-h-300-5h3b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag H 300 5H3B electromagnetic flowmeter","description":"\u003cp data-start=\"184\" data-end=\"424\"\u003eThe \u003cstrong data-start=\"188\" data-end=\"258\"\u003eEndress+Hauser Proline Promag H 300 5H3B Electromagnetic Flowmeter\u003c\/strong\u003e is a \u003cstrong data-start=\"264\" data-end=\"303\"\u003ehigh-performance hygienic flowmeter\u003c\/strong\u003e designed for \u003cstrong data-start=\"317\" data-end=\"367\"\u003eFood \u0026amp; Beverage and Life Sciences applications\u003c\/strong\u003e requiring \u003cstrong data-start=\"378\" data-end=\"423\"\u003eaccuracy, flexibility, and process safety\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"426\" data-end=\"720\"\u003eIt uses the \u003cstrong data-start=\"438\" data-end=\"477\"\u003eelectromagnetic measuring principle\u003c\/strong\u003e to provide \u003cstrong data-start=\"489\" data-end=\"545\"\u003ebidirectional flow measurement of conductive liquids\u003c\/strong\u003e, independent of pressure, temperature, density, and viscosity. This ensures stable measurement even under changing process conditions.\u003c\/p\u003e\n\u003cp data-start=\"722\" data-end=\"954\"\u003eWith its \u003cstrong data-start=\"731\" data-end=\"816\"\u003ecompact transmitter design, flexible I\/O configuration, and advanced connectivity\u003c\/strong\u003e, Promag H 300 enables \u003cstrong data-start=\"839\" data-end=\"913\"\u003eeasy system integration and full access to process and diagnostic data\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"956\" data-end=\"1073\"\u003eTypical applications include \u003cstrong data-start=\"985\" data-end=\"1072\"\u003edosing, batching, filling, CIP\/SIP processes, and hygienic liquid transport systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1075\" data-end=\"1210\"\u003eNot Recommended For:\u003cbr data-start=\"1095\" data-end=\"1098\"\u003e• Non-conductive liquids such as oils or hydrocarbons\u003cbr data-start=\"1151\" data-end=\"1154\"\u003e• Media with heavy solids or strong abrasive particles\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1245\" data-end=\"1264\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1266\" data-end=\"1816\"\u003e• Confirm the \u003cstrong data-start=\"1280\" data-end=\"1302\"\u003efluid conductivity\u003c\/strong\u003e, as electromagnetic measurement requires conductive media\u003cbr data-start=\"1360\" data-end=\"1363\"\u003e• Select appropriate \u003cstrong data-start=\"1384\" data-end=\"1415\"\u003enominal diameter (DN 2–150)\u003c\/strong\u003e and hygienic process connection\u003cbr data-start=\"1447\" data-end=\"1450\"\u003e• Define required \u003cstrong data-start=\"1468\" data-end=\"1494\"\u003ecommunication protocol\u003c\/strong\u003e, such as HART, PROFINET, Modbus, or Ethernet-based systems\u003cbr data-start=\"1553\" data-end=\"1556\"\u003e• Choose \u003cstrong data-start=\"1565\" data-end=\"1586\"\u003eI\/O configuration\u003c\/strong\u003e, as Promag H 300 supports freely configurable inputs and outputs\u003cbr data-start=\"1651\" data-end=\"1654\"\u003e• Verify \u003cstrong data-start=\"1663\" data-end=\"1686\"\u003ehygienic compliance\u003c\/strong\u003e, including EHEDG, 3-A, and CIP\/SIP cleanability\u003cbr data-start=\"1734\" data-end=\"1737\"\u003e• Consider need for \u003cstrong data-start=\"1757\" data-end=\"1781\"\u003eHeartbeat Technology\u003c\/strong\u003e for verification and diagnostics\u003c\/p\u003e\n\u003ch3 data-section-id=\"oy5k45\" data-start=\"1851\" data-end=\"1887\"\u003eWhy Choose the Promag H 300 5H3B\u003c\/h3\u003e\n\u003cp data-start=\"1889\" data-end=\"2092\"\u003e• \u003cstrong data-start=\"1891\" data-end=\"1934\"\u003eHigh-Accuracy Hygienic Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"1934\" data-end=\"1937\"\u003eThe electromagnetic principle ensures reliable measurement of conductive liquids. Therefore, results remain stable regardless of process condition changes.\u003c\/p\u003e\n\u003cp data-start=\"2094\" data-end=\"2327\"\u003e• \u003cstrong data-start=\"2096\" data-end=\"2141\"\u003eCompact and Accessible Transmitter Design\u003c\/strong\u003e\u003cbr data-start=\"2141\" data-end=\"2144\"\u003eThe transmitter allows \u003cstrong data-start=\"2167\" data-end=\"2194\"\u003eoperation from one side\u003c\/strong\u003e, with optional remote display and WLAN access. This simplifies installation and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"2329\" data-end=\"2567\"\u003e• \u003cstrong data-start=\"2331\" data-end=\"2372\"\u003eFlexible Integration and Connectivity\u003c\/strong\u003e\u003cbr data-start=\"2372\" data-end=\"2375\"\u003eSupports multiple industrial communication protocols and \u003cstrong data-start=\"2432\" data-end=\"2460\"\u003efreely configurable I\/Os\u003c\/strong\u003e. As a result, it integrates easily into modern automation systems.\u003c\/p\u003e\n\u003cp data-start=\"2569\" data-end=\"2722\"\u003e• \u003cstrong data-start=\"2571\" data-end=\"2615\"\u003eFull Process and Diagnostic Transparency\u003c\/strong\u003e\u003cbr data-start=\"2615\" data-end=\"2618\"\u003eProvides continuous access to \u003cstrong data-start=\"2648\" data-end=\"2687\"\u003eprocess data and device diagnostics\u003c\/strong\u003e, improving operational visibility.\u003c\/p\u003e\n\u003cp data-start=\"2724\" data-end=\"2917\"\u003e• \u003cstrong data-start=\"2726\" data-end=\"2767\"\u003eHeartbeat Technology for Verification\u003c\/strong\u003e\u003cbr data-start=\"2767\" data-end=\"2770\"\u003eBuilt-in verification enables \u003cstrong data-start=\"2800\" data-end=\"2844\"\u003econtinuous compliance and process safety\u003c\/strong\u003e without interrupting production.\u003c\/p\u003e\n\u003cp data-start=\"2919\" data-end=\"3149\"\u003e• \u003cstrong data-start=\"2921\" data-end=\"2961\"\u003eHygienic and Maintenance-Free Design\u003c\/strong\u003e\u003cbr data-start=\"2961\" data-end=\"2964\"\u003eConstructed with \u003cstrong data-start=\"2981\" data-end=\"3022\"\u003ePFA liner and stainless steel housing\u003c\/strong\u003e, and fully \u003cstrong data-start=\"3034\" data-end=\"3055\"\u003eCIP\/SIP cleanable\u003c\/strong\u003e, ensuring long-term reliability with no moving parts.\u003c\/p\u003e\n\u003cp data-start=\"3151\" data-end=\"3329\"\u003e• \u003cstrong data-start=\"3153\" data-end=\"3185\"\u003eEnergy-Efficient Measurement\u003c\/strong\u003e\u003cbr data-start=\"3185\" data-end=\"3188\"\u003eNo pressure loss due to unobstructed flow path. Consequently, system energy consumption is minimized.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3367\" data-end=\"3374\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3376\" data-end=\"3568\"\u003e\u003cstrong data-start=\"3376\" data-end=\"3430\"\u003eQ: What applications is Promag H 300 suitable for?\u003c\/strong\u003e\u003cbr data-start=\"3430\" data-end=\"3433\"\u003eA: It is designed for \u003cstrong data-start=\"3455\" data-end=\"3517\"\u003ehygienic applications in food, beverage, and life sciences\u003c\/strong\u003e, including filling, dosing, and CIP\/SIP processes.\u003c\/p\u003e\n\u003cp data-start=\"3570\" data-end=\"3789\"\u003e\u003cstrong data-start=\"3570\" data-end=\"3629\"\u003eQ: What makes Promag H 300 different from basic models?\u003c\/strong\u003e\u003cbr data-start=\"3629\" data-end=\"3632\"\u003eA: It offers \u003cstrong data-start=\"3645\" data-end=\"3735\"\u003eadvanced connectivity, flexible I\/O configuration, and integrated Heartbeat Technology\u003c\/strong\u003e, providing better diagnostics and system integration.\u003c\/p\u003e\n\u003cp data-start=\"3791\" data-end=\"3912\"\u003e\u003cstrong data-start=\"3791\" data-end=\"3836\"\u003eQ: Can it measure non-conductive liquids?\u003c\/strong\u003e\u003cbr data-start=\"3836\" data-end=\"3839\"\u003eA: No. Electromagnetic flowmeters require electrically conductive fluids.\u003c\/p\u003e\n\u003cp data-start=\"3914\" data-end=\"4046\"\u003e\u003cstrong data-start=\"3914\" data-end=\"3959\"\u003eQ: Is it suitable for hygienic processes?\u003c\/strong\u003e\u003cbr data-start=\"3959\" data-end=\"3962\"\u003eA: Yes. It complies with \u003cstrong data-start=\"3987\" data-end=\"4011\"\u003eEHEDG, 3-A standards\u003c\/strong\u003e and supports \u003cstrong data-start=\"4025\" data-end=\"4045\"\u003eCIP\/SIP cleaning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327905824829,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-h300-5h3b-electromagnetic-flowmeter.webp?v=1783413354"},{"product_id":"e-h-proline-promag-h-200-5h2b-electromagnetic-flowmeter","title":"Endress+Hauser  Proline Promag H 200 5H2B electromagnetic flowmeter","description":"\u003cp data-start=\"215\" data-end=\"533\"\u003eThe \u003cstrong data-start=\"219\" data-end=\"289\"\u003eEndress+Hauser Proline Promag H 200 5H2B Electromagnetic Flowmeter\u003c\/strong\u003e is designed for \u003cstrong data-start=\"306\" data-end=\"356\"\u003ehigh-precision measurement of small flow rates\u003c\/strong\u003e in \u003cstrong data-start=\"360\" data-end=\"401\"\u003echemical and life sciences industries\u003c\/strong\u003e. It features \u003cstrong data-start=\"415\" data-end=\"450\"\u003egenuine loop-powered technology\u003c\/strong\u003e, enabling cost-effective integration without the need for additional power supply.\u003c\/p\u003e\n\u003cp data-start=\"535\" data-end=\"836\"\u003eUsing the \u003cstrong data-start=\"545\" data-end=\"584\"\u003eelectromagnetic measuring principle\u003c\/strong\u003e, it provides \u003cstrong data-start=\"598\" data-end=\"663\"\u003eaccurate bidirectional flow measurement of conductive liquids\u003c\/strong\u003e, independent of pressure, temperature, density, and viscosity. This ensures stable performance even in demanding process conditions.\u003c\/p\u003e\n\u003cp data-start=\"838\" data-end=\"998\"\u003eThe intrinsically safe design makes it suitable for \u003cstrong data-start=\"890\" data-end=\"909\"\u003ehazardous areas\u003c\/strong\u003e, while \u003cstrong data-start=\"917\" data-end=\"941\"\u003eHeartbeat Technology\u003c\/strong\u003e ensures continuous process reliability and verification.\u003c\/p\u003e\n\u003cp data-start=\"1000\" data-end=\"1124\"\u003eTypical applications include \u003cstrong data-start=\"1029\" data-end=\"1123\"\u003edosing, small-volume measurement, pharmaceutical processes, and chemical injection systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1126\" data-end=\"1258\"\u003eNot Recommended For:\u003cbr data-start=\"1146\" data-end=\"1149\"\u003e• Non-conductive liquids such as oils or hydrocarbons\u003cbr data-start=\"1202\" data-end=\"1205\"\u003e• Applications with large solids or strong abrasion\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1293\" data-end=\"1312\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1314\" data-end=\"2035\"\u003e• Confirm the \u003cstrong data-start=\"1328\" data-end=\"1364\"\u003efluid is electrically conductive\u003c\/strong\u003e, required for electromagnetic measurement\u003cbr data-start=\"1406\" data-end=\"1409\"\u003e• Verify \u003cstrong data-start=\"1418\" data-end=\"1443\"\u003esmall flow rate range\u003c\/strong\u003e, especially for dosing or micro-flow applications (down to very low flow rates) \u003cbr data-start=\"1561\" data-end=\"1564\"\u003e• Select appropriate \u003cstrong data-start=\"1585\" data-end=\"1615\"\u003enominal diameter (DN 2–25)\u003c\/strong\u003e for small pipelines \u003cbr data-start=\"1673\" data-end=\"1676\"\u003e• Choose required \u003cstrong data-start=\"1694\" data-end=\"1720\"\u003ecommunication protocol\u003c\/strong\u003e, such as HART, PROFIBUS PA, or FOUNDATION Fieldbus \u003cbr data-start=\"1809\" data-end=\"1812\"\u003e• Ensure \u003cstrong data-start=\"1821\" data-end=\"1860\"\u003ehazardous area requirements (Ex ia)\u003c\/strong\u003e if installed in explosive environments \u003cbr data-start=\"1937\" data-end=\"1940\"\u003e• Confirm \u003cstrong data-start=\"1950\" data-end=\"1988\"\u003ehygienic or chemical compatibility\u003c\/strong\u003e, including PFA liner and electrode materials\u003c\/p\u003e\n\u003ch3 data-section-id=\"1d1h8t1\" data-start=\"2070\" data-end=\"2106\"\u003eWhy Choose the Promag H 200 5H2B\u003c\/h3\u003e\n\u003cp data-start=\"2108\" data-end=\"2311\"\u003e• \u003cstrong data-start=\"2110\" data-end=\"2150\"\u003eOptimized for Small Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"2150\" data-end=\"2153\"\u003eDesigned specifically for \u003cstrong data-start=\"2179\" data-end=\"2202\"\u003every low flow rates\u003c\/strong\u003e, making it ideal for dosing and precise liquid control applications.\u003c\/p\u003e\n\u003cp data-start=\"2313\" data-end=\"2495\"\u003e• \u003cstrong data-start=\"2315\" data-end=\"2351\"\u003eLoop-Powered Technology (2-Wire)\u003c\/strong\u003e\u003cbr data-start=\"2351\" data-end=\"2354\"\u003eOperates without additional power supply. Therefore, installation is simpler and more cost-efficient.\u003c\/p\u003e\n\u003cp data-start=\"2497\" data-end=\"2682\"\u003e• \u003cstrong data-start=\"2499\" data-end=\"2539\"\u003eIntrinsic Safety for Hazardous Areas\u003c\/strong\u003e\u003cbr data-start=\"2539\" data-end=\"2542\"\u003eCertified for \u003cstrong data-start=\"2556\" data-end=\"2578\"\u003eEx ia environments\u003c\/strong\u003e, ensuring safe operation in chemical and explosive atmospheres.\u003c\/p\u003e\n\u003cp data-start=\"2684\" data-end=\"2850\"\u003e• \u003cstrong data-start=\"2686\" data-end=\"2715\"\u003eHigh Measurement Accuracy\u003c\/strong\u003e\u003cbr data-start=\"2715\" data-end=\"2718\"\u003eAchieves up to \u003cstrong data-start=\"2733\" data-end=\"2751\"\u003e±0.5% accuracy\u003c\/strong\u003e, ensuring reliable process control even at low flow rates.\u003c\/p\u003e\n\u003cp data-start=\"2852\" data-end=\"2987\"\u003e• \u003cstrong data-start=\"2854\" data-end=\"2903\"\u003eHeartbeat Technology for Process Verification\u003c\/strong\u003e\u003cbr data-start=\"2903\" data-end=\"2906\"\u003eEnables continuous diagnostics and verification without interrupting the process.\u003c\/p\u003e\n\u003cp data-start=\"2989\" data-end=\"3186\"\u003e• \u003cstrong data-start=\"2991\" data-end=\"3034\"\u003eHygienic and Corrosion-Resistant Design\u003c\/strong\u003e\u003cbr data-start=\"3034\" data-end=\"3037\"\u003eFeatures \u003cstrong data-start=\"3046\" data-end=\"3087\"\u003ePFA liner and stainless steel housing\u003c\/strong\u003e, suitable for aggressive chemicals and hygienic processes.\u003c\/p\u003e\n\u003cp data-start=\"3188\" data-end=\"3347\"\u003e• \u003cstrong data-start=\"3190\" data-end=\"3220\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"3220\" data-end=\"3223\"\u003eNo moving parts and no pressure loss. Consequently, operating costs are minimized.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"3385\" data-end=\"3392\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"3394\" data-end=\"3558\"\u003e\u003cstrong data-start=\"3394\" data-end=\"3438\"\u003eQ: What is Promag H 200 mainly used for?\u003c\/strong\u003e\u003cbr data-start=\"3438\" data-end=\"3441\"\u003eA: It is designed for \u003cstrong data-start=\"3463\" data-end=\"3494\"\u003esmall flow rate measurement\u003c\/strong\u003e, especially in chemical dosing and pharmaceutical applications.\u003c\/p\u003e\n\u003cp data-start=\"3560\" data-end=\"3778\"\u003e\u003cstrong data-start=\"3560\" data-end=\"3616\"\u003eQ: What makes it different from Promag H 300 or 500?\u003c\/strong\u003e\u003cbr data-start=\"3616\" data-end=\"3619\"\u003eA: Promag H 200 focuses on \u003cstrong data-start=\"3646\" data-end=\"3704\"\u003eloop-powered, compact, and hazardous-area applications\u003c\/strong\u003e, while higher models provide more advanced communication and diagnostics.\u003c\/p\u003e\n\u003cp data-start=\"3780\" data-end=\"3936\"\u003e\u003cstrong data-start=\"3780\" data-end=\"3821\"\u003eQ: Can it be used in hazardous areas?\u003c\/strong\u003e\u003cbr data-start=\"3821\" data-end=\"3824\"\u003eA: Yes. It supports \u003cstrong data-start=\"3844\" data-end=\"3888\"\u003eintrinsically safe (Ex ia) installations\u003c\/strong\u003e, making it suitable for explosive environments.\u003c\/p\u003e\n\u003cp data-start=\"3938\" data-end=\"4082\"\u003e\u003cstrong data-start=\"3938\" data-end=\"3973\"\u003eQ: What liquids can it measure?\u003c\/strong\u003e\u003cbr data-start=\"3973\" data-end=\"3976\"\u003eA: It measures \u003cstrong data-start=\"3991\" data-end=\"4026\"\u003eelectrically conductive liquids\u003c\/strong\u003e, including chemicals, acids, and pharmaceutical fluids.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327928270909,"sku":null,"price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-h200-5h2b-electromagnetic-flowmeter.webp?v=1783413917"},{"product_id":"e-h-proline-promag-d-10-5dbb-electromagnetic-flowmeter","title":"Endress+Hauser  Proline Promag D 10 5DBB electromagnetic flowmeter","description":"\u003cp data-start=\"185\" data-end=\"490\"\u003eThe \u003cstrong data-start=\"189\" data-end=\"234\"\u003eEndress+Hauser Proline Promag D 10 (5DBB)\u003c\/strong\u003e is a compact and cost-effective electromagnetic flowmeter designed for \u003cstrong data-start=\"306\" data-end=\"349\"\u003ebasic water and wastewater applications\u003c\/strong\u003e. It uses a wafer-type design, which reduces installation space and simplifies mounting in pipelines.\u003c\/p\u003e\n\u003cp data-start=\"492\" data-end=\"784\"\u003eThis flowmeter delivers reliable measurement for conductive liquids while maintaining low maintenance requirements. In addition, it integrates modern features such as \u003cstrong data-start=\"659\" data-end=\"683\"\u003eHeartbeat Technology\u003c\/strong\u003e and mobile operation for easy commissioning and diagnostics.\u003c\/p\u003e\n\u003cp data-start=\"786\" data-end=\"878\"\u003eTypical applications include water distribution, irrigation systems and utility processes.\u003c\/p\u003e\n\u003cp data-start=\"880\" data-end=\"1008\"\u003eNot Recommended For:\u003cbr data-start=\"900\" data-end=\"903\"\u003e• Non-conductive media such as oil or gas\u003cbr data-start=\"944\" data-end=\"947\"\u003e• High-temperature or highly corrosive process environments\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1043\" data-end=\"1062\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1064\" data-end=\"1668\"\u003e• Confirm that the \u003cstrong data-start=\"1083\" data-end=\"1120\"\u003eliquid is electrically conductive\u003c\/strong\u003e, which is required for electromagnetic measurement.\u003cbr data-start=\"1172\" data-end=\"1175\"\u003e• Verify the \u003cstrong data-start=\"1188\" data-end=\"1202\"\u003eflow range\u003c\/strong\u003e, typically from \u003cstrong data-start=\"1219\" data-end=\"1244\"\u003e9 dm³\/min to 282 m³\/h\u003c\/strong\u003e. \u003cbr data-start=\"1283\" data-end=\"1286\"\u003e• Check the \u003cstrong data-start=\"1298\" data-end=\"1321\"\u003eprocess temperature\u003c\/strong\u003e, limited to around \u003cstrong data-start=\"1341\" data-end=\"1355\"\u003e0 to 60 °C\u003c\/strong\u003e with polyamide liner. \u003cbr data-start=\"1415\" data-end=\"1418\"\u003e• Ensure the \u003cstrong data-start=\"1431\" data-end=\"1450\"\u003epressure rating\u003c\/strong\u003e (PN16 \/ Class 150) matches your pipeline system. \u003cbr data-start=\"1537\" data-end=\"1540\"\u003e• In addition, confirm the \u003cstrong data-start=\"1567\" data-end=\"1594\"\u003epipe size compatibility\u003c\/strong\u003e, typically DN25 to DN100 (1″–4″).\u003c\/p\u003e\n\u003ch3 data-section-id=\"1wpsc7b\" data-start=\"1703\" data-end=\"1733\"\u003eWhy Choose the Promag D 10\u003c\/h3\u003e\n\u003cp data-start=\"1735\" data-end=\"1933\"\u003e• \u003cstrong data-start=\"1737\" data-end=\"1772\"\u003eCost-Effective Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"1772\" data-end=\"1775\"\u003eThis model is designed for basic applications. Therefore, it provides reliable performance at a lower investment cost.\u003c\/p\u003e\n\u003cp data-start=\"1935\" data-end=\"2118\"\u003e• \u003cstrong data-start=\"1937\" data-end=\"1961\"\u003eCompact Wafer Design\u003c\/strong\u003e\u003cbr data-start=\"1961\" data-end=\"1964\"\u003eThe wafer structure reduces installation length and weight. As a result, it fits easily into tight piping systems.\u003c\/p\u003e\n\u003cp data-start=\"2120\" data-end=\"2342\"\u003e• \u003cstrong data-start=\"2122\" data-end=\"2156\"\u003eStable Measurement Performance\u003c\/strong\u003e\u003cbr data-start=\"2156\" data-end=\"2159\"\u003eThe electromagnetic principle is independent of density, pressure and viscosity. Consequently, readings remain stable under varying conditions.\u003c\/p\u003e\n\u003cp data-start=\"2344\" data-end=\"2523\"\u003e• \u003cstrong data-start=\"2346\" data-end=\"2376\"\u003eMaintenance-Free Operation\u003c\/strong\u003e\u003cbr data-start=\"2376\" data-end=\"2379\"\u003eBecause there are no moving parts, wear is minimal. This design helps reduce downtime and service costs.\u003c\/p\u003e\n\u003cp data-start=\"2525\" data-end=\"2739\"\u003e• \u003cstrong data-start=\"2527\" data-end=\"2563\"\u003eHeartbeat Technology Diagnostics\u003c\/strong\u003e\u003cbr data-start=\"2563\" data-end=\"2566\"\u003eIntegrated diagnostics continuously monitor device health. In addition, verification can be performed without process interruption.\u003c\/p\u003e\n\u003cp data-start=\"2741\" data-end=\"2945\"\u003e• \u003cstrong data-start=\"2743\" data-end=\"2777\"\u003eFlexible Communication Options\u003c\/strong\u003e\u003cbr data-start=\"2777\" data-end=\"2780\"\u003eThe device supports \u003cstrong data-start=\"2800\" data-end=\"2833\"\u003e4–20 mA\/HART and Modbus RS485\u003c\/strong\u003e. Therefore, integration with PLC or SCADA systems is straightforward.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"2983\" data-end=\"2990\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"2992\" data-end=\"3199\"\u003e\u003cstrong data-start=\"2992\" data-end=\"3056\"\u003eQ: What type of applications is Promag D 10 best suited for?\u003c\/strong\u003e\u003cbr data-start=\"3056\" data-end=\"3059\"\u003eA: It is ideal for \u003cstrong data-start=\"3078\" data-end=\"3121\"\u003ebasic water and wastewater applications\u003c\/strong\u003e, especially where space is limited.\u003c\/p\u003e\n\u003cp data-start=\"3201\" data-end=\"3357\"\u003e\u003cstrong data-start=\"3201\" data-end=\"3241\"\u003eQ: What is the measurement accuracy?\u003c\/strong\u003e\u003cbr data-start=\"3241\" data-end=\"3244\"\u003eA: The standard accuracy is approximately \u003cstrong data-start=\"3286\" data-end=\"3314\"\u003e±0.5% of reading ±1 mm\/s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3359\" data-end=\"3521\"\u003e\u003cstrong data-start=\"3359\" data-end=\"3393\"\u003eQ: What outputs are available?\u003c\/strong\u003e\u003cbr data-start=\"3393\" data-end=\"3396\"\u003eA: It supports \u003cstrong data-start=\"3411\" data-end=\"3478\"\u003e4–20 mA with HART, pulse outputs and Modbus RS485 communication\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3523\" data-end=\"3692\"\u003e\u003cstrong data-start=\"3523\" data-end=\"3558\"\u003eQ: Does it require maintenance?\u003c\/strong\u003e\u003cbr data-start=\"3558\" data-end=\"3561\"\u003eA: No. The sensor has \u003cstrong data-start=\"3583\" data-end=\"3602\"\u003eno moving parts\u003c\/strong\u003e, which significantly reduces maintenance needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43327936495677,"sku":null,"price":1100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-d10-5dbb-electromagnetic-flowmeter.webp?v=1783414102"},{"product_id":"e-h-proline-promass-f-300-coriolis-flowmeter","title":"Endress+Hauser  Proline Promass F 300 Coriolis flowmeter","description":"\u003cp data-start=\"198\" data-end=\"497\"\u003eThe \u003cstrong data-start=\"202\" data-end=\"246\"\u003eProline Promass F 300 Coriolis Flowmeter\u003c\/strong\u003e is a high-performance solution for \u003cstrong data-start=\"282\" data-end=\"335\"\u003edirect mass flow measurement of liquids and gases\u003c\/strong\u003e. It uses \u003cstrong data-start=\"345\" data-end=\"380\"\u003eCoriolis measurement technology\u003c\/strong\u003e, delivering exceptional accuracy and independence from fluid properties such as density, viscosity, and temperature.\u003c\/p\u003e\n\u003cp data-start=\"499\" data-end=\"781\"\u003eThis model features a \u003cstrong data-start=\"521\" data-end=\"587\"\u003ecompact transmitter with advanced diagnostics and connectivity\u003c\/strong\u003e, making it ideal for \u003cstrong data-start=\"609\" data-end=\"656\"\u003echemical, oil \u0026amp; gas, and process industries\u003c\/strong\u003e. In addition, it provides \u003cstrong data-start=\"683\" data-end=\"713\"\u003emulti-variable measurement\u003c\/strong\u003e, including mass flow, density, and temperature, in a single device.\u003c\/p\u003e\n\u003cp data-start=\"783\" data-end=\"924\"\u003eNot Recommended For:\u003cbr data-start=\"803\" data-end=\"806\"\u003e• Very low-flow applications with unstable conditions\u003cbr data-start=\"859\" data-end=\"862\"\u003e• Situations where cost is the primary concern over accuracy\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"972\" data-end=\"990\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"992\" data-end=\"1124\"\u003e• \u003cstrong data-start=\"994\" data-end=\"1019\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-start=\"1026\" data-end=\"1049\"\u003eCoriolis technology\u003c\/strong\u003e, which directly measures \u003cstrong data-start=\"1075\" data-end=\"1088\"\u003emass flow\u003c\/strong\u003e, independent of fluid properties.\u003c\/p\u003e\n\u003cp data-start=\"1126\" data-end=\"1266\"\u003e• \u003cstrong data-start=\"1128\" data-end=\"1148\"\u003eApplication Type\u003c\/strong\u003e: Suitable for \u003cstrong data-start=\"1163\" data-end=\"1184\"\u003eliquids and gases\u003c\/strong\u003e, especially in \u003cstrong data-start=\"1200\" data-end=\"1263\"\u003echemical, oil \u0026amp; gas, and high-precision dosing applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1268\" data-end=\"1403\"\u003e• \u003cstrong data-start=\"1270\" data-end=\"1295\"\u003eAccuracy Requirements\u003c\/strong\u003e: Ideal for applications requiring \u003cstrong data-start=\"1330\" data-end=\"1362\"\u003ehigh accuracy (up to ±0.05%)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1405\" data-end=\"1538\"\u003e• \u003cstrong data-start=\"1407\" data-end=\"1429\"\u003eProcess Conditions\u003c\/strong\u003e: Supports \u003cstrong data-start=\"1440\" data-end=\"1478\"\u003eextreme temperatures (up to 350°C)\u003c\/strong\u003e and high pressures.\u003c\/p\u003e\n\u003cp data-start=\"1540\" data-end=\"1692\"\u003e• \u003cstrong data-start=\"1542\" data-end=\"1564\"\u003eInstallation Space\u003c\/strong\u003e: Compact design with \u003cstrong data-start=\"1586\" data-end=\"1619\"\u003eno straight pipe requirements\u003c\/strong\u003e, allowing flexible installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1v5d1rk\" data-start=\"1738\" data-end=\"1777\"\u003eWhy Choose the Proline Promass F 300\u003c\/h2\u003e\n\u003cp data-start=\"1779\" data-end=\"1973\"\u003e• \u003cstrong data-start=\"1781\" data-end=\"1813\"\u003eDirect Mass Flow Measurement\u003c\/strong\u003e\u003cbr data-start=\"1813\" data-end=\"1816\"\u003eThe Coriolis principle measures \u003cstrong data-start=\"1848\" data-end=\"1870\"\u003emass flow directly\u003c\/strong\u003e, not volume. Therefore, it eliminates errors caused by changes in temperature, pressure, or density.\u003c\/p\u003e\n\u003cp data-start=\"1975\" data-end=\"2159\"\u003e• \u003cstrong data-start=\"1977\" data-end=\"2011\"\u003ePremium Accuracy and Stability\u003c\/strong\u003e\u003cbr data-start=\"2011\" data-end=\"2014\"\u003eWith accuracy up to \u003cstrong data-start=\"2034\" data-end=\"2044\"\u003e±0.05%\u003c\/strong\u003e, it ensures precise measurement even under fluctuating process conditions.\u003c\/p\u003e\n\u003cp data-start=\"2161\" data-end=\"2383\"\u003e• \u003cstrong data-start=\"2163\" data-end=\"2193\"\u003eMulti-Variable Measurement\u003c\/strong\u003e\u003cbr data-start=\"2193\" data-end=\"2196\"\u003eThe device measures \u003cstrong data-start=\"2216\" data-end=\"2268\"\u003emass flow, density, temperature, and volume flow\u003c\/strong\u003e simultaneously. As a result, it reduces the need for multiple instruments.\u003c\/p\u003e\n\u003cp data-start=\"2385\" data-end=\"2589\"\u003e• \u003cstrong data-start=\"2387\" data-end=\"2419\"\u003eNo Straight Pipe Requirement\u003c\/strong\u003e\u003cbr data-start=\"2419\" data-end=\"2422\"\u003eUnlike many flowmeters, it does not require upstream or downstream straight runs. This simplifies installation and saves space.\u003c\/p\u003e\n\u003cp data-start=\"2591\" data-end=\"2809\"\u003e• \u003cstrong data-start=\"2593\" data-end=\"2640\"\u003eAdvanced Diagnostics (Heartbeat Technology)\u003c\/strong\u003e\u003cbr data-start=\"2640\" data-end=\"2643\"\u003eIntegrated diagnostics provide \u003cstrong data-start=\"2674\" data-end=\"2723\"\u003econtinuous device verification and monitoring\u003c\/strong\u003e, improving reliability and reducing downtime.\u003c\/p\u003e\n\u003cp data-start=\"2811\" data-end=\"3027\"\u003e• \u003cstrong data-start=\"2813\" data-end=\"2851\"\u003eRobust Design for Harsh Conditions\u003c\/strong\u003e\u003cbr data-start=\"2851\" data-end=\"2854\"\u003eIt operates reliably in \u003cstrong data-start=\"2878\" data-end=\"2941\"\u003eextreme temperatures, pressures, and demanding environments\u003c\/strong\u003e, including chemical and oil \u0026amp; gas industries.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"3087\" data-end=\"3093\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"3095\" data-end=\"3263\"\u003e\u003cstrong data-start=\"3095\" data-end=\"3153\"\u003eQ: What is the main advantage of a Coriolis flowmeter?\u003c\/strong\u003e\u003cbr data-start=\"3153\" data-end=\"3156\"\u003eA: It provides \u003cstrong data-start=\"3171\" data-end=\"3227\"\u003edirect mass flow measurement with very high accuracy\u003c\/strong\u003e, independent of fluid properties.\u003c\/p\u003e\n\u003cp data-start=\"3265\" data-end=\"3436\"\u003e\u003cstrong data-start=\"3265\" data-end=\"3311\"\u003eQ: Can the Promass F 300 measure gas flow?\u003c\/strong\u003e\u003cbr data-start=\"3311\" data-end=\"3314\"\u003eA: Yes. It is suitable for \u003cstrong data-start=\"3341\" data-end=\"3367\"\u003eboth liquids and gases\u003c\/strong\u003e, making it highly versatile.\u003c\/p\u003e\n\u003cp data-start=\"3438\" data-end=\"3620\"\u003e\u003cstrong data-start=\"3438\" data-end=\"3488\"\u003eQ: Does it require straight pipe installation?\u003c\/strong\u003e\u003cbr data-start=\"3488\" data-end=\"3491\"\u003eA: No. It does \u003cstrong data-start=\"3506\" data-end=\"3551\"\u003enot require straight inlet or outlet runs\u003c\/strong\u003e, simplifying installation.\u003c\/p\u003e\n\u003cp data-start=\"3622\" data-end=\"3775\"\u003e\u003cstrong data-start=\"3622\" data-end=\"3673\"\u003eQ: What industries commonly use this flowmeter?\u003c\/strong\u003e\u003cbr data-start=\"3673\" data-end=\"3676\"\u003eA: It is widely used in \u003cstrong data-start=\"3700\" data-end=\"3772\"\u003echemical processing, oil \u0026amp; gas, food \u0026amp; beverage, and pharmaceuticals\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43328026378301,"sku":null,"price":1490.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promass-f300-coriolis-flowmeter.webp?v=1783415869"},{"product_id":"e-h-liquiline-cm42b-1-channel-transmitter","title":"Endress+Hauser  Liquiline CM42B 1-Channel Transmitter","description":"\u003cp data-start=\"295\" data-end=\"581\"\u003eThe \u003cstrong data-start=\"299\" data-end=\"340\"\u003eLiquiline CM42B 1-Channel Transmitter\u003c\/strong\u003e is a \u003cstrong data-start=\"346\" data-end=\"371\"\u003etwo-wire field device\u003c\/strong\u003e designed for reliable \u003cstrong data-start=\"394\" data-end=\"425\"\u003eliquid analysis measurement\u003c\/strong\u003e in both \u003cstrong data-start=\"434\" data-end=\"471\"\u003ehazardous and non-hazardous areas\u003c\/strong\u003e. It supports a wide range of analytical parameters, including \u003cstrong data-start=\"534\" data-end=\"580\"\u003epH\/ORP, conductivity, and dissolved oxygen\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"583\" data-end=\"845\"\u003eThis transmitter is ideal for \u003cstrong data-start=\"613\" data-end=\"672\"\u003echemical, life sciences, and food \u0026amp; beverage industries\u003c\/strong\u003e, where hygienic design and process reliability are critical. In addition, its \u003cstrong data-start=\"751\" data-end=\"783\"\u003ecompact field-mounted design\u003c\/strong\u003e allows flexible installation directly at the measuring point.\u003c\/p\u003e\n\u003cp data-start=\"847\" data-end=\"967\"\u003eNot Recommended For:\u003cbr data-start=\"867\" data-end=\"870\"\u003e• Multi-channel measurement applications\u003cbr data-start=\"910\" data-end=\"913\"\u003e• Basic systems without analytical measurement needs\u003c\/p\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1015\" data-end=\"1033\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1035\" data-end=\"1154\"\u003e• \u003cstrong data-start=\"1037\" data-end=\"1063\"\u003eMeasurement Parameters\u003c\/strong\u003e: Supports \u003cstrong data-start=\"1074\" data-end=\"1120\"\u003epH\/ORP, conductivity, and dissolved oxygen\u003c\/strong\u003e, depending on sensor selection.\u003c\/p\u003e\n\u003cp data-start=\"1156\" data-end=\"1245\"\u003e• \u003cstrong data-start=\"1158\" data-end=\"1178\"\u003eApplication Area\u003c\/strong\u003e: Suitable for \u003cstrong data-start=\"1193\" data-end=\"1242\"\u003ehazardous (Ex) and non-hazardous environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1247\" data-end=\"1360\"\u003e• \u003cstrong data-start=\"1249\" data-end=\"1270\"\u003eInstallation Type\u003c\/strong\u003e: Designed as a \u003cstrong data-start=\"1286\" data-end=\"1315\"\u003efield-mounted transmitter\u003c\/strong\u003e, installed close to the measurement point.\u003c\/p\u003e\n\u003cp data-start=\"1362\" data-end=\"1479\"\u003e• \u003cstrong data-start=\"1364\" data-end=\"1380\"\u003ePower Supply\u003c\/strong\u003e: Features \u003cstrong data-start=\"1391\" data-end=\"1425\"\u003etwo-wire (loop-powered) design\u003c\/strong\u003e, simplifying wiring and reducing installation cost.\u003c\/p\u003e\n\u003cp data-start=\"1481\" data-end=\"1603\"\u003e• \u003cstrong data-start=\"1483\" data-end=\"1508\"\u003eHygienic Requirements\u003c\/strong\u003e: Ideal for \u003cstrong data-start=\"1520\" data-end=\"1570\"\u003efood, beverage, and life sciences applications\u003c\/strong\u003e requiring sanitary compliance.\u003c\/p\u003e\n\u003ch2 data-section-id=\"198ofhn\" data-start=\"1649\" data-end=\"1682\"\u003eWhy Choose the Liquiline CM42B\u003c\/h2\u003e\n\u003cp data-start=\"1684\" data-end=\"1852\"\u003e• \u003cstrong data-start=\"1686\" data-end=\"1726\"\u003eTwo-Wire Design for Easy Integration\u003c\/strong\u003e\u003cbr data-start=\"1726\" data-end=\"1729\"\u003eThe loop-powered design reduces wiring complexity. Therefore, it is ideal for hazardous areas and retrofit installations.\u003c\/p\u003e\n\u003cp data-start=\"1854\" data-end=\"2029\"\u003e• \u003cstrong data-start=\"1856\" data-end=\"1897\"\u003eVersatile Liquid Analysis Measurement\u003c\/strong\u003e\u003cbr data-start=\"1897\" data-end=\"1900\"\u003eThe device supports multiple analytical parameters. As a result, it provides flexibility across different process applications.\u003c\/p\u003e\n\u003cp data-start=\"2031\" data-end=\"2172\"\u003e• \u003cstrong data-start=\"2033\" data-end=\"2065\"\u003eSuitable for Hazardous Areas\u003c\/strong\u003e\u003cbr data-start=\"2065\" data-end=\"2068\"\u003eIt is certified for use in \u003cstrong data-start=\"2095\" data-end=\"2131\"\u003eexplosion-hazardous environments\u003c\/strong\u003e, ensuring safe and reliable operation.\u003c\/p\u003e\n\u003cp data-start=\"2174\" data-end=\"2340\"\u003e• \u003cstrong data-start=\"2176\" data-end=\"2206\"\u003eCompact Field Installation\u003c\/strong\u003e\u003cbr data-start=\"2206\" data-end=\"2209\"\u003eThe transmitter can be installed directly at the measuring point. This improves signal stability and reduces installation effort.\u003c\/p\u003e\n\u003cp data-start=\"2342\" data-end=\"2511\"\u003e• \u003cstrong data-start=\"2344\" data-end=\"2388\"\u003eHygienic Design for Sensitive Industries\u003c\/strong\u003e\u003cbr data-start=\"2388\" data-end=\"2391\"\u003eIt meets the requirements of \u003cstrong data-start=\"2420\" data-end=\"2469\"\u003efood, beverage, and pharmaceutical industries\u003c\/strong\u003e, ensuring safe and compliant operation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2571\" data-end=\"2577\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2579\" data-end=\"2726\"\u003e\u003cstrong data-start=\"2579\" data-end=\"2624\"\u003eQ: What parameters can the CM42B measure?\u003c\/strong\u003e\u003cbr data-start=\"2624\" data-end=\"2627\"\u003eA: It supports \u003cstrong data-start=\"2642\" data-end=\"2688\"\u003epH\/ORP, conductivity, and dissolved oxygen\u003c\/strong\u003e, depending on the connected sensor.\u003c\/p\u003e\n\u003cp data-start=\"2728\" data-end=\"2859\"\u003e\u003cstrong data-start=\"2728\" data-end=\"2770\"\u003eQ: Is it suitable for hazardous areas?\u003c\/strong\u003e\u003cbr data-start=\"2770\" data-end=\"2773\"\u003eA: Yes. It is designed for \u003cstrong data-start=\"2800\" data-end=\"2856\"\u003euse in hazardous (Ex) and non-hazardous environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2861\" data-end=\"3041\"\u003e\u003cstrong data-start=\"2861\" data-end=\"2916\"\u003eQ: What is the advantage of a two-wire transmitter?\u003c\/strong\u003e\u003cbr data-start=\"2916\" data-end=\"2919\"\u003eA: A \u003cstrong data-start=\"2924\" data-end=\"2943\"\u003etwo-wire design\u003c\/strong\u003e reduces wiring complexity and is ideal for \u003cstrong data-start=\"2987\" data-end=\"3038\"\u003ehazardous areas and long-distance installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3043\" data-end=\"3200\"\u003e\u003cstrong data-start=\"3043\" data-end=\"3090\"\u003eQ: Can it be used in hygienic applications?\u003c\/strong\u003e\u003cbr data-start=\"3090\" data-end=\"3093\"\u003eA: Yes. It is suitable for \u003cstrong data-start=\"3120\" data-end=\"3168\"\u003efood, beverage, and life sciences industries\u003c\/strong\u003e requiring hygienic operation.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43328036175933,"sku":null,"price":1100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/liquiline-cm42b-1-channel-transmitter.webp?v=1783416090"},{"product_id":"e-h-w-400-proline-promag-w-400-5w4c-electromagnetic-flowmeter","title":"Endress+Hauser  W 400 Proline Promag W 400 5W4C electromagnetic flowmeter","description":"\u003cp data-start=\"327\" data-end=\"644\"\u003eThe \u003cstrong data-start=\"331\" data-end=\"388\"\u003eProline Promag W 400 (5W4C) Electromagnetic Flowmeter\u003c\/strong\u003e is designed for reliable \u003cstrong data-start=\"414\" data-end=\"471\"\u003eflow measurement in water and wastewater applications\u003c\/strong\u003e, including installations in \u003cstrong data-start=\"500\" data-end=\"540\"\u003eharsh or hard-to-access environments\u003c\/strong\u003e. It uses \u003cstrong data-start=\"550\" data-end=\"592\"\u003eelectromagnetic measurement technology\u003c\/strong\u003e, ensuring stable performance without pressure loss.\u003c\/p\u003e\n\u003cp data-start=\"646\" data-end=\"934\"\u003eThis model features a \u003cstrong data-start=\"668\" data-end=\"712\"\u003eremote transmitter with cable connection\u003c\/strong\u003e, allowing flexible installation and safe operation in flooded or vibration-prone areas. In addition, it offers \u003cstrong data-start=\"824\" data-end=\"873\"\u003eadvanced diagnostics and robust communication\u003c\/strong\u003e, making it ideal for municipal and industrial water systems.\u003c\/p\u003e\n\u003cp data-start=\"936\" data-end=\"1058\"\u003eNot Recommended For:\u003cbr data-start=\"956\" data-end=\"959\"\u003e• Non-conductive liquids (e.g., oils, gases)\u003cbr data-start=\"1003\" data-end=\"1006\"\u003e• Applications requiring battery-powered operation\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/instrugauge.com\/wp-content\/uploads\/TI01046DEN_1021.pdf\"\u003eProline Promag W 400 Technical Information (TI)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1106\" data-end=\"1124\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1126\" data-end=\"1261\"\u003e• \u003cstrong data-start=\"1128\" data-end=\"1153\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-start=\"1160\" data-end=\"1196\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e, suitable for conductive liquids such as water and wastewater.\u003c\/p\u003e\n\u003cp data-start=\"1263\" data-end=\"1388\"\u003e• \u003cstrong data-start=\"1265\" data-end=\"1286\"\u003eInstallation Type\u003c\/strong\u003e: Features a \u003cstrong data-start=\"1299\" data-end=\"1351\"\u003eremote-mounted transmitter with cable connection\u003c\/strong\u003e, ideal for difficult environments.\u003c\/p\u003e\n\u003cp data-start=\"1390\" data-end=\"1498\"\u003e• \u003cstrong data-start=\"1392\" data-end=\"1412\"\u003eApplication Type\u003c\/strong\u003e: Designed for \u003cstrong data-start=\"1427\" data-end=\"1495\"\u003ewater supply, wastewater treatment, and industrial water systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1500\" data-end=\"1620\"\u003e• \u003cstrong data-start=\"1502\" data-end=\"1524\"\u003eProcess Conditions\u003c\/strong\u003e: Verify \u003cstrong data-start=\"1533\" data-end=\"1593\"\u003etemperature, pressure, and lining material compatibility\u003c\/strong\u003e for optimal performance.\u003c\/p\u003e\n\u003cp data-start=\"1622\" data-end=\"1725\"\u003e• \u003cstrong data-start=\"1624\" data-end=\"1652\"\u003eOutput and Communication\u003c\/strong\u003e: Supports \u003cstrong data-start=\"1663\" data-end=\"1722\"\u003e4–20 mA, pulse, HART, and digital communication options\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1khpjep\" data-start=\"1771\" data-end=\"1809\"\u003eWhy Choose the Proline Promag W 400\u003c\/h2\u003e\n\u003cp data-start=\"1811\" data-end=\"1980\"\u003e• \u003cstrong data-start=\"1813\" data-end=\"1853\"\u003eAccurate Electromagnetic Measurement\u003c\/strong\u003e\u003cbr data-start=\"1853\" data-end=\"1856\"\u003eBased on \u003cstrong data-start=\"1865\" data-end=\"1882\"\u003eFaraday’s law\u003c\/strong\u003e, it provides precise flow measurement independent of pressure, temperature, or density changes.\u003c\/p\u003e\n\u003cp data-start=\"1982\" data-end=\"2173\"\u003e• \u003cstrong data-start=\"1984\" data-end=\"2028\"\u003eRemote Transmitter with Cable Connection\u003c\/strong\u003e\u003cbr data-start=\"2028\" data-end=\"2031\"\u003eThe transmitter can be installed away from the sensor. Therefore, it improves accessibility and safety in \u003cstrong data-start=\"2137\" data-end=\"2170\"\u003eharsh or flooded environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2175\" data-end=\"2320\"\u003e• \u003cstrong data-start=\"2177\" data-end=\"2197\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-start=\"2197\" data-end=\"2200\"\u003eThe full-bore design ensures \u003cstrong data-start=\"2229\" data-end=\"2247\"\u003eno obstruction\u003c\/strong\u003e, so it does not create pressure drop. This improves system efficiency.\u003c\/p\u003e\n\u003cp data-start=\"2322\" data-end=\"2482\"\u003e• \u003cstrong data-start=\"2324\" data-end=\"2363\"\u003eAdvanced Diagnostics and Monitoring\u003c\/strong\u003e\u003cbr data-start=\"2363\" data-end=\"2366\"\u003eIntegrated diagnostics help detect issues early. In addition, they improve system reliability and reduce downtime.\u003c\/p\u003e\n\u003cp data-start=\"2484\" data-end=\"2636\"\u003e• \u003cstrong data-start=\"2486\" data-end=\"2518\"\u003eOptimized for Water Industry\u003c\/strong\u003e\u003cbr data-start=\"2518\" data-end=\"2521\"\u003eIt is specifically designed for \u003cstrong data-start=\"2553\" data-end=\"2600\"\u003emunicipal water and wastewater applications\u003c\/strong\u003e, including pipelines with solids.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2696\" data-end=\"2702\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2704\" data-end=\"2865\"\u003e\u003cstrong data-start=\"2704\" data-end=\"2753\"\u003eQ: What is the advantage of the Promag W 400?\u003c\/strong\u003e\u003cbr data-start=\"2753\" data-end=\"2756\"\u003eA: Its \u003cstrong data-start=\"2763\" data-end=\"2807\"\u003eremote transmitter with cable connection\u003c\/strong\u003e allows flexible installation in difficult environments.\u003c\/p\u003e\n\u003cp data-start=\"2867\" data-end=\"3016\"\u003e\u003cstrong data-start=\"2867\" data-end=\"2906\"\u003eQ: Can it be used in flooded areas?\u003c\/strong\u003e\u003cbr data-start=\"2906\" data-end=\"2909\"\u003eA: Yes. The remote design allows the transmitter to be installed in a safe location away from the sensor.\u003c\/p\u003e\n\u003cp data-start=\"3018\" data-end=\"3141\"\u003e\u003cstrong data-start=\"3018\" data-end=\"3056\"\u003eQ: Does it require external power?\u003c\/strong\u003e\u003cbr data-start=\"3056\" data-end=\"3059\"\u003eA: Yes. It operates with a \u003cstrong data-start=\"3086\" data-end=\"3111\"\u003estandard power supply\u003c\/strong\u003e for continuous measurement.\u003c\/p\u003e\n\u003cp data-start=\"3143\" data-end=\"3268\"\u003e\u003cstrong data-start=\"3143\" data-end=\"3178\"\u003eQ: Does it cause pressure loss?\u003c\/strong\u003e\u003cbr data-start=\"3178\" data-end=\"3181\"\u003eA: No. The electromagnetic principle ensures \u003cstrong data-start=\"3226\" data-end=\"3265\"\u003eno obstruction and no pressure drop\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338545758269,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/promag-w400-5w4c-electromagnetic-flowmeter..png?v=1783926827"},{"product_id":"e-h-proline-promag-w-300-5w3b-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag W 300 5W3B electromagnetic flowmeter","description":"\u003cp data-start=\"327\" data-end=\"574\"\u003eThe \u003cstrong data-start=\"331\" data-end=\"388\"\u003eProline Promag W 300 (5W3B) Electromagnetic Flowmeter\u003c\/strong\u003e provides high-accuracy \u003cstrong data-start=\"412\" data-end=\"470\"\u003eflow measurement for water and wastewater applications\u003c\/strong\u003e. It uses \u003cstrong data-start=\"480\" data-end=\"522\"\u003eelectromagnetic measurement technology\u003c\/strong\u003e, ensuring stable performance without pressure loss.\u003c\/p\u003e\n\u003cp data-start=\"576\" data-end=\"865\"\u003eThis model features a \u003cstrong data-start=\"598\" data-end=\"659\"\u003ecompact transmitter with integrated display and operation\u003c\/strong\u003e, making it ideal for applications requiring \u003cstrong data-start=\"704\" data-end=\"747\"\u003elocal monitoring and easy configuration\u003c\/strong\u003e. In addition, it offers \u003cstrong data-start=\"772\" data-end=\"823\"\u003eadvanced diagnostics and reliable communication\u003c\/strong\u003e, ensuring efficient and stable operation.\u003c\/p\u003e\n\u003cp data-start=\"867\" data-end=\"1003\"\u003eNot Recommended For:\u003cbr data-start=\"887\" data-end=\"890\"\u003e• Non-conductive liquids (e.g., oils, gases)\u003cbr data-start=\"934\" data-end=\"937\"\u003e• Applications requiring battery-powered or fully remote systems\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/instrugauge.com\/wp-content\/uploads\/TI01414DEN_0525-00.pdf\"\u003eTI Proline Promag W 300\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"eh-cell eh-cell--6-col-large eh-cell--6-col-medium eh-cell eh-cell--12-col-small eh-cell eh-cell--4-col-x-small\"\u003e\n\u003cdiv class=\"eh-upid-field-of-application eh-p-r--large eh-p-r--medium\" data-cs-tracking-ps-name=\"PS.RichText\"\u003e\n\u003ch2 data-section-id=\"92cgsm\" data-start=\"1051\" data-end=\"1069\"\u003eSelection Notes\u003c\/h2\u003e\n\u003cp data-start=\"1071\" data-end=\"1206\"\u003e• \u003cstrong data-start=\"1073\" data-end=\"1098\"\u003eMeasurement Principle\u003c\/strong\u003e: Uses \u003cstrong data-start=\"1105\" data-end=\"1141\"\u003eelectromagnetic flow measurement\u003c\/strong\u003e, suitable for conductive liquids such as water and wastewater.\u003c\/p\u003e\n\u003cp data-start=\"1208\" data-end=\"1316\"\u003e• \u003cstrong data-start=\"1210\" data-end=\"1231\"\u003eInstallation Type\u003c\/strong\u003e: Features a \u003cstrong data-start=\"1244\" data-end=\"1273\"\u003ecompact integrated design\u003c\/strong\u003e with transmitter and sensor in one unit.\u003c\/p\u003e\n\u003cp data-start=\"1318\" data-end=\"1433\"\u003e• \u003cstrong data-start=\"1320\" data-end=\"1340\"\u003eApplication Type\u003c\/strong\u003e: Ideal for \u003cstrong data-start=\"1352\" data-end=\"1430\"\u003emunicipal water supply, wastewater treatment, and industrial water systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1435\" data-end=\"1541\"\u003e• \u003cstrong data-start=\"1437\" data-end=\"1460\"\u003eOperation Interface\u003c\/strong\u003e: Includes \u003cstrong data-start=\"1471\" data-end=\"1506\"\u003elocal display and configuration\u003c\/strong\u003e, enabling easy onsite operation.\u003c\/p\u003e\n\u003cp data-start=\"1543\" data-end=\"1646\"\u003e• \u003cstrong data-start=\"1545\" data-end=\"1573\"\u003eOutput and Communication\u003c\/strong\u003e: Supports \u003cstrong data-start=\"1584\" data-end=\"1643\"\u003e4–20 mA, pulse, HART, and digital communication options\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1khpp8m\" data-start=\"1692\" data-end=\"1730\"\u003eWhy Choose the Proline Promag W 300\u003c\/h2\u003e\n\u003cp data-start=\"1732\" data-end=\"1901\"\u003e• \u003cstrong data-start=\"1734\" data-end=\"1774\"\u003eAccurate Electromagnetic Measurement\u003c\/strong\u003e\u003cbr data-start=\"1774\" data-end=\"1777\"\u003eBased on \u003cstrong data-start=\"1786\" data-end=\"1803\"\u003eFaraday’s law\u003c\/strong\u003e, it provides precise flow measurement independent of pressure, temperature, or density changes.\u003c\/p\u003e\n\u003cp data-start=\"1903\" data-end=\"2049\"\u003e• \u003cstrong data-start=\"1905\" data-end=\"1934\"\u003eCompact All-in-One Design\u003c\/strong\u003e\u003cbr data-start=\"1934\" data-end=\"1937\"\u003eThe \u003cstrong data-start=\"1941\" data-end=\"1978\"\u003eintegrated transmitter and sensor\u003c\/strong\u003e simplify installation. Therefore, it reduces wiring and saves space.\u003c\/p\u003e\n\u003cp data-start=\"2051\" data-end=\"2223\"\u003e• \u003cstrong data-start=\"2053\" data-end=\"2089\"\u003eLocal Display and Easy Operation\u003c\/strong\u003e\u003cbr data-start=\"2089\" data-end=\"2092\"\u003eBuilt-in display allows \u003cstrong data-start=\"2116\" data-end=\"2158\"\u003ereal-time monitoring and configuration\u003c\/strong\u003e. As a result, operators can manage the device directly onsite.\u003c\/p\u003e\n\u003cp data-start=\"2225\" data-end=\"2365\"\u003e• \u003cstrong data-start=\"2227\" data-end=\"2247\"\u003eNo Pressure Loss\u003c\/strong\u003e\u003cbr data-start=\"2247\" data-end=\"2250\"\u003eThe sensor has \u003cstrong data-start=\"2265\" data-end=\"2292\"\u003eno internal obstruction\u003c\/strong\u003e, so it does not create pressure drop. This improves system efficiency.\u003c\/p\u003e\n\u003cp data-start=\"2367\" data-end=\"2512\"\u003e• \u003cstrong data-start=\"2369\" data-end=\"2393\"\u003eAdvanced Diagnostics\u003c\/strong\u003e\u003cbr data-start=\"2393\" data-end=\"2396\"\u003eIntegrated diagnostics help detect issues early. In addition, they improve system reliability and reduce downtime.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hryhf7\" data-start=\"2572\" data-end=\"2578\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2580\" data-end=\"2725\"\u003e\u003cstrong data-start=\"2580\" data-end=\"2629\"\u003eQ: What is the advantage of the Promag W 300?\u003c\/strong\u003e\u003cbr data-start=\"2629\" data-end=\"2632\"\u003eA: Its \u003cstrong data-start=\"2639\" data-end=\"2676\"\u003ecompact design with local display\u003c\/strong\u003e allows easy installation and onsite operation.\u003c\/p\u003e\n\u003cp data-start=\"2727\" data-end=\"2882\"\u003e\u003cstrong data-start=\"2727\" data-end=\"2772\"\u003eQ: Can it measure wastewater with solids?\u003c\/strong\u003e\u003cbr data-start=\"2772\" data-end=\"2775\"\u003eA: Yes. It is suitable for \u003cstrong data-start=\"2802\" data-end=\"2839\"\u003ewater and wastewater applications\u003c\/strong\u003e, including fluids with suspended solids.\u003c\/p\u003e\n\u003cp data-start=\"2884\" data-end=\"2996\"\u003e\u003cstrong data-start=\"2884\" data-end=\"2922\"\u003eQ: Does it require external power?\u003c\/strong\u003e\u003cbr data-start=\"2922\" data-end=\"2925\"\u003eA: Yes. It uses a \u003cstrong data-start=\"2943\" data-end=\"2968\"\u003estandard power supply\u003c\/strong\u003e for continuous operation.\u003c\/p\u003e\n\u003cp data-start=\"2998\" data-end=\"3123\"\u003e\u003cstrong data-start=\"2998\" data-end=\"3033\"\u003eQ: Does it cause pressure loss?\u003c\/strong\u003e\u003cbr data-start=\"3033\" data-end=\"3036\"\u003eA: No. The electromagnetic principle ensures \u003cstrong data-start=\"3081\" data-end=\"3120\"\u003eno obstruction and no pressure drop\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338559422525,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-promag-w300-5w3b-electromagnetic-flowmeter.png?v=1783927518"},{"product_id":"endress-hauser-memosens-cfs51-pah-sensor","title":"Endress+Hauser Memosens CFS51 PAH Sensor","description":"\u003cp\u003eThe rugged and low-maintenance Memosens CFS51 fluorescence sensor measures polycyclic aromatic hydrocarbons (PAHs) in accordance with MEPC.259(68) and MEPC.340(77). Thanks to the practical solid-state reference, you can readjust and calibrate the sensor onboard the vessel - supported by user-friendly guidance in the transmitter menu. This makes the calibration procedure simple and error-free, and you benefit from an exceptionally long factory maintenance interval of 4 years.\u003c\/p\u003e\n\u003ch2\u003ePAH sensor Memosens CFS51\u003c\/h2\u003e\n\u003cp\u003eMemosens sensor for measuring the concentration of polycyclic aromatic hydrocarbons in discharge water of marine exhaust gas cleaning systems (EGCS)\u003c\/p\u003e\n\u003cp\u003eThe Memosens CFS51 fluorescence sensor accurately measures the PAH concentration in the inlet and outlet of marine gas scrubbers (ECGS) offering all benefits of the Memosens digital sensor technology.\u003c\/p\u003e\n\u003cp\u003eThe solid-state reference allows the ship's crew to calibrate and adjust the sensor directly on board, which helps extend the sensor's factory service interval to 4 years.\u003c\/p\u003e\n\u003cp\u003eThe sophisticated design of the assembly, as well as the angled installation position in which the assembly holds the sensor, prevents air bubbles from influencing the measured value.\u003c\/p\u003e\n\u003cp\u003eFor Exhaust Gas Cleaning Systems (ECGS), there is an all-in-one solution that incorporates the Memosens CFS51 PAH sensor, a pH sensor and a turbidity sensor.\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMeasuring range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e0.000 to 5000 PAHphe\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eProcess temperature\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e-5 to 55 °C (20 to 130 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eProcess pressure\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e10 bar abs. (just the sensor)\u003cbr\u003e6 bar abs. (combination sensor and assembly)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe rugged and low-maintenance Memosens CFS51 fluorescence sensor measures polycyclic aromatic hydrocarbons (PAHs) in accordance with MEPC.259(68) and MEPC.340(77). Thanks to the practical solid-state reference, you can readjust and calibrate the sensor onboard the vessel - supported by user-friendly guidance in the transmitter menu. This makes the calibration procedure simple and error-free, and you benefit from an exceptionally long factory maintenance interval of 4 years.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMemosens CFS51 measures PAHs with high accuracy in both the inlet and outlet of marine exhaust gas cleaning systems (scrubbers) and is suitable for all discharge water flow rates.\u003c\/p\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe sensor is certified by the following approval bodies:\u003c\/p\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDNV (Det Norske Veritas)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eLR (Lloyd’s Register)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eBV (Bureau Veritas)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eABS (American Bureau of Shipping)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"eh-generic--text\"\u003eFor washwater monitoring in EGCS, the PAH sensor is also available as an \u003ca class=\"eh-link eh-link--03\" title=\"Wash water monitoring for ship exhaust gas scrubbers\" href=\"https:\/\/www.endress.com\/en\/industry-expertise\/process-solutions\/wash-water-monitoring-marine\" data-cs-tracking-ps-name=\"PS.RichText\" data-cs-tracking-target-id=\"10514293\"\u003eapproved all-in-one solution\u003c\/a\u003e including pH and turbidity measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe uniquely long factory maintenance interval saves you a lot of costs and organizational effort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe optionally available flow assembly holds the sensor at the ideal installation angle to minimize disturbing influences caused by air bubbles. In addition, it can be tilted for quick mounting and dismounting of the sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDNV approved integrated turbidity correction in the range of 0-50 FNU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHigh material compliance of sensor and flow assembly according to IACS E10 (flame retardancy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe solid-state reference makes calibration very easy for the end user - and you can completely eliminate the need for toxic phenantrene, which increases safety for your employees and the environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe suitability of the solid-state reference for calibration and readjustment of the PAH sensor on board was confirmed by DNV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338568073277,"sku":null,"price":1000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-memosens-cfs51-pah-sensor.webp?v=1783928347"},{"product_id":"endress-hauser-itherm-flameline-taf12s-thermometer","title":"Endress+Hauser iTHERM FlameLine TAF12S Thermometer","description":"\u003cp data-start=\"188\" data-end=\"346\"\u003eThe \u003cstrong data-start=\"192\" data-end=\"234\"\u003eEndress+Hauser iTHERM FlameLine TAF12S\u003c\/strong\u003e is a heavy-duty \u003cstrong data-start=\"251\" data-end=\"283\"\u003ehigh-temperature thermometer\u003c\/strong\u003e designed for \u003cstrong data-start=\"297\" data-end=\"345\"\u003efurnaces, reactors, and combustion processes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"348\" data-end=\"574\"\u003eIt is built for \u003cstrong data-start=\"364\" data-end=\"391\"\u003eextreme heat conditions\u003c\/strong\u003e, where standard temperature sensors fail. Thanks to its \u003cstrong data-start=\"448\" data-end=\"507\"\u003erobust thermowell design and high-temperature materials\u003c\/strong\u003e, it ensures stable and safe measurement in demanding environments.\u003c\/p\u003e\n\u003cp data-start=\"576\" data-end=\"593\"\u003e👉 Typical use:\u003c\/p\u003e\n\u003cul data-start=\"594\" data-end=\"656\"\u003e\n\u003cli data-section-id=\"17fqdzn\" data-start=\"594\" data-end=\"606\"\u003eFurnaces\u003c\/li\u003e\n\u003cli data-section-id=\"1wjz2j8\" data-start=\"607\" data-end=\"618\"\u003eHeaters\u003c\/li\u003e\n\u003cli data-section-id=\"z6o8br\" data-start=\"619\" data-end=\"631\"\u003eReactors\u003c\/li\u003e\n\u003cli data-section-id=\"1vsxstz\" data-start=\"632\" data-end=\"656\"\u003eIncineration systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"658\" data-end=\"680\"\u003e👉 Not suitable for:\u003c\/p\u003e\n\u003cul data-start=\"681\" data-end=\"731\"\u003e\n\u003cli data-section-id=\"1h0qc27\" data-start=\"681\" data-end=\"731\"\u003eLow-temperature or general-purpose measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/bdih-download.endress.com\/file\/27de9692e42dffca83d7947e32ca98af\/TI00251TEN_1625-00.pdf\"\u003eTechnical Information\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"15tuvza\" data-start=\"738\" data-end=\"779\"\u003eWhen Should You Use TAF12S?\u003c\/h2\u003e\n\u003cp data-start=\"781\" data-end=\"828\"\u003eChoose this model if your application involves:\u003c\/p\u003e\n\u003cp data-start=\"830\" data-end=\"1034\"\u003e• \u003cstrong data-start=\"832\" data-end=\"873\"\u003eVery high temperatures (e.g. \u0026gt; 800°C)\u003c\/strong\u003e\u003cbr data-start=\"873\" data-end=\"876\"\u003e• Aggressive or high-velocity process environments\u003cbr data-start=\"926\" data-end=\"929\"\u003e• Risk of \u003cstrong data-start=\"939\" data-end=\"967\"\u003esensor damage or failure\u003c\/strong\u003e\u003cbr data-start=\"967\" data-end=\"970\"\u003e• Critical processes where temperature accuracy affects safety\u003c\/p\u003e\n\u003cp data-start=\"1036\" data-end=\"1118\"\u003eIf your process is standard or low temperature, this model is \u003cstrong data-start=\"1098\" data-end=\"1117\"\u003eover-engineered\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1fbfvnf\" data-start=\"1125\" data-end=\"1161\"\u003e What Makes It Different?\u003c\/h2\u003e\n\u003ch3 data-section-id=\"qdr8k8\" data-start=\"1163\" data-end=\"1205\"\u003e1. Designed for Extreme Temperatures\u003c\/h3\u003e\n\u003cp data-start=\"1206\" data-end=\"1351\"\u003eThis thermometer is engineered to withstand \u003cstrong data-start=\"1250\" data-end=\"1284\"\u003every high process temperatures\u003c\/strong\u003e.\u003cbr data-start=\"1285\" data-end=\"1288\"\u003e👉 It maintains accuracy where standard probes degrade quickly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2mcjm8\" data-start=\"1358\" data-end=\"1399\"\u003e2. Heavy-Duty Thermowell Protection\u003c\/h3\u003e\n\u003cp data-start=\"1400\" data-end=\"1468\"\u003eThe sensor is protected by a \u003cstrong data-start=\"1429\" data-end=\"1450\"\u003erobust thermowell\u003c\/strong\u003e, which resists:\u003c\/p\u003e\n\u003cul data-start=\"1469\" data-end=\"1528\"\u003e\n\u003cli data-section-id=\"1qs83ub\" data-start=\"1469\" data-end=\"1490\"\u003eMechanical stress\u003c\/li\u003e\n\u003cli data-section-id=\"5zh974\" data-start=\"1491\" data-end=\"1504\"\u003eCorrosion\u003c\/li\u003e\n\u003cli data-section-id=\"1r4vsgj\" data-start=\"1505\" data-end=\"1528\"\u003eProcess flow impact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1530\" data-end=\"1573\"\u003e👉 This significantly extends service life.\u003c\/p\u003e\n\u003ch3 data-section-id=\"gpjb2i\" data-start=\"1580\" data-end=\"1633\"\u003e3. Reliable Measurement in Combustion Processes\u003c\/h3\u003e\n\u003cp data-start=\"1634\" data-end=\"1787\"\u003eIt performs well in \u003cstrong data-start=\"1654\" data-end=\"1694\"\u003efurnaces and combustion environments\u003c\/strong\u003e, where conditions are unstable and harsh.\u003cbr data-start=\"1736\" data-end=\"1739\"\u003e👉 Helps maintain process safety and efficiency.\u003c\/p\u003e\n\u003chr data-start=\"1789\" data-end=\"1792\"\u003e\n\u003ch3 data-section-id=\"1ujpql6\" data-start=\"1794\" data-end=\"1830\"\u003e4. Built for Industrial Safety\u003c\/h3\u003e\n\u003cp data-start=\"1831\" data-end=\"1972\"\u003eTemperature measurement in high-heat processes is critical.\u003cbr data-start=\"1890\" data-end=\"1893\"\u003e👉 This model ensures \u003cstrong data-start=\"1915\" data-end=\"1946\"\u003estable, repeatable readings\u003c\/strong\u003e under extreme conditions.\u003c\/p\u003e\n\u003chr data-start=\"1974\" data-end=\"1977\"\u003e\n\u003ch2 data-section-id=\"3vljya\" data-start=\"1979\" data-end=\"2015\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cp data-start=\"2017\" data-end=\"2112\"\u003e\u003cstrong data-start=\"2017\" data-end=\"2040\"\u003eIndustrial Furnaces\u003c\/strong\u003e\u003cbr data-start=\"2040\" data-end=\"2043\"\u003eMonitor temperature to ensure stable heating and prevent overheating.\u003c\/p\u003e\n\u003cp data-start=\"2114\" data-end=\"2205\"\u003e\u003cstrong data-start=\"2114\" data-end=\"2135\"\u003eChemical Reactors\u003c\/strong\u003e\u003cbr data-start=\"2135\" data-end=\"2138\"\u003eMaintain precise temperature control in high-temperature reactions.\u003c\/p\u003e\n\u003cp data-start=\"2207\" data-end=\"2289\"\u003e\u003cstrong data-start=\"2207\" data-end=\"2237\"\u003eWaste Incineration Systems\u003c\/strong\u003e\u003cbr data-start=\"2237\" data-end=\"2240\"\u003eEnsure safe combustion and regulatory compliance.\u003c\/p\u003e\n\u003ch2 data-section-id=\"de9wf\" data-start=\"2296\" data-end=\"2314\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"2316\" data-end=\"2471\"\u003e\u003cstrong data-start=\"2316\" data-end=\"2360\"\u003eQ: What temperature range can it handle?\u003c\/strong\u003e\u003cbr data-start=\"2360\" data-end=\"2363\"\u003eA: It is designed for \u003cstrong data-start=\"2385\" data-end=\"2420\"\u003every high-temperature processes\u003c\/strong\u003e, typically in furnace and combustion applications.\u003c\/p\u003e\n\u003cp data-start=\"2473\" data-end=\"2622\"\u003e\u003cstrong data-start=\"2473\" data-end=\"2515\"\u003eQ: Why not use a standard thermometer?\u003c\/strong\u003e\u003cbr data-start=\"2515\" data-end=\"2518\"\u003eA: Standard sensors cannot withstand \u003cstrong data-start=\"2555\" data-end=\"2592\"\u003eextreme heat and harsh conditions\u003c\/strong\u003e, leading to frequent failure.\u003c\/p\u003e\n\u003cp data-start=\"2624\" data-end=\"2763\"\u003e\u003cstrong data-start=\"2624\" data-end=\"2657\"\u003eQ: Is a thermowell necessary?\u003c\/strong\u003e\u003cbr data-start=\"2657\" data-end=\"2660\"\u003eA: Yes. In high-temperature environments, a \u003cstrong data-start=\"2704\" data-end=\"2762\"\u003ethermowell protects the sensor and improves durability\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338578133053,"sku":null,"price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-itherm-flameline-taf12s-high-temperature-thermometer..webp?v=1783928575"},{"product_id":"endress-hauser-itherm-flameline-taf12d-thermometer","title":"Endress+Hauser iTHERM FlameLine TAF12D Thermometer","description":"\u003cp\u003eMeasuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.\u003c\/p\u003e\n\u003ch2\u003eiTHERM FlameLine TAF12D High temperature thermometer\u003c\/h2\u003e\n\u003cp\u003eMetric TC thermometer with dual ceramic thermowell for high-temperature applications\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eclass 2 acc. to IEC 60584\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eat 20 °C: 1 bar (15 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eType S:\u003cbr\u003e0 °C ...1.600 °C\u003cbr\u003e(32 °F ...2.912 °F)\u003cbr\u003eType R:\u003cbr\u003e0 °C ...1.600 °C\u003cbr\u003e(32 °F ...2.912 °F)\u003cbr\u003eType B:\u003cbr\u003e600 °C ...1.700 °C\u003cbr\u003e(1.112 °F ...3.092 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eup to 3.500,00 mm (137,80'')\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eMeasuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\" data-cs-pcueid=\"JVcAPU\"\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eProcess temperatures: up to +1700 °C (+3092 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"8ozaIq\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eLong lifetime by usage of innovative thermowell materials with increased wear and chemical resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"R57x5p\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eLong term stable measurement due to sensor protection with non-porous materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"zCVLYX\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFlexible product selection by modular design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"KZcpeh\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eOptimized life cycle costs by means of replaceable spare parts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338584719421,"sku":null,"price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-itherm-flameline-taf12d-high-temperature-thermometer.webp?v=1783929030"},{"product_id":"endress-hauser-thermophant-t-ttr31-temperature-switch","title":"Endress+Hauser Thermophant T TTR31 Temperature switch","description":"\u003cp data-start=\"218\" data-end=\"378\"\u003eThe \u003cstrong data-start=\"222\" data-end=\"279\"\u003eEndress+Hauser Thermophant T TTR31 temperature switch\u003c\/strong\u003e is designed for \u003cstrong data-start=\"296\" data-end=\"353\"\u003ereliable temperature monitoring and switching control\u003c\/strong\u003e in industrial processes.\u003c\/p\u003e\n\u003cp data-start=\"380\" data-end=\"579\"\u003eIt combines \u003cstrong data-start=\"392\" data-end=\"431\"\u003emeasurement and switching functions\u003c\/strong\u003e in one compact device. When a set temperature is reached, it can directly \u003cstrong data-start=\"506\" data-end=\"578\"\u003etrigger alarms, start\/stop equipment, or activate protection systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"581\" data-end=\"598\"\u003eTypical use:\u003c\/p\u003e\n\u003cul data-start=\"599\" data-end=\"685\"\u003e\n\u003cli data-section-id=\"1v50a69\" data-start=\"599\" data-end=\"623\"\u003eEquipment protection\u003c\/li\u003e\n\u003cli data-section-id=\"1rt6i05\" data-start=\"624\" data-end=\"650\"\u003eCooling system control\u003c\/li\u003e\n\u003cli data-section-id=\"11oedsz\" data-start=\"651\" data-end=\"685\"\u003eProcess temperature monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"687\" data-end=\"709\"\u003eNot suitable for:\u003c\/p\u003e\n\u003cul data-start=\"710\" data-end=\"777\"\u003e\n\u003cli data-section-id=\"1ha51wj\" data-start=\"710\" data-end=\"777\"\u003eHigh-precision temperature measurement only (no control needed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/bdih-download.endress.com\/file\/3b5a676f98d94da43bc1b3343ad3f94d\/TI00105REN_1725-00.pdf\"\u003eTechnical Information Thermophant T TTR31\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"7f50ka\" data-start=\"784\" data-end=\"839\"\u003e When Should You Use a Temperature Switch?\u003c\/h2\u003e\n\u003cp data-start=\"841\" data-end=\"887\"\u003eChoose the TTR31 if your application requires:\u003c\/p\u003e\n\u003cp data-start=\"889\" data-end=\"1099\"\u003e• \u003cstrong data-start=\"891\" data-end=\"940\"\u003eAutomatic ON\/OFF control based on temperature\u003c\/strong\u003e\u003cbr data-start=\"940\" data-end=\"943\"\u003e• Equipment protection (e.g. overheating shutdown)\u003cbr data-start=\"993\" data-end=\"996\"\u003e• Simple integration without a full control system\u003cbr data-start=\"1046\" data-end=\"1049\"\u003e• Replacement of mechanical temperature switches\u003c\/p\u003e\n\u003cp data-start=\"1101\" data-end=\"1181\"\u003eIf you only need temperature display or logging, a transmitter is more suitable.\u003c\/p\u003e\n\u003ch2 data-section-id=\"vzspx8\" data-start=\"1188\" data-end=\"1224\"\u003e What Makes It Different?\u003c\/h2\u003e\n\u003ch3 data-section-id=\"z1ta4x\" data-start=\"1226\" data-end=\"1272\"\u003e1. Measurement + Switching in One Device\u003c\/h3\u003e\n\u003cp data-start=\"1273\" data-end=\"1323\"\u003eUnlike traditional setups, this device combines:\u003c\/p\u003e\n\u003cul data-start=\"1324\" data-end=\"1372\"\u003e\n\u003cli data-section-id=\"2z49da\" data-start=\"1324\" data-end=\"1351\"\u003eTemperature measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1jbun39\" data-start=\"1352\" data-end=\"1372\"\u003eSwitching output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1374\" data-end=\"1418\"\u003e No need for separate controller + sensor.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zmvpe3\" data-start=\"1425\" data-end=\"1472\"\u003e2. Fast Response for Equipment Protection\u003c\/h3\u003e\n\u003cp data-start=\"1473\" data-end=\"1583\"\u003eIt reacts quickly when temperature reaches the set point.\u003cbr data-start=\"1530\" data-end=\"1533\"\u003eHelps prevent overheating and equipment damage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ax1lz9\" data-start=\"1590\" data-end=\"1628\"\u003e3. Compact and Easy Installation\u003c\/h3\u003e\n\u003cp data-start=\"1629\" data-end=\"1747\"\u003eThe integrated design reduces wiring and installation effort.\u003cbr data-start=\"1690\" data-end=\"1693\"\u003eIdeal for machines, pipelines, and compact systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19a89pj\" data-start=\"1754\" data-end=\"1796\"\u003e4. Digital Configuration and Display\u003c\/h3\u003e\n\u003cp data-start=\"1797\" data-end=\"1911\"\u003eUsers can easily set switching points and monitor values.\u003cbr data-start=\"1854\" data-end=\"1857\"\u003e Improves usability compared to mechanical switches.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1jbggsw\" data-start=\"1918\" data-end=\"1953\"\u003e Typical Applications\u003c\/h2\u003e\n\u003cp data-start=\"1955\" data-end=\"2048\"\u003e\u003cstrong data-start=\"1955\" data-end=\"1984\"\u003ePump and Motor Protection\u003c\/strong\u003e\u003cbr data-start=\"1984\" data-end=\"1987\"\u003eAutomatically stop equipment when temperature exceeds limits.\u003c\/p\u003e\n\u003cp data-start=\"2050\" data-end=\"2131\"\u003e\u003cstrong data-start=\"2050\" data-end=\"2069\"\u003eCooling Systems\u003c\/strong\u003e\u003cbr data-start=\"2069\" data-end=\"2072\"\u003eControl cooling activation based on temperature thresholds.\u003c\/p\u003e\n\u003cp data-start=\"2133\" data-end=\"2208\"\u003e\u003cstrong data-start=\"2133\" data-end=\"2154\"\u003eProcess Pipelines\u003c\/strong\u003e\u003cbr data-start=\"2154\" data-end=\"2157\"\u003eMonitor and control fluid temperature in real time.\u003c\/p\u003e\n\u003ch2 data-section-id=\"ooyjxc\" data-start=\"2215\" data-end=\"2232\"\u003e FAQ\u003c\/h2\u003e\n\u003cp data-start=\"2234\" data-end=\"2385\"\u003e\u003cstrong data-start=\"2234\" data-end=\"2293\"\u003eQ: Is this a replacement for a temperature transmitter?\u003c\/strong\u003e\u003cbr data-start=\"2293\" data-end=\"2296\"\u003eA: Not exactly. It is designed for \u003cstrong data-start=\"2331\" data-end=\"2354\"\u003econtrol (switching)\u003c\/strong\u003e, not just signal transmission.\u003c\/p\u003e\n\u003cp data-start=\"2387\" data-end=\"2510\"\u003e\u003cstrong data-start=\"2387\" data-end=\"2428\"\u003eQ: Can it directly control equipment?\u003c\/strong\u003e\u003cbr data-start=\"2428\" data-end=\"2431\"\u003eA: Yes. It provides \u003cstrong data-start=\"2451\" data-end=\"2472\"\u003eswitching outputs\u003c\/strong\u003e to trigger alarms or control systems.\u003c\/p\u003e\n\u003cp data-start=\"2512\" data-end=\"2645\"\u003e\u003cstrong data-start=\"2512\" data-end=\"2571\"\u003eQ: What is the main advantage over mechanical switches?\u003c\/strong\u003e\u003cbr data-start=\"2571\" data-end=\"2574\"\u003eA: It offers \u003cstrong data-start=\"2587\" data-end=\"2644\"\u003ehigher accuracy, easier setup, and better reliability\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338589143101,"sku":null,"price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-thermophant-t-ttr31-temperature-switch.webp?v=1783929469"},{"product_id":"endress-hauser-tr66-explosion-proof-pt100-thermometer","title":"Endress+Hauser TR66 Explosion-proof Pt100 Thermometer","description":"\u003cp\u003eThe robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil \u0026amp; Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors.\u003c\/p\u003e\n\u003ch2\u003eTR66 Explosion-proof Pt100 Thermometer\u003c\/h2\u003e\n\u003cp\u003eSafe monitoring of process temperatures in challenging applications e. g. in the Oil \u0026amp; Gas industry\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eclass A acc. to IEC 60751\u003cbr\u003eclass AA acc. to IEC 60751\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eResponse time\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003edepending on configuration\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eat 20 °C: 500 bar (7.252 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003ePT100 TF iTHERM StrongSens:\u003cbr\u003e-50 °C ...500 °C\u003cbr\u003e(-58 °F ...932 °F)\u003cbr\u003ePT100 WW:\u003cbr\u003e-200 °C ...600 °C\u003cbr\u003e(-328 °F ...1.112 °F)\u003cbr\u003ePT100 TF:\u003cbr\u003e-50 °C ...400 °C\u003cbr\u003e(-58 °F ...752 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eup to 5.000,00 mm (196,85'')\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil \u0026amp; Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHeavy duty applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eOil \u0026amp; Gas processing industry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMeasuring range: -200 to +600 °C (-328 to 1112 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eStatic pressure range up to 100 bar (1450 psi)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eProtection class: IP68\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eTypes of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), flameproof (Ex d), non-sparking (Ex nA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHigh degree of insert compatibility and design as per DIN 43772\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eExtension neck to protect the head transmitter from overheating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFast response time with reduced\/tapered tip form\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHigh degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMarine approval\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338592059453,"sku":null,"price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-tr66-explosion-proof-pt100-thermometer.webp?v=1783929700"},{"product_id":"endress-hauser-tr15-modular-rtd-thermometer","title":"Endress+Hauser TR15 Modular RTD Thermometer","description":"\u003cp data-start=\"205\" data-end=\"425\"\u003eThe \u003cstrong data-start=\"209\" data-end=\"263\"\u003eEndress+Hauser iTHERM TR15 Modular RTD Thermometer\u003c\/strong\u003e is a \u003cstrong data-start=\"269\" data-end=\"323\"\u003erobust industrial temperature measurement solution\u003c\/strong\u003e designed for \u003cstrong data-start=\"337\" data-end=\"371\"\u003edemanding process applications\u003c\/strong\u003e such as \u003cstrong data-start=\"380\" data-end=\"424\"\u003esteam, gas, chemical, and energy systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"427\" data-end=\"677\"\u003eIt uses a \u003cstrong data-start=\"437\" data-end=\"492\"\u003eresistance temperature detector (RTD, Pt100\/Pt1000)\u003c\/strong\u003e for accurate and stable temperature measurement. With its \u003cstrong data-start=\"551\" data-end=\"600\"\u003emodular design and replaceable insert concept\u003c\/strong\u003e, TR15 ensures \u003cstrong data-start=\"615\" data-end=\"676\"\u003ehigh flexibility, easy maintenance, and long service life\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"679\" data-end=\"867\"\u003eThe instrument is suitable for \u003cstrong data-start=\"710\" data-end=\"761\"\u003ehigh-pressure and high-temperature environments\u003c\/strong\u003e, making it widely used in \u003cstrong data-start=\"788\" data-end=\"866\"\u003eoil \u0026amp; gas, chemical processing, power generation, and industrial utilities\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"869\" data-end=\"1053\"\u003eNot Recommended For:\u003cbr data-start=\"889\" data-end=\"892\"\u003e• Extremely fast dynamic temperature changes requiring ultra-fast response sensors\u003cbr data-start=\"974\" data-end=\"977\"\u003e• Applications without thermowell protection in high-flow aggressive media\u003c\/p\u003e\n\u003cp data-start=\"869\" data-end=\"1053\"\u003e\u003ca href=\"https:\/\/bdih-download.endress.com\/file\/17117c83e0990df00db5287ae744cce4\/TI01100TEN_0423-00.pdf\"\u003eTechnical Information TR15\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"uztocl\" data-start=\"1088\" data-end=\"1107\"\u003eSelection Notes\u003c\/h3\u003e\n\u003cp data-start=\"1109\" data-end=\"1685\"\u003e• Confirm the \u003cstrong data-start=\"1123\" data-end=\"1152\"\u003eprocess temperature range\u003c\/strong\u003e, typically from cryogenic to high-temperature steam conditions\u003cbr data-start=\"1215\" data-end=\"1218\"\u003e• Select appropriate \u003cstrong data-start=\"1239\" data-end=\"1266\"\u003eprocess connection type\u003c\/strong\u003e, such as threaded, flanged, or weld-in installation\u003cbr data-start=\"1318\" data-end=\"1321\"\u003e• Verify if a \u003cstrong data-start=\"1335\" data-end=\"1361\"\u003ethermowell is required\u003c\/strong\u003e, especially for high-pressure or corrosive media\u003cbr data-start=\"1410\" data-end=\"1413\"\u003e• Choose \u003cstrong data-start=\"1422\" data-end=\"1437\"\u003einsert type\u003c\/strong\u003e, including mineral insulated (MI) or iTHERM StrongSens for enhanced stability\u003cbr data-start=\"1515\" data-end=\"1518\"\u003e• Confirm \u003cstrong data-start=\"1528\" data-end=\"1559\"\u003ehazardous area requirements\u003c\/strong\u003e, such as ATEX or IECEx approval if needed\u003cbr data-start=\"1601\" data-end=\"1604\"\u003e• Define whether a \u003cstrong data-start=\"1623\" data-end=\"1671\"\u003ehead transmitter (4–20 mA \/ HART \/ Fieldbus)\u003c\/strong\u003e is required\u003c\/p\u003e\n\u003ch3 data-section-id=\"1d7ofwq\" data-start=\"1720\" data-end=\"1767\"\u003eWhy Choose the TR15 Modular RTD Thermometer\u003c\/h3\u003e\n\u003cp data-start=\"1769\" data-end=\"1979\"\u003e• \u003cstrong data-start=\"1771\" data-end=\"1811\"\u003eHigh Flexibility with Modular Design\u003c\/strong\u003e\u003cbr data-start=\"1811\" data-end=\"1814\"\u003eThe replaceable insert concept allows easy maintenance and reduced downtime. Therefore, calibration and replacement can be done without removing the entire assembly.\u003c\/p\u003e\n\u003cp data-start=\"1981\" data-end=\"2167\"\u003e• \u003cstrong data-start=\"1983\" data-end=\"2027\"\u003eReliable Measurement in Harsh Conditions\u003c\/strong\u003e\u003cbr data-start=\"2027\" data-end=\"2030\"\u003eDesigned for \u003cstrong data-start=\"2043\" data-end=\"2076\"\u003ehigh pressure (up to 400 bar)\u003c\/strong\u003e and extreme temperatures. As a result, it performs reliably in steam and gas applications.\u003c\/p\u003e\n\u003cp data-start=\"2169\" data-end=\"2307\"\u003e• \u003cstrong data-start=\"2171\" data-end=\"2211\"\u003eFast and Stable Temperature Response\u003c\/strong\u003e\u003cbr data-start=\"2211\" data-end=\"2214\"\u003eOptional tapered tip design improves thermal response time, ensuring faster process feedback.\u003c\/p\u003e\n\u003cp data-start=\"2309\" data-end=\"2456\"\u003e• \u003cstrong data-start=\"2311\" data-end=\"2348\"\u003eWide Industrial Application Range\u003c\/strong\u003e\u003cbr data-start=\"2348\" data-end=\"2351\"\u003eSuitable for \u003cstrong data-start=\"2364\" data-end=\"2455\"\u003echemical plants, oil \u0026amp; gas facilities, power generation, and general process industries\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2458\" data-end=\"2629\"\u003e• \u003cstrong data-start=\"2460\" data-end=\"2496\"\u003eThermowell Protection Capability\u003c\/strong\u003e\u003cbr data-start=\"2496\" data-end=\"2499\"\u003eCan be installed with robust thermowells made of stainless steel, duplex, or alloy materials, ensuring safety in aggressive media.\u003c\/p\u003e\n\u003cp data-start=\"2631\" data-end=\"2800\"\u003e• \u003cstrong data-start=\"2633\" data-end=\"2667\"\u003eFlexible Communication Options\u003c\/strong\u003e\u003cbr data-start=\"2667\" data-end=\"2670\"\u003eSupports head transmitters with \u003cstrong data-start=\"2702\" data-end=\"2753\"\u003e4–20 mA, HART, PROFIBUS, or FOUNDATION Fieldbus\u003c\/strong\u003e, enabling integration into automation systems.\u003c\/p\u003e\n\u003cp data-start=\"2802\" data-end=\"2927\"\u003e• \u003cstrong data-start=\"2804\" data-end=\"2832\"\u003eHazardous Area Certified\u003c\/strong\u003e\u003cbr data-start=\"2832\" data-end=\"2835\"\u003eAvailable with \u003cstrong data-start=\"2850\" data-end=\"2879\"\u003eEx ia and Ex nA approvals\u003c\/strong\u003e, making it suitable for explosive environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"2965\" data-end=\"2972\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"2974\" data-end=\"3105\"\u003e\u003cstrong data-start=\"2974\" data-end=\"3007\"\u003eQ: What is the TR15 used for?\u003c\/strong\u003e\u003cbr data-start=\"3007\" data-end=\"3010\"\u003eA: It is used for \u003cstrong data-start=\"3028\" data-end=\"3104\"\u003eindustrial temperature measurement in gas, steam, and chemical processes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3107\" data-end=\"3246\"\u003e\u003cstrong data-start=\"3107\" data-end=\"3146\"\u003eQ: What type of sensor does it use?\u003c\/strong\u003e\u003cbr data-start=\"3146\" data-end=\"3149\"\u003eA: It uses an \u003cstrong data-start=\"3163\" data-end=\"3220\"\u003eRTD (Pt100 or Pt1000 resistance temperature detector)\u003c\/strong\u003e for accurate measurement.\u003c\/p\u003e\n\u003cp data-start=\"3248\" data-end=\"3387\"\u003e\u003cstrong data-start=\"3248\" data-end=\"3283\"\u003eQ: Can it handle high pressure?\u003c\/strong\u003e\u003cbr data-start=\"3283\" data-end=\"3286\"\u003eA: Yes. It supports \u003cstrong data-start=\"3306\" data-end=\"3339\"\u003estatic pressure up to 400 bar\u003c\/strong\u003e, making it suitable for demanding applications.\u003c\/p\u003e\n\u003cp data-start=\"3389\" data-end=\"3521\"\u003e\u003cstrong data-start=\"3389\" data-end=\"3431\"\u003eQ: Is it suitable for hazardous areas?\u003c\/strong\u003e\u003cbr data-start=\"3431\" data-end=\"3434\"\u003eA: Yes. It is available with \u003cstrong data-start=\"3463\" data-end=\"3520\"\u003eATEX, IECEx, and other explosion protection approvals\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338593566781,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-tr15-modular-rtd-thermometer.webp?v=1783929878"},{"product_id":"endress-hauser-tr15-modular-rtd-thermometer-1","title":"Endress+Hauser TR15 Modular RTD Thermometer","description":"\u003cp\u003eThe high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.\u003c\/p\u003e\n\u003ch2\u003eTC15 Modular TC thermometer\u003c\/h2\u003e\n\u003cp\u003eComprehensive and common temperature measurement technology for almost all branches of industry\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eclass 1 acc. to IEC 60584\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eResponse time\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003edepending on configuration\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eat 20 °C: 400 bar (5.802 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eType K:\u003cbr\u003emax. 1.100 °C\u003cbr\u003e(max. 2.012 °F)\u003cbr\u003eType J:\u003cbr\u003emax. 750 °C\u003cbr\u003e(max. 1.382 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eup to 30.000,00 mm (1.181,10'')\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eUniversal range of application\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eParticularly suitable for steam and gas applications with high process pressures and temperatures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMeasuring range: –40 to 1100 °C (–40 to 2012 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eStatic pressure range up to 400 bar (5800 psi)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDegree of protection: up to IP68\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHigh degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHigh degree of insert compatibility and design as per DIN 43772\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eExtension neck to protect the head transmitter from overheating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFast response time with reduced\/tapered tip form\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eTypes of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), non-sparking (Ex nA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHead transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338598973501,"sku":null,"price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-tr15-modular-rtd-thermometer..png?v=1783930638"},{"product_id":"endress-hauser-t13-explosion-proof-pt100-thermometer","title":"Endress+Hauser T13 Explosion-Proof Pt100 Thermometer","description":"\u003cp class=\"eh-p-v\"\u003eThe robust device with a barstock thermowell is a complete unit ready for use with various housing transmitter heads to meet the application and space requirements. The unit offers enhanced measurement accuracy and reliability. A variety of process connections, dimensions, and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe T13 temperature sensor is a RTD assembly installed in thermowell and designed for use in harsh environments and explosive areas, due to his FM and CSA approvals.\u003cbr\u003eThe sensor is made up of a measurement probe with an insulated RTD element, sheath and a thermowell made of bar-stock material.\u003c\/p\u003e\n\u003ch2\u003eT13 Explosion proof Pt100 thermometer, US style\u003c\/h2\u003e\n\u003cp\u003eSafe monitoring of process temperatures in challenging applications e. g. in the Oil \u0026amp; Gas industry\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eclass A acc. to IEC 60751\u003cbr\u003eclass B acc. to IEC 60751\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eResponse time\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003edepending on configuration\u003cbr\u003e63% rt = 20 s\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eat 20 °C: 100 bar (1.450 psi)\u003cbr\u003edepends on configuration\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003ePT100 WW:\u003cbr\u003e-200 °C … 600 °C\u003cbr\u003e(-328 °F … 1.112 °F)\u003cbr\u003ePT100 TF:\u003cbr\u003e-50 °C … 200 °C\u003cbr\u003e(-58 °F … 392 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eup to 22.5\" (571 mm)\u003cbr\u003eothers on request\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe robust device with a barstock thermowell is a complete unit ready for use with various housing transmitter heads to meet the application and space requirements. The unit offers enhanced measurement accuracy and reliability. A variety of process connections, dimensions, and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe T13 temperature sensor is a RTD assembly installed in thermowell and designed for use in harsh environments and explosive areas, due to his FM and CSA approvals.\u003cbr\u003eThe sensor is made up of a measurement probe with an insulated RTD element, sheath and a thermowell made of bar-stock material.\u003c\/p\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe sensor assembly can be used in process industries such as:\u003c\/p\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eChemicals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003ePetrochemical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eRefineries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eOffshore Platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFM\/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eOne source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eRemove and install straight out of the box!\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eImproved galvanic isolation on most devices (2 kV)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eSimplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor, thermowell and transmitter assembly for a complete point solution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eAll iTEMP transmitters provide long term stability ≤0.05% per year\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338601136189,"sku":null,"price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-t13-explosion-proof-pt100-thermometer..png?v=1783930983"},{"product_id":"endress-hauser-itherm-moduline-tst90-thermometer","title":"Endress+Hauser iTHERM ModuLine TST90 Thermometer","description":"\u003cp\u003eThe thermometer is mainly used in the chemical industry but also finds its use in other branches. The device is used for high-precision measurement of temperature\u003cbr\u003edifferences with matched sensor pairs. A variety of dimensions offers flexible application possibilities.\u003c\/p\u003e\n\u003ch2\u003eiTHERM ModuLine TST90 Industrial modular thermometer\u003c\/h2\u003e\n\u003cp\u003ePaired set of metric RTD thermometers for thermal energy measurements\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003e+\/- 0.05 K (refering to delta-T)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eResponse time\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003edepending on configuration\u003cbr\u003et50 = 10 s\u003cbr\u003et90 = 31 s\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eat 20 °C: 50 bar (725 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003ePT 100:\u003cbr\u003e-50 °C …400 °C\u003cbr\u003e(-58 °F …752 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eup to 4.000,00 mm (157,48'')\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe thermometer is mainly used in the chemical industry but also finds its use in other branches. The device is used for high-precision measurement of temperature\u003cbr\u003edifferences with matched sensor pairs. A variety of dimensions offers flexible application possibilities.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\" data-cs-pcueid=\"IXfyeP\"\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eUniversally usable for thermal energy measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMeasuring range: -50 to +400 °C (-58 to +752 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003ePaired in the range: 0 to +120 °C (+32 to +248 °F), Deviation of the sensors: ± 0.05 K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003ePaired in the range: –40 to 0 °C (-40 to 32 °F), Deviation of the sensors: ± 0.1 K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eProtection class: up to IP68\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"a6wNYI\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFast replaceability of the insert\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"kUjMbG\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHigh degree of insert compatibility and design as per DIN 43772\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"txjpY5\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eFast response time with reduced tip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338627809341,"sku":null,"price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-itherm-moduline-tst90-industrial-modular-thermometer.png?v=1783934319"},{"product_id":"endress-hauser-tmr31-compact-thermometer","title":"Endress+Hauser TMR31 Compact Thermometer","description":"\u003cp class=\"eh-p-v\"\u003eWith cost efficiency, optimal use of space, reliable operation, easy installation and commissioning the TMR31 fulfills the requirements of modern process measurement technology. Vibration-proof integrated thin-film sensors guarantee highest operational safety at the fastest response times.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\" data-cs-pcueid=\"QgwRmW\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe TMR31 compact thermometers are used to measure temperatures from -50 °C to +150 °C (-58 °F to +302 °F), or up to +200 °C (+392 °F) with neck. The most common installation locations are tanks and pipes. TMR31 with process connections for general applications.\u003c\/p\u003e\n\u003ch2\u003eTMR31 Compact thermometer\u003c\/h2\u003e\n\u003cp\u003eMetric RTD 4-20 mA compact thermometer for industrial applications\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eclass A acc. to IEC 60751\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eResponse time\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003et50 = 1 s\u003cbr\u003et90 = 2 s\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eat 20 °C: 100 bar (1.450 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003ePT 100:\u003cbr\u003e-50 °C ...200 °C\u003cbr\u003e(-58 °F ...392 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eup to 600,00 mm (23,62'')\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eWith cost efficiency, optimal use of space, reliable operation, easy installation and commissioning the TMR31 fulfills the requirements of modern process measurement technology. Vibration-proof integrated thin-film sensors guarantee highest operational safety at the fastest response times.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\" data-cs-pcueid=\"QgwRmW\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eThe TMR31 compact thermometers are used to measure temperatures from -50 °C to +150 °C (-58 °F to +302 °F), or up to +200 °C (+392 °F) with neck. The most common installation locations are tanks and pipes. TMR31 with process connections for general applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"NeSlQn\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eSmall, compact design made entirely of stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"awTuG3\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eExtremely short response times\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"lNQOgF\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHighly accurate even with short insertion lengths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"o9er38\"\u003e\n\u003cp class=\"eh-generic--text\"\u003e4-wire, Pt100 or PC-programmable transmitter with 4 to 20 mA output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"Shssit\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eConfiguration and visualization with ReadWin\u003csup\u003e®\u003c\/sup\u003e 2000 PC operating software, which is free of charge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"Unl9N0\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eBreakdown information in event of sensor break or sensor short-circuit, adjustable as per NAMUR NE43\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"O06gg2\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMarine approval\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338673061949,"sku":null,"price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-tmr31-compact-thermometer.png?v=1783937928"},{"product_id":"endress-hauser-itherm-moduline-tst434b-thermometer","title":"Endress+Hauser iTHERM ModuLine TST434B Thermometer","description":"\u003cp\u003eThe iTHERM ModuLine TST434B RTD thermometer is specially designed for monitoring the room temperature in almost all industries.\u003cbr\u003eIt is available as a complete unit including Endress+Hauser temperature transmitters for enhanced measurement accuracy and reliability compared to directly wired sensors. With a variety of common and advanced outputs and communication protocols, they offer easy customizing.\u003c\/p\u003e\n\u003ch2\u003eiTHERM ModuLine TST434B Industrial modular thermometer\u003c\/h2\u003e\n\u003cp\u003eRTD thermometer for outdoor and indoor ambient temperature measurement\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eclass A acc. to IEC 60751\u003cbr\u003eclass B acc. to IEC 60751\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eat 20 °C: 1 bar (15 psi)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003ePT 100:\u003cbr\u003e-50 °C ...150 °C\u003cbr\u003e(-58 °F ...302 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eThe iTHERM ModuLine TST434B RTD thermometer is specially designed for monitoring the room temperature in almost all industries.\u003cbr\u003eIt is available as a complete unit including Endress+Hauser temperature transmitters for enhanced measurement accuracy and reliability compared to directly wired sensors. With a variety of common and advanced outputs and communication protocols, they offer easy customizing.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\" data-cs-pcueid=\"wiYctB\"\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eOutdoor or indoor ambient temperature measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMaximum measuring range: –50 to +150 °C (–58 to +302 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDegree of protection: IP66\/68 (NEMA Type 4x encl.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"HTUfUJ\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eRobust terminal heads according to DIN EN 50446 or stable plastic housings offer optimal protection from extreme ambient conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"46N6Nm\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eReliable, long term stable and accurate indoor or outdoor ambient temperature measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"cNcQSk\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eSimple and fast wall mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"qgI2vI\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eOptional head transmitters: Analog 4 to 20 mA, HART®, PROFIBUS® PA, FOUNDATION Fieldbus™, IO-Link, PROFINET® over Ethernet-APL\/SPE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338676863037,"sku":null,"price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-itherm-moduline-tst434b-industrial-modular-thermometer.png?v=1783938666"},{"product_id":"endress-hauser-itherm-moduline-tm121-thermometer","title":"Endress+Hauser iTHERM ModuLine TM121 Thermometer","description":"\u003cp\u003eRTD or TC assembly characterized by basic sensor technology, application in non-hazardous areas, standard extension neck, low-cost unit. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.\u003c\/p\u003e\n\u003ch2\u003eiTHERM ModuLine TM121 Industrial modular thermometer\u003c\/h2\u003e\n\u003cp\u003eFundamental metric RTD\/TC thermometer with welded thermowell for a wide range of industrial applications\u003c\/p\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul class=\"eh-result-list eh-product-info-category--items\"\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eClass A acc. to IEC 60751\u003cbr\u003eClass B acc. to IEC 60751\u003cbr\u003eClass standard acc. to ASTM E230\u003cbr\u003eClass 2 acc. to IEC 60584-2\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eResponse time\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003et90 around 100 s\u003cbr\u003edepending on configuration\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003edepending on the configuration\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eBasic PT100 TF:\u003cbr\u003e-50 °C …200 °C\u003cbr\u003e(-58 °F …392 °F)\u003cbr\u003eTyp K:\u003cbr\u003emax. 1.100 °C\u003cbr\u003e(max. 2.012 °F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-product-info-category--item eh-p-v\"\u003e\n\u003cdiv class=\"eh-grid eh-grid--no-spacing\"\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-bold eh-p-b-2\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eh-cell eh-cell--12-col\"\u003e\n\u003cp\u003eup to 1.000,0 mm (39'')\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eField of application\u003c\/h3\u003e\n\u003cp class=\"eh-p-v\"\u003eRTD or TC assembly characterized by basic sensor technology, application in non-hazardous areas, standard extension neck, low-cost unit. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\" data-cs-pcueid=\"cSByBA\"\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eUniversal range of application\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eApplication in non-hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eMeasuring range: –50 to +650 °C (–58 to +1202 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003ePressure range up to 50 bar (725 psi)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDegree of protection: up to IP 68\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"eh-headline-03 eh-p-b eh-m-t-xxlg\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"sfPhvU\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eEconomical, reliable measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"I4MMBY\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eUser-friendly from product selection to maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"B8gDVC\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eWide range of process connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\" data-cs-pcueid=\"VECPkJ\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eEasy and safe device setup and service using Bluetooth® communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":43338682728509,"sku":null,"price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/files\/endress-hauser-itherm-moduline-tm121-industrial-modular-thermometer.png?v=1783939063"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/4141\/3693\/collections\/2.png?v=1782901275","url":"https:\/\/proinstru.com\/collections\/endresss-hauser.oembed?page=9","provider":"Process Instrument","version":"1.0","type":"link"}